RESUMO

Potassium ion (K+) plays an important role in the maintenance of cellular biological process for human health. Thus, the detection of K+ is very important. Here, based on the interaction between thiamonomethinecyanine dye and G-quadruplex formation sequence (PW17), K+ detection spectrum was characterized by UV-Vis spectrometry. The single-stranded sequence of PW17 can fold into G-quadruplex in the presence of K+. PW17 can induce a dimer-to-monomer transition of the absorption spectrum of cyanine dyes. This method shows high specificity against some other alkali cations, even at high concentrations of Na+. Further, this detection strategy can realize the detection of K+ in tap water.


Assuntos
DNA , Quadruplex G , Humanos , DNA/genética , DNA/química , Análise Espectral , Corantes Fluorescentes/química , Potássio/análise
2.
Biomed Environ Sci ; 29(5): 379-84, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27353713

RESUMO

Case reports of indium-related lung disease in workers have raised public concern to the human toxicity of indium (In) and its compounds. However, studies evaluating the exposure or health of workers in In smelting plants are rare. Therefore, in this study, we focused on four In smelting plants, with the main objective of characterizing In in smelter plants in China and discussing the potential exposure biomarkers of In exposure. We recruited 494 subjectsat four In smelting plants in China. Personal air samples, first morning urine and spot blood samples were collected. In concentrations in samples were analyzed using inductively coupled plasma mass spectrometry. In concentrations in air samples did not exceed the permissible concentration-time weighed average, but the smelter workers had a higher internal exposure to In. Positive correlations were observed between the air In and urine In concentrations, and between the air In and blood In concentrations. This study provides basic data for the following In exposure and health risk assessment.


Assuntos
Poluentes Ocupacionais do Ar/sangue , Poluentes Ocupacionais do Ar/urina , Índio/sangue , Índio/urina , Metalurgia , Exposição Ocupacional , Adulto , Biomarcadores/sangue , Biomarcadores/urina , China , Monitoramento Ambiental , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Adulto Jovem
3.
Environ Res ; 140: 10-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25836720

RESUMO

Baseline blood concentrations of metals are important references for monitoring metal exposure in environmental and occupational settings. The purpose of this study was to determine the blood levels of manganese (Mn), copper (Cu), zinc (Zn), lead (Pb), and cadmium (Cd) among the residents (aged 12-60 years old) living in the suburb southwest of Beijing in China and to compare the outcomes with reported values in various developed countries. Blood samples were collected from 648 subjects from March 2009 to February 2010. Metal concentrations in the whole blood were determined by ICP-MS. The geometric means of blood levels of Mn, Cu, Zn, Pb and Cd were 11.4, 802.4, 4665, 42.6, and 0.68 µg/L, respectively. Male subjects had higher blood Pb than the females, while the females had higher blood Mn and Cu than the males. There was no gender difference for blood Cd and Zn. Smokers had higher blood Cu, Zn, and Cd than nonsmokers. There were significant age-related differences in blood levels of all metals studied; subjects in the 17-30 age group had higher blood levels of Mn, Pb, Cu, and Zn, while those in the 46-60 age group had higher Cd than the other age groups. A remarkably lower blood level of Cu and Zn in this population as compared with residents of other developed countries was noticed. Based on the current study, the normal reference ranges for the blood Mn were estimated to be 5.80-25.2 µg/L; for blood Cu, 541-1475 µg/L; for blood Zn, 2349-9492 µg/L; for blood Pb, <100 µg/L; and for blood Cd, <5.30 µg/L in the general population living in Beijing suburbs.


Assuntos
Exposição Ambiental , Metais/sangue , População Suburbana , Adolescente , Adulto , Criança , China , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Fumar , Adulto Jovem
4.
Zhonghua Yu Fang Yi Xue Za Zhi ; 46(8): 679-82, 2012 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-23157858

RESUMO

OBJECTIVE: To evaluate the chromium (Cr) levels in blood and urine among general population in China between 2009 and 2010, and thereby to analyze its prevalent features. METHODS: From year 2009 to 2010, a total of 11 983 subjects of general population aged between 6 and 60 year-old were recruited from 24 districts in 8 provinces in eastern, central and western China mainland, by cluster random sampling method. The information about their living environment and health status were collected by questionnaire, and 11 983 blood samples and 11 853 urine samples were also collected. Inductively coupled plasma mass spectrometry (ICP-MS) was applied to test the Cr level both in blood and urine; and the Cr distribution in blood and urine among groups of population in different ages, genders and districts, were then analyzed. RESULTS: Among general population in China, the geometric mean (GM) of Cr concentration in blood was 1.19 µg/L, with median at 1.74 µg /L and 95% percentile at 5.59 µg/L. The Cr concentration in blood among males and females were separately 1.18 µg/L and 1.20 µg/L(P > 0.05); while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 1.00, 1.22, 1.01, 1.40, 1.27 and 1.30 µg/L (P < 0.01), respectively; and the figures in populations from eastern, central and western China were 1.00, 1.70 and 1.98 µg/L (P < 0.01), respectively. Among general population, the GM of Cr concentration in urine was 0.53 µg/L, with median was lower than 0.42 µg/L and 95% percentile at 3.53 µg/L. The Cr concentration in urine among males and females were separately 0.52 µg/L and 0.53 µg/L (P > 0.05);while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 0.56, 0.60, 0.52, 0.50, 0.52 and 0.46 µg/L (P < 0.01), respectively;and the figures in populations from eastern, central and western China were 0.58, < 0.42 and 0.60 µg/L (P < 0.01), respectively. CONCLUSION: The study reported the Cr levels in blood and urine among general population in China, and thereby provided basic data evidence for the following Cr biological monitoring studies in near future.


Assuntos
Cromo/sangue , Cromo/urina , Vigilância da População , Adolescente , Adulto , Criança , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Zhonghua Yu Fang Yi Xue Za Zhi ; 46(8): 745-9, 2012 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-23157872

RESUMO

OBJECTIVE: To establish an inductively coupled plasma mass spectrometry(ICP-MS) method for determination of 30 trace elements including As, Ba, Be, Bi, Ni, Cd, Co, Cr, Cs, Cu, Ga, Mn, Pb, Sr, Tl, V, Ge, Mo, Nb, Ti, W, Te, Se, Zr, In, Sb, Hg, Ce, La, and Sm in human blood. METHOD: The blood samples were analyzed by ICP-MS after diluted 1/10 with 0.01% Triton-X-100 and 0.5% nitric acid solution. Y, Rh and Lu were selected as internal standard in order to correct the matrix interference of Cr, As, Se, and Hg by a hex pole-based collision-reaction cell. Other elements were determined with standard method. The limits of detection, precision and accuracy of the method were evaluated. The accuracy was validated by the determination of the whole blood reference material. RESULTS: All the 30 trace elements have good linearity in their determination range, with the correlation coefficient > 0.9999. The limits of detection of the 30 trace elements were in the range of 1.19 - 2.15 µg/L and the intra-precision and inter-precision (relative standard deviation, RSD) were less than 14.3% (except Hg RSD < 21.2%, and Ni RSD < 15.4%). The spiked recovery for all elements fell within 59.3% - 119.2%. Among the 13 whole blood reference materials, V, Cr, Mn, Co, Ni, Cu, As, Se, Cd, Te, and Pb (1.45, 1.19, 18.40, 0.18, 1.57, 591.00, 2.97, 61.00, 0.35, 1.86, and 9.70 µg/L respectively) fell within the acceptable range and the detection results of Hg (0.59 µg/L) and Mo (1.59 µg/L) were slightly beyond the range. CONCLUSION: This method was simple, fast and effective. It can be used to monitor the multi-elementary concentration in human blood.


Assuntos
Espectrometria de Massas/métodos , Metaloides/sangue , Metais/sangue , Humanos , Limite de Detecção , Oligoelementos/sangue
6.
Artigo em Chinês | MEDLINE | ID: mdl-22096863

RESUMO

OBJECTIVE: A sampling method was established to collect diborane in the air of workplace and an ICP-AES method was developed to determine the Boron in desorbed solution. METHOD: Diborane in the air of workplace was collected by solid sorbent tube filled with oxidant impregnated activated carbon. The adsorbed diborane was desorbed into 3% H2O2 aqueous, and then the desorbed Boron was determined by ICP-AES. RESULTS: The sampling efficiency of this method was 99.6% with the desorption efficiency of diborane with 5.660 microg and 56.6 microg spiked were 90.9% and 99.5%, respectively. Both the intra-and inter-precision RSD were less than 8%. The standard curve of this method ranged from 0.1 to 10.0 microg/ml (Boron), and the LOD and LOQ were 0.011 mg/m3 and 0.035 mg/m3 (15L samples) respectively. CONCLUSION: The method established was suitable for diborane sampling and determination in the air of workplace.


Assuntos
Poluentes Ocupacionais do Ar/análise , Boroidretos/análise , Espectrofotometria Atômica/métodos , Monitoramento Ambiental/métodos , Local de Trabalho