Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13486, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38866902

RESUMO

Monolayer materials typically display intriguing temperature-dependent dielectric and optical properties, which are crucial for improving the structure and functionality of associated devices. Due to its unique photoelectric capabilities, monolayer WSe2 has recently received a lot of attention in the fields of atomically thin electronics and optoelectronics. In this work, we focus on the evolution of the temperature-dependent dielectric function (ε = ε1 + i ε2) of monolayer WSe2 over energies from 0.74 to 6.40 eV and temperatures from 40 to 350 K. We analyze the second derivatives of ε with respect to energy to accurately locate the critical points (CP). The dependence of the observed CP energies on temperature is consistent with the alternative domination of the declining exciton binding energy as the temperature increases.

2.
Biosens Bioelectron ; 168: 112525, 2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-32858415

RESUMO

Early diagnosis of acute myocardial infarction (AMI) significantly reduce the mortality rate and can be achieved via high-sensitive detection of AMI specific cardiac troponin I (cTnI) biomarker. Here, we present normal-incident type solution-immersed silicon (NI-SIS) ellipsometric biosensor, designed for ultra-high sensitive, high-throughput, label-free detection of the target protein. The NI-SIS sensors are equipped with a specially designed prism that maintains the angle of incidence close to the Brewster angle during operation, which significantly reduces SIS noise signals induced by the refractive index fluctuations of the surrounding medium, improves the signal-to-noise ratio, in-results lowers the detection limit. We applied NI-SIS biosensor for ultra-sensitive detection of cTnI biomarkers in human serum. The optimized sensor chip fabrication and detection operation procedures are proposed. The wide linear concentration ranges of fg/mL to ng/mL is achieved with the detection limit of 22.0 fg/mL of cTnI. The analytical correlation was assessed by linear regression analysis with the results of the Pathfast reference system. These impressive biosensing capabilities of NI-SIS technology have huge potentials for accurate detection of target species in different application areas, such as diagnosis, drug discovery, and food contaminations.


Assuntos
Técnicas Biossensoriais , Infarto do Miocárdio , Biomarcadores , Humanos , Incidência , Infarto do Miocárdio/diagnóstico , Silício , Troponina I
3.
Biointerphases ; 12(1): 01A402, 2017 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-28231713

RESUMO

Highly sensitive solution immersed silicon (SIS) biosensors were developed for detection of hepatitis B virus (HBV) infection in the early stage. The ultrasensitivity for overlayer thickness at the nonreflecting condition for the p-polarized wave is the basis of SIS sensing technology. The change in thickness due to biomolecular interactions and change in refractive index of the surrounding buffer medium were assessed simultaneously using two separate ellipsometric parameters (Ψ and Δ), respectively, from a single sensing spot. A direct antigen-antibody affinity assay was used to detect and quantify hepatitis B surface antigen (HBsAg), which is the early stage biomarker for HBV infection. The detection limit of 10 pg/ml was achieved for HBsAg in the human blood serum, which is comparable with the results of enzyme-linked immunosorbent assay and other hybrid assays. The SIS sensor's response time was less than 10 min. The SIS sensors exhibit excellent stability and high signal-to-noise ratio, and are cost-effective, which makes them a suitable candidate for point-of-care applications.


Assuntos
Técnicas Biossensoriais/métodos , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Análise Custo-Benefício , Humanos , Silício/metabolismo , Fatores de Tempo
4.
Biosens Bioelectron ; 87: 242-248, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27567249

RESUMO

Acute myocardial infarction (MI) is the leading cause of high mortality and morbidity rate worldwide, early and accurate diagnosis can increase the chances of survival. In this work, we report a simple, ultrasensitive, label-free, and high-throughput solution immersed silicon (SIS) immunosensor based on non-reflection condition (NRC) for p-polarized wave for early diagnosis of MI. SIS sensor chips are just a thin dielectric polymer layer on the silicon surface, which can be functionalized for specific application. At NRC, SIS sensors are extremely sensitive to the growing thickness of a bio-layer on the sensor surface while independent of refractive index change of the surrounding medium. Therefore, SIS signal is free from thermal noise, unlike surface plasmon resonance based sensor. Also, there is no need of reference signal which facilitates fast and accurate interaction measurement. Here, SIS technology is applied to tackle two issues in MI diagnosis: high sensitivity with the direct assay and the ability to measure in human serum. Myoglobin, creatine kinase-MB, and cardiac troponin I (cTnI) proteins were used as the MI biomarkers. We were able to measure over a broad concentration range with the detection limit of 5 and 10pg/ml for cTnI in PBS and blood serum, respectively. The response time is about 5min. This novel technique is a suitable candidate for cost effective point-of-care application.


Assuntos
Técnicas Biossensoriais/instrumentação , Infarto do Miocárdio/sangue , Troponina I/sangue , Creatina Quinase Forma MB/sangue , Desenho de Equipamento , Humanos , Dispositivos Lab-On-A-Chip , Infarto do Miocárdio/diagnóstico , Mioglobina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...