Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 9(3): e92730, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24675965

RESUMO

The aim of the study was to investigate the Internal Jugular Veins dynamics using contrast enhanced ultrasonography in Multiple Sclerosis patients, clinically isolated syndrome patients and healthy controls. Contrast enhanced ultrasonography imaging of the Internal Jugular Vein was performed in fifty-eight patients with Multiple Sclerosis, seven clinically isolated syndrome patients and in thirteen healthy controls. Time-intensity curves were quantified using a semi-automated method and compared with clinical disease outcomes. Wash-out parameters were calculated and six Time-intensity curves shapes were created. Significantly reduction of wash-out rate in Internal Jugular Veins was detected in Multiple Sclerosis patients compared to healthy controls [22.2% (2.7%-65.9%) vs. 33.4% (16.2%-76.8%); P<0.005]. Internal Jugular Vein enhancement was heterogeneous in patients with Multiple Sclerosis and consisted of slow wash-out Time-intensity curves shapes, compared with almost only one type of Time-intensity curves shape in control subjects that correspond to fast enhancement and fast wash-out. The vein wash-in parameters were similar in Multiple Sclerosis group compared with controls. A significant correlation was found between Internal Jugular Vein wash-out and level of disability (R =  -0.402, p<0.05). Contrast enhanced ultrasonography of the Internal Jugular Vein with time intensity curve analysis revealed alterations of cerebral venous outflow in Multiple Sclerosis patients, however mechanisms that determine this condition remains unclear.


Assuntos
Hemodinâmica , Veias Jugulares , Esclerose Múltipla/sangue , Esclerose Múltipla/fisiopatologia , Fluxo Sanguíneo Regional , Adulto , Idade de Início , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Adulto Jovem
2.
Radiol Med ; 118(7): 1109-18, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23716293

RESUMO

PURPOSE: This study sought to determine the prevalence of extramammary findings on magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS: We retrospectively reviewed the data sets of 828 consecutive patients (F/M; 821/7; mean age, 50 ± 11 years) who underwent breast MR imaging. The most common clinical indication was assessment of lesion extent in patients with known breast tumour (n=380, 46%), characterisation of equivocal findings at conventional imaging (n=331, 40%), evaluation of women at high risk for breast cancer (n=43, 5%) and following breast augmentation therapy (n=74, 9%). RESULTS: Collateral findings were found in 282/828 (34%) patients. In those 282 patients, 480 incidental lesions were detected. The most common localisation was the liver (231/480; 48%). Of the 480 collateral findings, 66 (14% in 38 patients) were classified as significant and deserving further investigation. These comprised 26 metastatic bony lesions, 15 mediastinal/axillary lymph nodes, six metastatic lung lesions, five metastatic liver lesions, four pneumonitis, two aneurysms of the ascending aorta, two adrenal adenomas, one neurofibroma of the back, one multiple myeloma, one mediastinal lymphoma, one sternal amyloidosis, one left ventricular dilatation and one trapezium lipoma. CONCLUSIONS: There is a high prevalence of extramammary findings on breast MR imaging. Evaluation of the examination should focus not only on the breast fields but also consider extramammary findings to avoid inappropriate management and possible legal issues.


Assuntos
Doenças Mamárias/diagnóstico , Achados Incidentais , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Mamografia , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia Mamária
3.
BMC Neurol ; 13: 20, 2013 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-23406210

RESUMO

BACKGROUND: This study aimed to investigate the prevalence and clinical relevance of chronic cerebrospinal venous insufficiency (CCSVI) in multiple sclerosis (MS) patients and healthy controls using extra- and intracranial colour Doppler sonography. METHODS: We examined 146 MS patients, presenting with a clinically isolated syndrome, relapsing-remitting, secondary progressive, or primary progressive MS, and 38 healthy controls. Sonographic examination was performed according to Zamboni's protocol and was performed by three independent sonographers. The results of sonographic examination were compared with clinical and demographic characteristics of the patients. RESULTS: CCSVI, defined as the presence of at least two positive Zamboni's criteria, was found in 76% of MS patients and 16% of control subjects. B-mode anomalies of internal jugular veins, such as stenosis, malformed valves, annuli, and septa were the most common lesions detected in MS patients (80.8%) and controls (47.4%). We observed a positive correlation between sonographic diagnosis of CCSVI and the patients' age (p = 0.003). However, such a correlation was not found in controls (p = 0.635). Notably, no significant correlations were found between sonographic signs of CCSVI and clinical characteristics of MS, except for absent flow in the jugular veins, which was found more often in primary (p<0.005) and secondary (p<0.05) progressive patients compared with non-progressive patients. Absent flow in jugular veins was significantly correlated with patients' age (p < 0.0001). CONCLUSIONS: Sonographically defined CCSVI is common in MS patients. However, CCSVI appears to be primarily associated with the patient's age, and poorly correlated with the clinical course of the disease.


Assuntos
Esclerose Múltipla/complicações , Esclerose Múltipla/epidemiologia , Insuficiência Venosa/epidemiologia , Insuficiência Venosa/etiologia , Adulto , Fatores Etários , Estudos de Casos e Controles , Avaliação da Deficiência , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Prevalência , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Ultrassonografia Doppler em Cores , Insuficiência Venosa/diagnóstico por imagem
4.
Radiology ; 262(3): 947-55, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22357894

RESUMO

PURPOSE: To assess cerebral circulation times (CCTs) in patients with multiple sclerosis (MS) and control subjects by using contrast material-enhanced ultrasonography (US) to determine whether vascular abnormalities can be detected in this disease. MATERIALS AND METHODS: This study was approved by the local ethics committee, and informed consent was obtained from all subjects. One hundred three patients with MS and 42 control subjects underwent extracranial and transcranial venous echo-color Doppler ultrasonography (US) and contrast-enhanced US. CCT was defined as the difference in arrival time of the US contrast agent bolus between the carotid artery and the internal jugular vein. The presence of chronic cerebrospinal venous insufficiency (CCSVI) was defined according to previously reported criteria for the extracranial and transcranial US techniques. Nonparametric statistics, including the Mann-Whitney U test and the Kruskal-Wallis analysis of variance, were used to compare contrast-enhanced US parameters between groups. RESULTS: The longest and average CCTs were substantially prolonged in patients with MS compared with those in control subjects (median longest CCT in patients with MS, 6.47 seconds [range, 3.29-29.24 seconds]; that in control subjects, 5.54 seconds [range, 2.57-7.63 seconds]; P < .001; median average CCT in patients with MS, 5.76 seconds [range, 2.64-17.51 seconds]; that in control subjects, 5.01 seconds [range, 2.57-7.06 seconds]; P < .002). No correlation was found between CCTs and clinical parameters. The prevalence of CCSVI was higher in patients with MS than in control subjects (77% vs 28%, P < .0001). CCT was not significantly different between patients with MS who had CCSVI and patients with MS who did not (P = .182). CONCLUSION: These results suggest that contrast-enhanced US with CCT assessment may have a role in the evaluation of cerebral blood flow in patients with MS and that a vascular impairment could be associated with MS. The finding of a prolonged CCT at contrast-enhanced US does not result from outflow impairment. Further studies are required to verify these observations and to clarify if CCT and CCSVI have any physiologic and clinical relevance in MS.


Assuntos
Circulação Cerebrovascular/fisiologia , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/fisiopatologia , Ultrassonografia Doppler Transcraniana , Adulto , Idoso , Análise de Variância , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fosfolipídeos , Estudos Prospectivos , Estatísticas não Paramétricas , Hexafluoreto de Enxofre
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...