Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; PP2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833388

RESUMO

OBJECTIVE: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). METHODS: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. RESULTS: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. CONCLUSION: Simulation and experimental results indicate good detection and location of inclusions. SIGNIFICANCE: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38576194

RESUMO

OBJECTIVE: We sought to determine whether thoracic electrical impedance tomography (EIT) could characterize pulmonary function in amyotrophic lateral sclerosis (ALS) patients, including those with facial weakness. Thoracic EIT is a noninvasive, technology in which a multi-electrode belt is placed across the chest, producing real-time impedance imaging of the chest during breathing. METHODS: We enrolled 32 ALS patients and 32 age- and sex-matched healthy controls (HCs) without underlying lung disease. All participants had EIT measurements performed simultaneously with standard pulmonary function tests (PFTs), including slow and forced vital capacity (SVC and FVC) in upright and supine positions and maximal inspiratory and expiratory pressures (MIPs and MEPs, respectively). Intraclass correlation coefficients (ICCs) were calculated to assess the immediate reproducibility of EIT measurements and Pearson's correlations were used to explore the relationships between EIT and PFT values. RESULTS: Data from 30 ALS patients and 27 HCs were analyzed. Immediate upright SVC reproducibility was very high (ICC 0.98). Correlations were generally strongest between EIT and spirometry measures, with R values ranging from 0.64 to 0.82 (p < 0.001) in the ALS cohort. There were less robust correlations between EIT values and both MIPs and MEPs in the ALS patients, with R values ranging from 0.33 to 0.44. There was no significant difference for patients with and without facial weakness. There were no reported adverse events. CONCLUSION: EIT-based pulmonary measures hold the promise of providing an alternative approach for lung function assessment in ALS patients. Based on these early results, further development and study of this technology are warranted.


Assuntos
Esclerose Lateral Amiotrófica , Impedância Elétrica , Testes de Função Respiratória , Humanos , Esclerose Lateral Amiotrófica/fisiopatologia , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Esclerose Lateral Amiotrófica/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória/métodos , Idoso , Tomografia/métodos , Adulto , Reprodutibilidade dos Testes , Capacidade Vital/fisiologia , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem
3.
Artigo em Inglês | MEDLINE | ID: mdl-38083704

RESUMO

Radical prostatectomy (RP) is a common surgical therapy to treat prostate cancer. The procedure has a high positive surgical margin (PSM) rate ranging from 4-48%. Patients with PSMs have a higher rate of cancer recurrence and often undergo noxious adjuvant therapy. Intraoperative surgical margin assessment (SMA) with an electrical impedance-based probe can potentially identify PSMs in real-time. This would enable surgeons to make data-based decisions in the operating room to improve patient outcomes. This paper focuses on characterizing an impedance sensing SMA probe with specialized electrodes to improve speed and bandwidth while maintaining accuracy. 3D electrical impedance tomography (EIT) reconstructions were generated from ex vivo bovine tissue to characterize probe imaging and to determine an optimal applied pressure range (15 Pa to 38 Pa). Classification accuracy of adipose and muscle tissue was evaluated by comparing the experimental data set to simulated data based on a ground truth binary map of the tissue. Experimental AUCs ≥0.83 were maintained up to 50 kHz. The developed impedance sensing probe successfully classified between muscle and adipose tissue in an ex vivo bovine model. Future work includes improving performance of the SMA probe with custom hardware and collecting data from ex vivo and in vivo prostatic tissues.Clinical Relevance-This technology is expected to reduce the rate of PSMs in RP and decrease the use of post-surgical adjuvant therapies. It is also anticipated that intraoperative impedance measurements will increase efficacy of nerve sparing procedures and reduce complications such as incontinence and erectile dysfunction.


Assuntos
Margens de Excisão , Neoplasias da Próstata , Masculino , Humanos , Animais , Bovinos , Impedância Elétrica , Recidiva Local de Neoplasia , Próstata/cirurgia , Neoplasias da Próstata/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA