Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vaccine ; 37(43): 6500-6509, 2019 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-31515141

RESUMO

BACKGROUND: Schistosomiasis caused by Schistosoma mansoni (Sm) is a chronic, debilitating and potentially deadly neglected tropical disease. The licensure of a vaccine to prevent schistosomiasis would represent a major breakthrough in public health. METHODS: The safety and immunogenicity of a candidate Sm vaccine were assessed in this phase I, double-blind, dose-escalation trial. Seventy-two healthy Sm-naïve 18-50 year olds were randomized to receive 3 doses ∼ 8 weeks apart of saline placebo, or 10 µg, 30 µg, or 100 µg of recombinant Sm-Tetraspanin-2 vaccine formulated on aluminum hydroxide adjuvant (Sm-TSP-2/Al) with or without 5 µg of glucopyranosyl lipid A aqueous formulation (GLA-AF). Clinical and serologic responses were assessed for 1 year after dose 3. RESULTS: Vaccines were safe and well-tolerated. The most common reactions were injection site tenderness and pain, and headache and fatigue. Tenderness and pain were more frequent in groups receiving vaccine with GLA-AF than placebo (p = 0.0036 and p = 0.0014, respectively). Injection site reactions among those given Sm-TSP-2/Al with GLA-AF lasted 1.22 and 1.33 days longer than those receiving Sm-TSP-2/Al without GLA-AF or placebo (p < 0.001 for both). Dose- and adjuvant-related increases in serum IgG against Sm-TSP-2 were observed. Peak IgG levels occurred 14 days after dose 3. Seroresponse frequencies were low among recipients of Sm-TSP-2/Al without GLA-AF, but higher among subjects receiving 30 µg or 100 µg of Sm-TSP-2/Al with GLA-AF. More seroresponses were observed among those given 30 µg or 100 µg of Sm-TSP-2/Al with GLA-AF compared to placebo (p = 0.023 and p < 0.001, respectively). Seroresponse frequencies were 0%, 30%, 50%, and 89%, respectively, among those given placebo, or 10 µg, 30 µg or 100 µg of Sm-TSP-2/Al with GLA-AF, suggesting a dose-response relationship for Sm-TSP-2/Al with GLA-AF (p = 0.0001). CONCLUSIONS: Sm-TSP-2/Al with or without GLA-AF was safe and well tolerated in a Sm-naïve population. A vaccine like the one under development may represent our best hope to eliminating this neglected tropical disease.


Assuntos
Anticorpos Anti-Helmínticos/sangue , Glucosídeos/imunologia , Imunogenicidade da Vacina , Lipídeo A/imunologia , Esquistossomose/prevenção & controle , Vacinas/imunologia , Adjuvantes Imunológicos/administração & dosagem , Adolescente , Adulto , Animais , Antígenos de Helmintos/imunologia , Estudos de Coortes , Citocinas/imunologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Voluntários Saudáveis , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Schistosoma mansoni , Vacinas/efeitos adversos , Adulto Jovem
2.
Am J Physiol Lung Cell Mol Physiol ; 295(4): L552-65, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18658273

RESUMO

Nanomaterials are frontier technological products used in different manufactured goods. Because of their unique physicochemical, electrical, mechanical, and thermal properties, single-walled carbon nanotubes (SWCNT) are finding numerous applications in electronics, aerospace devices, computers, and chemical, polymer, and pharmaceutical industries. SWCNT are relatively recently discovered members of the carbon allotropes that are similar in structure to fullerenes and graphite. Previously, we (47) have reported that pharyngeal aspiration of purified SWCNT by C57BL/6 mice caused dose-dependent granulomatous pneumonia, oxidative stress, acute inflammatory/cytokine responses, fibrosis, and decrease in pulmonary function. To avoid potential artifactual effects due to instillation/agglomeration associated with SWCNT, we conducted inhalation exposures using stable and uniform SWCNT dispersions obtained by a newly developed aerosolization technique (2). The inhalation of nonpurified SWCNT (iron content of 17.7% by weight) at 5 mg/m(3), 5 h/day for 4 days was compared with pharyngeal aspiration of varying doses (5-20 microg per mouse) of the same SWCNT. The chain of pathological events in both exposure routes was realized through synergized interactions of early inflammatory response and oxidative stress culminating in the development of multifocal granulomatous pneumonia and interstitial fibrosis. SWCNT inhalation was more effective than aspiration in causing inflammatory response, oxidative stress, collagen deposition, and fibrosis as well as mutations of K-ras gene locus in the lung of C57BL/6 mice.


Assuntos
Administração por Inalação , Inflamação/etiologia , Pulmão/efeitos dos fármacos , Mutagênese , Nanotubos de Carbono/efeitos adversos , Estresse Oxidativo/efeitos dos fármacos , Transtornos Respiratórios/induzido quimicamente , Aerossóis/administração & dosagem , Animais , Carbono/farmacologia , Feminino , Fibrose , Inflamação/patologia , Pulmão/patologia , Camundongos , Camundongos Endogâmicos C57BL , Faringe
3.
Appl Occup Environ Hyg ; 15(7): 561-8, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10893792

RESUMO

Porous foam has been used as a material for classification of particulate matter into various size fractions. The penetration characteristics of a nominal 90 pores per inch porous foam were studied at various flow rates, face velocities, and foam plug diameters and compared to the aerosol penetration of a 10 mm Dorr Oliver cyclone operated at 1.7 L/min. Poly-dispersed triethanolamine spheres were classified through porous foam plugs and the resulting penetration was determined using an aerodynamic particle sizer. Results showed that for a given plug diameter, as face velocity increased from 26 to 39 cm/sec, the 50 percent cut point decreased from 4.5 to 3.8 microns. Furthermore, as the diameter of the plug increased from 4 to 12 mm, the 50 percent cut points were similar to other plug diameters at equivalent face velocities. The best match to the 1.7 L/min cyclone penetration characteristics occurred at a flow rate of 250 ml/min through a 25 mm by 4 mm diameter section of 90 pore per inch foam. Because of the need to provide short-term or real-time estimates of worker respirable dust exposure, porous foam may be a viable classification media for a low flow rate, disposable respirable dust sampler for use in the coal mining industry.


Assuntos
Poluentes Ocupacionais do Ar/classificação , Carvão Mineral , Monitoramento Ambiental/instrumentação , Aerossóis , Poeira , Humanos , Exposição por Inalação , Mineração , Tamanho da Partícula , Porosidade
4.
AIHAJ ; 61(2): 275-81, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10782200

RESUMO

At a machining center used to produce transmission parts, aerosol instrumentation was used to quantitatively study mist generation and to evaluate the performance of an air cleaner for controlling the mist. This machining center drilled and tapped holes at rotational speeds of 1000 to 3000 rpm. During most machining operations, the metal-working fluid (MWF) was flooded over the part. To facilitate metal chip removal during some operations, MWF was pumped through the orifices in some tools at a pressure of 800 psi. These machining operations were performed in a nearly complete enclosure that was exhausted to an air cleaner at a flow rate of 1.1 m3/sec (2400 ft3/m). Although the use of high-pressure MWF increased the mist concentration by about 200%, it did not affect the mist size distribution. The observed penetration through the air cleaner appeared to be mostly consistent with the manufacturer's specifications on the air cleaner's filters. During the testing, MWF was observed to accumulate in the bottom of the filter housing and may have been reentrained due to air motion or mechanical vibration.


Assuntos
Aerossóis/análise , Poluentes Ocupacionais do Ar/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Metalurgia , Automóveis , Filtração/instrumentação , Indústrias , Exposição Ocupacional , Tamanho da Partícula
5.
Am J Physiol ; 276(3): L426-34, 1999 03.
Artigo em Inglês | MEDLINE | ID: mdl-10070106

RESUMO

Recent studies have demonstrated that dielectrophoresis is an efficient method for the separation of fibers according to fiber length. This method allows the investigation of fiber-cell interactions with fiber samples of the same composition but of different lengths. In the present study, we analyzed the effects of length on the interaction between glass fibers and macrophages by focusing on production of the inflammatory cytokine tumor necrosis factor (TNF)-alpha in a mouse macrophage cell line (RAW 264.7). The underlying molecular mechanisms controlling TNF-alpha production were investigated at the gene transcription level. The results show that glass fibers induced TNF-alpha production in macrophages and that this induction was associated with activation of the gene promoter. Activation of the transcription factor nuclear factor (NF)-kappaB was responsible for this induced promoter activity. The inhibition of both TNF-alpha production and NF-kappaB activation by N-acetyl-L-cysteine, an antioxidant, indicates that generation of oxidants may contribute to the induction of this cytokine and activation of this transcription factor by glass fibers. Long fibers (17 micrometer) were significantly more potent than short fibers (7 micrometer) in inducing NF-kappaB activation, the gene promoter activity, and the production of TNF-alpha. This fiber length-dependent difference in the stimulatory potency correlated with the fact that macrophages were able to completely engulf short glass fibers, whereas phagocytosis of long glass fibers was incomplete. These results suggest that fiber length plays a critical role in the potential pathogenicity of glass fibers.


Assuntos
Vidro , Macrófagos/metabolismo , Fatores de Transcrição/fisiologia , Fator de Necrose Tumoral alfa/biossíntese , Acetilcisteína/farmacologia , Animais , DNA/metabolismo , Sequestradores de Radicais Livres/farmacologia , Camundongos , NF-kappa B/antagonistas & inibidores , NF-kappa B/metabolismo , Peptídeos/metabolismo , Estimulação Física , Regiões Promotoras Genéticas/efeitos dos fármacos , Regiões Promotoras Genéticas/fisiologia , Fatores de Tempo , Fator de Necrose Tumoral alfa/genética
6.
J Toxicol Environ Health A ; 54(4): 243-59, 1998 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-9638898

RESUMO

Fiber length has been implicated as a determinant of fiber toxicity. Fibers of narrowly defined length can be generated by dielectrophoretic classifiers. Since the quantities of fibers produced are very small, we developed a rat alveolar macrophage microculture system to study the toxicity of these samples. The objective of this study was to examine the role of fiber length on the cytotoxicity of Manville code 100 (JM-100) fibers. Rat alveolar macrophages were cultured with 0-500 microg/ml of 5 lengths of JM-100 fibers on 96-well plates. After 18 h, well supernatants were removed and lactate dehydrogenase (LDH) activity was measured to assess cell damage. Chemiluminescence (CL), an assessment of macrophage function, was measured by adding lucigenin with or without zymosan, a particulate stimulus, to appropriate wells. For each fiber length the effects were concentration dependent: CL declined and LDH rose with increasing fiber concentration. Comparing the effects of different lengths showed the greatest toxicity from a relatively long fiber sample (mean length = 17 microm). Microscopic examination of the interaction of fibers with macrophages revealed multiple macrophages attached along the length of the long fibers. This suggests that frustrated, or incomplete, phagocytosis may be a factor in the increased toxicity of longer fibers. Overall the results demonstrate that length is an important determinant of toxicity for JM-100 fibers.


Assuntos
Vidro , Macrófagos Alveolares/patologia , Acridinas , Animais , Morte Celular , Células Cultivadas , Vidro/química , L-Lactato Desidrogenase/análise , Medições Luminescentes , Macrófagos Alveolares/enzimologia , Macrófagos Alveolares/metabolismo , Masculino , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Ratos , Ratos Sprague-Dawley , Testes de Toxicidade , Zimosan
7.
Am Ind Hyg Assoc J ; 51(2): 63-9, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2305675

RESUMO

A series of calculations was conducted to estimate the degree and type of electrostatic interactions that might occur with electrically charged asbestos samplers collecting charged particles. Relatively simple theoretical models were constructed assuming only charge-charge electrostatic interactions between a charged particle and a charged sampler. The results of these calculations were compared with some experimental measurements and the agreement between the two allowed some confidence in predicting behavior trends. Under conditions where both the particles and the sampler are charged, the nonconductive sampler exhibits increased particle loss, especially near the filter edge, and increased variability of the particle deposit. The variability of the deposit also tends to be greatest near the filter edge. Under similar conditions, conductive cowled samplers also can be expected to exhibit losses in particle deposit, especially near the filter edge. The variability over the filter surface, however, is less than for the nonconductive cowl. Particle collection onto the sampler filter generally is expected to be greatest for isokinetic, isoaxial sampling conditions. Particle collection on the filter decreases with lower sampling flow rates, lower air velocities near the sampler inlet, and increased turbulence near the inlet.


Assuntos
Poluentes Atmosféricos/análise , Amianto/análise , Eletricidade , Monitoramento Ambiental/métodos , Modelos Teóricos
8.
Am Ind Hyg Assoc J ; 51(2): 51-62, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2407082

RESUMO

Electrostatic charge can cause errors during sampling of airborne asbestos fibers and other particles. The change in particle trajectories caused by charge effects during sampling can result in nonuniform deposits on the collecting filter surface and net loss of sample. The degree of these electrostatic effects depends on particle charge, sampler charge, sampler conductivity, and sampling flow rate and direction. The purpose of this research was to evaluate the dependence of sampling efficiency and sample uniformity on these variables. Humidity has been postulated as a primary determinant of particle charge during aerosol generation. Measurements of particle charge and concentration were made as a function of relative humidity with chrysotile fibers generated from a fluidized bed. A strong increase in charge and a decrease in concentration of fibers was noted as the relative humidity was decreased below 15%. The effects of conductive versus nonconductive samplers and sampling flow rate were measured as a function of particle and sampler charge levels. Nonconductive samplers can carry a large and variable charge distribution on their surfaces. This can result in a biased and highly variable particle deposit on the filter when sampling charged particles. Conductive cowls spread any acquired charge over the entire surface and produce a more symmetrical and less biased charged particle deposit. Increasing the sampling flow rate will improve sampling efficiency and decrease deposit variability because the charged particle has less time to interact with the field produced by the sampler. These results suggest that sampling problems caused by electrostatic charge interactions are most likely to occur under low humidity conditions of dust generation, that sampling should be done at as high a flow rate as possible to reduce these effects, and that analysts should select fields toward the center of the filter to minimize bias and variability.


Assuntos
Poluentes Atmosféricos/análise , Amianto/análise , Eletricidade , Monitoramento Ambiental/métodos , Aerossóis/análise , Condutividade Elétrica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...