Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 42(1): 38-46, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21497521

RESUMO

OBJECTIVE: The study aimed to review the results of endovascular aneurysm repair (EVAR) using a novel sac-anchoring endoprosthesis in patients with favourable and adverse anatomy. DESIGN: This is a prospective, multicentre, clinical trial. MATERIALS: The Nellix endoprosthesis consists of dual, balloon-expandable endoframes, surrounded by polymer-filled endobags, which obliterate the aneurysm sac and maintain endograft position. METHODS: The study reviewed worldwide clinical experience and Core Lab evaluation of computed tomography (CT) scans. RESULTS: From 2008 to 2010, 34 patients (age 71 ± 8 years, abdominal aortic aneurysm (AAA) diameter 5.8 ± 0.8 cm) were treated at four clinical sites. Seventeen patients (50%) met the inclusion criteria for Food and Drug Administration (FDA)-approved endografts (favourable anatomy); 17 (50%) had one or more adverse anatomic feature: neck length <10 mm (24%), neck angle >60° (9%) and iliac diameter >23 mm (38%). Device deployment was successful in all patients; iliac aneurysm treatment preserved hypogastric patency. Perioperative mortality was 1/34 (2.9%); one patient died at 10 months of congestive heart failure (CHF); one patient had a secondary procedure at 15 months. During 15 ± 6 months follow-up, there were no differences in outcome between favourable and adverse anatomy patients. Follow-up CT extending up to 2 years revealed no change in aneurysm size or endograft position and no new endoleaks. CONCLUSIONS: Favourable and adverse anatomy patients can be successfully treated using the Nellix sac-anchoring endoprosthesis. Early results are promising but longer-term studies are needed.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Colômbia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Letônia , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Seleção de Pacientes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Reoperação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Venezuela
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA