Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Methods Programs Biomed ; 219: 106771, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35390724

RESUMO

BACKGROUND: Consumer-level cameras have provided an advantage of designing cost-effective, non-contact physiological parameters estimation approaches which is not possible with gold standard estimation techniques. This encourages the development of non-contact estimation methods using camera technology. Therefore, this work aims to present a systematic review summarizing the currently existing face-based non-contact methods along with their performance. METHODS: This review includes all heart rate (HR) and oxygen saturation (SpO2) studies published in journals and a few reputed conferences, which have compared the proposed estimation methods with one or more standard reference devices. The articles were collected from the following research databases: Institute of Electrical and Electronics Engineers (IEEE), PubMed, Web of Science (WoS), Science Direct, and Association of Computer Machinery (ACM) digital library. All database searches were completed on May 20, 2021. Each study was assessed using a finite set of identified factors for reporting bias. RESULTS: Out of 332 identified studies, 32 studies were selected for the final review. Additionally, 18 studies were included by thoroughly checking these studies. 3 out of 50 (6%) studies were performed in clinical conditions, while the remaining studies were carried out on a healthy population. 42 out of 50 (84%) studies have estimated HR, while 5/50 (10%) studies have measured SpO2 only. The remaining three studies have estimated both parameters. The majority of the studies have used 1-3 min videos for estimation. Among the estimation methods, Deep Learning and Independent component analysis (ICA) were used by 11/42 (26.19%) and 9/42 (21.42%) studies, respectively. According to the Bland-Altman analysis, only 8/45 (17.77%) HR studies achieved the clinically accepted error limits whereas, for SpO2, 4/5 (80%) studies have matched the industry standards (±3%). DISCUSSION: Deep Learning and ICA have been predominantly used for HR estimations. Among deep learning estimation methods, convolutional neural networks have been employed till date due to their good generalization ability. Most non-contact HR estimation methods need significant improvements to implement these methods in a clinical environment. Furthermore, these methods need to be tested on the subjects suffering from any related disease. SpO2 estimation studies are challenging and need to be tested by conducting hypoxemic events. The authors would encourage reporting the detailed information about the study population, the use of longer videos, and appropriate performance metrics and testing under abnormal HR and SpO2 ranges for future estimation studies.


Assuntos
Face , Saturação de Oxigênio , Frequência Cardíaca/fisiologia , Humanos
2.
IEEE J Biomed Health Inform ; 26(10): 4837-4848, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35077371

RESUMO

Heart Rate (HR) estimation is of utmost importance due to its applicability in diverse fields. Conventional methods for HR estimation require skin contact and are not suitable in certain scenarios such as sensitive skin or prolonged unobtrusive HR monitoring. Therefore remote photoplethysmography (rPPG) methods have become an active area of research. These methods utilize the facial videos acquired using a camera followed by extracting the Blood Volume Pulse (BVP) signal for heart rate calculation. The existing rPPG methods either utilized a single color channel or weighted color differences, which has certain limitations dealing with motion and illumination artifacts. This study considered BVP extraction as an undercomplete problem and proposed a method resistant to motion and illumination variation artifacts. This method is based on an undercomplete independent component analysis, aiming to estimate the unmixing matrix using a non-linear Cumulative Density Function (CDF) that has been optimized using the customized Levenberg-Marquardt algorithm. Therefore, the method is named U-LMA. The proposed method was tested under three scenarios: constrained, motion, and illumination variations scenarios. High Pearson correlation coefficient values and smaller lower-upper statistical limits of Bland-Altman plots justified the outstanding performance of the proposed U-LMA. Furthermore, its comparative analysis with the state-of-the-art methods demonstrated its efficacy and reliability, which was proven by the lowest error and highest correlation values (0.01 significance level). Additionally, higher accuracy satisfying the clinically accepted error differences also justified its clinical relevance.


Assuntos
Iluminação , Processamento de Sinais Assistido por Computador , Algoritmos , Frequência Cardíaca/fisiologia , Humanos , Movimento (Física) , Fotopletismografia/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...