Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nutrients ; 13(6)2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34205676

RESUMO

Body water turnover is a marker of hydration status for measuring total fluid gains and losses over a 24-h period. It can be particularly useful in predicting (and hence, managing) fluid loss in individuals to prevent potential physical, physiological and cognitive declines associated with hypohydration. There is currently limited research investigating the interrelationship of fluid balance, dietary intake and activity level when considering body water turnover. Therefore, this study investigates whether dietary composition and energy expenditure influences body water turnover. In our methodology, thirty-eight males (19 sedentary and 19 physically active) had their total body water and water turnover measured via the isotopic tracer deuterium oxide. Simultaneous tracking of dietary intake (food and fluid) is carried out via dietary recall, and energy expenditure is estimated via accelerometery. Our results show that active participants display a higher energy expenditure, water intake, carbohydrate intake and fibre intake; however, there is no difference in sodium or alcohol intake between the two groups. Relative water turnover in the active group is significantly greater than the sedentary group (Mean Difference (MD) [95% CI] = 17.55 g·kg-1·day-1 [10.90, 24.19]; p = < 0.001; g[95% CI] = 1.70 [0.98, 2.48]). A penalised linear regression provides evidence that the fibre intake (p = 0.033), water intake (p = 0.008), and activity level (p = 0.063) predict participants' relative body water turnover (R2= 0.585). In conclusion, water turnover is faster in individuals undertaking regular exercise than in their sedentary counterparts, and is, in part, explained by the intake of water from fluid and high-moisture content foods. The nutrient analysis of the participant diets indicates that increased dietary fibre intake is also positively associated with water turnover rates. The water loss between groups also contributes to the differences observed in water turnover; this is partly related to differences in sweat output during increased energy expenditure from physical activity.


Assuntos
Água Corporal/metabolismo , Dieta , Exercício Físico , Comportamento Sedentário , Adulto , Fibras na Dieta/administração & dosagem , Ingestão de Líquidos , Ingestão de Alimentos , Ingestão de Energia , Metabolismo Energético , Humanos , Masculino , Equilíbrio Hidroeletrolítico
2.
PLoS One ; 10(2): e0117907, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25659140

RESUMO

PURPOSE: Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. METHODS: Mean skin temperature ([Formula: see text]) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). [Formula: see text] was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). RESULTS: Bland-Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of [Formula: see text] found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. CONCLUSIONS: These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring [Formula: see text] in the presence of, or following, metabolic and environmental induced heat stress.


Assuntos
Exercício Físico/fisiologia , Temperatura Alta , Raios Infravermelhos , Temperatura Cutânea/fisiologia , Termômetros , Adulto , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA