Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Urologia ; 90(4): 670-677, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37154464

RESUMO

BACKGROUND: Isiris-α® is a single-use digital flexible cystoscope with an integrated grasper designed for double J (DJ) stent removal. Aim of this study was to conduct a multicentric evaluation of the costs and criticalities of stent removals performed with Isiris®-α in different hospitals and health systems, as compared to other DJ removal procedures. METHODS: After gathering 10 institutions worldwide with experience on Isiris-α®, we performed an analysis of the reported costs of DJ removal with Isiris-α®, as compared to the traditional reusable equipment used in each institution. The cost evaluation included instrument purchase, Endoscopic Room (EnR)/ Operatory Room (OR) occupancy, medical staff, instrument disposal, maintenance, repairs, decontamination or sterilization of reusable devices. RESULTS: The main factor affecting the costs of the procedure was OR/EnR occupancy. Decontamination and sterilization accounted for a less important part of total costs. Isiris-α® was more profitable in institutions where DJ removal is usually performed in the EnR/OR, allowing to transfer the procedure to outpatient clinic, with a significant cost saving and EnR/OR time saving to be allocated to other activities. In the only institution where DJ removal was already performed in outpatient clinics, there is a slight cost difference in favor of reusable instruments in high-volume institutions, given a sufficient number to guarantee the turnover. CONCLUSION: Isiris-α® leads to significant cost benefit in the institutions where DJ removal is routinely performed in EnR/OR, and brings significant improvement in organization, cost impact and turnover.


Assuntos
Cistoscópios , Ureter , Humanos , Custos Hospitalares , Cistoscopia/métodos , Remoção de Dispositivo , Ureter/cirurgia
2.
Can Urol Assoc J ; 13(8): 246-249, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31496490

RESUMO

INTRODUCTION: Radiation exposure during urological procedures is still of concern in the urology community. It has been reported that percutaneous nephrolithotomy (PCNL) in supine position has less irradiation, as the puncture is mostly done under ultrasound guidance. However, it can also be done under fluoroscopy guidance. Unfortunately, data on radiation exposure during PCNL is lacking since they are often drawn from generalization and extrapolation, or they do not evaluate new procedures or different positions. The aim of our study was to compare the radiation dose depending on the position of the surgeon during PCNL. METHODS: A portable C-arm was used in standard mode (32 impulsions/second; 98 kV, 3.8 mA). Specific dosimeters were placed for lens, extremity, and torso. Anthropomorphic models and hand phantom models were used to reproduce the position of surgeon and patient (with same bone density as human) during PCNL in prone and modified supine position. Fluoroscopy time (FT) was six minutes to obtain higher exploitable signal, and the results are given for a FT of three minutes (more realistic). Ten percent of the FT is done with an angulation of 15 degrees and the rest in anteroposterior position. RESULTS: The equivalent doses (ED) are given in uSV (uncertainty k=2). During the modified supine position: neck, lens, right index finger, left thumb, and index finger received EDs of 99 (20%), 62 (18%), 437 (10%), 112 (12%), and 204 (10%), respectively. In a prone position, the phantom received ED on the neck, lens, right thumb and index finger, left thumb and index finger of 85 (20%), 92 (12%), 401 (10%), 585 (10%), 295 (10%), and 567 (10%), respectively. In both positions, the right hand seems more exposed than the left hand. CONCLUSIONS: The effective dose is 1.5- and 1.3-fold higher for lens and extremities, respectively, in prone position PCNL compared to modified supine position. Both positions are still well below the recommended limit for professional exposure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...