Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Rheumatol ; 42(12): 3275-3281, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37553551

RESUMO

The objective of this pilot study was to assess the impact of a salivary gland ultrasound (SGUS) atlas for scoring parenchymal changes in Sjögren's syndrome by assessing the reliability of the scoring system (0-3), without and with the use of the SGUS atlas. Ten participants with varying experience in SGUS contributed to the reliability exercise. Thirty SGUS images of the submandibular and parotid gland with abnormalities ranging from 0 to 3 were scored using the written definitions of the OMERACT SGUS scoring system and using the SGUS atlas based on the OMERACT scoring system. For intra-reader reliability, two rounds were performed without and with the atlas-in the 2nd round the 30 images were rearranged in random order by a physician not included in the scoring. Inter-reader reliability was also determined in both rounds. Without using the atlas, the SGUS OMERACT scoring system showed fair inter-reader reliability in round 1 (mean kappa 0.36; range 0.06-0.69) and moderate intra-reader reliability (mean kappa 0.55; range 0.28-0.81). With the atlas, inter-reader reliability improved in round 1 to moderate (mean kappa 0.52; range 0.31-0.77) and intra-reader reliability to good (mean kappa 0.69; range 0.46-0.86). Higher intra-reader reliability was noted in participants with previous SGUS experience. The SGUS atlas increased both intra- and inter-reader reliability for scoring gland pathology in participants with varying SGUS experience suggesting a possible future role in clinical practice and trials. Key Points • Ultrasonography can detect parenchymal changes in salivary glands in patients with Sjögren's disease. • An ultrasound atlas may improve reliability of scoring parenchymal changes in salivary glands.


Assuntos
Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia/métodos
2.
Life (Basel) ; 13(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36983848

RESUMO

Giant cell arteritis (GCA) is an ophthalmological emergency that can be difficult to diagnose and prompt treatment is vital. We investigated the sequential diagnostic value for patients with suspected GCA using three biochemical measures as they arrive to the clinician: first, platelet count, then C-reactive protein (CRP), and lastly, erythrocyte sedimentation rate (ESR). This retrospective cross-sectional study of consecutive patients with suspected GCA investigated platelet count, CRP, and ESR using diagnostic test accuracy statistics and odds ratios (ORs) in a sequential fashion. The diagnosis was established by experts at follow-up, considering clinical findings and tests including temporal artery biopsy. A total of 94 patients were included, of which 37 (40%) were diagnosed with GCA. Compared with those without GCA, patients with GCA had a higher platelet count (p < 0.001), CRP (p < 0.001), and ESR (p < 0.001). Platelet count demonstrated a low sensitivity (38%) and high specificity (88%); CRP, a high sensitivity (86%) and low specificity (56%); routine ESR, a high sensitivity (89%) and low specificity (47%); and age-adjusted ESR, a moderate sensitivity (65%) and moderate specificity (65%). Sequential analysis revealed that ESR did not provide additional value in evaluating risk of GCA. Initial biochemical evaluation can be based on platelet count and CRP, without waiting for ESR, which allows faster initial decision-making in GCA.

3.
Neuroophthalmology ; 46(6): 383-389, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36544584

RESUMO

With normal retinal blood flow, cross-sectional optical coherence tomography (OCT) of retinal vessels shows a structured intravascular reflectivity profile, resembling a 'figure-of-8'. Altered profiles have been reported in vascular occlusive and haematological diseases. Giant cell arteritis (GCA) can cause visual loss, usually due to anterior ischaemic optic neuropathy (AION) or retinal artery occlusion. Our aim was to extend the assessment of OCT vascular profiles to patients with suspected GCA and to determine if any abnormalities were related to GCA per se or to ischaemic ocular conditions. This nested retrospective study included 61 eyes of 31 patients (13 with GCA). Six eyes had arteritic and seven eyes non-arteritic AION, three eyes had non-arteritic retinal artery occlusion, 11 eyes had other ocular conditions and 34 were unaffected control eyes. For each eye the appearance of structured intravascular profiles on peripapillary OCT was graded as present, partial, absent or uncertain. Non-presence of structured intravascular profiles was more frequent in AION and retinal artery occlusion than in other ocular conditions or unaffected eyes (Fisher's test, p = .0047). Based on follow-up of 25 eyes, reflectivity profiles normalised in three out of four eyes after 85 (35-245) days. Vessel profiles were not associated with GCA (p = .32) and were similar in arteritic and non-arteritic AION (p = .66). In conclusion, absence of structured intravascular reflectivity profiles may be a marker of acute ischaemia in the anterior optic nerve or inner retina. However, it did not seem specific for GCA. The prognostic value warrants further studies.

4.
RMD Open ; 7(2)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33879581

RESUMO

AIM: To describe salivary gland involvement in patients suspected of Sjögren's syndrome (SS) using the OMERACT Ultrasound Scoring System for SS. Next, using different ultrasound cut-offs, to assess the performance of the scoring system for diagnosis and fulfilment of 2016 ACR/EULAR SS classification criteria. METHODS: All patients referred to our department with a suspicion of SS in a 12-month period were included. All underwent grey-scale ultrasound of the parotid and submandibular glands prior to clinical examination, Schirmer's test, unstimulated salivary flow, blood samples including autoantibody analysis. Labial biopsy was performed according to clinicians' judgement. Images of the four glands were scored 0-3 according to the scoring system and a consensus score was obtained using a developed ultrasound atlas. RESULTS: Of the 134 patients included in the analysis, 43 were diagnosed with primary SS (pSS) and all fulfilled the 2016 American College of Rheumatology (ACR)/EULAR classification criteria. More patients with pSS compared with non-pSS had score ≥2 in at least one gland (72% vs 13%; p<0.001). In patients with score ≥2 in any gland, significantly more had positive autoantibodies, sialometry, Schirmer's test and positive labial biopsy compared with those with scores ≤1. The best ultrasound cut-off value for diagnosing pSS was ≥1 gland with a score ≥2 (sensitivity=0.72, specificity=0.91). CONCLUSION: The OMERACT Ultrasound Scoring System showed good sensitivity (0.72) and excellent specificity (0.91) for fulfilling 2016 ACR/EULAR criteria using cut-off score >2 in at least one gland. Our data supports the use of ultrasound for diagnosing pSS and supports incorporation of ultrasound in the classification criteria.


Assuntos
Síndrome de Sjogren , Humanos , Glândula Parótida/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Sensibilidade e Especificidade , Síndrome de Sjogren/diagnóstico por imagem , Ultrassonografia
5.
J Rheumatol ; 42(12): 2480-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25684773

RESUMO

OBJECTIVE: To assess the intrareader and interreader agreement and sensitivity to change of the Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing (RAMRIS-JSN) score in the rheumatoid arthritis (RA) wrist in a longitudinal multireader exercise. METHODS: Coronal T1-weighted MR image sets of 1 wrist from 20 patients with early RA were assessed twice for JSN at 17 sites at baseline and after 36 or 60 months by 4 readers blinded to patient data but not time order. The joints were scored 0-4 according to the OMERACT RAMRIS-JSN score. Intraclass correlation coefficients (ICC), smallest detectable change (SDC), percentage exact/close agreement (PEA/PCA), and standardized response mean (SRM) were calculated. RESULTS: Median baseline and change score was 10.3 and 1.9, respectively. Intrareader ICC for baseline and change scores was good (≥ 0.50) to very good (≥ 0.80) for all and 3 of 4 readers, respectively. Interreader ICC was very good for change (0.93), while poor for baseline score if all 4 readers were included (0.36), but very good if 1 reader was excluded (0.87). Intrareader and interreader SDC was low (2.34-3.18), except for the intrareader SDC for 1 reader (6.75). The mean PEA/PCA was high for baseline and change scores both within and between the readers (51.5-99.2), except for interreader baseline PEA (14.4). SRM was moderate for all readers (0.55-0.77). CONCLUSION: The OMERACT RAMRIS-JSN score showed high overall intrareader and interreader reliability, and moderate sensitivity to change, supporting inclusion of the measure as part of the OMERACT RAMRIS system.


Assuntos
Artrite Reumatoide/diagnóstico , Imageamento por Ressonância Magnética/métodos , Índice de Gravidade de Doença , Articulação do Punho/patologia , Adulto , Idoso , Estudos de Coortes , Consenso , Dinamarca , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade
6.
Curr Rheumatol Rep ; 8(5): 378-85, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16973112

RESUMO

Efficient methods for diagnosis, monitoring, and prognostication are essential in early rheumatoid arthritis. Data on the value of ultrasonography and MRI are accumulating rapidly, fueling their increasing use in early rheumatoid arthritis. This review focuses on recent advances in the clinical applications of these imaging modalities.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/patologia , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...