1.
Phys Med Biol ; 62(4): N58-N72, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-27992385

RESUMO

In this study, we present a new method for estimating the time-activity data using serial timely measurements of thermoluminescent dosimeters (TLDs). The approach is based on the combination of the measurement of surface dose using TLD and Monte Carlo (MC) simulation to estimate the radiopharmaceutical time-activity data. It involves four steps: (1) identify the source organs and outline their contours in computed tomography images; (2) compute the S values on the body surface for each source organ using a MC code; (3) obtain a serial measurement of the dose with numerous TLDs placed on the body surface; (4) solve the dose-activity equation to generate organ cumulative activity for each period of measurement. The activity of each organ at the time of measurement is simply the cumulative activity divided by the timespan between measurements. The usefulness of this method was studied using a MC simulation based on an Oak Ridge National Laboratory mathematical phantom with 18F-FDG filled in six source organs. Numerous TLDs were placed on different locations of the surface and were repeatedly read and replaced. The time-activity curves (TACs) of all organs were successfully reconstructed. Experiments on a physical phantom were also performed. Preliminary results indicate that it is an effective, robust, and simple method for assessing the TAC. The proposed method holds great potential for a range of applications in areas such as targeted radionuclide therapy, pharmaceutical research, and patient-specific dose estimation.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Compostos Radiofarmacêuticos/farmacocinética , Dosimetria Termoluminescente/métodos , Humanos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Distribuição Tecidual
2.
Med Phys ; 38(7): 4094-100, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21859009

RESUMO

PURPOSE: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. METHODS: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. RESULTS: The average +/- standard deviation CBT and breast glandularity in this study were 4.2 +/- 1.0 cm and 54% +/- 23%, respectively. The average equivalent PMMA thickness was 4.0 +/- 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. CONCLUSIONS: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.


Assuntos
Envelhecimento , Materiais Biomiméticos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/fisiopatologia , Imagens de Fantasmas , Polimetil Metacrilato/química , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taiwan/epidemiologia , Adulto Jovem
3.
AJR Am J Roentgenol ; 196(4): W476-81, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21427314

RESUMO

OBJECTIVE: The currently used model breast for mammographic dosimetry assessment lacks the flexibility to change dimensions. The aim of this study was to develop an adjustable model breast for mammographic dosimetry assessment of Taiwanese women. MATERIALS AND METHODS: A retrospective review of 4226 craniocaudal (CC) views was conducted. The geometry of the model breast was defined as a semielliptical cylinder. Breast parameters, including compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content, were measured and analyzed. To validate the adjustable model breast, 44 mammograms were obtained. The expected values from the adjustable model breast were compared with the measured values. RESULTS: The average values of compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content of the women studied were 4.1 cm, 6.9 cm, 16.9 cm, and 54%, respectively. Variations of chest wall-to-nipple distance, compressed breast width, and percentage glandular content can be expressed as functions of compressed breast thickness, and the adjustable model breast developed was based on compressed breast thickness. The average area of the CC view obtained is a factor of 0.81 lower than that defined by the American College of Radiology protocol. For validation, the difference in average values between the expected and measured did not exceed 0.5 cm in breast dimensions and 6% in percentage glandular content. CONCLUSION: Compressed breast thickness is useful for quantifying dimensions and percentage glandular content of a model breast. The adjustable model breast developed in this study can offer greater flexibility in the determination of breast dimensions for mammographic dosimetry assessment of Taiwanese women.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/anatomia & histologia , Mamografia , Modelos Anatômicos , Adulto , Idoso , Calibragem , Feminino , Humanos , Análise dos Mínimos Quadrados , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiometria , Estudos Retrospectivos , Taiwan