Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Feline Med Surg ; 15(2): 142-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23076596

RESUMO

The thymidine kinases are enzymes that convert deoxythymidine to deoxythymidine monophosphate and have a function in DNA synthesis. Rapidly proliferating cells will have higher levels of thymidine kinase. Serum thymidine kinase activity (sTK) is a useful tumour marker in humans and dogs, with utility as a prognostic indicator in lymphoma. In the current study serum samples were collected from 49 clinically healthy cats, 33 with lymphoma, 55 with inflammatory disease and 34 with non-haematopoietic neoplasia (NHPN). sTK was measured using a radioenzyme assay and a reference interval (1.96 × SD) was established from the clinically healthy cats (<5.5 U/l). Mean sTK activity for healthy cats was 2.2 U/l (range 0.8-8.4, ± SD 1.7). Mean sTK activity for cats with lymphoma was 17.5 U/l (range 1.0-100.0 SD ± 27.4). Mean sTK activity for cats with NHPN was 4.2 U/l (range 1.0-45.0, SD ± 8.6). Mean sTK activity for the inflammatory group was 3.4 U/l (range 1.0-19.6, SD 3.9). Cats with lymphoma had significantly higher sTK activity than healthy cats or cats with inflammatory disease (P <0.0001) and cats with NHPN (P <0.0002). sTK activity is a potentially useful biomarker for feline lymphoma and further study is required to assess its utility as a prognostic indicator.


Assuntos
Doenças do Gato/diagnóstico , Linfoma/veterinária , Timidina Quinase/metabolismo , Animais , Biomarcadores Tumorais , Doenças do Gato/enzimologia , Gatos , Feminino , Linfoma/sangue , Masculino , Sensibilidade e Especificidade , Timidina Quinase/sangue
2.
J Feline Med Surg ; 13(2): 152-4, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21186131

RESUMO

Measuring urine specific gravity (USG) is an important component of urine analysis as it evaluates renal concentrating capability. The objective of this study was to quantify the difference in USG values between a hand-held optical analogue refractometer and a cat-specific digital instrument. Urine samples from 55 cats were assessed. There was a statistically significant difference between these two refractometers (P<0.001), with the optical refractometer (mean USG=1.031) consistently reading higher than the digital refractometer (mean USG=1.027). Results for a random subset of the samples (n=10) were compared with urine osmolality and both the optical and digital instruments demonstrated excellent correlation. While an accurate USG reading is important, it is unlikely that the statistical significance between the two instruments is clinically significant and, therefore, unlikely to result in a change in patient evaluation or treatment plans. While both the digital and optimal refractometers are highly correlated to the urine osmolality, making both devices valid for assessment of USG in clinical practice, this digital device is easier to read and eliminates the variability of subjective interpretation.


Assuntos
Gatos/urina , Refratometria/veterinária , Animais , Concentração Osmolar , Refratometria/instrumentação , Reprodutibilidade dos Testes , Gravidade Específica , Urina/química
3.
J Feline Med Surg ; 12(8): 643-53, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20655494

RESUMO

All serum protein electrophoresis (SPE) results obtained between 2002 and 2009 from clinical cases presented to the University of Bristol Feline Centre were examined retrospectively. One hundred and fifty-five results met the inclusion criteria. Signalment and final diagnoses were obtained from the case records. Clinical cases were classified as having normal or abnormal SPE results by comparison to reference intervals for SPE created using 77 clinically normal cats. Abnormal results were then further divided according to the specific SPE abnormality. Cases were also categorised, according to the final diagnosis, using the DAMNITV classification system. Of the 155 cases, 136 (87.7%) had abnormal SPE results, most commonly due to a polyclonal increase in gamma globulins. A monoclonal gammopathy occurred in four cats; one with feline infectious peritonitis (FIP), one with lymphoma and two cases of splenic plasmacytoma (one suspected, one confirmed). The most common DAMNITV classification associated with SPE abnormalities was infectious/inflammatory disease (80/136; 58.8%), including 39 cats diagnosed with FIP.


Assuntos
Eletroforese das Proteínas Sanguíneas/veterinária , Proteínas Sanguíneas/análise , Doenças do Gato/sangue , Peritonite Infecciosa Felina/sangue , Animais , Doenças do Gato/diagnóstico , Gatos , Peritonite Infecciosa Felina/diagnóstico , Feminino , Linfoma/sangue , Linfoma/diagnóstico , Linfoma/veterinária , Masculino , Paraproteinemias/veterinária , Plasmocitoma/sangue , Plasmocitoma/diagnóstico , Plasmocitoma/veterinária , Valores de Referência , Estudos Retrospectivos , Baço/patologia , gama-Globulinas/metabolismo
4.
Vet Clin Pathol ; 37(1): 66-72, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18366547

RESUMO

BACKGROUND: Heparinized syringes are commonly used with point-of-care analyzers (eg, i-STAT) to measure ionized calcium (iCa(2+)); however there is little information about the validity of their use in canine patients. OBJECTIVE: To examine the suitability of prefilled (40 IU heparin/mL) and self-filled (150 IU heparin/mL) heparinized syringes for iCa(2+) measurements using the i-STAT analyzer. METHODS: Forty-seven blood samples were collected from 41 canine patients. Two milliliters of blood were collected into a 2-mL nonanticoagulated (NA) syringe, a commercially available preheparinized (PH) syringe (dry calcium-balanced lithium heparin, 40 IU/mL), and a 2-mL self-filled heparinized (SH) syringe (liquid sodium heparin, 150 IU/mL). iCa(2+) was measured in the sample using the i-STAT analyzer and a wet-reagent analyzer (KoneLab 30i) used as the reference instrument. Data were analyzed using paired t-tests, Pearson correlation coefficient, and Bland-Altman difference plots. RESULTS: There was no significant difference between the results obtained from NA and PH syringes using the i-STAT analyzer, and the correlation was excellent (r =.97). The i-STAT values from the SH syringes (mean, 1.07 mmol/L) were significantly lower (P<.001) than those from the NA syringes (mean, 1.38 mmol/L). iCa(2+) was significantly higher with the i-STAT analyzer than with the KoneLab analyzer for both the PH (mean i-STAT, 1.38 mmol/L vs mean KoneLab, 1.30 mmol/L) and SH (mean i-STAT, 1.07 mmol/L vs mean KoneLab, 1.03 mmol/L) samples. CONCLUSIONS: Blood samples collected in the PH syringes used in this study can be used interchangeably with those collected in NA syringes for measuring iCa(2+) using the i-STAT analyzer. SH syringes with high-concentration heparin products (5000 IU/mL) are unsuitable for measuring iCa(2+) because they cause clinically significant underestimations. Although there was good correlation between the i-STAT and KoneLab analyzers, the results should be interpreted using analyzer-specific reference intervals.


Assuntos
Análise Química do Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , Cálcio/sangue , Cães/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Seringas , Animais , Anticoagulantes , Análise Química do Sangue/instrumentação , Heparina
5.
Vet Clin Pathol ; 31(4): 162-6, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12447778

RESUMO

BACKGROUND: Pleural and peritoneal effusion is a common clinical finding in feline practice. Determination of fluid albumin (ALB) and globulin (GLOB) concentrations in addition to total protein (TP) concentration can be helpful in diagnosing or ruling out certain diseases in cats, especially feline infectious peritonitis (FIP). OBJECTIVE: The objective of this study was to compare effusion TP, ALB, and GLOB results obtained by a refractometer and a bench-top dry chemistry analyzer with those results obtained by a reference method. METHODS: Twenty-six pleural and 14 peritoneal effusion samples were analyzed from 40 cats with various diseases. TP and ALB concentrations were determined by a reference automated wet chemistry analyzer (Kone Specific, Kone Instruments, Espoo, Finland), a bench-top dry chemistry analyzer (Vettest 8008, IDEXX Laboratories Ltd, Chalfont St Peter, UK), and a refractometer (Atago SPR-T2, Atago Co, Tokyo, Japan). GLOB, albumin to globulin (A/G) ratio, and globulins as a percentage of total proteins (GLOB%) were calculated. Results were analyzed by paired t tests, difference plots, and Deming s regression analysis. RESULTS: Correlation coefficients (r) for TP with Vettest versus Kone and refractometer versus Kone methods were.97 and.94, respectively. GLOB and GLOB% values were significantly higher and A/G ratios were significantly lower with Vettest versus Kone methods. Correlation coefficients for ALB, GLOB, GLOB% and A/G ratio with Vettest versus Kone methods were.86,.93,.82, and.73, respectively. Although correlation with other methods was good, the refractometer underestimated TP concentrations in 3 samples. CONCLUSIONS: The refractometer is an acceptable method for determination of TP concentration in feline effusions. The Vettest 8008 also is an acceptable method for the determination of TP and ALB concentrations, however, calculated A/G ratios obtained with the Vettest are unacceptable.


Assuntos
Líquido Ascítico/química , Líquido Ascítico/veterinária , Doenças do Gato/diagnóstico , Colorimetria/veterinária , Derrame Pleural/química , Derrame Pleural/veterinária , Proteínas/análise , Refratometria/veterinária , Albuminas/análise , Animais , Gatos , Feminino , Globulinas/análise , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...