1.
J Perinatol ; 44(2): 266-272, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38007593

RESUMO

OBJECTIVE: To investigate a novel servo pressure (SP) setting during high-frequency jet ventilation (HFJV) for a lung protective strategy in a neonatal model of acute respiratory distress. STUDY DESIGN: Comparison of efficacy between variable (standard) and fixed SP settings in a randomized animal study using rabbits (n = 10, mean weight = 1.80 kg) with surfactant deficiency by repeated lung lavages. RESULTS: Rabbits in the fixed SP group had greater peak inspiratory pressure, SP, minute volume, pH, and PaO2, and lower PaCO2 after lung lavage than the variable SP group. Lung volume monitoring with electrical impedance tomography showed that fixed SP reduced the decline of the global lung tidal variation at 30 min after lung lavage (-17.4% from baseline before lavage) compared to variable SP (-44.9%). CONCLUSION: HFJV with fixed SP significantly improved gas exchange and lung volumes compared to variable SP. Applying a fixed SP may have important clinical implications for patients receiving HFJV.


Assuntos
Ventilação em Jatos de Alta Frequência , Ventilação de Alta Frequência , Surfactantes Pulmonares , Animais , Humanos , Coelhos , Tensoativos , Pulmão , Medidas de Volume Pulmonar , Respiração Artificial/métodos
2.
Pharmaceutics ; 15(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37896128

RESUMO

Aerosolized lung surfactant therapy during nasal continuous positive airway pressure (CPAP) support avoids intubation but is highly complex, with reported poor nebulizer efficiency and low pulmonary deposition. The study objective was to evaluate particle size, operational compatibility, and drug delivery efficiency with various nasal CPAP interfaces and gas humidity levels of a synthetic dry powder (DP) surfactant aerosol delivered by a low-flow aerosol chamber (LFAC) inhaler combined with bubble nasal CPAP (bCPAP). A particle impactor characterized DP surfactant aerosol particle size. Lung pressures and volumes were measured in a preterm infant nasal airway and lung model using LFAC flow injection into the bCPAP system with different nasal prongs. The LFAC was combined with bCPAP and a non-heated passover humidifier. DP surfactant mass deposition within the nasal airway and lung was quantified for different interfaces. Finally, surfactant aerosol therapy was investigated using select interfaces and bCPAP gas humidification by active heating. Surfactant aerosol particle size was 3.68 µm. Lung pressures and volumes were within an acceptable range for lung protection with LFAC actuation and bCPAP. Aerosol delivery of DP surfactant resulted in variable nasal airway (0-20%) and lung (0-40%) deposition. DP lung surfactant aerosols agglomerated in the prongs and nasal airways with significant reductions in lung delivery during active humidification of bCPAP gas. Our findings show high-efficiency delivery of small, synthetic DP surfactant particles without increasing the potential risk for lung injury during concurrent aerosol delivery and bCPAP with passive humidification. Specialized prongs adapted to minimize extrapulmonary aerosol losses and nasal deposition showed the greatest lung deposition. The use of heated, humidified bCPAP gases compromised drug delivery and safety. Safety and efficacy of DP aerosol delivery in preterm infants supported with bCPAP requires more research.

3.
J Breath Res ; 17(3)2023 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-36996807

RESUMO

Although pressurized metered dose inhaler (pMDI) education is a routine part of childhood asthma management and encouraging 'optimal breathing patterns' (i.e. slowly, deeply, completely, and with a mouth seal on the mouthpiece) is an integral part of recommended pMDI education, there is currently no quantifiable way to determine if a child is inhaling their medication correctly or optimally through a valved holding chamber (VHC). The TipsHaler™ (tVHC) is a prototype VHC device that measures inspiratory time, flow, and volume without changing the properties of the medication aerosol. The measurementsin vivorecorded by the tVHC can be downloaded and transferred to a spontaneous breathing lung model to simulate the inhalational patternsin vitroand also determine the deposition of inhaled aerosol mass with each pattern. We hypothesized that pediatric patients' inhalational patterns when using a pMDI would improve after active coaching via tVHC. This would increase the pulmonary deposition of inhaled aerosols in anin vitromodel. To test this hypothesis, we conducted a single-site, prospective, pilot, pre-and-post intervention study paired with a bedside-to-bench experiment. Healthy, inhaler-naïve subjects used a placebo inhaler in conjunction with the tVHC before and after coaching and recorded inspiratory parameters. These recordings were then implemented into a spontaneous breathing lung model during albuterol MDI delivery, and pulmonary deposition of albuterol was quantified. In this pilot study, active coaching resulted in a statistically significant increase in inspiratory time (n= 8,p= 0.0344, 95%CI: 0.082 to ∞). tVHC recorded inspiratory parameters obtained from patients were successfully implemented in thein vitromodel, which demonstrated that both inspiratory time (n= 8,r= 0.78,p <0.001, 95%CI: 0.47-0.92) and volume (n= 8,r= 0.58,p =0.0186, 95%CI: 0.15-0.85) strongly correlate with pulmonary deposition of inhaled drugs.


Assuntos
Tutoria , Criança , Humanos , Projetos Piloto , Estudos Prospectivos , Broncodilatadores , Sistemas de Liberação de Medicamentos/métodos , Testes Respiratórios , Aerossóis e Gotículas Respiratórios , Nebulizadores e Vaporizadores , Inaladores Dosimetrados , Administração por Inalação , Albuterol , Aerossóis , Desenho de Equipamento
4.
Bioengineering (Basel) ; 9(4)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35447711

RESUMO

The COVID-19 pandemic has brought attention to the need for developing effective respiratory support that can be rapidly implemented during critical surge capacity scenarios in healthcare settings. Lung support with bubble continuous positive airway pressure (B-CPAP) is a well-established therapeutic approach for supporting neonatal patients. However, the effectiveness of B-CPAP in larger pediatric and adult patients has not been addressed. Using similar principles of B-CPAP pressure generation, application of intermittent positive pressure inflations above CPAP could support gas exchange and high work of breathing levels in larger patients experiencing more severe forms of respiratory failure. This report describes the design and performance characteristics of the BubbleVent, a novel 3D-printed valve system that combined with commonly found tubes, hoses, and connectors can provide intermittent mandatory ventilation (IMV) suitable for adult mechanical ventilation without direct electrification. Testing of the BubbleVent was performed on a passive adult test lung model and compared with a critical care ventilator commonly used in tertiary care centers. The BubbleVent was shown to deliver stable PIP and PEEP levels, as well as timing control of breath delivery that was comparable with a critical care ventilator.

5.
Respir Res ; 23(1): 78, 2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35379243

RESUMO

BACKGROUND: Dry powder (DP) synthetic lung surfactant may be an effective means of noninvasive delivery of surfactant therapy to premature infants supported with nasal continuous positive airway pressure (nCPAP) in low-resource settings. METHODS: Four experimental DP surfactant formulations consisting of 70% of phospholipids (DPPC:POPG 7:3), 3% Super Mini-B (SMB) or its sulfur-free derivate B-YL as SP-B peptide mimic, 25% of lactose or trehalose as excipient, and 2% of NaCl were formulated using spray drying. In vitro surface activity was confirmed with captive bubble surfactometry. Surfactant particle size was determined with a cascade impactor and inhaled dose was quantified using a spontaneously breathing premature lamb lung model supported with CPAP. In vivo surfactant efficacy was demonstrated in three studies. First, oxygenation and lung compliance were monitored after intratracheal instillation of resuspended DP surfactant in intubated, ventilated, lavaged, surfactant-deficient juvenile rabbits. In dose-response studies, ventilated, lavaged, surfactant-deficient rabbits received 30, 60, 120 or 240 mg/kg of DP B-YL:Lactose or B-YL:Trehalose surfactant by aerosol delivery with a low flow aerosol chamber via their endotracheal tube. Noninvasive aerosolization of DP B-YL:Trehalose surfactant via nasal prongs was tested in spontaneous breathing premature lambs supported with nCPAP. Intratracheal administration of 200 mg/kg of Curosurf®, a liquid porcine surfactant, was used as a positive control. RESULTS: Mass median aerosol diameter was 3.6 µm with a geometric standard deviation of 1.8. All four experimental surfactants demonstrated high surface efficacy of intratracheal instillation of a bolus of ~ 100 mg/kg of surfactant with improvement of oxygenation and lung compliance. In the dose-response studies, rabbits received incremental doses of DP B-YL:Lactose or B-YL:Trehalose surfactant intratracheally and showed an optimal response in oxygenation and lung function at a dose of 120-240 mg/kg. Aerosol delivery via nasal prongs of 1 or 2 doses of ~ 100 mg/kg of B-YL:Trehalose surfactant to premature lambs supported with nCPAP resulted in stabilization of spontaneous breathing and oxygenation and lung volumes comparable to the positive control. CONCLUSION: These studies confirm the clinical potential of DP synthetic lung surfactant with B-YL peptide as a SP-B mimic to alleviate surfactant deficiency when delivered as a liquid bolus or as an aerosol.


Assuntos
Excipientes , Tensoativos , Aerossóis , Animais , Excipientes/farmacologia , Humanos , Pulmão , Pós/farmacologia , Coelhos , Ovinos , Suínos
6.
AAPS PharmSciTech ; 23(5): 114, 2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35441324

RESUMO

The objective of this study was to characterize the effects of multiple nasal prong interface configurations on nasal depositional loss of pharmaceutical aerosols in a preterm infant nose-throat (NT) airway model. Benchmark in vitro experiments were performed in which a spray-dried powder formulation was delivered to a new preterm NT model with a positive-pressure infant air-jet dry powder inhaler using single- and dual-prong interfaces. These results were used to develop and validate a computational fluid dynamics (CFD) model of aerosol transport and deposition in the NT geometry. The validated CFD model was then used to explore the NT depositional characteristic of multiple prong types and configurations. The CFD model highlighted a turbulent jet effect emanating from the prong(s). Analysis of NT aerosol deposition efficiency curves for a characteristic particle size and delivery flowrate (3 µm and 1.4 L/min (LPM)) revealed little difference in NT aerosol deposition fraction (DF) across the prong insertion depths of 2-5 mm (DF = 16-24%) with the exception of a single prong with 5-mm insertion (DF = 36%). Dual prongs provided a modest reduction in deposition vs. a single aerosol delivery prong at the same flow for insertion depths < 5 mm. The presence of the prongs increased nasal depositional loss by absolute differences in the range of 20-70% compared with existing correlations for ambient aerosols. In conclusion, the use of nasal prongs was shown to have a significant impact on infant NT aerosol depositional loss prompting the need for prong design alterations to improve lung delivery efficiency.


Assuntos
Inaladores de Pó Seco , Recém-Nascido Prematuro , Administração por Inalação , Aerossóis , Inaladores de Pó Seco/métodos , Desenho de Equipamento , Humanos , Lactente , Recém-Nascido , Sprays Nasais , Tamanho da Partícula , Pós
7.
Am J Perinatol ; 29(14): 1577-1585, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-33621983

RESUMO

OBJECTIVE: Successful extubation and prevention of reintubation remain primary goals in neonatal ventilation. Our aim was to compare three modalities of postextubation respiratory support-noninvasive positive pressure ventilation (NIPPV), nasal bilevel positive airway pressure (N-BiPAP), and nasal continuous positive airway pressure (NCPAP)-using the RAM cannula in preterm neonates with respiratory distress syndrome (RDS). Our secondary aim was to define the predictors of successful extubation. STUDY DESIGN: A total of 120 preterm neonates (gestational age ≤35 weeks) with RDS who had undergone primary invasive ventilation were randomized to receive either NIPPV, N-BiPAP, or NCPAP. The incidence of respiratory failure in the first 48 hours postextubation, total days of invasive and noninvasive ventilation, duration of hospitalization, and mortality were measured and compared among the three different noninvasive support modalities. RESULTS: There were no significant differences in the postextubation respiratory failure rates and the number of days of invasive as well as noninvasive ventilation among the three different support modalities (p > 0.05). The total number of days of mechanical ventilation and the duration of hospitalization were significantly higher in the N-BiPAP group than those in the NCPAP or NIPPV groups (p < 0.05). A gestational age of at least 29 weeks and a birth weight of at least 1.4 kg were predictive of successful extubation with a sensitivity of 98.2 and 85.3% and a specificity of 63.6 and 90.9%, respectively. CONCLUSION: Longer durations of mechanical ventilation and hospitalization were observed with N-BiPAP as a noninvasive mode of ventilation, but there was no significant difference in the extubation failure rates among the three modalities. Gestational age and birth weight were shown to be independent predictors of successful extubation of preterm neonates with RDS. KEY POINTS: · Successful extubation and reintubation prevention of preterms are primary goals in neonatal ventilation.. · NIPPV, N-BiPAP, and NCPAP could be used as postextubation noninvasive modes in preterm neonates.. · Gestational age and birth weight are independent predictors of successful extubation of preterms..


Assuntos
Ventilação não Invasiva , Síndrome do Desconforto Respiratório do Recém-Nascido , Insuficiência Respiratória , Extubação , Peso ao Nascer , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente , Respiração Artificial , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
8.
Pharmaceutics ; 13(10)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34683873

RESUMO

Surfactant administration incorporates liquid bolus instillation via endotracheal tube catheter and use of a mechanical ventilator. Aerosolized surfactant has generated interest and conflicting data related to dose requirements and efficacy. We hypothesized that aerosolized surfactant with a novel breath-actuated vibrating mesh nebulizer would have similar efficacy and safety as instilled surfactant. Juvenile rabbits (1.50 ± 0.20 kg, n = 17) were sedated, anesthetized, intubated, and surfactant was depleted via lung lavage on mechanical ventilation. Subjects were randomized to receive standard dose liquid instillation via catheter (n = 5); low dose surfactant (n = 5) and standard dose surfactant (n = 5) via aerosol; and descriptive controls (no treatment, n = 2). Peridosing events, disease severity and gas exchange, were recorded every 30 min for 3 h following surfactant administration. Direct-Instillation group had higher incidence for peridosing events than aerosol. Standard dose liquid and aerosol groups had greater PaO2 from pre-treatment baseline following surfactant (p < 0.05) with greater ventilation efficiency with aerosol (p < 0.05). Our study showed similar improvement in oxygenation response with greater ventilation efficiency with aerosol than liquid bolus administration at the same dose with fewer peridosing events. Breath-synchronized aerosol via nebulizer has potential as a safe, effective, and economical alternative to bolus liquid surfactant instillation.

9.
Respir Care ; 66(10): 1572-1581, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33824173

RESUMO

BACKGROUND: Despite its established safety, efficacy, and relative simplicity, CPAP treatment is not widely available for newborns and infants in low- and middle-income settings. A novel bubble CPAP system was designed to address the gaps in quality and accessibility of existing CPAP systems by providing blended, humidified, and pressurized gases without the need for electricity, compressed air, or manual power. This was the first study that tested the performance of the system with a simulated patient model. METHODS: In a spontaneously breathing 3-dimensional printed nasal airway model of a preterm neonate, CPAP performance was assessed based on delivered pressure, oxygen level, and humidity at different settings. RESULTS: Preliminary device performance characteristics were within 5% among 3 separate devices. Performance testing showed accurate control of CPAP and oxygen concentration at all settings with the bubble CPAP system. Lung model pressure and oxygen concentration were shown to stay within ±0.5 cm H2O and ±4% of full scale of the device settings, respectively, with relative humidity > 80%. CONCLUSIONS: Performance testing of the bubble CPAP system demonstrated accurate control of CPAP and oxygen concentration with humidity levels suitable for premature newborns on noninvasive support.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Lactente , Recém-Nascido , Oxigênio , Respiração , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
10.
Crit Care Explor ; 3(2): e0338, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33604579

RESUMO

OBJECTIVES: Effective treatment options for surfactant therapy in acute respiratory distress syndrome and coronavirus disease 2019 have not been established. To conduct preclinical studies in vitro and in vivo to evaluate efficiency, particle size, dosing, safety, and efficacy of inhaled surfactant using a breath-synchronized, nebulized delivery system in an established acute respiratory distress syndrome model. DESIGN: Preclinical study. SETTING: Research laboratory. SUBJECTS: Anesthetized pigs. INTERVENTION: In vitro analysis included particle size distribution and inhaled dose during simulated ventilation using a novel breath-synchronized nebulizer. Physiologic effects of inhaled aerosolized surfactant (treatment) were compared with aerosolized normal saline (control) in an adult porcine model (weight of 34.3 ± 0.6 kg) of severe acute respiratory distress syndrome (Pao2/Fio2 <100) with lung lavages and ventilator-induced lung injury during invasive ventilation. MEASUREMENTS AND MAIN RESULTS: Mass median aerosol diameter was 2.8 µm. In vitro dose delivered distal to the endotracheal tube during mechanical ventilation was 85% ± 5%. Nebulizers were functional up to 20 doses of 108 mg of surfactant. Surfactant-treated animals (n = 4) exhibited rapid improvement in oxygenation with nearly full recovery of Pao2/Fio2 (~300) and end-expiratory lung volumes with nominal dose less than 30 mg/kg of surfactant, whereas control subjects (n = 3) maintained Pao2/Fio2 less than 100 over 4.5 hours with reduced end-expiratory lung volume. There was notably greater surfactant phospholipid content and lower indicators of lung inflammation and pathologic lung injury in surfactant-treated pigs than controls. There were no peridosing complications associated with nebulized surfactant, but surfactant-treated animals had progressively higher airway resistance post treatment than controls with no differences in ventilation effects between the two groups. CONCLUSIONS: Breath-synchronized, nebulized bovine surfactant appears to be a safe and feasible treatment option for use in coronavirus disease 2019 and other severe forms of acute respiratory distress syndrome.

11.
Respir Res ; 22(1): 20, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33461535

RESUMO

BACKGROUND: COVID-19 causes acute respiratory distress syndrome (ARDS) and depletes the lungs of surfactant, leading to prolonged mechanical ventilation and death. The feasibility and safety of surfactant delivery in COVID-19 ARDS patients have not been established. METHODS: We performed retrospective analyses of data from patients receiving off-label use of exogenous natural surfactant during the COVID-19 pandemic. Seven COVID-19 PCR positive ARDS patients received liquid Curosurf (720 mg) in 150 ml normal saline, divided into five 30 ml aliquots) and delivered via a bronchoscope into second-generation bronchi. Patients were matched with 14 comparable subjects receiving supportive care for ARDS during the same time period. Feasibility and safety were examined as well as the duration of mechanical ventilation and mortality. RESULTS: Patients showed no evidence of acute decompensation following surfactant installation into minor bronchi. Cox regression showed a reduction of 28-days mortality within the surfactant group, though not significant. The surfactant did not increase the duration of ventilation, and health care providers did not convert to COVID-19 positive. CONCLUSIONS: Surfactant delivery through bronchoscopy at a dose of 720 mg in 150 ml normal saline is feasible and safe for COVID-19 ARDS patients and health care providers during the pandemic. Surfactant administration did not cause acute decompensation, may reduce mortality and mechanical ventilation duration in COVID-19 ARDS patients. This study supports the future performance of randomized clinical trials evaluating the efficacy of meticulous sub-bronchial lavage with surfactant as treatment for patients with COVID-19 ARDS.


Assuntos
Produtos Biológicos/administração & dosagem , Tratamento Farmacológico da COVID-19 , Pulmão/efeitos dos fármacos , Fosfolipídeos/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Idoso , Produtos Biológicos/efeitos adversos , Broncoscopia , COVID-19/diagnóstico , COVID-19/mortalidade , COVID-19/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fosfolipídeos/efeitos adversos , Projetos Piloto , Surfactantes Pulmonares/efeitos adversos , Respiração Artificial , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
Respir Care ; 65(7): 984-993, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32071129

RESUMO

BACKGROUND: There is limited evidence supporting an optimum method for removing mucus from the airways of hospitalized infants with bronchiolitis. This study was designed to evaluate short-term physiologic effects between nasal aspiration and nasopharyngeal suctioning in infants. METHODS: Sixteen infants requiring hospitalization for supportive management of bronchiolitis were instrumented with transcutaneously measured partial pressure of carbon dioxide ([Formula: see text]) and [Formula: see text] monitoring. Electrical impedance tomography (EIT) was used to estimate changes in inspiratory and end-expiratory lung volume loss and recovery. Subjects were suctioned with both nasal aspiration and nasopharyngeal suctioning methods in a randomized order (8 received nasal aspiration followed by nasopharyngeal suctioning, and 8 received nasophayrgeal suctioning followed by nasal aspiration). Noninvasive gas exchange and EIT measurements were obtained at baseline (pre-suction) and at 10, 20, and 30 min following each suctioning intervention. Sputum mass was obtained following suctioning, and clinical respiratory severity scores, before and after suctioning, were computed. RESULTS: There were no differences in inspiratory EIT (P = .93), change in end-expiratory lung impedance (ΔEELI; P = .53), [Formula: see text] (P = .41), [Formula: see text] (P = .88), heart rate (P = .31), or breathing frequency (P = .15) over the course of suctioning between nasal aspiration and nasopharyngeal suctioning. Sputum mass (P = .14) and clinical respiratory score differences before and after suctioning (P = .59) were not different between the 2 suctioning interventions. Sputum mass was not associated with ΔEELI at 30 min for nasal aspiration (ρ = 0.11, P = .69), but there was a moderate positive association for nasopharyngeal suctioning (ρ = 0.50, P = .048). CONCLUSIONS: Infants with viral bronchiolitis appeared to tolerate both suctioning techniques without adverse short-term physiologic effects, as indicated by the unchanged gas exchange and estimated lung volumes (EIT). Nasopharyngeal suctioning recovered 36% more sputum than did nasal aspiration and there was moderate correlation between sputum mass and end-expiratory lung impedance change at 30 minutes post-suction with nasopharyngeal that was not present with nasal aspiration. It is possible that a subset of patients may benefit from one type of suctioning over another. Future research focusing on important outcomes for suctioning patients with bronchiolitis with varying degrees of lung disease severity is needed.


Assuntos
Bronquiolite Viral , Bronquiolite , Bronquiolite/terapia , Bronquiolite Viral/terapia , Impedância Elétrica , Humanos , Lactente , Medidas de Volume Pulmonar , Sucção/efeitos adversos
13.
Respir Care ; 65(3): 333-340, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31992672

RESUMO

BACKGROUND: There is evidence that ventilator weaning protocols provide benefit to children receiving mechanical ventilation, but many protocols do not include explicit instructions for decreasing ventilator support from maximal settings. We evaluated care provider opinions on ventilator weaning recommendations made by a computerized decision support tool. METHODS: Recommendations for ventilator adjustment were generated using a computerized decision support tool based on the ARDSNet protocol using data from children with acute hypoxemic respiratory failure admitted to the pediatric ICU (PICU). Attending physicians, fellows, nurse practitioners, and respiratory therapists (RTs) caring for these patients answered a brief survey to assess whether recommendations were reasonable and whether the practitioner believed they could be implemented. RESULTS: RTs completed 99 surveys and ICU providers completed 96 surveys based on data from 10 patients. RTs and ICU providers found 63.9% and 65.3% of recommendations reasonable, respectively. There were 5 instances of disagreement between RTs and ICU providers. The percent of recommendations that RTs thought could be implemented was 29.9%, whereas this figure for ICU providers was 26.3%, with 4 instances of disagreement. Free-text responses indicated that many RTs and ICU providers were concerned about disrupting current patient stability and low tidal volumes. CONCLUSIONS: On initial evaluation, the decision support tool did not appear to be highly acceptable to RTs and ICU providers in our setting because recommendations were rarely implemented. In addition, acceptability did not increase over time as patients generally improved. Most respondents preferred to make no ventilator changes and felt the recommendations were too aggressive. The notable barrier to use was a perception of potential patient instability with weaning.


Assuntos
Cuidados Críticos/métodos , Sistemas de Apoio a Decisões Clínicas , Pessoal de Saúde , Desmame do Respirador/métodos , Adolescente , Criança , Protocolos Clínicos , Estudos de Coortes , Feminino , Humanos , Unidades de Terapia Intensiva Pediátrica , Masculino , Estudos Prospectivos , Respiração Artificial , Insuficiência Respiratória/terapia , Inquéritos e Questionários , Volume de Ventilação Pulmonar , Ventiladores Mecânicos
14.
J Perinatol ; 40(2): 330-336, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31844185

RESUMO

OBJECTIVE: Our aim was to decrease radiograph use for monitoring placement of peripherally inserted central catheters (PICC) and endotracheal tubes (ETT) in neonates admitted to the neonatal intensive care unit (NICU) by 20% from November 2017 to November 2018. STUDY DESIGN: We carried out three Plan-Do-Study-Act (PDSA) cycles: (1) implementation of a radiograph protocol emphasizing ideal patient positioning, standard radiograph views and frequency, (2) standardizing ETT depth using the NRP guidelines, and (3) implementation of an institution specific ETT depth guideline. RESULTS: The pre-intervention radiographs per PICC day was 0.86 versus a post-intervention value of 0.46 (P = 0.004). The pre-intervention radiographs per ETT day was 1.45 versus a post-intervention value of 1.07 (P = 0.002). CONCLUSIONS: Our multidisciplinary NICU team performed a QI project, which resulted in more than a 20% decrease in the number of radiographs used for monitoring placement of PICCs and ETTs.


Assuntos
Cateterismo Periférico , Intubação Intratraqueal , Melhoria de Qualidade , Radiografia/estatística & dados numéricos , Cateterismo Venoso Central , Cateterismo Periférico/métodos , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal/métodos , Uso Excessivo dos Serviços de Saúde/prevenção & controle , Guias de Prática Clínica como Assunto , Radiografia/normas
15.
Respir Care ; 64(4): 361-371, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30723169

RESUMO

BACKGROUND: Different brands of volume-targeted modes may vary the location of tidal volume (VT) monitoring and whether peak inspiratory pressure is adjusted based on inspiratory, expiratory, or leak-compensated VT. These variables may result in different levels of support provided to patients, especially when an endotracheal tube (ETT) leak is present. We hypothesized that there would be no differences in gas exchange, triggering, or work of breathing between volume-targeted modes of 3 different brands of equipment in a surfactant-deficient, spontaneously breathing animal model with and without an ETT leak. METHODS: Twelve rabbits (mean ± SD 1.61 ± 0.20 kg) were sedated, anesthetized, intubated, lavaged with 0.9% saline solution, and randomized in a crossover design so that each animal was supported by 3 different volume-targeted modes at identical settings with and without an ETT leak. After 30 min, arterial blood gas, VT, and esophageal and airway pressure were recorded for each condition, and pressure-rate product and percentage of successfully triggered breaths were calculated. RESULTS: Gas exchange and the pressure-rate product were not different between the ventilators in the absence of an ETT leak. When an ETT leak was introduced, volume-guarantee modes allowed a higher percentage of triggered breaths and peak inspiratory pressure, which resulted in higher minute ventilation, pH, and lower PaCO2 than the pressure-regulated volume control mode (P < .05). CONCLUSIONS: When a moderate ETT leak was present, volume-targeted modes that used proximal VT monitoring and triggering with adaptive leak compensation capabilities appeared more effective in providing ventilation support than did a ventilator that used measurements obtained from the back at the ventilator and does not have leak compensation.


Assuntos
Intubação Intratraqueal , Troca Gasosa Pulmonar/fisiologia , Respiração Artificial , Volume de Ventilação Pulmonar , Ventiladores Mecânicos , Animais , Animais Recém-Nascidos/fisiologia , Gasometria/métodos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Teste de Materiais , Modelos Animais , Monitorização Fisiológica/métodos , Surfactantes Pulmonares/metabolismo , Coelhos , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Testes de Função Respiratória/métodos , Mecânica Respiratória/fisiologia , Ventiladores Mecânicos/classificação , Ventiladores Mecânicos/normas
18.
Can J Respir Ther ; 54(1)2018.
Artigo em Inglês | MEDLINE | ID: mdl-29636639

RESUMO

INTRODUCTION: This study was designed to evaluate short-term physiologic outcomes of transitioning neonates with bronchopulmonary dysplasia (BPD) from intensive care unit (ICU) ventilators to both the Trilogy 202 (Philips Healthcare, Andover, MA) and LTV 1200 (CareFusion, Yorba Linda, CA) subacute ventilators. METHODS: Six infants with BPD requiring tracheostomies for support with a neonatal-specific ICU ventilator underwent placement of esophageal balloon catheters, airway pressure transducers, flow sensors, oxygen saturation (SpO2), and end tidal carbon dioxide (PETCO2) monitors. Noninvasive gas exchange, airflow, and airway and esophageal pressures (PES) were recorded following 20 min on the ICU ventilator. The infants were placed on the Trilogy 202 and LTV 1200 ventilators in random order at identical settings as the ICU ventilator. We measured noninvasive gas exchange, pressure-rate product (respiratory rate × ΔPES), ventilator response times, and the percentage of spontaneous breaths that triggered the ventilator at 20 min in each subject while being supported with each of the different subacute ventilators. RESULTS: The mean (SD) weight of the six infants was 4.983 (0.56) kg. There were no differences in heart rate (p = 0.51) or SpO2 (p = 0.97) but lower PETCO2, ΔPES, respiratory rate, pressure rate-product, response times, and greater percentage of subject initiated breaths that triggered the ventilator (p < 0.05) was observed with the Trilogy 202 than the LTV 1200. All six infants transitioned successfully from the ICU ventilator to the Trilogy 202 ventilator. CONCLUSION: In this small group of infants with BPD, the Trilogy 202 ventilator performed better than the LTV 1200. The improved subject efforts, per cent subject triggering, and response times observed with the Trilogy are likely related to differences in triggering algorithms, location of triggering mechanisms, and gas delivery system performance within the ventilators. These pilot data may be useful for informing future clinical study design and understanding differences in the level of support provided by different subacute ventilators in infants with BPD.

19.
J Perianesth Nurs ; 33(6): 964-971, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29402527

RESUMO

PURPOSE: To examine the practice of nebulizer cool mist blow-by oxygen administered to spontaneously breathing postanesthesia care unit (PACU) pediatric patients during Phase one recovery. DESIGN: Existing evidence was evaluated. Informal benchmarking documented practices in peer organizations. An in vitro study was then conducted to simulate clinical practice and determine depth and amount of airway humidity delivery with blow-by oxygen. METHODS: Informal benchmarking information was obtained by telephone interview. Using a three-dimensional printed simulation model of the head connected to a breathing lung simulator, depth and amount of moisture delivery in the respiratory tree were measured. FINDINGS: Evidence specific to PACU administration of cool mist blow-by oxygen was limited. Informal benchmarking revealed that routine cool mist oxygenated blow-by administration was not widely practiced. The laboratory experiment revealed minimal moisture reaching the mid-tracheal area of the simulated airway model. CONCLUSIONS: Routine use of oxygenated cool mist in spontaneously breathing pediatric PACU patients is not supported.


Assuntos
Umidade , Oxigênio/administração & dosagem , Cuidados Pós-Operatórios/métodos , Respiração , Benchmarking , Criança , Pré-Escolar , Humanos , Modelos Anatômicos , Nebulizadores e Vaporizadores , Impressão Tridimensional , Sala de Recuperação
20.
Curr Probl Diagn Radiol ; 47(1): 14-18, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28552547

RESUMO

BACKGROUND: Image quality of high resolution chest computed tomographies (HRCTs) depends on adequate breath holds at end inspiration and end expiration. We hypothesized that implementation of spirometry-assisted breath holds in children undergoing HRCTs would improve image quality over that obtained with voluntary breath holds by decreasing motion artifact and atelectasis. METHODS: This is a retrospective case-control study of HRCTs obtained at a tertiary care children's hospital before and after implementation of a spirometry-assisted CT protocol, in which children ≥8 years of age are first trained in supine slow vital capacity maneuvers and then repeat the maneuvers in the CT scanner, coached by a respiratory therapist. Spirometry-assisted CT scans (cases) were matched by age, gender and diagnosis (cystic fibrosis vs other) to CT scans obtained with voluntary breath holds in the 6 years before implementation of the spirometry assistance protocol (controls), and evaluated by 2 blinded pediatric radiologists. RESULTS: Among both cases and controls (N = 50 each), 10 carried the diagnosis of cystic fibrosis and 40 had other diagnoses. Mean age was 12.9 years (range: 7.5-20.1) among cases and 13.0 (7.1-19.7) among controls. Mean (SD) inspiratory image density among cases was -852 (37) Hounsfield units (HU) and -828 (43) among controls (p = 0.006). Mean (SD) expiratory image density was -629 (95) HU among cases and -688 (83) HU among controls (p = 0.002). Mean (SD) change in image density between inspiratory and expiratory images was +222 (85) HU among cases and +140 (76) HU among controls (p < 0.001). Motion artifact was present on inspiratory images in 5 cases and 9 controls (p = 0.39 by Fisher's exact test), and on expiratory images in 20 cases and 18 controls (p > 0.80). Atelectasis was present on inspiratory images in 8 cases and 9 controls and on expiratory images in 9 cases and 10 controls (p > 0.80). CONCLUSIONS: Spirometry-assisted CTs had a significantly greater difference in lung density between inspiratory and expiratory scans than those performed with voluntary breath holds, likely improving the ability to detect air trapping. No appreciable difference in image quality was detected for the presence of motion artifact or atelectasis.


Assuntos
Radiografia Torácica/métodos , Doenças Respiratórias/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória/métodos , Espirometria , Tomografia Computadorizada por Raios X/métodos , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos , Washington