1.
Urol J ; 18(5): 561-563, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33236335

RESUMO

PURPOSE: To detect possible effects of magnetic resonance imaging (MRI) scans on the function of an InterStim Twin sacral nerve stimulation (SNS) device and on patient's health. There is no authorization for MRI scans in InterStim Twin SNS at all. MATERIAL AND METHODS: 10 patients with Interstim Twin sacral nerve stimulator implants underwent a singular MRI scan. Before the MRI was performed, the SNS device function was evaluated and the device was deactivated be the implanting urologist. A continuous monitoring took place during MRI procedure. Micturition-time chart pre- and post MRI procedures were conducted. After the MRI session was completed, the implanted device was examined once more and reactivated, function then was evaluated. RESULTS: A total of 10 patients required MRI examinations in 8 different body regions. No patient reported pain or discomfort during and after the MRI scan. After reactivation of the InterStim Twin device following the MRI, impedances and stimulation amplitude, micturition frequency, urgency, and incontinence episodes remained stable. No significant differences between pre- and post MRI were found (p>0.05). CONCLUSION: This is the first report of patients successfully undergoing a MRI scan despite a previously implanted Interstim Twin sacral nerve stimulator. No negative effect of SNS function or negative side effects for the patients were observed.


Assuntos
Terapia por Estimulação Elétrica , Sintomas do Trato Urinário Inferior/terapia , Plexo Lombossacral , Imageamento por Ressonância Magnética , Transtornos Urinários/terapia , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Feminino , Humanos , Plexo Lombossacral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Retrospectivos
2.
Neurourol Urodyn ; 39(8): 2368-2372, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32886804

RESUMO

AIM: The aim of this study was to assess possible impacts of multiple magnetic resonance imaging (MRI) scans on the function of InterStim™ sacral neurostimulator systems (SNS; Medtronic Inc.) devices and on patient's safety. METHODS: Over the course of 17 years, a total of 16 patients required 72 MRI examinations in various parts of the body. Each time an MRI was performed, the implanting urologist evaluated the SNS device function and deactivated the implant before the scan. Patients were monitored continuously during and after the procedure. After the MRI session, the site of the implanted device was examined, and the SNS device was reactivated. RESULTS: None of the patients experienced pain or discomfort during or after the MRI scan. Impedances and stimulation amplitudes were recorded before and after MRI and showed no statistically significant changes regarding implant function. Micturition-time charts after MRI procedures were compared with previous records and showed no deviations either. No negative consequences of multiple MRIs have been observed. CONCLUSION: This is the first report of patients successfully undergoing multiple MRI scans despite a previously implanted SNS. Sixteen patients underwent more than one MRI scan, with no negative effect on the functional outcome of SNS or negative side effects for the patients.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sacro
3.
Urology ; 115: 151-156, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29526510

RESUMO

OBJECTIVE: To compare prostate volume and prostate-specific antigen (PSA) levels with bacterial growth in prostate tissue cultures. MATERIALS AND METHODS: Fifty male patients who underwent transurethral prostate resection were investigated prospectively. Resection chips from the prostate gland were added to brain-heart infusion medium and incubated. PSA levels were determined preoperatively at our urology ward. The prostate gland volume was estimated by transabdominal ultrasound examination preoperatively. RESULTS: Persons with positive bacterial prostate tissue cultures have a greater prostate volume. This is significant in patients with and without histopathologic signs of prostatitis. Persons with positive bacterial prostate tissue cultures have higher PSA values. This is significant in patients without histopathologic signs of prostatitis. CONCLUSION: People with positive bacterial prostatic tissue culture have a higher prostate volume in comparison with patients with negative culture findings and show a tendency toward increased PSA levels as well.


Assuntos
Antígeno Prostático Específico/sangue , Próstata/microbiologia , Próstata/patologia , Hiperplasia Prostática/patologia , Neoplasias da Próstata/patologia , Prostatite/patologia , Idoso , Idoso de 80 Anos ou mais , Bactérias/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Próstata/cirurgia , Hiperplasia Prostática/sangue , Hiperplasia Prostática/microbiologia , Hiperplasia Prostática/cirurgia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/microbiologia , Neoplasias da Próstata/cirurgia , Prostatite/sangue , Prostatite/complicações , Prostatite/microbiologia , Técnicas de Cultura de Tecidos , Ressecção Transuretral da Próstata