Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 11(1)2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33450942

RESUMO

To evaluate the effect of radiation dose reduction on image quality and diagnostic confidence in contrast-enhanced whole-body computed tomography (WBCT) staging. We randomly selected March 2016 for retrospective inclusion of 18 consecutive patients (14 female, 60 ± 15 years) with clinically indicated WBCT staging on the same 3rd generation dual-source CT. Using low-dose simulations, we created data sets with 100, 80, 60, 40, and 20% of the original radiation dose. Each set was reconstructed using filtered back projection (FBP) and Advanced Modeled Iterative Reconstruction (ADMIRE®, Siemens Healthineers, Forchheim, Germany) strength 1-5, resulting in 540 datasets total. ADMIRE 2 was the reference standard for intraindividual comparison. The effective radiation dose was calculated using commercially available software. For comparison of objective image quality, noise assessments of subcutaneous adipose tissue regions were performed automatically using the software. Three radiologists blinded to the study evaluated image quality and diagnostic confidence independently on an equidistant 5-point Likert scale (1 = poor to 5 = excellent). At 100%, the effective radiation dose in our population was 13.3 ± 9.1 mSv. At 20% radiation dose, it was possible to obtain comparably low noise levels when using ADMIRE 5 (p = 1.000, r = 0.29). We identified ADMIRE 3 at 40% radiation dose (5.3 ± 3.6 mSv) as the lowest achievable radiation dose with image quality and diagnostic confidence equal to our reference standard (p = 1.000, r > 0.4). The inter-rater agreement for this result was almost perfect (ICC ≥ 0.958, 95% CI 0.909-0.983). On a 3rd generation scanner, it is feasible to maintain good subjective image quality, diagnostic confidence, and image noise in single-energy WBCT staging at dose levels as low as 40% of the original dose (5.3 ± 3.6 mSv), when using ADMIRE 3.

2.
BMC Med Imaging ; 19(1): 4, 2019 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-30635023

RESUMO

BACKGROUND: To evaluate a reduced range CT protocol in patients with suspected acute appendicitis as compared to standard abdominal CT regarding diagnostic performance, effective radiation dose and organ doses. METHODS: In this study, we retrospectively included 90 patients (43 female, mean age 56.7 ± 17 years) with suspected acute appendicitis who underwent CT of abdomen and pelvis. From those CTs, we reconstructed images with a reduced scan range from L1 to the the pubic symphysis. Full range and reduced range datasets were assessed by two radiologists for i) coverage of the Appendix, ii) presence/absence of appendicitis and iii) presence of differential diagnoses. Furthermore, effective radiation doses as well as organ doses were calculated using a commercially available dose management platform (Radimetrics, Bayer HealthCare). RESULTS: The Appendix was covered by the reduced range CT in all cases. In 66 patients CT confirmed the presence of appendicitis. In 14 patients, other relevant differential diagnoses were identified by CT, whereas in 10 patients no relevant findings were detected. Both readers identified all patients with appendicitis on both full and reduced range CT. For reduced range CT, total effective dose was 39% lower than for full range CT (reduced range: 4.5 [1.9-11.2] vs. full range: 7.4 [3.3-18.8] mSv; p ≤ 0.001). Notably, a remarkable reduction of organ dose in the female breasts by 97% (0.1 [0.1-0.6] vs. 3.8 [0.5-18.8] mSv; p ≤ 0.001) and in the testicles in males by 81% (3.4 [0.7-32.7] vs. 17.6 [5.4-52.9] mSv; p ≤ 0.001) was observed for reduced range CT compared to full range CT. CONCLUSIONS: In patients with suspected acute appendicitis, reduced range abdominopelvic CT results in a comparable diagnostic performance with a remarkable reduction of total effective radiation dose and organ doses (especially breast dose in female and testicle dose in male patients) as compared to full range CT.


Assuntos
Abdome/diagnóstico por imagem , Apendicite/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...