Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Clin Chem ; 47(7): 1166-82, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11427446

RESUMO

BACKGROUND: Deaths from inherited metabolic disorders may remain undiagnosed after postmortem examination and may be classified as sudden infant death syndrome. Tandem mass spectrometry (MS/MS) may reveal disorders of fatty acid oxidation in deaths of previously unknown cause. METHODS: We obtained filter-paper blood from 7058 infants from United States and Canadian Medical Examiners. Acylcarnitine and amino acid profiles were obtained by MS/MS. Specialized interpretation was used to evaluate profiles for disorders of fatty acid, organic acid, and amino acid metabolism. The analyses of postmortem blood specimens were compared with the analyses of bile specimens, newborn blood specimens, and specimens obtained from older infants at risk for metabolic disorders. RESULTS: Results on 66 specimens suggested diagnoses of metabolic disorders. The most frequently detected disorders were medium-chain and very-long-chain acyl-CoA dehydrogenase deficiencies (23 and 9 cases, respectively), glutaric acidemia type I and II deficiencies (3 and 8 cases, respectively), carnitine palmitoyl transferase type II/translocase deficiencies (6 cases), severe carnitine deficiency (4 cases), isovaleric acidemia/2-methylbutyryl-CoA dehydrogenase deficiencies (4 cases), and long-chain hydroxyacyl-CoA dehydrogenase/trifunctional protein deficiencies (4 cases). CONCLUSIONS: Postmortem metabolic screening can explain deaths in infants and children and provide estimates of the number of infant deaths attributable to inborn errors of metabolism. MS/MS is cost-effective for analysis of postmortem specimens and should be considered for routine use by Medical Examiners and pathologists in unexpected/unknown infant and child death.


Assuntos
Carnitina/análogos & derivados , Carnitina/sangue , Erros Inatos do Metabolismo/diagnóstico , Morte Súbita do Lactente/diagnóstico , Autopsia , Bile/química , Coleta de Amostras Sanguíneas , Canadá , Carnitina/análise , Ácidos Graxos/metabolismo , Humanos , Lactente , Recém-Nascido , Erros Inatos do Metabolismo/metabolismo , Oxirredução , Papel , Valores de Referência , Espectrometria de Massas por Ionização por Electrospray , Estados Unidos
4.
Acta Paediatr Suppl ; 88(432): 45-7, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10626577

RESUMO

Clinical and neonatal screening methods using a tandem mass spectrometer are clearly a model for modern laboratory testing in the new Millennium. By the year 2000, more than 1 million blood and plasma samples will have been tested in laboratories throughout the world for a battery of metabolic disorders using a tandem mass spectrometer as the primary analytical device. A tandem mass spectrometer is considered the "ultimate" analytical detector in a variety of biochemical and clinical methods because of its very high accuracy, selectivity, precision, versatility and robust nature. The ability to achieve very high and reproducible sample throughput (approximately 600 samples/instrument/24 h) has made this technology cost-effective for newborn screening. In order to reliably measure markers of inborn errors of metabolism while maintaining low costs and high efficiency, accuracy and quality, much attention needs to be placed on monitoring and maintenance of all components of the entire testing system. These components include specimen collection and sample preparation methods, analysis by LC tandem mass spectrometry, conversion of raw mass spectra (data) into clinically meaningful results (concentration), expert interpretation of these results so that the clinician can be provided with information to facilitate a diagnose, and follow-up and education so that the maximum benefits of newborn screening translate into prevention of disease symptoms or more effective treatments. Addressing each part of the whole system will produce a quality screening program that will detect a battery of disorders using tandem mass spectrometry with a disease frequency of nearly 1 in 4000 infants.


Assuntos
Espectrometria de Massas/tendências , Erros Inatos do Metabolismo/diagnóstico , Triagem Neonatal/métodos , Técnicas de Laboratório Clínico/instrumentação , Feminino , Previsões , Humanos , Recém-Nascido , Masculino , Espectrometria de Massas/estatística & dados numéricos , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...