Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 12(1): 3171, 2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-34039975

RESUMO

Piezoelectric fluoropolymers convert mechanical energy to electricity and are ideal for sustainably providing power to electronic devices. To convert mechanical energy, a net polarization must be induced in the fluoropolymer, which is currently achieved via an energy-intensive electrical poling process. Eliminating this process will enable the low-energy production of efficient energy harvesters. Here, by combining molecular dynamics simulations, piezoresponse force microscopy, and electrodynamic measurements, we reveal a hitherto unseen polarization locking phenomena of poly(vinylidene fluoride-co-trifluoroethylene) (PVDF-TrFE) perpendicular to the basal plane of two-dimensional (2D) Ti3C2Tx MXene nanosheets. This polarization locking, driven by strong electrostatic interactions enabled exceptional energy harvesting performance, with a measured piezoelectric charge coefficient, d33, of -52.0 picocoulombs per newton, significantly higher than electrically poled PVDF-TrFE (approximately -38 picocoulombs per newton). This study provides a new fundamental and low-energy input mechanism of poling fluoropolymers, which enables new levels of performance in electromechanical technologies.

2.
J Chromatogr A ; 1436: 59-63, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26860051

RESUMO

Porting is a powerful methodology to recalibrate an existing database of ion chromatography (IC) retention times by reflecting the changes of column behavior resulting from either batch-to-batch variability in the production of the column or the manufacture of new versions of a column. This approach has been employed to update extensive databases of retention data of inorganic and organic anions forming part of the "Virtual Column" software marketed by Thermo Fisher Scientific, which is the only available commercial optimization tool for IC separation. The current porting process is accomplished by performing three isocratic separations with two representative analyte ions in order to derive a porting equation which expresses the relationship between old and new data. Although the accuracy of retention prediction is generally enhanced on new columns, errors were observed on some columns. In this work, the porting methodology was modified in order to address this issue, where the porting equation is now derived by using six representative analyte ions (chloride, bromide, iodide, perchlorate, sulfate, and thiosulfate). Additionally, the updated porting methodology has been applied on three Thermo Fisher Scientific columns (AS20, AS19, and AS11HC). The proposed approach showed that the new porting methodology can provide more accurate and robust retention prediction on a wide range of columns, where average errors in retention times for ten test anions under three eluent conditions were less than 1.5%. Moreover, the retention prediction using this new approach provided an acceptable level of accuracy on a used column exhibiting changes in ion-exchange capacity.


Assuntos
Cromatografia por Troca Iônica/métodos , Bases de Dados Factuais , Ânions , Brometos/análise , Cloretos/análise , Cromatografia por Troca Iônica/instrumentação , Iodetos/análise , Troca Iônica , Percloratos/análise
3.
Talanta ; 143: 191-197, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26078148

RESUMO

The applicability of acid degradation of organic peroxides into hydrogen peroxide in a pneumatically driven flow injection system with chemiluminescence reaction with luminol and Cu(2+) as a catalyst (FIA-CL) was investigated for the fast and sensitive detection of organic peroxide explosives (OPEs). The target OPEs included hexamethylene triperoxide diamine (HMTD), triacetone triperoxide (TATP) and methylethyl ketone peroxide (MEKP). Under optimised conditions maximum degradations of 70% and 54% for TATP and HMTD, respectively were achieved at 162 µL min(-1), and 9% degradation for MEKP at 180 µL min(-1). Flow rates were precisely controlled in this single source pneumatic pressure driven multi-channel FIA system by model experiments on mixing of easily detectable component solutions. The linear range for detection of TATP, HMTD and H2O2 was 1-200 µM (r(2)=0.98-0.99) at both flow rates, while that for MEKP was 20-200 µM (r(2)=0.97) at 180 µL min(-1). The detection limits (LODs) obtained were 0.5 µM for TATP, HMTD and H2O2 and 10 µM for MEKP. The detection times varied from 1.5 to 3 min in this FIA-CL system. Whilst the LOD for H2O2 was comparable with those reported by other investigators, the LODs and analysis times for TATP and HMTD were superior, and significantly, this is the first time the detection of MEKP has been reported by FIA-CL.


Assuntos
Substâncias Explosivas/análise , Peróxido de Hidrogênio/química , Medições Luminescentes/métodos , Peróxidos/análise , Substâncias Explosivas/química , Análise de Injeção de Fluxo , Produtos Domésticos , Ácido Clorídrico/química , Hidrólise , Cinética , Limite de Detecção , Luminol/química , Metais/química , Peróxidos/química , Ácidos Sulfúricos/química
4.
Anal Chim Acta ; 876: 91-7, 2015 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-25998463

RESUMO

CE methods have been developed for the analysis of organic and peroxide-based explosives. These methods have been developed for deployment on portable, in-field instrumentation for rapid screening. Both classes of compounds are neutral and were separated using micellar electrokinetic chromatography (MEKC). The effects of sample composition, separation temperature, and background electrolyte composition were investigated. The optimised separation conditions (25 mM sodium tetraborate, 75 mM sodium dodecyl sulfate at 25°C, detection at 200 nm) were applied to the separation of 25 organic explosives in 17 min, with very high efficiency (typically greater than 300,000 plates m(-1)) and high sensitivity (LOD typically less than 0.5 mg L(-1); around 1-1.5 µM). A MEKC method was also developed for peroxide-based explosives (10 mM sodium tetraborate, 100 mM sodium dodecyl sulfate at 25°C, detection at 200 nm). UV detection provided LODs between 5.5 and 45.0 mg L(-1) (or 31.2-304 µM), which is comparable to results achieved using liquid chromatography. Importantly, no sample pre-treatment or post-column reaction was necessary and the peroxide-based explosives were not decomposed to hydrogen peroxide. Both MEKC methods have been applied to pre-blast analysis and for the detection of post-blast residues recovered from controlled, small scale detonations of organic and peroxide-based explosive devices.

5.
J Chromatogr A ; 1308: 96-103, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-23953611

RESUMO

Aerosol detectors provide generally uniform response for most analytes, independent of their optical properties, and have the advantage of being compatible with elevated temperature mobile phases. Therefore, aerosol detectors present an attractive detection alternative for high temperature liquid chromatography (HTLC) separations. The present study has investigated the effects of HTLC conditions using aqueous mobile phases on the detection response of an evaporative light-scattering detector (ELSD) and a corona-charged aerosol detector (C-CAD). The response of the ELSD was increased up to 5-fold by increasing the separation temperature from 30°C to 180°C. The C-CAD showed much smaller increases in response under the same conditions. This increase in response was found not to result from the increased temperature for the mobile phase but rather from compression of the elution bandwidth at elevated temperature. The effect of bandwidth on detector response was confirmed using flow-injection studies in which the same amount of analyte was introduced into the detector at varying bandwidths. Furthermore, it is shown that a temperature gradient can be used to counteract the effects of varying bandwidths associated with isocratic-isothermal separations, with relatively constant bandwidth and detector response being observed with appropriate temperature gradients. This study demonstrates the necessity to consider the elution bandwidth in HTLC-aerosol detector analysis.


Assuntos
Aerossóis/química , Cromatografia Líquida/métodos , Análise de Injeção de Fluxo , Temperatura Alta , Modelos Químicos , Compostos Orgânicos , Solventes
6.
Anal Chim Acta ; 781: 80-7, 2013 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-23684468

RESUMO

A novel capillary electrophoresis (CE) approach has been developed for the simultaneous rapid separation and identification of common environmental inorganic anions and cations from a single sample injection. The method utilised a sequential injection-capillary electrophoresis instrument (SI-CE) with capacitively-coupled contactless conductivity detection (C(4)D) constructed in-house from commercial-off-the-shelf components. Oppositely charged analytes from a single sample plug were simultaneously injected electrokinetically onto two separate capillaries for independent separation and detection. Injection was automated and may occur from a syringe or be directly coupled to an external source in a continuous manner. Software control enabled high sample throughput (17 runs per hour for the target analyte set) and the inclusion of an isolation valve allowed the separation capillaries to be flushed, increasing throughput by removing slow migrating species as well as improving repeatability. Various environmental and industrial samples (subjected only to filtering) were analysed in the laboratory with a 3 min analysis time which allowed the separation of 23 inorganic and small organic anions and cations. Finally, the system was applied to an extended automated analysis of Hobart Southern Water tap water for a period of 48 h. The overall repeatability of the migration times of a 14 analyte standard sample was less than 0.74% under laboratory conditions. LODs ranged from 5 to 61 µg L(-1). The combination of automation, high confidence of peak identification, and low limits of detection make this a useful system for the simultaneous identification of a range of common inorganic anions and cations for discrete or continuous monitoring applications.


Assuntos
Ânions/análise , Cátions/análise , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Sistemas On-Line , Desenho de Equipamento , Metais/análise , Reprodutibilidade dos Testes , Software , Água/análise
7.
Anal Chim Acta ; 750: 199-206, 2012 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-23062441

RESUMO

A range of organic solvents (ethanol, isopropanol and acetone) has been investigated as alternatives to acetonitrile and methanol when used in conjunction with Corona Charged Aerosol Detection (Corona CAD). These solvents have been evaluated with regard to their effect on the response of the Corona CAD. Three dimensional response surfaces were constructed using raw data showing the relationship between detector response, analyte concentration and percentage of organic solvent in the mobile phase, using sucralose or quinine as the test analyte. The detector response was non-linear in terms of analyte concentration for all solvents tested. However, detector response varied in an approximately linear manner with percentage of organic solvent over the range 0-40% for ethanol or isopropanol and 0-80% for acetone and methanol. The chromatographic performance of the various solvents when used as aqueous-organic mobile phases was evaluated for isocratic and gradient separations of sugars and sugar alcohols by hydrophilic interaction liquid chromatography (HILIC) using an Asahipak NH2P-504E column coupled with Corona CAD detection. It was found that whilst acetonitrile provided the highest column efficiencies and lowest detection limits of the solvents studied, acetone also performed well and could be used to resolve the same number of analytes as was possible with acetonitrile. Typical efficiencies and detection limits of 5330 plates m(-1) and 1.25 µg mL(-1), respectively, were achieved when acetone was used as the organic modifier. Acetone was utilised successfully as an organic modifier in the HILIC separation of carbohydrates in a beer sample and also for a partially digested dextran sample.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão , Solventes/química , 2-Propanol/química , Acetona/química , Acetonitrilas/química , Química Verde , Interações Hidrofóbicas e Hidrofílicas , Metanol/química
8.
J Chromatogr A ; 1253: 44-51, 2012 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-22840819

RESUMO

This work forms the final part of a study investigating gradient elution ion-exchange chromatography of pharmaceutically relevant compounds, aiming at achieving complementary selectivity to reversed-phase HPLC. In this study the coupling of three universal detectors (electro-spray ionisation mass spectrometer (ESI-MS); corona charged aerosol detector (CAD); and evaporative light scattering detector (ELSD)) to suppressed IC using complex elution profiles with potassium hydroxide eluents is demonstrated. The non-volatile ions were removed from the eluent by the suppressor prior to detection, thus allowing a stable detector response, especially with the prototype electrolytic suppressor. The detector response for ten weakly anionic pharmaceuticals followed the expected models and the limits of detection obtained were not compromised by the use of a suppressor, yielding values below 50 ng/mL with MS, low to sub µg/mL levels with CAD and 2-20 µg/mL with ELSD (25 µL injections). When coupled to MS and CAD, the prototype electrolytic suppressor showed percentage relative standard deviations (%RSDs) in peak areas of 0.4-2.5% on average, compared to the chemical suppressor which yielded 1.5-3 fold higher %RSD values for the test analytes. The prototype electrolytic suppressor also generally exhibited wider linear response ranges than the chemical suppressor.


Assuntos
Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Preparações Farmacêuticas/análise , Limite de Detecção , Modelos Lineares , Espectrometria de Massas , Modelos Químicos , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes
9.
J Chromatogr A ; 1233: 71-7, 2012 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-22377470

RESUMO

For the hyphenation of ion chromatography to nebulising detectors or mass spectrometry, suppression of the non-volatile ionic eluent to water is a required step to avoid elevated detector baselines. Presented here is a study of three new designs of electrolytic suppressors, incorporating high ion-exchange capacity screens and high ion-exchange capacity membranes in different thickness and compositions. These designs aim to minimise hydrophobic interactions of the suppressor with organic analytes and to provide higher compatibility with eluents containing acetonitrile. In comparison with a commercially available electrolytic suppressor and also a commercially available chemical suppressor, the new high-capacity suppressor showed superior performance, exhibiting minimal interactions with a test set of analytes under the examined conditions. This led to the attainment of high recoveries of the analytes after suppression (93-99% recovery) and significantly reduced band broadening during suppression. The new suppressor has been shown to perform well under both isocratic and gradient elution conditions.


Assuntos
Cromatografia por Troca Iônica/métodos , Eletroquímica/métodos , Preparações Farmacêuticas/análise , Membranas Artificiais
10.
J Chromatogr A ; 1224: 35-42, 2012 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-22239961

RESUMO

For the hyphenation of ion chromatography to nebulising detectors or mass spectrometry, suppression of the non-volatile ionic eluent to water is a required step. However, suppression of weakly acidic or weakly basic organic analytes can potentially lead to losses of analytes during suppression resulting from precipitation, hydrophobic adsorption onto the suppressor, or permeation of the analyte through the suppressor membranes. This study investigates the interactions between the suppressor and weak organic acid analytes, including pharmaceutically related compounds, for eluents containing organic solvent. Correlations were observed between analyte recovery rates after electrolytic suppression and the eluent composition, the suppression conditions, and the physico-chemical properties of the analytes. These results suggest that hydrophobic adsorption interactions occur in the electrolytic suppressor and that these interactions are ameliorated by the addition to the eluent of high levels of organic solvents, especially acetonitrile. Use of eluents containing 80% acetonitrile resulted in very low losses of analyte during suppression. Recovery experiments conducted in various compartments of the electrolytic suppressor showed that some analytes permeated through the suppressor membrane into the regenerant chambers, but this could be prevented by adding organic solvent to the regenerant solution. It was also noted that analyte losses increased with ageing of the electrolytic suppressors. Chemical suppression avoids some of the analyte losses observed with an electrolytic suppressor, but when used under the correct conditions, electrolytic suppressors gave close to equivalent performance to chemical suppressors.


Assuntos
Ácidos Carboxílicos/química , Cromatografia por Troca Iônica/métodos , Preparações Farmacêuticas/química , Adsorção , Interações Hidrofóbicas e Hidrofílicas , Íons/química
11.
J Chromatogr A ; 1218(50): 9080-5, 2011 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-22074647

RESUMO

A multi-dimensional matrix-elimination ion chromatography approach has been applied to the determination of bromate in seawater samples. Two-dimensional and three-dimensional configurations were evaluated for their efficacy to eliminate the interference caused by the high concentration of ubiquitous ions present in seawater, such as chloride and sulfate. A two-dimensional approach utilising a high capacity second dimension separation comprising two Dionex AS24 columns connected in series was applied successfully and permitted the determination of bromate in undiluted seawater samples injected directly onto the ion chromatography system. Using this approach the limit of detection (LOD) for bromate based on a signal to noise ratio of 3 was 1050 µg/L using a 500 µL injection loop. Good linearity was obtained for bromate with correlation coefficients for the calibration curves of 0.9981 and 0.9996 based on peak height and area, respectively. A three-dimensional method utilising two 10-port switching valves to allow sharing of the second suppressor and detector between the second and third dimension separations showed better resolution and detection for bromate and reduced the LOD to 60 µg/L for spiked seawater samples. Good linearity was maintained with correlation coefficients of 0.9991 for both peak height and area. Ozonated seawater samples were also analysed and exhibited a non-linear increase in bromate level on increasing ozonation time. A bromate concentration in excess of 1770 µg/L was observed following ozonation of the seawater sample for 120 min. Recoveries for the three-dimensional system were 92% and 89% based on peak height and area, respectively, taken over 5 ozonated samples with 3 replicates per sample.


Assuntos
Bromatos/análise , Cromatografia por Troca Iônica/métodos , Água do Mar/análise , Cloretos , Limite de Detecção , Ozônio/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sulfatos
12.
J Chromatogr A ; 1218(50): 9037-45, 2011 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-22056240

RESUMO

This overall study aims to investigate gradient elution ion-exchange chromatography of pharmaceutically relevant compounds using universal nebulisation detectors, such as evaporative light scattering detection (ELSD). Addition of organic solvents to the eluent is necessary to minimise hydrophobic adsorption on the polymeric stationary phase and improve solubility of analytes. It is also necessary to de-salt the eluent prior to detection, and in this work, ion chromatography suppressors were used for this step. Such suppressors have been designed for aqueous eluents, so the purpose of the present study was to investigate the effects of methanol and acetonitrile on suppressor performance. Chemical and electrolytic suppressors were evaluated for baseline drift, noise and efficiency of suppression using aqueous/organic eluents containing up to 40% (v/v) methanol or acetonitrile. Chemical suppression of aqueous/organic eluents showed minimal noise levels, uniform low baseline and low gradient drift. Electrolytic suppression gave good performance, but with higher baseline conductivity levels and baseline drift than chemical suppression. The elevated baseline was found not to be caused by incomplete suppression of the eluent, but was attributed to chemical reactions involving the organic solvents and facilitated by high electric currents and heat generation. It was demonstrated that suppressed ion-exchange separation using a complex KOH elution profile could be coupled with ELSD, with the suppressor effectively de-salting the eluent, producing a stable baseline. Finally, complementary separation selectivity was demonstrated using a set of pharmaceutically related organic acids separated by reversed-phase and ion-exchange methods.


Assuntos
Cromatografia por Troca Iônica/métodos , Compostos Orgânicos/química , Preparações Farmacêuticas/química , Acetonitrilas , Cromatografia por Troca Iônica/instrumentação , Cromatografia de Fase Reversa , Desenho de Equipamento , Hidróxidos , Luz , Modelos Lineares , Metanol , Preparações Farmacêuticas/análise , Compostos de Potássio , Espalhamento de Radiação , Solventes/química
13.
Anal Chem ; 83(23): 9068-75, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22004519

RESUMO

A simple sequential injection capillary electrophoresis (SI-CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) has been developed for the rapid separation of anions relevant to the identification of inorganic improvised explosive devices (IEDs). Four of the most common explosive tracer ions, nitrate, perchlorate, chlorate, and azide, and the most common background ions, chloride, sulfate, thiocyanate, fluoride, phosphate, and carbonate, were chosen for investigation. Using a separation electrolyte comprising 50 mM tris(hydroxymethyl)aminomethane, 50 mM cyclohexyl-2-aminoethanesulfonic acid, pH 8.9 and 0.05% poly(ethyleneimine) (PEI) in a hexadimethrine bromide (HDMB)-coated capillary it was possible to partially separate all 10 ions within 90 s. The combination of two cationic polymer additives (PEI and HDMB) was necessary to achieve adequate selectivity with a sufficiently stable electroosmotic flow (EOF), which was not possible with only one polymer. Careful optimization of variables affecting the speed of separation and injection timing allowed a further reduction of separation time to 55 s while maintaining adequate efficiency and resolution. Software control makes high sample throughput possible (60 samples/h), with very high repeatability of migration times [0.63-2.07% relative standard deviation (RSD) for 240 injections]. The separation speed does not compromise sensitivity, with limits of detection ranging from 23 to 50 µg·L(-1) for all the explosive residues considered, which is 10× lower than those achieved by indirect absorbance detection and 2× lower than those achieved by C(4)D using portable benchtop instrumentation. The combination of automation, high sample throughput, high confidence of peak identification, and low limits of detection makes this methodology ideal for the rapid identification of inorganic IED residues.

14.
J Chromatogr A ; 1218(32): 5512-9, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21741652

RESUMO

Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.


Assuntos
Cromatografia por Troca Iônica/métodos , Ânions/análise , Cátions/análise , Cromatografia por Troca Iônica/instrumentação
15.
J Chromatogr A ; 1218(20): 3007-12, 2011 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-21481882

RESUMO

There are many methods available to detect and positively identify either organic or inorganic explosives separately, however no one method has been developed which can detect both types of explosive species simultaneously from a single sample. In this work, a unique coupled-chromatographic system is reported for the simultaneous determination of both organic and inorganic explosive species and is used for pre-blast analysis/identification purposes. This novel approach is based on the combination of reversed-phase high performance liquid chromatography and ion chromatography which allows trace levels of organic and inorganic explosives to be determined simultaneously from a single sample. Using this procedure, a 20 min reversed-phase separation of organic explosives is coupled to a 16 min ion-exchange separation of anions present in inorganic explosives, providing a complete pre-blast analysis/identification system for the separation and detection of a complex mixture containing organic and/or inorganic explosive species. The total analysis time, including sufficient column re-equilibration between runs, was <25 min using the coupled system. By this method, the minimum resolution for the organic separation was 1.16 between nitroglycerin and tetryl and the detection limits ranged from 0.31 mg L(-1) for cyclotetramethylene tetranitramine (HMX) and 1.54 mg L(-1) for pentaerythrite tetranitrate (PETN), while the minimum resolution for the inorganic separation was 0.99 between azide and nitrate, and the detection limits ranged from 7.70 µg L(-1) for fluoride and 159.50 µg L(-1) for benzoate.


Assuntos
Cromatografia por Troca Iônica/métodos , Cromatografia de Fase Reversa/métodos , Substâncias Explosivas/análise , Compostos Inorgânicos/análise , Compostos Orgânicos/análise , Substâncias Explosivas/isolamento & purificação , Compostos Inorgânicos/isolamento & purificação , Compostos Orgânicos/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Terrorismo
16.
J Chromatogr A ; 1218(12): 1646-55, 2011 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-21315361

RESUMO

The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 µL.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão/métodos , Nebulizadores e Vaporizadores , Cromatografia Líquida de Alta Pressão/instrumentação , Luz , Modelos Químicos , Espalhamento de Radiação , Sensibilidade e Especificidade , Temperatura
17.
J Chromatogr A ; 1217(47): 7418-27, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-20961549

RESUMO

The universality of the response of the Corona Charged Aerosol Detector (CoronaCAD) has been investigated under flow-injection and gradient HPLC elution conditions. A three-dimensional model was developed which relates the CoronaCAD response to analyte concentration and the mobile phase composition used. The model was developed using the response of four probe analytes which displayed non-volatile behavior in the CoronaCAD and were soluble over a broad range of mobile phase compositions. The analyte concentrations ranged from 1µg/mL to 1mg/mL, and injection volumes corresponded to on-column amounts of 25ng to 25µg. Mobile phases used in the model were composed of 0-80% acetonitrile, mixed with complementary proportions of aqueous formic acid (0.1%, pH 2.6). An analyte set of 23 compounds possessing a wide range of physicochemical properties was selected for the purpose of evaluating the model. The predicted response was compared to the actual analyte response displayed by the detector and the efficacy of the model under flow-injection and gradient HPLC elution conditions was determined. The average error of the four analytes used to develop the model was 9.2% (n=176), while the errors under flow-injection and gradient HPLC elution conditions for the evaluation set of analytes were found to be 12.5% and 12.8%, respectively. Some analytes were excluded from the evaluation set due to considerations of volatility (boiling point <400°C), charge and excessive retention on the column leading to elution outside the eluent range covered by the model. The two-part response model can be used to describe the relationship between response and analyte concentration and also to offer a correction for the non-linear detector response obtained with gradient HPLC for analytes which conform to the model, to provide insight into the factors affecting the CoronaCAD response for different analytes, and also as a means for accurately determining the concentration of unknown compounds when individual standards are not available for calibration.


Assuntos
Aerossóis/análise , Cromatografia Líquida de Alta Pressão/instrumentação
18.
J Chromatogr A ; 1217(39): 6069-76, 2010 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-20732686

RESUMO

The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed t(R) vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.


Assuntos
Cromatografia por Troca Iônica/métodos , Metanol/química , Modelos Químicos , Preparações Farmacêuticas/química , Ânions/química , Cátions/química , Hidróxidos/química , Modelos Lineares , Mesilatos/química , Compostos de Potássio/química
19.
J Chromatogr A ; 1217(20): 3452-6, 2010 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-20394938

RESUMO

The use of a functionalized latex nanoparticle coating as a new sorbent phase for solid-phase microextraction (SPME) was examined. By means of electrostatic absorption onto ionized silanol groups, a fused-silica rod was coated with polymeric nanoparticles functionalized with quaternary ammonium groups. Optimum conditions for the preparation of the coated fibre are presented. The fibre was used for the extraction of a mixture of seven anions from water samples which are analysed by coupling the SPME fibre to an ion chromatographic system via a special interface. The results obtained proved the suitability of this novel coating as a new SPME fibre. A linear calibration for the target analytes was achieved over the concentration range from 5 microg L(-1) to 5 mg L(-1) (r(2)>0.988), while limits of detection for these ions were all below 3.7 microg L(-1) (S/N=3). The reproducibility of a single fibre (n=4) under similar conditions was between 7 and 12%, while the fibre to fibre reproducibility (n=5) was between 8.9 and 14%.


Assuntos
Ânions/análise , Látex/química , Nanopartículas/química , Microextração em Fase Sólida/métodos , Água/análise , Microscopia Eletrônica de Varredura , Modelos Teóricos
20.
J Chromatogr A ; 1216(38): 6600-10, 2009 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-19683244

RESUMO

The ion-exchange separation of organic anions of varying molecular mass has been demonstrated using ion chromatography with isocratic, gradient and multi-step eluent profiles on commercially available columns with UV detection. A retention model derived previously for inorganic ions and based solely on electrostatic interactions between the analytes and the stationary phase was applied. This model was found to accurately describe the observed elution of all the anions under isocratic, gradient and multi-step eluent conditions. Hydrophobic interactions, although likely to be present to varying degrees, did not limit the applicability of the ion-exchange retention model. Various instrumental configurations were investigated to overcome problems associated with the use of organic modifiers in the eluent which caused compatibility issues with the electrolytically derived, and subsequently suppressed, eluent. The preferred configuration allowed the organic modifier stream to bypass the eluent generator, followed by subsequent mixing before entering the injection valve and column. Accurate elution prediction was achieved even when using 5-step eluent profiles with errors in retention time generally being less than 1% relative standard deviation (RSD) and all being less than 5% RSD. Peak widths for linear gradient separations were also modelled and showed good agreement with experimentally determined values.


Assuntos
Ânions/química , Cromatografia por Troca Iônica/métodos , Preparações Farmacêuticas/isolamento & purificação , Cromatografia por Troca Iônica/instrumentação , Interações Hidrofóbicas e Hidrofílicas , Modelos Químicos , Compostos Orgânicos/química , Compostos Orgânicos/isolamento & purificação , Preparações Farmacêuticas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA