Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
3.
Zhonghua Nei Ke Za Zhi ; 61(4): 390-396, 2022 Apr 01.
Artigo em Chinês | MEDLINE | ID: mdl-35340185

RESUMO

Objective: To explore the correlation between blood glucose levels and the three factors of sarcopenia (muscle mass, strength and function) in older Chinese community dwellers. Methods: This is a retrospective study conducted by collecting the data of patients in Jiangsu Huaqiao Road Community Health Service Center from 2018 to 2019. Two hundred and fifty people aged 60 years or elder were selected. Among them, 101 were men and 149 were women. According to the American Diabetes Association diagnostic criteria for diabetes mellitus in 2018, they were divided into normal glucose tolerance (NGT) group, pre-diabetes group and diabetes group. The patients were assessed for sarcopenia as well. Results: Compared with those in the NGT group, muscle mass and upper limb muscle strength did not change in the diabetic group, but lower limb muscle strength and body function [walking speed, balance, short physical performance battery (SPPB)] decreased significantly in the diabetic group. Pearson correlation analyses showed that fasting plasma glucose(FPG) was negatively correlated with walking speed (r=-0.248, P=0.001), three-pose balance (r=-0.166, P=0.013) and SSPB (r=-0.213, P=0.001). Glycosylated hemoglobin A1c(HbA1c) was positively correlated with sitting and standing time (r=0.205, P=0.002), and negatively correlated with three-pose balance (r=-0.186, P=0.006) and SSPB (r=-0.154, P=0.024). Multiple regression analyses showed that FPG was negatively associated with walking speed (ß=-0.125, P=0.005) and SPPB (ß=-0.034, P=0.012), and that HbA1c was positively associated with sitting and standing time (ß= 0.218, P =0.006) and negatively associated with three-pose balance (ß=-0.143, P=0.012), and SPPB (ß=-0.117, P =0.036). Conclusions: There is no significant correlation between blood glucose levels and muscle mass in the elderly; however, FPG is closely correlated with gait speed, and HbA1c is closely correlated with muscle strength of lower limbs and balance ability in the elderly.


Assuntos
Glicemia , Sarcopenia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Força Muscular/fisiologia , Músculos , Estudos Retrospectivos , Sarcopenia/diagnóstico
4.
Zhonghua Er Ke Za Zhi ; 60(2): 129-133, 2022 Feb 02.
Artigo em Chinês | MEDLINE | ID: mdl-35090230

RESUMO

Objective: To clarify the molecular basis of patients with Bartter syndrome type I and explore the therapeutic effect of trafficking-defective variations by chemical chaperone 4-Phenylbutyric acid(4-PBA). Methods: The clinical characteristics, laboratory findings and genetic data of 3 patients diagnosed with Bartter syndrome type I who were admitted to Department of Nephrology, Children's Hospital of Nanjing Medical University from 2017 to 2018 were retrospectively analyzed. Wild type and variant SLC12A1 gene constructs were transiently overexpressed in HEK293 cells. Western blotting was used to detect the expression levels of Na+-K+-2Cl-cotransporter(NKCC2) protein. Immunofluorescent staining was applied to investigate the subcellular localization of NKCC2 protein. In addition, the effect of the chemical chaperone 4-PBA on the expression and localization of the SLC12A1 gene variants was investigated. Unpaired t test was used for statistical analysis of 4-PBA treatment. Results: All the 3 patients (2 males and 1 female), aged 3.0, 4.0 and 1.2 years, respectively. All patients had antenatal onset with polyhydramnios and were born prematurely. After birth, all patients presented with hypochlorine alkalosis accompanied by hypokalemia and hyponatremia. Sequencing analysis revealed that the 3 patients were homozygotes or compound heterozygotes for variants in the SLC12A1 gene. In HEK293 cells, the surface expression of NKCC2 in 3 variants (p.L463S, p.L479V, p.507-510del) are all lower than in wild type (0.718±0.039, 0.287±0.081, 0.025±0.156 vs. 1.001±0.028, t=5.92, 8.35, 30.49, all P<0.01). Moreover, the total protein expression of p.L479V and p.507-510del group were all lower than that in wild type group (0.630±0.032, 0.043±0.003 vs. 1.000±0.111, t=3.21, 8.65, all P<0.05). 4-PBA treatment increased the mature protein expression level of the p.L463S and p. L479V group in 4-PBA treatment group are all higher than the untreated group (0.459±0.018 vs. 1.123±0.024, 0.053±0.012 vs. 1.256±0.037, t=2.75, 18.35, all P<0.05). Cytoplasmic retention of the L479V and 507-510del variants were observed by immunofluorescent staining. 4-PBA treatment could rescue a number of NKCC2 L479V variants to the membrane. Conclusions: The 3 SLC12A1 variants cause expression or subcellular localization defects of the protein. The findings that plasma membrane expression and activity can be rescued by 4PBA might help to develop novel therapeutic strategy for Bartter syndrome type Ⅰ.


Assuntos
Síndrome de Bartter , Síndrome de Bartter/genética , Pré-Escolar , Feminino , Células HEK293 , Homozigoto , Humanos , Lactente , Masculino , Gravidez , Estudos Retrospectivos , Membro 1 da Família 12 de Carreador de Soluto/genética
5.
Zhonghua Yi Xue Za Zhi ; 101(7): 498-503, 2021 Feb 23.
Artigo em Chinês | MEDLINE | ID: mdl-33631895

RESUMO

Objective: To analyze the characteristic changes of corneal nerve fibers in patients with Parkinson's disease (PD) by corneal confocal microscopy (CCM) and investigate the association of corneal nerve fiber parameters with disease severity and motor symptoms. Methods: Forty-two patients with PD were recruited from the Department of Neurology, Henan University People's Hospital from June 2018 to October 2019. Meanwhile, 40 healthy controls who visited the hospital for physical examination at the same period were enrolled. Corneal nerve fibers in both eyes of all participants were detected by using CCM. The differences of corneal nerve fibers were comparatively analyzed between PD group and healthy controls. Associations of corneal nerve parameters with clinical characteristics such as course of disease, Hoehn and Yahr stage (H-Y stage), unified Parkinson disease rating scale (UPDRS), levodopa equivalent daily dosage (LEDD) were analyzed by using partial correlations. The receiver operating characteristic (ROC) curve was used to analyze the capability of corneal nerve fibers for distinguishing patients with PD from healthy controls. Results: Corneal nerve fiber density (CNFD) in PD group ((19±3)/mm2) was significantly decreased compared with healthy controls ((28±4)/mm2) (t=10.798, P<0.001). However, corneal nerve branch density (CNBD) was significantly increased in PD group ((25±11)/mm2) compared with healthy controls ((18±6)/mm2) (t=-3.427, P=0.001). Meanwhile, corneal nerve fiber length (CNFL) was decreased in PD group ((11.0±2.5) mm/mm2) in comparison with healthy controls ((12.5±1.6) mm/mm2) (t=3.139, P=0.002). ROC curve analysis revealed that CNFD could discriminate PD patients from healthy controls, with an area under the curve of 0.961 3 (95%CI: 92.42-99.84, P<0.000 1). CNFD was negatively correlated with H-Y stage and UPDRS-Ⅲ (r=-0.501 and -0.399, both P<0.05). CNBD was significantly negatively associated with H-Y stage, UPDRS-Ⅲ and UPDRS-Total (r=-0.622, -0.394 and -0.354, respectively, all P<0.05). CNFL was negatively correlated with H-Y stage, UPDRS-Ⅲ and UPDRS-total (r=-0.574, -0.484 and -0.422, respectively, all P<0.05). Conclusion: Small nerve fiber injuries exist in PD patients. Corneal nerve fibers negatively correlates with motor symptoms. CNFD have a good discriminative power to distinguish PD patients from healthy controls and may serve as a marker for PD.


Assuntos
Doença de Parkinson , Córnea , Humanos , Levodopa , Microscopia Confocal , Fibras Nervosas
6.
Arch Osteoporos ; 11: 5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26754792

RESUMO

UNLABELLED: The trabecular bone score (TBS) was obtained from the gray levels of a dual X-ray absorptiometry (DXA) image to evaluate bone microarchitecture. Here, we established the reference plots of TBS in healthy Chinese women of Nanjing area. The TBS references are similar with French and US Caucasian women but higher than Japanese women. PURPOSE: The aim of the study was to establish the reference plots of the TBS in healthy Chinese women of the Nanjing area. METHODS: A total of 537 healthy Chinese women of the Nanjing area were recruited, and the study was approved by the Ethics Committee of the First Affiliated Hospital with Nanjing Medical University. The TBS of the lumbar spine and the bone mineral density (BMD) of the lumbar spine and femur were measured using dual X-ray absorptiometry. The mean ± standard deviation (SD) of the TBS in women with different age groups was calculated. The correlation of TBS and age and BMD was calculated using regression analysis. RESULTS: The reference plots of the TBS were established in healthy Chinese women of the Nanjing area between the ages of 20 and 89 years. The average TBS for total subjects was 1.32 ± 0.11 and reached the peak at the age of 20-29 years and then decreased with age thereafter. The determinant coefficient between TBS and age was 0.5065 while between TBS and BMD was 0.5191. After adjusting for lumbar total BMD, the TBS significantly correlated with age in whole subjects and only in the subgroup of ages 50-59 years. CONCLUSIONS: This study suggested that TBS decreased with age and correlated positively with BMD. The TBS reference of Chinese women is similar with those of French and US Caucasian women but higher than that of Japanese women. Furthermore, the TBS may be more significantly applied in women in menopause for less than 10 years.


Assuntos
Densidade Óssea/fisiologia , Osso e Ossos/anatomia & histologia , Absorciometria de Fóton/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático/etnologia , Osso e Ossos/diagnóstico por imagem , China/etnologia , Feminino , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Humanos , Vértebras Lombares/diagnóstico por imagem , Pessoa de Meia-Idade , Valores de Referência , Análise de Regressão , Adulto Jovem
7.
Panminerva Med ; 54(3): 219-23, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22801439

RESUMO

AIM: Cyclin D1 is an important cell cycle regulatory proteins, which is a functional target of Slug in the regulation of cell growth of prostate cancer cells. But the pathway of these two factors interacting with each other is unclear. METHODS: The infectde PCa Cells were treated with proteasome inhibitor MG-132. Expression level of Slug, HA-cyclin D1 and other protein was examined by Western blot. RESULTS: Increasing doses of adenovirus expressing human Slug were added to DU-145 cells separately, but there were no significantly difference on expressions of Slug and cyclin D1. We found that the protein expressions of HA-Cyclin D1 (wide-type) were all reduced through high expression of Slug, which is dose-dependent. However, there is no change for HA-Cyclin D1 (mutant) expression in PC-3 with pMIGW-Cyclin D1-HA T286A. The protein expression of HA-Cyclin D1 were all reduced three days after infection by adding adenovirus expressing human Slug to PC-3 carrying pMIGW-Cyclin D1-HA vector compared to negative control, which is dose-dependent. However, there is no change for HA-Cyclin D1 expression in PC-3 with pMIGW-Cyclin D1-HA treated by MG-132. CONCLUSION: We found that forced expression of Slug inhibited proliferation of prostate cancer cells through downregulation of cyclin D1 expression. And Slug regulates cyclin D1 expression by ubiquitin-proteasome pathway in PCa cells.


Assuntos
Ciclina D1/biossíntese , Regulação Neoplásica da Expressão Gênica , Neoplasias da Próstata/metabolismo , Fatores de Transcrição/biossíntese , Ciclo Celular , Linhagem Celular Tumoral , Proliferação de Células , Ciclina D1/genética , Relação Dose-Resposta a Droga , Regulação para Baixo , Endopeptidases/metabolismo , Humanos , Leupeptinas/farmacologia , Masculino , Mutação , RNA Mensageiro/metabolismo , Fatores de Transcrição da Família Snail , Ubiquitina/química , Proteases Específicas de Ubiquitina
8.
Phys Med Biol ; 56(14): 4557-77, 2011 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21725140

RESUMO

The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Encéfalo/patologia , Prova Pericial , Processamento de Imagem Assistida por Computador/métodos , Automação , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Humanos , Imageamento por Ressonância Magnética , Radioterapia de Intensidade Modulada , Fatores de Tempo , Tomografia Computadorizada por Raios X
9.
Med Phys ; 36(7): 2915-22, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19673190

RESUMO

Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12 x 0.12 x 0.12 cm3, with 17 x 17 x 17 microm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/ MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (approximately 8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only approximately 50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.


Assuntos
Osso e Ossos/efeitos da radiação , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Radiometria/métodos , Medula Óssea/efeitos da radiação , Osso e Ossos/citologia , Encéfalo/efeitos da radiação , Simulação por Computador , Feminino , Cabeça/efeitos da radiação , Humanos , Cristalino/efeitos da radiação , Masculino , Método de Monte Carlo , Pescoço/efeitos da radiação , Pelve/efeitos da radiação , Imagens de Fantasmas , Radiografia Torácica , Software
10.
J Surg Oncol ; 100(2): 106-10, 2009 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19475570

RESUMO

BACKGROUND AND OBJECTIVES: Accumulating epidemiological and molecular evidence suggests that inflammation is an important component in the etiology of PCa. Macrophage migration inhibitory factor (MIF) plays an important role in the pro- and anti-inflammatory response to infection. This study is aimed at investigating the potential association between MIF-173 G>C polymorphism, Gleason score, clinical stage, and prostate-specific antigen (PSA) value with respect to PCa incidence among the Han nationality in Southern China. METHODS: Genotyping was performed by using tetraprimer polymerase chain reaction (PCR) on 259 PCa patients and 301 cancer-free controls. RESULTS: We found that the MIF-173*C variant allele was significantly associated with an increased risk of PCa [adjusted odd ratio (OR) = 2.99, 95% confident interval (CI): 1.94-4.60] and higher Gleason scores from the PCa subjects (adjusted OR = 10.72, 95% CI: 5.35-21.49). In addition, we noted that the MIF -173*C variant allele was related to higher clinical stages and PSA values in PCa patients (adjusted OR = 15.68, 95% CI: 7.40-33.23; adjusted OR = 4.37, 95% CI: 2.41-7.92, respectively). CONCLUSION: Our data suggest that MIF-173 polymorphisms may be associated with a higher incidence of prostate cancer compared to controls, and appears to be associated with higher Gleason scores, higher clinical stages, and PSA values in those with prostate cancer.


Assuntos
Oxirredutases Intramoleculares/genética , Fatores Inibidores da Migração de Macrófagos/genética , Polimorfismo Genético , Neoplasias da Próstata/genética , Adulto , Idoso , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/sangue
11.
Med Phys ; 31(1): 142-53, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14761030

RESUMO

The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the dose distribution calculations is evaluated by direct comparisons with extensive sets of measured data in homogeneous and heterogeneous phantoms at different source-to-surface distances (SSDs) and gantry angles. We also verify the accuracy of the Monte Carlo module for monitor unit calculations in comparison with independent hand calculations for homogeneous water phantom at two different SSDs. All electron beams in the range 6-20 MeV are from a Siemens KD-2 linear accelerator. We used 10,000 or 50,000 histories/cm2 in our Monte Carlo calculations, which led to about 2.5% and 1% relative standard error of the mean of the calculated dose. The dose calculation time depends on the number of histories, the number of voxels used to map the patient anatomy, the field size, and the beam energy. The typical run time of the Monte Carlo calculations (10,000 histories/cm2) is 1.02 min on a 2.2 GHz Pentium 4 Xeon computer for a 9 MeV beam, 10 x 10 cm2 field size, incident on the phantom 15 x 15 x 10 cm3 consisting of 31 CT slices and voxels size of 3 x 3 x 3 mm3 (total of 486,720 voxels). We find good agreement (discrepancies smaller than 5%) for most of the tested dose distributions. We also find excellent agreement (discrepancies of 2.5% or less) for the monitor unit calculations relative to the independent manual calculations. The accuracy of monitor unit calculations does not depend on the SSD used, which allows the use of one virtual machine for each beam energy for all arbitrary SSDs. In some cases the test results are found to be sensitive to the voxel size applied such that bigger systematic errors (>5%) occur when large voxel sizes interfere with the extensions of heterogeneities or dose gradients because of differences between the experimental and calculated geometries. Therefore, user control over voxelization is important for high accuracy electron dose calculations.


Assuntos
Elétrons , Método de Monte Carlo , Imagens de Fantasmas , Radioterapia Conformacional/instrumentação , Software , Algoritmos , Aceleradores de Partículas/instrumentação , Espalhamento de Radiação
12.
Int J Radiat Oncol Biol Phys ; 51(4): 1167-75, 2001 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11704342

RESUMO

PURPOSE: To study the dose distributions at the interface due to the presence of a metal implant; to show the dose distributions in combined fields in the presence of hip prostheses; and to demonstrate the capabilities and limitations of a conventional system. METHODS AND MATERIALS: Perturbations in the dose distribution caused by a hip prosthesis can result in unacceptable dose inhomogeneities within the target volume and in regions where tissues interface with implant. The Monte Carlo technique and a conventional treatment planning system are used to calculate the dose distributions. RESULTS: Dose increases of 15% in tissue are seen at the interface between metal implant and tissue. Dose reductions of 5-25% or 10-45% are observed in the shadow of the hip prosthesis made of 0.5-3-cm-thick titanium or steel alloy respectively. We compared predicted dose distribution between the Monte Carlo simulation and a commercial treatment planning system (CADPLAN). We found that CADPLAN underestimated the attenuation of hip prostheses. This has led to overestimation of the target dose by 14% for a typical four-field box technique. CONCLUSIONS: An acceptable dose distribution can be achieved with a proper lateral beam weighting and compensation using an eight-field technique. The beam compensation may be applied to achieve an adequate target dose.


Assuntos
Prótese de Quadril , Neoplasias da Próstata/radioterapia , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Radiometria/métodos , Dosagem Radioterapêutica , Aço , Tomografia Computadorizada por Raios X
13.
Med Phys ; 28(3): 298-302, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11318309

RESUMO

According to the new AAPM TG-51 dosimetry protocol, reference dosimetry for electron beams is performed at depth of d(ref)=0.6R50-0.1 (cm) instead of d(max) recommended in TG-21. In clinical practice most electron beams are normalized at d(max). Therefore it becomes more important to get an accurate percentage-depth-dose (%dd) curve particularly for higher-energy electron beams in which the depth d(ref) is away from d(max). When ionization chambers are used in determining %dd curves the water-to-air stopping-power ratios and the fluence correction factors are required. The TG-51 recommends that the stopping-power ratios for realistic electron beams be used instead of the monoenergetic stopping-power ratios used in TG-21. This investigation aims to study the effects of those correction factors on the determination of %dd curves. We observed 1% deviations in the value of %dd at d(ref) for 15 and 18 MeV beams between a plane-parallel NACP and a cylindrical IC-10 chamber without considering the fluence correction factors P(fl). We explored a method to derive the fluence correction factors at any depth by using the existing fluence correction data at d(max) and tested its feasibility. We compared %dd curves measured by a diode detector and a NACP chamber with stopping-power ratios recommended by TG-51 and those recommended by TG-21. We found that for 15 and 18 MeV beams the difference in the values of %dd at d(ref) between using those two different stopping-power ratios is about 0.5%. Excellent agreement is found between %dd curves measured by the diode and by the NACP chamber when the stopping-power ratios recommended by TG-51 are used.


Assuntos
Elétrons , Radiometria , Relação Dose-Resposta à Radiação , Radioterapia Conformacional/métodos
14.
Med Phys ; 27(6): 1217-25, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10902550

RESUMO

We compare the results of absorbed dose determined at reference conditions according to the AAPM TG-21 dose calibration protocol and the new AAPM TG-51 protocol. The AAPM TG-21 protocol for absorbed dose calibration is based on ionization chambers having exposure calibration factors for 60Co gamma rays, N(x). The new AAPM TG-51 dosimetry protocol for absorbed dose calibration is based on ionization chambers having 60Co absorbed dose-to-water calibration factor, N60Co(D,w). This study shows that the dose changes are within 1% for a cobalt beam, 0.5% for photon energies of 6 and 18 MV, and 2%-3% for electron beams with energies of 6 to 20 MeV. The chamber primary calibration factors, Nx and N60Co(D,w), are traceable to the Canadian primary standards laboratory (NRCC). We also present estimated dose changes between the two protocols when calibration factors are traceable to NIST in the United States.


Assuntos
Radiometria/normas , Fenômenos Biofísicos , Biofísica , Protocolos Clínicos , Radioisótopos de Cobalto , Elétrons , Raios gama , Humanos , Fótons , Radiometria/instrumentação , Radiometria/métodos , Radioterapia de Alta Energia , Padrões de Referência , Sociedades Científicas , Estados Unidos , Água
15.
Med Phys ; 26(12): 2571-80, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10619241

RESUMO

We evaluated a commercial three-dimensional (3D) electron beam treatment planning system (CADPLAN V.2.7.9) using both experimentally measured and Monte Carlo calculated dose distributions to compare with those predicted by CADPLAN calculations. Tests were carried out at various field sizes and electron beam energies from 6 to 20 MeV. For a homogeneous water phantom the agreement between measured and CADPLAN calculated dose distributions is very good except at the phantom surface. CADPLAN is able to predict hot and cold spots caused by a simple 3D inhomogeneity but unable to predict dose distributions for a more complex geometry where CADPLAN underestimates dose changes caused by inhomogeneity. We discussed possible causes for the inaccuracy in the CADPLAN dose calculations. In addition, we have tested CADPLAN treatment monitor unit and electron cut-out factor calculations and found that CADPLAN predictions generally agree with manual calculations.


Assuntos
Radioterapia Assistida por Computador , Algoritmos , Relação Dose-Resposta à Radiação , Elétrons , Estudos de Avaliação como Assunto , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Costelas/efeitos da radiação , Software , Coluna Vertebral/efeitos da radiação , Traqueia/efeitos da radiação
16.
Med Phys ; 25(8): 1453-7, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9725133

RESUMO

This paper describes a method to measure the product of Prepl Pwall correction factors for ionization chambers and presents our measured values of Prepl Pwall for Markus plane-parallel chambers in electron beams. It is shown that the measured values of Prepl Pwall can be fitted to an equation, Prepl Pwall = c1 + c2 R50 + c3 (R50)2, for Markus chambers at the new reference depth for electron beams (6 MeV < or = nominal energy E < or = 20 MeV). We also present our measured values of Prepl Pwall for NACP and Markus chambers in a water phantom irradiated in a 60Co beam.


Assuntos
Radioisótopos de Cobalto/uso terapêutico , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Elétrons , Modelos Teóricos , Dosagem Radioterapêutica , Água
17.
Med Phys ; 25(2): 251-3, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9507489

RESUMO

We have measured the peak scatter factor (PSF) for electron beams which in analogy to photon beams is defined as the ratio of the absorbed dose to water at the depth of dose maximum in a water phantom to the absorbed dose in free air at the same location for a given incident beam. In this study we have measured the PSFs as a function of the incident electron beam energy and field size. We have used both an RK ionization chamber and a silicon diode as radiation detectors. After applying the water/air stopping power ratio and fluence correction factors to the ionization chamber readings, the values of measured PSFs by using two different detectors are in a good agreement. The results show that the value of PSF increases with the increase of the field size and decreases with the increase of the beam energy. The range of the variation with field size between 2 x 2 and 10 x 10 cm2 is 1.24-1.42, 1.15-1.30, 1.15-1.17 for 6, 11, and 20 MeV beams, respectively.


Assuntos
Elétrons/uso terapêutico , Radioterapia de Alta Energia , Algoritmos , Fenômenos Biofísicos , Biofísica , Humanos , Neoplasias/radioterapia , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Espalhamento de Radiação , Água
18.
Phys Med Biol ; 42(8): 1505-14, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9279902

RESUMO

This paper presents a practical approach to clinical dosimetry for electron beams at extended source-to-surface distance (SSD). Characteristics of electron beams from a Siemens MD-2 accelerator are presented at a nominal SSD of 100 cm and an extended SSD of 115 cm. Relative output factors are measured at both 100 and 115 cm SSDs for a range of square field sizes for each beam energy. The change of output with SSD does not follow the inverse square law, if the nominal SSD is used. This deviation is larger for lower beam energy and smaller field sizes. An effective SSD, SSDeff, has been determined at dmax for each beam energy as a function of field size. A comprehensive approach to treatment time calculations is proposed.


Assuntos
Elétrons/uso terapêutico , Aceleradores de Partículas , Imagens de Fantasmas , Modelos Teóricos , Dosagem Radioterapêutica
19.
Med Dosim ; 22(2): 135-7, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9243468

RESUMO

In order to safely treat a 23 weeks pregnant woman for supradiapharagmatic Hodgkin's disease, without compromising the fetus, a custom shielding table was constructed and extensive phantom measurements were performed. For 10 MV photons, the optimal shielding combination was found to consist of a 5 cm thick lead sheet placed onto a 1.25 cm aluminum supporting plate. The structure was placed directly above the phantom, over the region corresponding to the woman's abdomen, without any intervening air gap. By this means the dose to the fetus from machine leakage and collimator scatter was eliminated; the only remaining dose was due to in-phantom scatter. The woman was treated using a mantle field to a dose of 35 Gy in 20 fractions. The accumulated dose to the woman's uterine fundus and to her pubis were monitored with theroluminescent dosimeters. After completion of mantle therapy the doses to the fundus and pubis were 10 and 3 cGy, respectively. The fetal exposure was thus limited to below 10 cGy, within the zone of fetal tolerance. A normal infant was delivered at term.


Assuntos
Feto/efeitos da radiação , Doença de Hodgkin/radioterapia , Complicações Neoplásicas na Gravidez/radioterapia , Feminino , Humanos , Imagens de Fantasmas , Gravidez , Proteção Radiológica , Dosagem Radioterapêutica , Dosimetria Termoluminescente
20.
Med Phys ; 24(2): 161-76, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9048356

RESUMO

In radiation dosimetry protocols, plastic is allowed as a phantom material for the determination of absorbed dose to water in electron beams. The electron fluence correction factor is needed in conversion of dose measured in plastic to dose in water. There are large discrepancies among recommended values as well as measured values of electron fluence correction factors when polystyrene is used as a phantom material. Using the Monte Carlo technique, we have calculated electron fluence correction factors for incident clinical beam energies between 5 and 50 MeV as a function of depth for clear polystyrene, white polystyrene and PMMA phantom materials and compared the results with those recommended in protocols as well as experimental values from published data. In the Monte Carlo calculations, clinical beams are simulated using the EGS4 user-code BEAM for a variety of medical accelerators. The study shows that our calculated fluence correction factor, phi pw, is a function of depth and incident beam energy Eo with little dependence on other aspects of beam quality. However the phi pw values at dmax are indirectly influenced by the beam quality since they vary with depth and dmax also varies with the beam quality. Calculated phi pw values at dmax are in a range of 1.005-1.045 for a clear polystyrene phantom, 1.005-1.038 for a white polystyrene phantom and 0.996-1.016 for a PMMA phantom. Our values of phi pw are about 1-2% higher than those determined according to the AAPM TG-25 protocol at dmax for clear or white polystyrene. Our calculated values of phi pw also explain some of the variations of measured data because of its depth dependence. A simple formula is derived which gives the electron fluence correction factor phi pw as a function of R50 at dmax or at the depth of 0.6R50-0.1 for any clinical electron beam with energy between 5 and 25 MeV for three plastics: clear polystyrene, white polystyrene and PMMA. The study also makes a careful distinction between phi pw and the corresponding IAEA Code of Practice quantity, hm.


Assuntos
Elétrons , Modelos Biológicos , Imagens de Fantasmas , Dosagem Radioterapêutica , Fenômenos Biofísicos , Biofísica , Método de Monte Carlo , Tecnologia Radiológica , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...