Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiovasc Electrophysiol ; 30(11): 2397-2404, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31424119

RESUMO

AIMS: The use of electroanatomical mapping (EAM) systems can reduce radiation exposure (RX) and it can also completely eliminate the use of RX. Radiation exposure related to conventional radiofrequency ablation procedures can have a stochastic and deterministic effect on health. The main aim of this study was to evaluate the safety and feasibility of an entirely nonfluoroscopic approach to catheter ablation (CA) using EAM CARTO3. METHODS: In 2011 we started an RX-minimization programme in all procedures using the CARTO system with the deliberate intention to not resort to the aid of RX unless strictly necessary. We divided procedures into two groups (group 1: from 2011 to 2013; group 2: from 2014 to 2017). The only exclusion criteria were the need for transseptal puncture, and nonidiopathic ventricular tachycardia (VT). RESULTS: From a total of 525 procedures, we performed CA entirely without RX in 78.5% of cases. From 2011 to 2013, we performed CA without RX in 38.5% of cases; from 2014 to 2017, we performed 96.2% of cases with zero RX. The use of RX was significantly reduced in group 2 (group 2: 1.4 ± 19.6 seconds vs group 1: 556.92 ± 520.76 seconds; P < .001). These differences were irrespective of arrhythmia treatment. There were no differences between the two groups in acute success, complications, or duration of procedures. CONCLUSION: CA of supraventricular tachycardia and VT entirely without RX, guided by the CARTO system, is safe, feasible, and effective. After an adequate learning curve, CA can be performed entirely without RX.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Cirurgia Assistida por Computador , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Competência Clínica , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Cirurgia Assistida por Computador/instrumentação , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
2.
Int J Cardiol ; 190: 338-43, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25935624

RESUMO

BACKGROUND: Catheter ablation is the treatment of choice for many patients with idiopathic ventricular tachycardia (VT). Unfortunately, conventional catheter ablation is guided by fluoroscopy, which is associated with a small but definite radiation risk for patients and laboratory personnel. The aim of our study is to assess feasibility, success rate and safety of idiopathic VT ablation procedure performed without the use of fluoroscopy. METHODS: Nineteen consecutive patients undergoing idiopathic VT ablation at our institution have been included. The ablation procedures were performed under the guidance of electroanatomical mapping (EAM) system and intracardiac echocardiography (ICE). RESULTS: Nineteen patients (mean age 38.7 years) underwent ablation procedure for idiopathic VT. Twelve (63%) had outflow tract VT, 3 (18%) fascicular tachycardia, 2 (11%) peri-tricuspidal VT, 1 (5%) peri-mitral VT, and 1 (5%) lateral left free-wall VT. The mean procedural time was 170.2 ± 45.7 min. No fluoroscopy was used in any procedural phase. Acute success rate was 100%. No complication was documented in any patients. After a mean follow up of 18 ± 4 months, recurrences occurred in 2 patients. CONCLUSIONS: In our preliminary experience idiopathic VT ablation without the use of fluoroscopy was feasible and safe, using a combination of EAM and ICE. Success rate was excellent with no complication.


Assuntos
Ablação por Cateter/métodos , Fluoroscopia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Pacing Clin Electrophysiol ; 38(6): 675-81, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25727697

RESUMO

BACKGROUND: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients. METHODS: We included 44 patients (mean age: 13.1 ± 3.3 years); nine of 44 presented concealed AP. An electrophysiological study with a three-dimensional EAM reconstruction was performed in every patient with a venous transfemoral direct right atrium approach or an arterial transfemoral retrograde approach to reach the mitral annulus. In two patients with left-sided AP, the ablation was performed via a patent foramen ovale. RESULTS: A total of 47 APs were present, left sided in 45% (21/47) of cases (15 lateral, one anterior, three posteroseptal, and two posterolateral) and right sided in 55% (26/47; one anterior, three anterolateral, one posterolateral, three lateral, five para-Hisian, 12 posteroseptal, and one anteroseptal). Ablation without the use of fluoroscopy was successfully performed in every patient (33 with RF and in 11 with cryoenergy). No complication occurred. At a mean follow-up of 16.0 ± 11.7 months, we observed seven recurrences, three of them successfully re-ablated without fluoroscopy. In one case cryoablation of a para-Hisian AP was ineffective in the long term. CONCLUSIONS: Three-dimensional EAM allowed a safe and effective fluoroless AP ablation procedure in a pediatric population both with RF and cryoenergy.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Adolescente , Criança , Criocirurgia , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Segurança do Paciente , Ondas de Rádio , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 25(12): 1299-305, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25066687

RESUMO

BACKGROUND: Simultaneous multipolar ablation catheters have been proposed to simplify pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (AF). Recently, a new multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™, Biosense Webster Inc., Diamond Bar, CA, USA) combining both 3-dimensional electroanatomic mapping and multipolar open-irrigated ablation capability has been developed. Aim of our study was to assess feasibility, acute and short-term success and safety of PVI by the use of this new technology with particular regard to the incidence of postablation silent cerebral ischemia (SCI). METHODS AND RESULTS: Twenty-five patients (76% males; age 57 ± 13 years) with paroxysmal AF underwent PVI using the nMARQ™ catheter. PVI, confirmed by Lasso catheter mapping, was achieved in 100 out of 102 pulmonary veins (98%) identified, and final PVI was obtained in 24 out of 25 (96%) patients. The overall concordance between Lasso and nMARQ™ signals in demonstrating PVI was 78%. No major procedural complications occurred and no patient suffered SCI, on the basis of cerebral magnetic resonance imaging performed before and after the procedure. Following a 6-month follow-up, 17/25 (68%) patients remained free from AF without antiarrhythmic drugs. CONCLUSIONS: In our preliminary experience, PVI with nMARQ™ catheter appears to be feasible and safe, without incidence of SCI. Long-term clinical efficacy has to be evaluated in further studies.


Assuntos
Fibrilação Atrial/cirurgia , Isquemia Encefálica/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Fibrilação Atrial/diagnóstico , Isquemia Encefálica/diagnóstico , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Irrigação Terapêutica/efeitos adversos , Resultado do Tratamento
5.
Europace ; 16(12): 1800-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24843050

RESUMO

AIMS: Atrial tachycardias are common after repair of atrial septal defect (ASD). Although ablation has shown promising results in the short and mid-term follow-up, little data regarding the very long-term success exist. Our aim was to assess very long-term follow-up in patients who have undergone electroanatomic-guided radiofrequency (RF) ablation of late-onset atrial arrhythmias after ASD surgery. METHODS AND RESULTS: Forty-six consecutive patients with surgically repaired ASD were referred for atrial tachycardia ablation. Electrophysiological (EP) study and ablation procedure with the aid of an electroanatomic mapping (EAM) system were performed. Mean age was 49 ± 13 years (females 61%). The presenting arrhythmias were typical atrial flutter (48%), atypical atrial flutter (35%), and atrial tachycardia (17%). In 41% of patients, atrial fibrillation was also present. The EP study showed a right atrial macroreentrant circuit in all the patients. In 12 of 46 (26%), the circuit was localized in the cavo-tricuspid isthmus, whereas in the remaining 34 patients (74%) was atriotomy-dependent. Acute success was 100%. Clinical arrhythmia recurred in 24% of the patients. Nine patients underwent a second and two a third ablation procedure, reaching an overall efficacy of 87% (40 of 46) at a mean follow-up of 7.3 ± 3.8 years since the last procedure. With antiarrhythmic drugs the success rate increased to 96% (44 of 46). No complications occurred. CONCLUSION: In patients with surgically corrected ASD, EAM-guided RF ablation of late-onset macroreentrant atrial arrhythmias demonstrated a high success rate in a very long-term follow-up. Therefore, RF ablation could be considered early in the management of late-onset macroreentrant atrial tachycardias.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Comunicação Interatrial/cirurgia , Cirurgia Assistida por Computador/métodos , Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
J Am Coll Cardiol ; 61(13): 1398-405, 2013 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-23500279

RESUMO

OBJECTIVES: The goal of this study was to compare transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) for the diagnosis of cardiac device-related endocarditis (CDI). BACKGROUND: The diagnosis of infective endocarditis (IE) was established by using the modified Duke criteria based mainly on echocardiography and blood culture results. No previous studies have compared ICE with TEE for the diagnosis of IE. METHODS: We prospectively enrolled 162 patients (age 72 ± 11 years; 125 male) who underwent transvenous lead extraction: 152 with CDI and 10 with lead malfunction (control group). Using the modified Duke criteria, we divided the patients with infection into 3 groups: 44 with a "definite" diagnosis of IE (group 1), 52 with a "possible" diagnosis of IE (group 2), and 56 with a "rejected" diagnosis of IE (group 3). TEE and ICE were performed before the procedure. RESULTS: In group 1, ICE identified intracardiac masses (ICM) in all 44 patients; TEE identified ICM in 32 patients (73%). In group 2, 6 patients (11%) had ICE and TEE both positive for ICM, 8 patients (15%) had a negative TEE but a positive ICE, and 38 patients (73%) had ICE and TEE both negative. In group 3, 2 patients (3%) had ICM both at ICE and TEE, 1 patient (2%) had an ICM at ICE and a negative TEE, and 53 patients (95%) had no ICM at ICE and TEE. ICE and TEE were both negative in the control group. CONCLUSIONS: ICE represents a useful technique for the diagnosis of ICM, thus providing improved imaging of right-sided leads and increasing the diagnostic yield compared with TEE.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Endocardite/diagnóstico , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/microbiologia , Ecocardiografia Transesofagiana , Eletrodos Implantados/microbiologia , Endocardite/etiologia , Endocardite/microbiologia , Feminino , Próteses Valvulares Cardíacas/microbiologia , Humanos , Masculino , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Índice de Gravidade de Doença
7.
Am J Cardiol ; 102(2): 146-9, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18602511

RESUMO

Experimental studies suggest that alcohol may have protective effects similar to that of ischemic preconditioning (IPC). The acute effects of alcohol on IPC in humans, however, are poorly known. In this study, we assessed the effect of alcohol administration on the warm-up phenomenon, as an expression of IPC, in patients with stable coronary artery disease (CAD). We randomized 45 stable CAD patients with positive (ST-segment depression > or =1 mm) exercise stress test to 1 of 3 groups of 15 patients each: (1) group 1 = 60 cc of gin (18.5 g of ethanol); (2) group 2 = 180 cc of red wine (18.9 g of ethanol); and (3) group 3 = placebo (120 cc of water). A first exercise test was performed 15 minutes after beverage administration. In those with a positive exercise test (13, 14, and 14 patients in the gin, wine, and placebo groups, respectively), a second exercise test was performed 15 minutes after the end of the first one. On the first test, there were no differences among groups in rate pressure product and time of exercise at 1-mm ST-segment depression, as well as in maximal ST segment depression. Furthermore, an improvement of the ischemic exercise variables was observed in each group, without any statistically significant differences among them. In conclusion, our data show that, in stable CAD patients, the acute intake of low doses of alcohol does not significantly influence IPC, as expressed by the warm-up phenomenon on exercise stress testing.


Assuntos
Consumo de Bebidas Alcoólicas , Angina Pectoris/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Etanol/administração & dosagem , Etanol/farmacologia , Precondicionamento Isquêmico Miocárdico/métodos , Idoso , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Neuroimmunomodulation ; 14(6): 331-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18418007

RESUMO

OBJECTIVE: Recent data suggest that vagus nerve stimulation (VNS) can inhibit cytokine release by inflammatory cells. Accordingly, an association between impaired cardiac parasympathetic function, as assessed by heart rate variability (HRV), and increased markers of inflammation has recently been reported. In this study we assessed the effect of direct left VNS on inflammatory markers and HRV in patients with refractory epilepsy. METHODS: A 24-hour electrocardiogram Holter recording was performed both at baseline and after 3 months of left VNS in 8 patients (age 32 +/- 24 years, 2 men) who underwent implantation of a VNS device because of refractory epilepsy. Tumor necrosis factor-alpha, interleukin-6 and C-reactive protein serum levels were measured, as markers of inflammation, at the same times. RESULTS: No significant changes were found after 3 months of left VNS, compared to baseline, both for HRV variables and inflammatory markers. Also, no consistent correlation could be demonstrated between HRV parameters and inflammatory markers in these patients. CONCLUSIONS: Our data in epileptic patients without cardiovascular disease failed to show a significant effect of left VNS on cardiac autonomic function and on systemic inflammation at short-term follow-up.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Terapia por Estimulação Elétrica , Epilepsia/terapia , Coração/fisiologia , Inflamação/sangue , Nervo Vago/fisiologia , Adolescente , Adulto , Idoso , Proteína C-Reativa/análise , Criança , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca/fisiologia , Humanos , Interleucina-6/sangue , Masculino , Neuroimunomodulação/fisiologia , Fator de Necrose Tumoral alfa/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...