Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 15(12): e50611, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38226095

RESUMO

Background and objective The risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission from patients with coronavirus disease 2019 (COVID-19) during nebulization is unclear. In this study, we aimed to address this issue. Methods Fugitive emissions of aerosolized saline during nebulization were observed using a standard jet nebulizer fitted with unfiltered and filtered mouthpieces connected via a mannequin to a breathing simulator. Fugitive emissions were observed by using a laser sheet and captured on high-definition video, and they were measured by using optical particle counters positioned where a potential caregiver may be administering nebulization and three other locations in the sagittal plane at various distances downstream of the mannequin. Results The use of a standard unfiltered mouthpiece resulted in significant emission of fugitive aerosols ahead of and above the mannequin (spread over 2 m in front). A mouthpiece with a filter-adaptor effectively suppressed the emissions, with only minor leakage from the nebulizer cup. Particle count measurements supported the visual observations, providing total particle count levels and aerosol concentration levels at the measurement locations. The levels decayed slowly with downstream distance. Conclusions The visualization described above captured the dispersion of emitted aerosols in the plane of the laser sheet, aligned with the sagittal plane. The particle count measurements provided temporal and spatial distributions of the aerosol concentration levels over the time and locations considered. However, the exhaled air and aerosolized droplets spread three-dimensionally in front of and above the mannequin. The results visually highlight the effectiveness of using a filtered mouthpiece in suppressing the fugitive aerosols and identify an approach for limiting the occupational exposure of healthcare workers to these emissions while administering nebulized therapies.

2.
Phys Fluids (1994) ; 33(3): 033320, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33897239

RESUMO

Aerosolized droplets play a central role in the transmission of various infectious diseases, including Legionnaire's disease, gastroenteritis-causing norovirus, and most recently COVID-19. Respiratory droplets are known to be the most prominent source of transmission for COVID-19; however, alternative routes may exist given the discovery of small numbers of viable viruses in urine and stool samples. Flushing biomatter can lead to the aerosolization of micro-organisms; thus, there is a likelihood that bioaerosols generated in public restrooms may pose a concern for the transmission of COVID-19, especially since these areas are relatively confined, experience heavy foot traffic, and may suffer from inadequate ventilation. To quantify the extent of aerosolization, we measure the size and number of droplets generated by flushing toilets and urinals in a public restroom. The results indicate that the particular designs tested in the study generate a large number of droplets in the size range 0.3 µ m - 3 µ m , which can reach heights of at least 1.52 m. Covering the toilet reduced aerosol levels but did not eliminate them completely, suggesting that aerosolized droplets escaped through small gaps between the cover and the seat. In addition to consistent increases in aerosol levels immediately after flushing, there was a notable rise in ambient aerosol levels due to the accumulation of droplets from multiple flushes conducted during the tests. This highlights the need for incorporating adequate ventilation in the design and operation of public spaces, which can help prevent aerosol accumulation in high occupancy areas and mitigate the risk of airborne disease transmission.

3.
Environ Plan B Urban Anal City Sci ; 48(5): 1126-1143, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38222247

RESUMO

US ports and container/intermodal terminals are critical links in the marine transportation system. Disruption at a port can have a crippling economic effect in the coastal zone as well as the rest of the nation. Port stakeholders have a vested interest in the long-term function and viability of ports, but no standardized measures for performance or resilience exist for ports. The goal of this research is to demonstrate the utility of a predictive port resilience assessment tool. The developed tool encompasses a microscopic traffic simulation model (VISSIM) based hybrid multimodal analyzes of port operations and provides a quantifiable assessment of resilience. The application of this tool is shown on six ports in the Southeast US. The waterside port simulation models were developed using vessel automatic identification system data and programed within a VISSIM simulation of landside operations. This hybrid modeling approach was used to visualize vessels and allow them to interact in both time and space with each other and landside infrastructure. Local and regional resilience was quantified through the analysis of time-dependent resilience plots and used as a performance measure in this study. The utility of the predictive port resilience assessment was demonstrated in response to Hurricane Matthew (2016). However, the novel procedure described herein can be applied to any port hazard. This research grows the understanding of the regional consequences of hurricane events and enhances the knowledge in the development of a stakeholder-focused tool to assess resilience.

4.
Phys Fluids (1994) ; 32(9): 091701, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32952381

RESUMO

Several places across the world are experiencing a steep surge in COVID-19 infections. Face masks have become increasingly accepted as one of the most effective means for combating the spread of the disease when used in combination with social-distancing and frequent hand-washing. However, there is an increasing trend of people substituting regular cloth or surgical masks with clear plastic face shields and with masks equipped with exhalation valves. One of the factors driving this increased adoption is improved comfort compared to regular masks. However, there is a possibility that widespread public use of these alternatives to regular masks could have an adverse effect on mitigation efforts. To help increase public awareness regarding the effectiveness of these alternative options, we use qualitative visualizations to examine the performance of face shields and exhalation valves in impeding the spread of aerosol-sized droplets. The visualizations indicate that although face shields block the initial forward motion of the jet, the expelled droplets can move around the visor with relative ease and spread out over a large area depending on light ambient disturbances. Visualizations for a mask equipped with an exhalation port indicate that a large number of droplets pass through the exhale valve unfiltered, which significantly reduces its effectiveness as a means of source control. Our observations suggest that to minimize the community spread of COVID-19, it may be preferable to use high quality cloth or surgical masks that are of a plain design, instead of face shields and masks equipped with exhale valves.

5.
Phys Fluids (1994) ; 32(6): 061708, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32624649

RESUMO

The use of face masks in public settings has been widely recommended by public health officials during the current COVID-19 pandemic. The masks help mitigate the risk of cross-infection via respiratory droplets; however, there are no specific guidelines on mask materials and designs that are most effective in minimizing droplet dispersal. While there have been prior studies on the performance of medical-grade masks, there are insufficient data on cloth-based coverings, which are being used by a vast majority of the general public. We use qualitative visualizations of emulated coughs and sneezes to examine how material- and design-choices impact the extent to which droplet-laden respiratory jets are blocked. Loosely folded face masks and bandana-style coverings provide minimal stopping-capability for the smallest aerosolized respiratory droplets. Well-fitted homemade masks with multiple layers of quilting fabric, and off-the-shelf cone style masks, proved to be the most effective in reducing droplet dispersal. These masks were able to curtail the speed and range of the respiratory jets significantly, albeit with some leakage through the mask material and from small gaps along the edges. Importantly, uncovered emulated coughs were able to travel notably farther than the currently recommended 6-ft distancing guideline. We outline the procedure for setting up simple visualization experiments using easily available materials, which may help healthcare professionals, medical researchers, and manufacturers in assessing the effectiveness of face masks and other personal protective equipment qualitatively.

6.
Bioelectromagnetics ; 39(1): 35-52, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29119574

RESUMO

The objective of this study was to determine if electromagnetic field (EMF) emissions from undersea power cables impacted local marine life, with an emphasis on coral reef fish. The work was done at the South Florida Ocean Measurement Facility of Naval Surface Warfare Center in Broward County, Florida, which has a range of active undersea detection and data transmission cables. EMF emissions from a selected cable were created during non-destructive visual fish surveys on SCUBA. During surveys, the transmission of either alternating current (AC), direct current (DC), or none (OFF) was randomly initiated by the facility at a specified time. Visual surveys were conducted using standardized transect and point-count methods to acquire reef fish abundances and species richness prior to and immediately after a change in transmission frequency. The divers were also tasked to note the reaction of the reef fish to the immediate change in EMF during a power transition. In general, analysis of the data did not find statistical differences among power states and any variables. However, this may be a Type II error as there are strong indications of a potential difference of a higher abundance of reef fish at the sites when the power was off, and further study is warranted. Bioelectromagnetics. 39:35-52, 2018. © 2017 Wiley Periodicals, Inc.


Assuntos
Recifes de Corais , Campos Eletromagnéticos/efeitos adversos , Peixes , Oceanos e Mares , Centrais Elétricas , Animais , Comportamento Animal/efeitos da radiação , Biodiversidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA