Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Talanta ; 49(5): 1045-50, 1999 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-18967681

RESUMO

The speciation of inorganic chromium in environmental samples is required for accurate assessment of pollution levels. Of the two chromium oxidation states, Cr (VI) is a known carcinogen, while Cr (III) is an essential element. Total chromium measurement cannot be used to determine actual environmental impact due to the considerable difference in toxicity of the two elemental forms. An automated liquid handling system, the PrepLabtrade mark, can be used with an inductively coupled plasma-mass spectrometer (ICP-MS) to quantify Cr (III) and Cr (VI) in liquid samples. An autosampler is used to introduce discrete sample volumes into a solid-phase chelation resin column. The Cr (III) and Cr (VI) species are separated and are introduced on-line into the VG PlasmaQuad 3 ICP-MS for detection. The chromatographic data are collected in time resolved analysis mode with the capability of simultaneous multiple-isotopic detection.

3.
Anal Chem ; 68(21): 3859-66, 1996 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21619261

RESUMO

A gas chromatographic method was developed for the quantification of alkylmercury species using microwave-induced plasma atomic emission detection (GC-AED). The column conditioning and analyte derivatization required for previous methods were found to be unnecessary for stable, accurate, and sensitive element-specific detection using GC-AED. Chromatographic and detection parameters such as stationary phase type, stationary phase film thickness, GC column dimensions, helium mobile phase column head pressure, detector makeup gas flow rate, and detector reagent gas type and flow rate were found to significantly affect analyte response. The detection limit for the optimized GC-AED conditions was 0.8 pg (0.1 pg/s) of methylmercury chloride (as mercury). A solid-liquid extraction procedure with preparative gel permeation chromatography cleanup and GC-AED analysis was used to quantify methylmercury in a variety of complex matrix marine materials. The methylmercury quantification method was validated with four marine certified reference materials (CRMs). The method was then applied to 13 standard reference materials, CRMs, and control materials for which no certified reference values for methylmercury have been determined. Four National Institute of Standards and Technology Standard Reference Materials and one control material, which were analyzed using the GC-AED method, were also analyzed by two other laboratories using independent methods to further validate the method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...