1.
Phys Med Biol ; 68(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37827167

RESUMO

Objective. The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy.Approach. Dedicated LGAD detectors with an active thickness of 55µm and segmented in 2 mm2strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates.Main results. The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 107p/(cm2·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam.Significance. The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.


Assuntos
Terapia com Prótons , Radiometria , Radiometria/métodos , Prótons , Silício , Ciclotrons
2.
Med Phys ; 50(9): 5817-5827, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37493525

RESUMO

BACKGROUND: The beam energy is one of the most significant parameters in particle therapy since it is directly correlated to the particles' penetration depth inside the patient. Nowadays, the range accuracy is guaranteed by offline routine quality control checks mainly performed with water phantoms, 2D detectors with PMMA wedges, or multi-layer ionization chambers. The latter feature low sensitivity, slow collection time, and response dependent on external parameters, which represent limiting factors for the quality controls of beams delivered with fast energy switching modalities, as foreseen in future treatments. In this context, a device based on solid-state detectors technology, able to perform a direct and absolute beam energy measurement, is proposed as a viable alternative for quality assurance measurements and beam commissioning, paving the way for online range monitoring and treatment verification. PURPOSE: This work follows the proof of concept of an energy monitoring system for clinical proton beams, based on Ultra Fast Silicon Detectors (featuring tenths of ps time resolution in 50 µm active thickness, and single particle detection capability) and time-of-flight techniques. An upgrade of such a system is presented here, together with the description of a dedicated self-calibration method, proving that this second prototype is able to assess the mean particles energy of a monoenergetic beam without any constraint on the beam temporal structure, neither any a priori knowledge of the beam energy for the calibration of the system. METHODS: A new detector geometry, consisting of sensors segmented in strips, has been designed and implemented in order to enhance the statistics of coincident protons, thus improving the accuracy of the measured time differences. The prototype was tested on the cyclotron proton beam of the Trento Protontherapy Center (TPC). In addition, a dedicated self-calibration method, exploiting the measurement of monoenergetic beams crossing the two telescope sensors for different flight distances, was introduced to remove the systematic uncertainties independently from any external reference. RESULTS: The novel calibration strategy was applied to the experimental data collected at TPC (Trento) and CNAO (Pavia). Deviations between measured and reference beam energies in the order of a few hundreds of keV with a maximum uncertainty of 0.5 MeV were found, in compliance with the clinically required water range accuracy of 1 mm. CONCLUSIONS: The presented version of the telescope system, minimally perturbative of the beam, relies on a few seconds of acquisition time to achieve the required clinical accuracy and therefore represents a feasible solution for beam commission, quality assurance checks, and online beam energy monitoring.


Assuntos
Terapia com Prótons , Calibragem , Terapia com Prótons/normas , Fatores de Tempo , Humanos
3.
Int J Radiat Oncol Biol Phys ; 115(5): 1257-1268, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36462690

RESUMO

PURPOSE: Treatment of locally advanced lung cancer is limited by toxicity and insufficient local control. Particle therapy could enable more conformal treatment than intensity modulated photon therapy but is challenged by irregular tumor motion, associated range changes, and tumor deformations. We propose a new strategy for robust, online adaptive particle therapy, synergizing 4-dimensional optimization with real-time adaptive beam tracking. The strategy was tested and the required motion monitoring precision was determined. METHODS AND MATERIALS: In multiphase 4-dimensional dose delivery (MP4D), a dedicated quasistatic treatment plan is delivered to each motion phase of periodic 4-dimensional computed tomography (4DCT). In the new extension, "MP4D with residual tracking" (MP4DRT), lateral beam tracking compensates for the displacement of the tumor center-of-mass relative to the current phase in the planning 4DCT. We implemented this method in the dose delivery system of a clinical carbon facility and tested it experimentally for a lung cancer plan based on a periodic subset of a virtual lung 4DCT (planned motion amplitude 20 mm). Treatments were delivered in a quality assurance-like setting to a moving ionization chamber array. We considered variable motion amplitudes and baseline drifts. The required motion monitoring precision was evaluated by adding noise to the motion signal. Log-file-based dose reconstructions were performed in silico on the entire 4DCT phantom data set capable of simulating nonperiodic motion. MP4DRT was compared with MP4D, rescanned beam tracking, and internal target volume plans. Treatment quality was assessed in terms of target coverage (D95), dose homogeneity (D5-D95), conformity number, and dose to heart and lung. RESULTS: For all considered motion scenarios and metrics, MP4DRT produced the most favorable metrics among the tested motion mitigation strategies and delivered high-quality treatments. The conformity was similar to static treatments. The motion monitoring precision required for D95 >95% was 1.9 mm. CONCLUSIONS: With clinically feasible motion monitoring, MP4DRT can deliver highly conformal dose distributions to irregularly moving targets.


Assuntos
Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Pulmão , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Quadridimensional/métodos
4.
Front Oncol ; 12: 929949, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36226070

RESUMO

Morphological changes that may arise through a treatment course are probably one of the most significant sources of range uncertainty in proton therapy. Non-invasive in-vivo treatment monitoring is useful to increase treatment quality. The INSIDE in-beam Positron Emission Tomography (PET) scanner performs in-vivo range monitoring in proton and carbon therapy treatments at the National Center of Oncological Hadrontherapy (CNAO). It is currently in a clinical trial (ID: NCT03662373) and has acquired in-beam PET data during the treatment of various patients. In this work we analyze the in-beam PET (IB-PET) data of eight patients treated with proton therapy at CNAO. The goal of the analysis is twofold. First, we assess the level of experimental fluctuations in inter-fractional range differences (sensitivity) of the INSIDE PET system by studying patients without morphological changes. Second, we use the obtained results to see whether we can observe anomalously large range variations in patients where morphological changes have occurred. The sensitivity of the INSIDE IB-PET scanner was quantified as the standard deviation of the range difference distributions observed for six patients that did not show morphological changes. Inter-fractional range variations with respect to a reference distribution were estimated using the Most-Likely-Shift (MLS) method. To establish the efficacy of this method, we made a comparison with the Beam's Eye View (BEV) method. For patients showing no morphological changes in the control CT the average range variation standard deviation was found to be 2.5 mm with the MLS method and 2.3 mm with the BEV method. On the other hand, for patients where some small anatomical changes occurred, we found larger standard deviation values. In these patients we evaluated where anomalous range differences were found and compared them with the CT. We found that the identified regions were mostly in agreement with the morphological changes seen in the CT scan.

5.
Med Phys ; 49(12): 7802-7814, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36196033

RESUMO

BACKGROUND: With rapid evolutions of fast and sophisticated calculation techniques and delivery technologies, clinics are almost facing a daily patient-specific (PS) plan adaptation, which would make a conventional experimental quality assurance (QA) workflow unlikely to be routinely feasible. Therefore, in silico approaches are foreseen by means of second-check independent dose calculation systems possibly handling machine log-files. PURPOSE: To validate the in-house developed GPU-dose engine, FRoG, for light ion beam therapy (protons and carbon ions) as a second-check independent calculation system and to integrate machine log-file analysis into the patient-specific quality assurance (PSQA) program. METHODS: Spot sizes, depth-dose distributions, and absolute dose calibrations were configured into FRoG and a set of nine regular-shaped targets in combination with more than 170 clinical treatment fields were tested against pinpoint ionization chamber measurements. Both the treatment planning system DICOM RTplans and machine treatment log-files were used as input for the dose kernel in water, and a 3D local γ (1 mm/2%) index was used as the main evaluation metric. RESULTS: Calculated configuration data matched experimental measurements with submillimetric agreement. For regular-shaped targets, the unsigned average relative difference between calculated and measured dose values was less than 2% for both protons and carbon ions. The mean γ passing rate (PR) was around 98% for both particle species. For clinical treatment beams, DICOM-based recalculations showed a γ-PR more than 99% for both particle species. The same level of agreement was preserved for protons when moving to log-file-based recalculations. A score of around 95% was registered for carbon ion beams, once excluding low-quality machine log-files. Unsigned average relative difference against acquired data was less than 2% also for real clinical beams. CONCLUSIONS: FRoG was proven as an accurate and reliable tool for PSQA in scanning light ion beam therapy. The proposed method allows for an extremely efficient workflow, without compromising the quality of the plan verification procedure.


Assuntos
Prótons , Radiometria , Humanos , Dosagem Radioterapêutica , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Método de Monte Carlo
6.
Med Phys ; 49(1): 23-40, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34813083

RESUMO

PURPOSE: In-beam positron emission tomography (PET) is one of the modalities that can be used for in vivo noninvasive treatment monitoring in proton therapy. Although PET monitoring has been frequently applied for this purpose, there is still no straightforward method to translate the information obtained from the PET images into easy-to-interpret information for clinical personnel. The purpose of this work is to propose a statistical method for analyzing in-beam PET monitoring images that can be used to locate, quantify, and visualize regions with possible morphological changes occurring over the course of treatment. METHODS: We selected a patient treated for squamous cell carcinoma (SCC) with proton therapy, to perform multiple Monte Carlo (MC) simulations of the expected PET signal at the start of treatment, and to study how the PET signal may change along the treatment course due to morphological changes. We performed voxel-wise two-tailed statistical tests of the simulated PET images, resembling the voxel-based morphometry (VBM) method commonly used in neuroimaging data analysis, to locate regions with significant morphological changes and to quantify the change. RESULTS: The VBM resembling method has been successfully applied to the simulated in-beam PET images, despite the fact that such images suffer from image artifacts and limited statistics. Three dimensional probability maps were obtained, that allowed to identify interfractional morphological changes and to visualize them superimposed on the computed tomography (CT) scan. In particular, the characteristic color patterns resulting from the two-tailed statistical tests lend themselves to trigger alarms in case of morphological changes along the course of treatment. CONCLUSIONS: The statistical method presented in this work is a promising method to apply to PET monitoring data to reveal interfractional morphological changes in patients, occurring over the course of treatment. Based on simulated in-beam PET treatment monitoring images, we showed that with our method it was possible to correctly identify the regions that changed. Moreover we could quantify the changes, and visualize them superimposed on the CT scan. The proposed method can possibly help clinical personnel in the replanning procedure in adaptive proton therapy treatments.


Assuntos
Terapia com Prótons , Humanos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
7.
Phys Med Biol ; 66(23)2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34740202

RESUMO

Objective. The purpose of this study was to perform preliminary pre-clinical tests to compare the dosimetric quality of two approaches to treating moving tumors with ion beams: synchronously delivering the beam with the motion of a moving planning target volume (PTV) using the recently developed multi-phase 4D dose delivery (MP4D) approach, and asynchronously delivering the ion beam to a motion-encompassing internal tumor volume (ITV) combined with rescanning.Approach. We created 4D optimized treatment plans with proton and carbon ion beams for two patients who had previously received treatment for non-small cell lung cancer. For each patient, we created several treatment plans, using approaches with and without motion mitigation: MP4D, ITV with rescanning, static deliveries to a stationary PTV, and deliveries to a moving tumor without motion compensation. Two sets of plans were optimized with margins or robust uncertainty scenarios. Each treatment plan was delivered using a recently-developed motion-synchronized dose delivery system (M-DDS); dose distributions in water were compared to measurements using gamma index analysis to confirm the accuracy of the calculations. Reconstructed dose distributions on the patient CT were analyzed to assess the dosimetric quality of the deliveries (conformity, uniformity, tumor coverage, and extent of hotspots).Main results. Gamma index analysis pass rates confirmed the accuracy of dose calculations. Dose coverage was >95% for all static and MP4D treatments. The best conformity and the lowest lung doses were achieved with MP4D deliveries. Robust optimization led to higher lung doses compared to conventional optimization for ITV deliveries, but not for MP4D deliveries.Significance. We compared dosimetric quality for two approaches to treating moving tumors with ion beams. Our findings suggest that the MP4D approach, using an M-DDS, provides conformal motion mitigation, with full target coverage and lower OAR doses.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Carbono , Carcinoma Pulmonar de Células não Pequenas/patologia , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Resultado do Tratamento
8.
Phys Med ; 91: 62-72, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34715550

RESUMO

PURPOSE: Highly conformal scanned Carbon Ion Radiotherapy (CIRT) might permit dose escalation and improved local control in advanced stage thoracic tumors, but is challenged by target motion. Dose calculation algorithms typically assume a periodically repeating, regular motion. To assess the effect of realistic, irregular motion, new algorithms of validated accuracy are needed. METHODS: We extended an in-house treatment planning system to calculate RBE-weighted dose distributions in CIRT on non-periodic CT image sequences. Dosimetric accuracy was validated experimentally on a moving, time-resolved ionization chamber array. Log-file based dose reconstructions were compared by gamma analysis and correlation to measurements at every intermediate detector frame during delivery. The impact of irregular motion on treatment quality was simulated on a virtual 4DCT thorax phantom. Periodic motion was compared to motion with varying amplitude and period ± baseline drift. Rescanning as a mitigation strategy was assessed on all scenarios. RESULTS: In experimental validation, average gamma pass rates were 99.89+-0.30% for 3%/3 mm and 88.2+-2.2% for 2%/2 mm criteria. Average correlation for integral dose distributions was 0.990±0.002. Median correlation for single 200 ms frames was 0.947±0.006. In the simulations, irregular motion deteriorated V95 target coverage to 81.2%, 76.6% and 79.0% for regular, irregular motion and irregular motion with base-line drift, respectively. Rescanning restored V95 to >98% for both scenarios without baseline drift, but not with additional baseline drift at 83.7%. CONCLUSIONS: The validated algorithm permits to study the effects of irregular motion and to develop and adapt appropriate motion mitigation techniques.


Assuntos
Radioterapia com Íons Pesados , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Tomografia Computadorizada Quadridimensional , Movimento (Física) , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
9.
Front Oncol ; 11: 712126, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34568041

RESUMO

PURPOSE: The purpose of this study was to validate the dosimetric performance of scanned ion beam deliveries with motion-synchronization to heterogenous targets. METHODS: A 4D library of treatment plans, comprised of up to 10 3D sub-plans, was created with robust and conventional 4D optimization methods. Each sub-plan corresponded to one phase of periodic target motion. The plan libraries were delivered to a test phantom, comprising plastic slabs, dosimeters, and heterogenous phantoms. This phantom emulated range changes that occur when treating moving tumors. Similar treatment plans, but without motion synchronization, were also delivered to a test phantom with a stationary target and to a moving target; these were used to assess how the target motion degrades the quality of dose distributions and the extent to which motion synchronization can improve dosimetric quality. The accuracy of calculated dose distributions was verified by comparison with corresponding measurements. Comparisons utilized the gamma index analysis method. Plan quality was assessed based on conformity, dose coverage, overdose, and homogeneity values, each extracted from calculated dose distributions. RESULTS: High pass rates for the gamma index analysis confirmed that the methods used to calculate and reconstruct dose distributions were sufficiently accurate for the purposes of this study. Calculated and reconstructed dose distributions revealed that the motion-synchronized and static deliveries exhibited similar quality in terms of dose coverage, overdose, and homogeneity for all deliveries considered. Motion-synchronization substantially improved conformity in deliveries with moving targets. Importantly, measurements at multiple locations within the target also confirmed that the motion-synchronized delivery system satisfactorily compensated for changes in beam range caused by the phantom motion. Specifically, the overall planning and delivery approach achieved the desired dose distribution by avoiding range undershoots and overshoots caused by tumor motion. CONCLUSIONS: We validated a dose delivery system that synchronizes the movement of the ion beam to that of a moving target in a test phantom. Measured and calculated dose distributions revealed that this system satisfactorily compensated for target motion in the presence of beam range changes due to target motion. The implication of this finding is that the prototype system is suitable for additional preclinical research studies, such as irregular anatomic motion.

10.
Front Oncol ; 11: 601784, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34178614

RESUMO

Particle therapy in which deep seated tumours are treated using 12C ions (Carbon Ions RadioTherapy or CIRT) exploits the high conformity in the dose release, the high relative biological effectiveness and low oxygen enhancement ratio of such projectiles. The advantages of CIRT are driving a rapid increase in the number of centres that are trying to implement such technique. To fully profit from the ballistic precision achievable in delivering the dose to the target volume an online range verification system would be needed, but currently missing. The 12C ions beams range could only be monitored by looking at the secondary radiation emitted by the primary beam interaction with the patient tissues and no technical solution capable of the needed precision has been adopted in the clinical centres yet. The detection of charged secondary fragments, mainly protons, emitted by the patient is a promising approach, and is currently being explored in clinical trials at CNAO. Charged particles are easy to detect and can be back-tracked to the emission point with high efficiency in an almost background-free environment. These fragments are the product of projectiles fragmentation, and are hence mainly produced along the beam path inside the patient. This experimental signature can be used to monitor the beam position in the plane orthogonal to its flight direction, providing an online feedback to the beam transverse position monitor chambers used in the clinical centres. This information could be used to cross-check, validate and calibrate, whenever needed, the information provided by the ion chambers already implemented in most clinical centres as beam control detectors. In this paper we study the feasibility of such strategy in the clinical routine, analysing the data collected during the clinical trial performed at the CNAO facility on patients treated using 12C ions and monitored using the Dose Profiler (DP) detector developed within the INSIDE project. On the basis of the data collected monitoring three patients, the technique potential and limitations will be discussed.

11.
Front Oncol ; 11: 620388, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33816251

RESUMO

BACKGROUND: Quality management and safety are integral to modern radiotherapy. New radiotherapy technologies require new consensus guidelines on quality and safety. Established analysis strategies, such as the failure modes and effects analysis (FMEA) and incident learning systems have been developed as tools to assess the safety of several types of radiation therapies. An extensive literature documents the widespread application of risk analysis methods to photon radiation therapy. Relatively little attention has been paid to performing risk analyses of nascent radiation therapy systems to treat moving tumors with scanned heavy ion beams. The purpose of this study was to apply a comprehensive safety analysis strategy to a motion-synchronized dose delivery system (M-DDS) for ion therapy. METHODS: We applied a risk analysis method to new treatment planning and treatment delivery processes with scanned heavy ion beams. The processes utilize a prototype, modular dose delivery system, currently undergoing preclinical testing, that provides new capabilities for treating moving anatomy. Each step in the treatment process was listed in a process map, potential errors for each step were identified and scored using the risk probability number in an FMEA, and the possible causes of each error were described in a fault tree analysis. Solutions were identified to mitigate the risk of these errors, including permanent corrective actions, periodic quality assurance (QA) tests, and patient specific QA (PSQA) tests. Each solution was tested experimentally. RESULTS: The analysis revealed 58 potential errors that could compromise beam delivery quality or safety. Each of the 14 binary (pass-or-fail) tests passed. Each of the nine QA and four PSQA tests were within anticipated clinical specifications. The modular M-DDS was modified accordingly, and was found to function at two centers. CONCLUSION: We have applied a comprehensive risk analysis strategy to the M-DDS and shown that it is a clinically viable motion mitigation strategy. The described strategy can be utilized at any ion therapy center that operates with the modular M-DDS. The approach can also be adapted for use at other facilities and can be combined with existing safety analysis systems.

12.
Phys Med ; 76: 307-316, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32739784

RESUMO

PURPOSE: The purpose of this study was to develop a modular dose-delivery system (DDS) for scanned-ion radiotherapy that mitigates against organ motion artifacts by synchronizing the motion of the beam with that of the moving anatomy. METHODS: We integrated a new motion synchronization system and an existing DDS into two centers. The modular approach to integration utilized an adaptive layer of software and hardware interfaces. The method of synchronization comprised three major tasks, namely, the creation of 3D treatment plans (each representing one phase of respiratory motion and together comprising a 4D plan), monitoring anatomic motion during treatment, and synchronization of the beam to anatomic motion. The synchronization was accomplished in real time by repeatedly selecting and delivering a 3D plan, i.e., the one that most closely corresponded to the current anatomic state, until all plans were delivered. The performance characteristics of the motion mitigation system were tested by delivering 4D treatment plans to a moving phantom and comparing planned and measured dose distributions. Dosimetric performance was considered acceptable when the gamma-index pass rate was >90%, homogeneity-index value was >95%, and conformity-index value was >60%. Selected safety characteristics were tested by introducing errors during treatment and testing DDS response. RESULTS: Acceptable dosimetric performance and safety characteristics were observed for all treatment plans. CONCLUSIONS: We demonstrated, for the first time, that a modular prototype system, synchronizing scanned ion beams with moving targets can deliver conformal, motion-compensated dose distributions. The prototype system was implemented and characterized at GSI and CNAO.


Assuntos
Radiometria , Planejamento da Radioterapia Assistida por Computador , Movimento (Física) , Imagens de Fantasmas , Dosagem Radioterapêutica
13.
Med Phys ; 47(4): 1468-1480, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31971612

RESUMO

PURPOSE: A retrospective analysis of the dose delivery system (DDS) performances of the initial clinical operation at CNAO (Centro Nazionale di Adroterapia Oncologica) is reported, and compared with the dose delivery accuracy following the implementation of a position feedback control. METHODS: Log files and raw data of the DDS were analyzed for every field of patients treated with protons and carbon ions between January 2012 and April 2013 (~3800 fields). To investigate the DDS accuracy, the spot positions and the number of particles per spot measured by the DDS and prescribed by the treatment planning system were compared for each field. The impact of deviations on dose distributions was studied by comparing, through the gamma-index method, 2 three-dimensional (3D) physical dose maps (one for prescribed, one for measured data), generated by a validated dose computation software. The maximum gamma and the percentage of points with gamma ≤ 1 (passing volume) were studied as a function of the treatment day, and correlated with the deviations from the prescription in the measured number of particles and spot positions. Finally, delivered dose distributions of same treatment plans were compared before and after the implementation of a feedback algorithm for the correction of small position deviations, to study the effect on the delivery quality. A double comparison of prescribed and measured 3D maps, before and after feedback implementation, is reported and studied for a representative treatment delivered in 2012, redelivered on a polymethyl methacrylate (PMMA) block in 2018. RESULTS: Systematic deviations of spot positions, mainly due to beam lateral offsets, were always found within 1.5 mm, with the exception of the initial clinical period. The number of particles was very stable, as possible deviations are exclusively related to the quantization error in the conversion from monitor counts to particles. For the chosen representative patient treatment, the gamma-index evaluation of prescribed and measured dose maps, before and after feedback implementation, showed a higher variability of maximum gamma for the 2012 irradiation, with respect to the reirradiation of 2018. However, the 2012 passing volume is >99.8% for the sum of all fields, which is comparable to the value of 2018, with the exception of one day with 98.2% passing volume, probably related to an instability of the accelerating system. CONCLUSIONS: A detailed retrospective analysis of the DDS performances in the initial period of CNAO clinical activity is reported. The spot position deviations are referable to beam lateral offset fluctuations, while almost no deviation was found in the number of particles. The impact of deviations on dose distributions showed that the position feedback implementation and the increased beam control capability acquired after the first years of clinical experience led to an evident improvement in the DDS stability, evaluated in terms of gamma-index as a measure of the impact on dose distributions. However, the clinical effect of the maximum gamma variability found in the 2012 representative irradiation is mitigated by averaging along the number of fractions, and the high percentage of passing volumes confirmed the accuracy of the delivery even before the feedback implementation.


Assuntos
Doses de Radiação , Radioterapia Assistida por Computador/métodos , Radioterapia com Íons Pesados , Humanos , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
14.
Sci Rep ; 8(1): 4100, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29511282

RESUMO

Particle therapy exploits the energy deposition pattern of hadron beams. The narrow Bragg Peak at the end of range is a major advantage but range uncertainties can cause severe damage and require online verification to maximise the effectiveness in clinics. In-beam Positron Emission Tomography (PET) is a non-invasive, promising in-vivo technique, which consists in the measurement of the ß+ activity induced by beam-tissue interactions during treatment, and presents the highest correlation of the measured activity distribution with the deposited dose, since it is not much influenced by biological washout. Here we report the first clinical results obtained with a state-of-the-art in-beam PET scanner, with on-the-fly reconstruction of the activity distribution during irradiation. An automated time-resolved quantitative analysis was tested on a lacrimal gland carcinoma case, monitored during two consecutive treatment sessions. The 3D activity map was reconstructed every 10 s, with an average delay between beam delivery and image availability of about 6 s. The correlation coefficient of 3D activity maps for the two sessions (above 0.9 after 120 s) and the range agreement (within 1 mm) prove the suitability of in-beam PET for online range verification during treatment, a crucial step towards adaptive strategies in particle therapy.


Assuntos
Carcinoma/radioterapia , Aparelho Lacrimal/patologia , Tomografia por Emissão de Pósitrons/métodos , Terapia com Prótons/métodos , Humanos , Imageamento Tridimensional/métodos , Resultado do Tratamento
15.
Phys Med ; 32(12): 1667-1671, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27890567

RESUMO

PURPOSE: The aim of this work was the commissioning of delivery procedures for the treatment of moving targets in scanning pencil beam hadrontherapy. METHODS: EBT3 films fixed to the Anzai Respiratory Phantom were exposed to carbon ion scanned homogeneous fields (E=332MeV/u). To evaluate the interplay effect, field size and flatness for 3 different scenarios were compared to static condition: gated irradiation or repainting alone and combination of both. Respiratory signal was provided by Anzai pressure sensor or optical tracking system (OTS). End-exhale phase and 1s gating window were chosen (2.5mm residual motion). Dose measurements were performed using a PinPoint ionization chamber inserted into the Brainlab ET Gating Phantom. A sub-set of tests was also performed using proton beams. RESULTS: The combination of gating technique and repainting (N=5) showed excellent results (6.1% vs 4.3% flatness, identical field size and dose deviation within 1.3%). Treatment delivery time was acceptable. Dose homogeneity for gated irradiation alone was poor. Both Anzai sensor and OTS appeared suitable for providing respiratory signal. Comparisons between protons and carbon ions showed that larger beam spot sizes represent more favorable condition for minimizing motion effect. CONCLUSION: Results of measurements performed on different phantoms showed that the combination of gating and layered repainting is suitable to treat moving targets using scanning ion beams. Abdominal compression using thermoplastic masks, together with multi-field planning approach and multi-fractionation, have also been assessed as additional strategies to mitigate the effect of patient respiration in the clinical practice.


Assuntos
Movimento , Terapia com Prótons/instrumentação , Síncrotrons , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Respiração