Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 11(12): 1221-3, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9373300

RESUMO

A system was developed to determine the potential role of infrared imaging as a tool for localizing anatomic structures and assessing tissue viability during laparoscopic surgical procedures. A camera system sensitive to emitted energy in the midinfrared range (3-5 micron) was incorporated into a two-channel visible laparoscope. Laparoscopic cholecystectomy, dissection of the ureter, and assessment of bowel perfusion were performed in a porcine model with the aid of this infrared imaging system. Inexperienced laparoscopists were asked to localize and differentiate structures before dissection using the visible system and then using the infrared system. Assessment of bowel perfusion was also conducted using each system. Infrared imaging proved to be useful in differentiating between blood vessels and other anatomic structures. Differentiation of the cystic duct and arteries and transperitoneal localization of the ureter were successful in all instances using the infrared system when use of the visible system had failed. This system also permitted assessment of bowel perfusion during laparoscopic occlusion of mesenteric vessels. These initial studies demonstrate that infrared imaging may improve the differentiation and localization of anatomic structures and allow assessment of physiologic parameters such as perfusion not previously attainable with visible laparoscopic techniques. It may thus potentially be a powerful adjunct to laparoscopic surgery.


Assuntos
Laparoscopia/métodos , Termografia/métodos , Animais , Artérias/anatomia & histologia , Colecistectomia Laparoscópica/métodos , Ducto Cístico/anatomia & histologia , Modelos Animais de Doenças , Dissecação , Desenho de Equipamento , Vesícula Biliar/irrigação sanguínea , Raios Infravermelhos , Intestinos/irrigação sanguínea , Laparoscópios , Luz , Artérias Mesentéricas/anatomia & histologia , Oclusão Vascular Mesentérica/fisiopatologia , Veias Mesentéricas/anatomia & histologia , Monitorização Intraoperatória , Peritônio/anatomia & histologia , Circulação Esplâncnica , Suínos , Termografia/instrumentação , Sobrevivência de Tecidos , Ureter/cirurgia
2.
Arch Ophthalmol ; 115(5): 673-5, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9152140

RESUMO

A 13-year-old Hispanic boy suffered a perforating injury to his right eye from a BB. The clinical examination and computed tomographic scan revealed questionable light perception and a dense foreign body, consistent with a BB, situated behind the globe. A vitrectomy was performed that was unsuccessful. Six months later the eye was enucleated, and the BB was found to be within the optic nerve sheath. Foreign bodies within the optic nerve are uncommon. The foreign body in this case, a BB, entered the optic nerve through the nerve head after traversing the globe. The histopathologic findings in this unusual case are presented herein.


Assuntos
Corpos Estranhos no Olho/etiologia , Ferimentos Oculares Penetrantes/etiologia , Traumatismos do Nervo Óptico , Ferimentos por Arma de Fogo/etiologia , Adolescente , Cegueira/etiologia , Enucleação Ocular , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Humanos , Masculino , Bainha de Mielina , Nervo Óptico/patologia , Nervo Óptico/cirurgia , Tomografia Computadorizada por Raios X , Ferimentos por Arma de Fogo/diagnóstico , Ferimentos por Arma de Fogo/cirurgia