1.
Artigo em Inglês | MEDLINE | ID: mdl-31338376

RESUMO

To overcome the ill-posed nature of the inverse problem of electrocardiography (ECG) and stabilize the solutions, regularization is used. Despite several studies on noise, effect of prefiltering of ECG signals on the regularized inverse solutions has not been explored. We used Bayesian estimation for solving the inverse ECG problem with and without applying various prefiltering methods, and evaluated our results using experimental data that came from a Langendorff-perfused pig heart suspended in a human-shaped torso-tank. Epicardial electrograms were recorded during RV pacing using a 108-electrode array, simultaneously with ECGs from 128 electrodes embedded in the tank surface. Leave-one-beat-out protocol was used to obtain the prior probability density function (pdf) of electro-grams and noise statistics. Noise pdf was assumed to be zero mean-Gaussian, with covariance assumptions: a) independent and identically distributed (noi-iid), b) correlated (noi-corr). Reconstructed electrograms and activation times were compared to those directly recorded by the sock for 3 beats selected from the recording. Noi-corr is superior to noi-iid when the training set is a good match to data, but for applications requiring activation time derivation, careful selection of preprocessing methods, in particular to adequately remove high-frequency noise, and an appropriate noise model is needed.

2.
Artigo em Inglês | MEDLINE | ID: mdl-30899762

RESUMO

The inverse problem of electrocardiography is ill-posed. Errors in the model such as signal noise can impact the accuracy of reconstructed cardiac electrical activity. It is currently not known how sensitive the inverse problem is to signal processing techniques. To evaluate this, experimental data from a Langendorff-perfused pig heart (n=1) suspended in a human-shaped torso-tank was used. Different signal processing methods were applied to torso potentials recorded from 128 electrodes embedded in the tank surface. Processing methods were divided into three categories i) high-frequency noise removal ii) baseline drift removal and iii) signal averaging, culminating in n=72 different signal sets. For each signal set, the inverse problem was solved and reconstructed signals were compared to those directly recorded by the sock around the heart. ECG signal processing methods had a dramatic effect on reconstruction accuracy. In particular, removal of baseline drift significantly impacts the magnitude of reconstructed electrograms, while the presence of high-frequency noise impacts the activation time derived from these signals (p<0.05).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA