Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39227027

RESUMO

OBJECTIVE: To describe a modification of the tibial plateau leveling osteotomy technique wherein a double cut is made in the same plane to level the tibial plateau (double-cut tibial plateau leveling osteotomy [DCTPLO]) for treating dogs with cranial cruciate ligament (CrCL) and excessive tibial plateau angle (eTPA) diseases. STUDY DESIGN: The DCTPLO technique was performed on 18 stifles in dogs with CrCL and an eTPA (>34°). This study evaluated the accuracy of preoperative planning, feasibility of the technique, postoperative clinical outcomes, radiographic examinations at the postoperative follow-up for the first 120 days, evolution of the tibial plateau angle (TPA), time of union of the osteotomy, apposition of the implants, and possible complications. RESULTS: The described technique proved to be feasible for clinical application, with reproducibility from preoperative planning. An effective reduction in the eTPA levels was observed. The mean preoperative and postoperative TPA values were 39.4° (36°-43.5°) and 6.3° (3°-13°), respectively. Radiographic healing time was 60 days in 17/18 of stifles. Minor complications (not requiring surgical review or clinical treatment) were observed in 4/18 of stifles. CONCLUSION: The DCTPLO technique was effective for treating CrCL disease with TPA of up to 43.5° in dogs.

2.
Pesqui. vet. bras ; 38(10): 1909-1912, out. 2018. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-976373

RESUMO

Technological and tissue engineering have enabled available, biologically inert, and low cost materials to be considered as viable alternatives in the surgical treatment of long bone fractures in birds. The aim of this study was to microscopically analyse osteotomized humerus of birds following the insertion of solid laser-sintered polyamide 12 rods in order to detect foreign body reaction and, thus, verify the bioinert property of the material in the bone fracture environment. Polyamide 12 intramedullary rods were inserted into the osteotomized humerus of 10 birds (white Plymouth Rock) and blocked using 2mm diameter cortical screws of varying lengths. The birds were operated at 60 days of age and monitored post-operatively for three months. Animals were euthanized at 150 days old and samples of the operated humerus collected for immunohistochemistry, light and scanning electron microscopy analysis. Results show bone consolidation without rejection of the implant and absence of inflammatory cells. Vascular Endothelial Growth Factor (VEGF) was expressed in the endothelial cells of the blood vessels at the site of the newly formed bone surrounding the implant, indicative of local angiogenesis. There was no bone growth on the surface of the rod; however, the implant did not interfere with the circumjacent bone repair. Thus, the findings of this study corroborate with the literature in characterizing polyamide as a bioinert material and, under the studied conditions, it can be concluded that polyamide 12 intramedullary rod is biocompatible and provides adequate bone consolidation in humeral fractures with no signs of rejection.(AU)


Com o desenvolvimento tecnológico e crescimento da engenharia de tecidos, o uso de materiais disponíveis, bioinertes e debaixo custo pode ser alternativa viável para o tratamento cirúrgico de fraturas em ossos longos nas aves. O objetivo do estudo foi realizar avaliação microscópica óssea após a implantação de haste maciça de poliamida, implantada em úmeros osteotomizados de galinhas para detectar reação do tipo corpo estranho, verificando a propriedade "bioinerte" do material no ambiente de fratura óssea. Foram utilizados 10 galos (Plymouth rock branca) e implantou-se a haste perfazendo o bloqueio das mesmas com parafusos corticais de 2 mm de diâmetro com comprimentos de acordo com a necessidade. As aves foram operadas aos 60 dias de vida e o acompanhamento pós-operatório ocorreu por três meses. Após a eutanásia, foram realizadas coletas do úmero operado (local de consolidação óssea) paraexame histopatológico, imuno-histoquímico e de microscopia eletrônica de varredura. Os resultados demonstraram consolidação óssea, sem presença de rejeição do material, com ausência de células inflamatórias. A neoformação óssea ao redor do implante expressou VEGF (fator de crescimento endotelial vascular) nas células endoteliais dos vasos sanguíneos caracterizando angiogênese no local. Na região de interface de tecido ósseo com a poliamida não foram observadas micro fraturas. Não houve crescimento ósseo na superfície da haste, porém a mesma não atrapalhou o reparo ósseo circunjacente. Assim, esse estudo corrobora com a literatura caracterizando a poliamida como um material bioinerte, e nas condições estudadas pode-se concluir que o uso da haste intramedular de poliamida 12 proporcionou consolidação óssea nesse modelo biológico nesse tipo de fratura, não havendo indícios de induzir rejeição.(AU)


Assuntos
Animais , Materiais Biocompatíveis , Materiais Biocompatíveis/efeitos adversos , Galinhas , Fixação Interna de Fraturas/veterinária , Fixação Intramedular de Fraturas/veterinária , Reação Hospedeiro-Enxerto , Nylons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA