Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Braz J Biol ; 83: e275046, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37851774

RESUMO

Sugarcane is one of the largest agricultural commodities when considering the export volume and the number of jobs generated. Sugarcane production in the Brazilian Northeast region is generally low due to several factors, including the irregular rainfall distribution, which highlights the importance of studies aimed at mitigating the deleterious effects of water stress. In this scenario, this study aimed to evaluate calcium pyruvate as a water deficit attenuator on the agro-industrial quality of sugarcane in the second cycle of cultivation. The experiment was conducted out under greenhouse conditions of the Federal University of Campina Grande, where five sugarcane commercial genotypes tested (G1- RB863129, G2- RB92579, G3- RB962962, G4- RB021754, and G5- RB041443) and three irrigation management strategies (E1- full irrigation, E2- water deficit with application of 30 mM of calcium pyruvate, and E3- water deficit without calcium pyruvate application), distributed in randomized blocks in 5 × 3 factorial arrangement with three replications. The RB021754 genotype under water deficit and without foliar application of calcium pyruvate increased the fiber content (13.2%) and the sugarcane moist cake weight (143.5 g). The effects of water deficit in sugarcane genotypes are attenuated by the exogenous application of 30 mM of calcium pyruvate, with benefits on the polarized sucrose content, apparent sucrose content of the juice, soluble solids content, purity, corrected cane POL, total recoverable sugars, and stem mass in relation to plants under water deficit without calcium pyruvate application.


Assuntos
Saccharum , Saccharum/genética , Cálcio , Genótipo , Grão Comestível , Sacarose , Piruvatos
2.
Braz J Biol ; 83: e272003, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37162072

RESUMO

The lack of water during crop growth causes damage to any production system, especially when it occurs during the initial establishment or beginning of the reproductive stage. Although cotton can be properly managed in regions with water limitation, its yield is affected at different levels according to the genetics of the cultivar adopted. Exogenous application of some organic components has shown a stress-mitigating effect and can be a valuable procedure to enhance the yield of water stress-sensitive cultivars. The objective of this work was to evaluate the benefits of exogenous application of pyruvic acid (100 µM) in cotton plants under water deficit varying the phenological stage of the crop. The experiment was conducted in a greenhouse, where the plants were grown in pots and subjected to seven days of water suspension, initiated individually in stages V2 and B1. Each pot contained two plants. The treatments adopted were: T1 - control, T2 - water suppression; and T3 - water suppression + pyruvate application. The design was randomized blocks in a factorial scheme (3 × 3) with three replicates. The reductions in gas exchange and growth of the cultivars BRS Seridó, CNPA 7MH and FM 966 were more significant in the reproductive stage, especially for FM 966, which was more sensitive. Pyruvate application reduced the effects of water suppression on boll production by 31% in BRS Seridó and 34% in CNPA 7MH and FM 966.


Assuntos
Gossypium , Ácido Pirúvico , Ácido Pirúvico/farmacologia , Gossypium/genética , Reprodução
3.
Braz J Biol ; 83: e272615, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37222374

RESUMO

The limitation in the quality of water sources for irrigation in the semi-arid region of northeastern Brazil is increasingly present, so it is necessary to use water with high concentrations of salts for agricultural production, which makes the use of elicitors essential to mitigate the harmful effects of salinity on plants. Given the above, the objective of this study was to evaluate the effects of foliar application of salicylic acid on the mineral composition and production of guava plants under salt stress conditions in the post-grafting phase. The experiment was carried out under greenhouse conditions, in a randomized block design, in a 2 × 4 factorial scheme, with two levels of electrical conductivity of irrigation water (0.6 and 3.2 dS m-1) and four concentrations of salicylic acid (0, 1.2, 2.4, and 3.6 mM), with three replicates. During the flowering stage of guava, N, P, and K contents accumulated in the leaves according to the following order of concentration: N > K > P. Foliar application of 1.2 mM of salicylic acid increases the leaf contents of N, P, and K in guava plants grown under irrigation with water of 0.6 dS m-1. Water salinity of 3.2 dS m-1 reduces the growth and production components of guava plants.


Assuntos
Psidium , Ácido Salicílico , Estresse Salino , Minerais , Água
4.
Appl Radiat Isot ; 184: 110122, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35272231

RESUMO

This work consists of an experimental determination of k0 and Q0 for 121Sb, 123Sb and 130Ba targets. Covariance analysis has been introduced to supply not only the overall uncertainties in these parameters but also their correlations. The irradiations were performed near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Nuclear and Energy Research Institute (IPEN-CNEN/SP), in São Paulo, Brazil. The epithermal neutron flux shape parameter, alpha, at the irradiation position is very close to zero, which favors to obtain Q0 values more accurately. Two irradiations were carried out in sequence, using two sets of samples: the first with bare samples and the second inside a Cd cover. The activity measurements were carried out in a previously calibrated HPGe gamma-ray spectrometer. The measurements were corrected for: saturation, decay time, cascade summing, geometry, self-attenuation, measuring time and mass. Standard sources of 152Eu, 133Ba, 60Co and 137Cs traceable to a 4πß-γ primary system were used to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The experimental efficiency curve was performed by a fourth-degree polynomial fit, in the energy range of the standard sources, 121-1408 keV, it contains all correlations between points. For energies above 1408 keV, the efficiencies were obtained by the Monte Carlo Method. The covariance matrix methodology was applied to all uncertainties involved. The final values for k0 and Q0 were compared with the literature.


Assuntos
Método de Monte Carlo , Brasil
5.
Appl Radiat Isot ; 164: 109237, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32554127

RESUMO

The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN-CNEN/SP, in São Paulo, for the primary standardization of 166Ho is described. The activity of 166Ho was determined by the efficiency extrapolation technique applied to a 4πß(PC)-γ coincidence system using a gas flow proportional counter in 4π geometry coupled to a 76 × 76 mm NaI(Tl) crystal. The results for the γ-rays intensities at 80.57 and 1379.45 keV were 0.0651(11) and 0.00904(11), respectively.


Assuntos
Raios gama , Hólmio/normas , Radioisótopos/normas , Padrões de Referência , Espectrometria gama/normas
6.
Public Health Nutr ; 23(14): 2494-2500, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32456727

RESUMO

OBJECTIVE: We aimed to assess the validity of maternal recall of exclusive breastfeeding (EBF) at 3 months obtained 12 months after childbirth. DESIGN: A population-based birth cohort study. The gold standard is maternal report of EBF at the age of 3 months (yes or no) and age of introduction of other foods in the infant's diet. EBF was considered when the mother reported that no liquid, semi-solid or solid food was introduced up to that moment. The variable to be validated was obtained at 12 months after childbirth when the mother was asked about the age of food introduction. The prevalence of EBF at 3 months, and sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and accuracy of 12-month recall with 95 % CI were calculated. SETTING: Pelotas, Brazil. PARTICIPANTS: 3700 mothers of participants of the Pelotas 2004 Birth Cohort. RESULTS: The prevalence of EBF at 3 months was 27·8 % (95 % CI 26·4, 29·3) and 49·0 % (95 % CI 47·4, 50·6) according to gold standard and maternal recall, respectively. The sensitivity of maternal recall at 12 months was 98·3 % (95 % CI 97·4, 99·0), specificity 70·0 % (95 % CI 68·2, 71·7), PPV 55·8 % (95 % CI 53·4, 58·1), NPV 99·1 % (95 % CI 98·6, 99·5) and accuracy 77·9 % (95 % CI 76·6, 79·2). When the analyses were stratified by maternal and infant characteristics, the sensitivity remained around 98 %, and the specificity ranged from 64·4 to 81·8 %. CONCLUSIONS: EBF recalled at the end of the first year of infant's life is a valid measure to be used in epidemiological investigations.


Assuntos
Aleitamento Materno , Rememoração Mental , Mães , Brasil , Estudos de Coortes , Feminino , Humanos , Lactente , Gravidez
7.
Appl Radiat Isot ; 155: 108900, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31590099

RESUMO

The Nuclear Metrology Laboratory (LMN) - IPEN, São Paulo, Brazil - developed a Digital Coincidence System (DCS), based on the Coincidence Counting Methodology, in order to improve its capabilities in radionuclide primary-standardization. Digital process is implemented in two steps: data-acquisition (a set of measurements) and offline software data-analysis and calculation. The present work shows the basics of the data-acquisition unit (Software Coincidence System - SCS), describes the DCS' data-analysis process and the initial approaches chosen for the implementation of the software package (Coincidence Analyzing Task - CAT). 152Eu standardization, performed for DCS testing, software expansion and validation, is briefly discussed.

8.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31629294

RESUMO

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

9.
Appl Radiat Isot ; 154: 108846, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31442792

RESUMO

In the present work, the determinations of k0 and Q0 for 74Se, 113In, 186W and 191Ir targets were performed. The irradiations were conducted near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP - Nuclear and Energy Research Institute), in São Paulo, Brazil. The irradiation position was chosen where the neutron spectrum shape parameter α is very close to zero. For this reason, the correction to be applied for the determination of Q0 is very close to one, thus improving the accuracy of the results. For each experiment, two irradiations were carried out in sequence: the first one with bare samples and the second with a cadmium cover around the samples. All partial uncertainties were considered, applying the covariance matrix methodology. The final results were compared with the literature.

10.
Appl Radiat Isot ; 134: 205-211, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28939243

RESUMO

The main features of code SUMCOR developed for cascade summing correction for volumetric sources are described. MCNP6 is used to track histories starting from individual points inside the volumetric source, for each set of cascade transitions from the radionuclide. Total and FEP efficiencies are calculated for all gamma-rays and X-rays involved in the cascade. Cascade summing correction is based on the matrix formalism developed by Semkow et al. (1990). Results are presented applying the experimental data sent to the participants of two intercomparisons organized by the ICRM-GSWG and coordinated by Dr. Marie-Cristine Lépy from the Laboratoire National Henri Becquerel (LNE-LNHB), CEA, in 2008 and 2010, respectively and compared to the other participants in the intercomparisons.

11.
Appl Radiat Isot ; 134: 312-315, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28927836

RESUMO

The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN for the standardization of activity of 64Cu is described. The measurement was carried out in a 4π (PC) ß-γ coincidence system. The activity per unit mass of the solution was determined by the extrapolation technique. The events were registered using a Time to Amplitude Converter (TAC) associated with a Multi-channel Analyzer. The gamma-ray emission probability per decay of the 1345.7keV transition of 64Cu determined with a calibrated REGe gamma-ray spectrometer was (0.472 ± 0.010) %, in agreement with the literature.

12.
Appl Radiat Isot ; 109: 386-388, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26688361

RESUMO

The procedure for the standardization of (59)Fe using a 4π(PC)ß-γ software coincidence system is described. The standardization was performed with an experimental setup consisting of a thin window gas-flow proportional counter (PC) in 4π geometry coupled to a NaI(Tl) scintillator and to a HPGe detector. The data acquisition was carried out by means of a Software Coincidence System (SCS). The beta efficiency was changed by using Collodion films and aluminum foils as external absorbers.

13.
Appl Radiat Isot ; 89: 1-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24561648

RESUMO

The feasibility of Durolon as a thermal neutron dosimeter was studied. As experimentally determined the proposed methodology covers a wide range of doses, from 0.1 mSv

Assuntos
Nêutrons , Cimento de Policarboxilato/química , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Estudos de Viabilidade , Reprodutibilidade dos Testes
14.
Appl Radiat Isot ; 87: 126-31, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24290191

RESUMO

The procedure for determining the (67)Ga disintegration rate by a primary method is described. The proposed triple 4πß-γ coincidence system consists of a thin window gas-flow 4π proportional counter (PC) coupled to a NaI(Tl) scintillator and a HPGe crystal. Independent pulse height and occurrence time information is provided for the three detector outputs by means of a Software Coincidence System. Separate spectrometry measurements with a n-type reversed electrode coaxial Ge detector (REGe) were performed for obtaining gamma-ray emission probabilities per decay. Accurate values of disintegration rate, gamma-ray emission probabilities and the metastable half-life were achieved.

15.
Appl Radiat Isot ; 70(9): 2097-102, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425415

RESUMO

The procedure followed by the Nuclear Metrology Laboratory, at IPEN, for the primary standardization of (99m)Tc is described. The primary standardization has been accomplished by the coincidence method. The beta channel efficiency was varied by electronic discrimination using a software coincidence counting system. Two windows were selected for the gamma channel: one at 140 keV gamma-ray and the other at 20 keV X-ray total absorption peaks. The experimental extrapolation curves were compared with Monte Carlo simulations by means of code ESQUEMA.


Assuntos
Radiometria/métodos , Radiometria/normas , Software , Espectrometria gama/normas , Tecnécio/análise , Tecnécio/normas , Brasil , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
16.
Appl Radiat Isot ; 70(9): 2091-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425419

RESUMO

A series of (123)I measurements have been carried out in a 4π(e(A),X)-γ coincidence system. The experimental extrapolation curve was determined and compared to Monte Carlo simulation, performed by code ESQUEMA. From the slope of the experimental curve, the total conversion coefficient for the 159 keV total gamma transition, α(159), was determined. All radioactive sources were also measured in an HPGe spectrometry system, in order to determine the gamma-ray emission probability per decay for several gamma transitions. All uncertainties involved and their correlations were analyzed applying the covariance matrix methodology and the measured parameters were compared with those from the literature.


Assuntos
Radioisótopos do Iodo/análise , Modelos Químicos , Modelos Estatísticos , Radiometria/métodos , Simulação por Computador , Interpretação Estatística de Dados , Raios gama , Meia-Vida , Método de Monte Carlo , Doses de Radiação
17.
Appl Radiat Isot ; 70(9): 1825-30, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445396

RESUMO

An international Key Comparison of (177)Lu has recently been carried out. Twelve laboratories performed assays for radioactivity content on aliquots of a common master solution of (177)Lu, leading to eleven results submitted for entry into the Key Comparison Database of the Mutual Recognition Arrangement. A proposed Comparison Reference Value (CRV) was calculated to be 3.288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV.


Assuntos
Lutécio/análise , Lutécio/química , Radioisótopos/análise , Radioisótopos/química , Radiometria/instrumentação , Radiometria/normas , Lutécio/normas , Doses de Radiação , Radioisótopos/normas , Padrões de Referência , Valores de Referência
18.
Appl Radiat Isot ; 69(7): 960-4, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21478022

RESUMO

The values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn and (68)Zn(n,γ)(69m)Zn reactions were determined experimentally. The irradiations were performed near the core of the IEA-R1 3.5MW nuclear research reactor of the Nuclear and Energy Research Institute - IPEN-CNEN/SP, in São Paulo, Brazil. The results for the neutron field parameters f and α were 49.7(19) and -1.1(31)×10(-3), respectively. The resulting values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn reaction were 5.63(8)×10(-3) and 1.69(6), respectively, and the corresponding values for (68)Zn(n,γ)(69m)Zn reaction were 4.00(6)×10(-4) and 2.34(4), respectively. These results were compared with the literature.

19.
Appl Radiat Isot ; 68(7-8): 1566-70, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20060732

RESUMO

This work describes the measurements of the K X-ray and gamma-ray emission probabilities per decay of (198)Au performed at the Nuclear Metrology Laboratory (LMN) at the IPEN, São Paulo. The radioactive sample was obtained by means of (197)Au(n, gamma)(198)Au reaction irradiating an Au foil in a thermal neutron flux near the core of the IPEN 3.5 MW research reactor. The activity of samples was determined in a 4pibeta-gamma coincidence system, setting the gamma window at the 411.80 keV total energy absorption peak. The same samples were measured in two different spectrometers: a HPGe planar spectrometer with Be window, suitable for measurements in the low energy range and a coaxial REGe spectrometer. Both spectrometers were previously calibrated in a well defined geometry by means of standard sources calibrated in a 4pibeta-gamma coincidence system. MCNP4C Monte Carlo code was used for simulating the REGe spectrometer calibration curve, and a new version of code ESQUEMA was adopted for simulating the detection processes in the coincidence system, in order to predict the efficiency extrapolation curve.


Assuntos
Radioisótopos de Ouro , Raios gama , Probabilidade , Análise Espectral , Raios X
20.
Appl Radiat Isot ; 66(6-7): 764-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18359236

RESUMO

In an intercomparison exercise, the Monte Carlo codes most commonly used in gamma-ray spectrometry today were compared with each other in order to gauge the differences between them in terms of typical applications. No reference was made to experimental data; instead, the aim was to confront the codes with each other, as they were applied to the calculation of full-energy-peak and total efficiencies. Surprising differences between the results of different codes were revealed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...