Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888682

RESUMO

The effect of adding organized supramolecular systems such as ß-cyclodextrin (ß-CD) and hydroxypropyl-ß-cyclodextrin (HP-ß-CD) on the photochemically-induced fluorescence (PIF) spectral properties of tau-fluvalinate (TFV) in aqueous solutions was examined. The influence of pH, UV irradiation time and photoproduct stability on the cyclodextrin-enhanced photochemically-induced fluorescence intensity was also investigated. The spectral changes associated with the inclusion process yielded values for the formation constants of TFV inclusion complexes between 450 and 640 M-1, which were calculated using the nonlinear iterative regression approach least squares. In addition, host-guest interaction was clearly determined by PIF enhancement and a 1 : 1 stoichiometry was found for the ß-CD and HP-ß-CD complexes formed with TFV. The negative free energy (ΔG°) value indicated that the reaction of TFV with cyclodextrins was thermodynamically favorable. Furthermore, the structures of inclusion complexes of TFV with cyclodextrins were elucidated by 3-21G ab initio calculations. The limits of detection and quantification obtained ranged between 1.3 and 4.0 ng mL-1 and from 4.4 to 13.0 ng mL-1 in ß-CD and HP-ß-CD media, respectively. The analytical application in tap and river water samples yielded satisfactory mean recoveries ranging from 98.12 to 102.97%. Due to its sensitivity and ease of use, this method can be reliably applied to routine analysis.

2.
J Fluoresc ; 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37815658

RESUMO

In this work, analytical study of carbofuran (CAF) and fluometuron (FLM) pesticides was carried out using direct spectrofluorimetric method in various solvents. Results showed that CAF and FLM are naturally fluorescent in all solvents under study including organic (MeOH, MeCN, DMF) and aqueous micellar one (CTAC, SDS, Brij-700). For the analysis of FLM, CTAC give the best fluorescence signal enhancement. Analytical performances, such as limit of detection (LOD) and quantification (LOQ) was evaluated after solvent optimization and were found to vary, respectively, between 0.1 and 11 ng mL- 1 and between 0.3 and 36.6 ng mL- 1. Analytical application in various environmental aqueous samples matrices (sea, tap, runoff and well waters) give satisfactory recovery rates in the limits of 73.7-113.7% for both pesticides. This method is described for its simplicity for routine analysis.

3.
Spectrochim Acta A Mol Biomol Spectrosc ; 192: 117-121, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29127828

RESUMO

Permanent online monitoring of water supply pollution by hydrocarbons is needed for various industrial plants, to serve as an alert when thresholds are exceeded. Fluorescence spectroscopy is a suitable technique for this purpose due to its sensitivity and moderate cost. However, fluorescence measurements can be disturbed by the presence of suspended organic matter, which induces beam scattering and absorption, leading to an underestimation of hydrocarbon content. To overcome this problem, we propose an original technique of fluorescence spectra correction, based on a measure of the excitation beam scattering caused by suspended organic matter on the left side of the Rayleigh scattering spectral line. This correction allowed us to obtain a statistically validated estimate of the naphthalene content (used as representative of the polyaromatic hydrocarbon contamination), regardless of the amount of suspended organic matter in the sample. Moreover, it thus becomes possible, based on this correction, to estimate the amount of suspended organic matter. By this approach, the online warning system remains operational even when suspended organic matter is present in the water supply.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...