Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Chem ; 59(11): 1107-1115, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33818821

RESUMO

Four manufacturing impurities of D&C Red No. 33 isolated by counter-current chromatography were analyzed by NMR and ESI mass spectrometry. Three of these impurities were reported previously with minimal details of structural determination. All four are structurally related to the main component of the dye. The fourth exhibited an unusual discrepancy between the NMR structure and its chemical formula suggested by ESI-MS results. Structural determination and assignment of the main component and four impurities are discussed as well as resolution of the discrepancy between the NMR and ESI-MS results of the fourth impurity.

2.
Radiology ; 232(3): 830-3, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15273337

RESUMO

PURPOSE: To determine if nonenhancing tissue on gadolinium-enhanced magnetic resonance (MR) images obtained 3 weeks after cryoablation of the prostate helps reliably and accurately predict nonviable cryoablated tissue at 6-month biopsy. MATERIALS AND METHODS: Fifty-four consecutive patients with prostate cancer who underwent cryoablation were followed up prospectively. Fifty-one underwent gadolinium-enhanced MR imaging at 3 weeks (three had gadolinium allergy); 49, biopsy at 6 months (three refused and two had other primary malignancies); and all, prostate-specific antigen (PSA) tests at 6 weeks, 3 months, and every 3 months thereafter. MR images were evaluated and scored according to the degree of signal void and were correlated with the 6-month biopsy reports and, to a lesser degree, PSA levels. The biopsy reports were examined for the presence or absence of cancerous tissue, viable tissue, and nonviable tissue. A one-way analysis of variance was used for statistical and regression analyses. RESULTS: The correlation of MR imaging scores with PSA levels and MR imaging scores with biopsy findings resulted in P values of.337 and.780, respectively. A slight statistically significant trend existed for the relation of biopsy results with PSA levels, with a P value of.041, which was expected. CONCLUSION: Findings of postoperative gadolinium-enhanced MR imaging are not predictive of 6-month biopsy results or follow-up PSA levels.


Assuntos
Criocirurgia , Imageamento por Ressonância Magnética , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Idoso , Biópsia por Agulha , Seguimentos , Gadolínio , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...