Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Mal Coeur Vaiss ; 96(1): 62-5, 2003 Jan.
Artigo em Francês | MEDLINE | ID: mdl-12613153

RESUMO

We report the case of a female patient of 76 years old admitted to our hospital for a pre-operative assessment of a symptomatic mitral regurgitation (MR) whose transthoracic echocardiography revealed only a trivial regurgitation. The occurrence during hospital stay of an acute pulmonary edema contemporary to the occurrence of a huge MR permitted to suspect the diagnosis of a paroxystic ischemic MR. Angiographic and hemodynamic evaluation revealed only a non-significant atheromateous plaque located in the distal LAD. The infusion of Methylergometrine triggered a severe spasm at the site of that plaque, associated with a huge MR visualized by TTE with restricted movements of both leaflets, responsible for an acute pulmonary edema occurring on the table of the catheterization laboratory. Recovery was quickly obtained after intravenous injection of Nitroglycerin, which removed the spasm and valvular regurgitation. The diagnosis of paroxystic ischemic mitral regurgitation was confirmed and a treatment based on high dosage of calcium-blocker was decided. After a follow-up of more than one year, the patient remains asymptomatic and the regurgitation has never occurred.


Assuntos
Vasoespasmo Coronário/complicações , Idoso , Arteriosclerose/complicações , Bloqueadores dos Canais de Cálcio/uso terapêutico , Cateterismo Cardíaco , Vasoespasmo Coronário/tratamento farmacológico , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral , Isquemia Miocárdica/etiologia , Nitroglicerina/uso terapêutico , Edema Pulmonar/etiologia , Vasodilatadores/uso terapêutico
2.
Arch Mal Coeur Vaiss ; 94(2): 110-6, 2001 Feb.
Artigo em Francês | MEDLINE | ID: mdl-11265548

RESUMO

The study of the convergence zone by echocardiography is a validated method of quantification of native valve mitral regurgitation. However, there is little data concerning its applications to paraprosthetic mitral regurgitation. The aim of this study was to evaluate the method in this indication. Thirty consecutive patients (21 mechanical and 9 bioprostheses) with paraprosthetic mitral regurgitation quantified by transoesophageal echocardiography were included: 4 mild, 13 moderate and 13 severe. The regurgitant volume RV) and the regurgitant surface area (RSA) were calculated by the following formulae: RV = 2 pi.r2.Va.t.alpha/180 and RSA = RV/VTI (r: mid systolic radius of the convergence zone, Va: aliasing velocity, t: regurgitation time, alpha/180: the angular correction due to parietal stress, VTI: velocity time integral of the regurgitant flow). The feasibility of the calculation of the RV and RSA was 93 and 63% respectively. There was a statistically significant correlation between the RV and transoesophageal echocardiography (r: 0.85, p < 0.001), between RSA and transoesophageal echocardiography (r: 0.67, p < 0.05) and between RV and RSA (r: 0.95, p < 0.001). When severe paraprosthetic regurgitation was defined by a RV greater than 60 ml and RSA greater than 40 mm2, the concordance between RV, RSA and transoesophageal echocardiography was 75% and 74% respectively. Therefore, the study of the convergence zone provides an accurate evaluation of paraprosthetic mitral regurgitation by transthoracic echocardiography.


Assuntos
Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Frequência Cardíaca , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Período Pós-Operatório , Desenho de Prótese , Reprodutibilidade dos Testes
3.
Pacing Clin Electrophysiol ; 23(3): 410-2, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10750147

RESUMO

A patient with Brugada syndrome experienced incessant ventricular fibrillation 7 years after implantation of an ICD. General anesthesia, fast ventricular pacing, bretylium, and atenolol infusion were ineffective; amiodarone infusion was started. After 190 defibrillation shocks over 36 hours, the electrical storm stopped. A multiorgan failure occurred as a complication of the electrical storm and necessitated prolonged reanimation. Thorough cardiac evaluation revealed no structural abnormality and the patient, now on chronic oral amiodarone therapy, remains free of arrhythmia 1 year after the event.


Assuntos
Bloqueio de Ramo/terapia , Desfibriladores Implantáveis , Eletrocardiografia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia , Adulto , Bloqueio de Ramo/complicações , Eletrofisiologia , Humanos , Masculino , Síndrome , Fibrilação Ventricular/complicações
4.
Pacing Clin Electrophysiol ; 21(12): 2699-700, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9894667

RESUMO

Extraction of three chronically implanted pacemaker leads was performed via the implant vein in a 71-year-old man. One of the leads broke in the subclavian scar tissue. The lead fragment migrated into the left peroneotibial trunk artery. Transesophageal echocardiography showed patent foramen ovale associated with right-to-left atrial shunt. This complication of lead extraction is discussed along with the role of echocardiography prior to lead removal.


Assuntos
Embolia Paradoxal/etiologia , Complicações Intraoperatórias/etiologia , Perna (Membro)/irrigação sanguínea , Marca-Passo Artificial/efeitos adversos , Idoso , Ecocardiografia Transesofagiana , Embolia Paradoxal/complicações , Fluoroscopia , Comunicação Interatrial/complicações , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...