Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Hum Vaccin Immunother ; 16(10): 2456-2464, 2020 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-32119591

RESUMO

Takeda has developed a live-attenuated dengue tetravalent vaccine candidate (TAK-003) which has been shown to be immunogenic with acceptable reactogenicity in phase 1 trials. In agreement with World Health Organization prequalification requirements for dengue vaccines, Takeda has manufactured a lyophilized formulation of TAK-003 that allows stable storage at +2°C to +8°C. This randomized, double-blind, phase 2 study (NCT02193087) was performed in 1002 healthy dengue-naïve adults, 18-49 years of age, across seven centers in the USA to compare the safety and immunogenicity of one or two doses of a lyophilized TAK-003 formulation with the liquid TAK-003 formulation used in previous phase 1 studies. The primary objective was to show immunologic equivalence in terms of geometric mean titers (GMT) of neutralizing antibodies to the four dengue serotypes one month after one dose of the lyophilized and liquid formulations. Secondary assessments were of safety and seropositivity rates, including after a second dose. The primary endpoint was not met, because immunologic equivalence after one dose was only shown for the DENV-2 serotype. Nonetheless, GMTs and seropositivity rates to all four serotypes were achieved with all formulations after two doses and are in line with what was observed in previous studies. Additionally, in view of the acceptable reactogenicity, with no vaccine-related serious adverse events reported, these data support continuing further clinical development of the lyophilized TAK-003 formulation.


Assuntos
Vacinas contra Dengue , Vírus da Dengue , Dengue , Adulto , Anticorpos Neutralizantes , Anticorpos Antivirais , Dengue/prevenção & controle , Vacinas contra Dengue/efeitos adversos , Humanos , Imunogenicidade da Vacina , Vacinas Atenuadas/efeitos adversos , Vacinas Combinadas
2.
Qual Life Res ; 27(8): 2035-2044, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29858746

RESUMO

PURPOSE: Chronic axial low-back pain is a debilitating disorder that impacts all aspects of an afflicted individual's life. Effective, durable treatments have historically been elusive. Interventional therapies, such as spinal cord stimulation (SCS), have shown limited efficacy at best. Recently, a novel treatment, 10 kHz SCS, has demonstrated superior pain relief compared with traditional SCS in a randomized controlled trial (RCT). In this manuscript, we report on the long-term improvements in quality of life (QoL) outcomes for subjects enrolled in this study. METHODS: A prospective, multicenter, randomized controlled trial (SENZA-RCT) was conducted. Patients with both chronic back and leg pain were enrolled and randomized (1:1) into 10 kHz SCS or traditional SCS treatment groups. A total of 171 subjects received a permanent SCS device implant. QoL and functionality measures were collected up to 12 months. The device remote control utilization, which is an indication of patient interaction with the device for adjustments, was collected at 24-month post-implantation. RESULTS: At 12 months, a higher proportion of 10 kHz SCS subjects had marked improvement of their disability (Oswestry Disability Index) to a "moderate" or "minimal" impact on their daily function versus the control group. The subjects also reported better improvement in the Global Assessment of Functioning, Clinician Global Impression of Change, Pittsburgh Sleep Quality Index, and short-form McGill Pain Questionnaire, compared to traditional SCS subjects. The 10 kHz SCS subjects also reported far higher rates of both driving and sleeping with their device turned on, as well as reduced reliance on their programmers to adjust therapy settings. CONCLUSIONS: In addition to superior pain relief, 10 kHz SCS provides long-term improvements in quality of life and functionality for subjects with chronic low-back and leg pain. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01609972).


Assuntos
Dor Crônica/terapia , Dor Lombar/terapia , Neuralgia/terapia , Manejo da Dor/métodos , Qualidade de Vida/psicologia , Estimulação da Medula Espinal/métodos , Adulto , Idoso , Dor Crônica/psicologia , Feminino , Humanos , Dor Lombar/psicologia , Masculino , Pessoa de Meia-Idade , Medição da Dor/métodos , Estudos Prospectivos , Coluna Vertebral/patologia , Inquéritos e Questionários , Resultado do Tratamento , Escala Visual Analógica
3.
Pain Physician ; 20(4): 331-341, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28535555

RESUMO

BACKGROUND: Spinal cord stimulation (SCS) has been successfully used to treat chronic intractable pain for over 40 years. Successful clinical application of SCS is presumed to be generally dependent on maximizing paresthesia-pain overlap; critical to achieving this is positioning of the stimulation field at the physiologic midline. Recently, the necessity of paresthesia for achieving effective relief in SCS has been challenged by the introduction of 10 kHz paresthesia-free stimulation. In a large, prospective, randomized controlled pivotal trial, HF10 therapy was demonstrated to be statistically and clinically superior to paresthesia-based SCS in the treatment of severe chronic low back and leg pain. HF10 therapy, unlike traditional paresthesia-based SCS, requires no paresthesia to be experienced by the patient, nor does it require paresthesia mapping at any point during lead implant or post-operative programming. OBJECTIVES: To determine if pain relief was related to technical factors of paresthesia, we measured and analyzed the paresthesia responses of patients successfully using HF10 therapy. STUDY DESIGN: Prospective, multicenter, non-randomized, non-controlled interventional study. SETTING: Outpatient pain clinic at 10 centers across the US and Italy. METHODS: Patients with both back and leg pain already implanted with an HF10 therapy device for up to 24 months were included in this multicenter study. Patients provided pain scores prior to and after using HF10 therapy. Each patient's most efficacious HF10 therapy stimulation program was temporarily modified to a low frequency (LF; 60 Hz), wide pulse width (~470 mus), paresthesia-generating program. On a human body diagram, patients drew the locations of their chronic intractable pain and, with the modified program activated, all regions where they experienced LF paresthesia. Paresthesia and pain drawings were then analyzed to estimate the correlation of pain relief outcomes to overlap of pain by paresthesia, and the mediolateral distribution of paresthesia (as a surrogate of physiologic midline lead positioning). RESULTS: A total of 61 patients participated across 11 centers. Twenty-eight men and 33 women with a mean age of 56 ± 12 years of age participated in the study. The average duration of implantable pulse generator (IPG) implant was 19 ± 9 months. The average predominant pain score, as measured on a 0 - 10 visual analog scale (VAS), prior to HF10 therapy was 7.8 ± 1.3 and at time of testing was 2.5 ± 2.1, yielding an average pain relief of 70 ± 24%. For all patients, the mean paresthesia coverage of pain was 21 ± 28%, with 43% of patients having zero paresthesia coverage of pain. Analysis revealed no correlation between percentage of LF paresthesia overlap of predominant pain and HF10 therapy efficacy (P = 0.56). Exact mediolateral positioning of the stimulation electrodes was not found to be a statistically significant predictor of pain relief outcomes. LIMITATIONS: Non-randomized/non-controlled study design; short-term evaluation; certain technical factors not investigated. CONCLUSION: Both paresthesia concordance with pain and precise midline positioning of the stimulation contacts appear to be inconsequential technical factors for successful HF10 therapy application. These results suggest that HF10 therapy is not only paresthesia-free, but may be paresthesia-independent.


Assuntos
Dor Crônica/terapia , Parestesia/terapia , Estimulação da Medula Espinal , Adulto , Idoso , Animais , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Medula Espinal/cirurgia , Resultado do Tratamento , Estados Unidos
4.
Neurosurgery ; 79(5): 667-677, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27584814

RESUMO

BACKGROUND: Pain relief with spinal cord stimulation (SCS) has focused historically on paresthesias overlapping chronically painful areas. A higher level evidence supports the use of SCS in treating leg pain than supports back pain, as it is difficult to achieve adequate paresthesia coverage, and then pain relief, in the low back region. In comparison, 10-kHz high-frequency (HF10 therapy) SCS therapy does not rely on intraoperative paresthesia mapping and remains paresthesia-free during therapy. OBJECTIVE: To compare long-term results of HF10 therapy and traditional low-frequency SCS. METHODS: A pragmatic randomized, controlled, pivotal trial with 24-month follow-up was conducted across 11 comprehensive pain treatment centers. Subjects had Visual Analog Scale scores of ≥5.0/10.0 cm for both back and leg pain, and were assigned randomly (1:1) to receive HF10 therapy or low-frequency SCS. The primary end point was a responder rate, defined as ≥50% back pain reduction from baseline at 3 months with a secondary end point at 12 months (previously reported). In this article, 24-month secondary results are presented. Non-inferiority was first assessed, and if demonstrated the results were tested for superiority. RESULTS: In the study, 198 subjects were randomized (101 HF10 therapy, 97 traditional SCS). One hundred seventy-one subjects (90 HF10 therapy, 81 traditional SCS) successfully completed a short-term trial and were implanted. Subjects averaged 54.9 ± 12.9 years old, 13.6 ± 11.3 years since diagnosis, 86.6% had back surgery, 88.3% were taking opioid analgesics. At 3 months, 84.5% of implanted HF10 therapy subjects were responders for back pain and 83.1% for leg pain, and 43.8% of traditional SCS subjects were responders for back pain and 55.5% for leg pain (P < .001 for both back and leg pain comparisons, non-inferiority and superiority). At 24 months, more subjects were responders to HF10 therapy than traditional SCS (back pain: 76.5% vs 49.3%; 27.2% difference, 95% CI, 10.1%-41.8%; P < .001 for non-inferiority and superiority; leg pain: 72.9% vs 49.3%; 23.6% difference, 95% CI, 5.9%-38.6%; P < .001 for non-inferiority and P = .003 for superiority). Also at 24 months, back pain decreased to a greater degree with HF10 therapy (66.9% ± 31.8%) than traditional SCS (41.1% ± 36.8%, P < .001 for non-inferiority and superiority). Leg pain also decreased to a greater degree with HF10 therapy (65.1% ± 36.0%) than traditional SCS (46.0% ± 40.4%, P < .001 for non-inferiority and P = .002 for superiority). CONCLUSION: This study demonstrates long-term superiority of HF10 therapy compared with traditional SCS in treating both back and leg pain. The advantages of HF10 therapy are anticipated to impact the management of chronic pain patients substantially. ABBREVIATIONS: IPG, implantable pulse generatorMCID, minimal clinically important differencePI, permanent implantODI, Oswestry Disability IndexSCS, spinal cord stimulationVAS, Visual Analog Scale.


Assuntos
Dor Crônica/terapia , Síndrome Pós-Laminectomia/terapia , Radiculopatia/terapia , Estimulação da Medula Espinal/métodos , Adulto , Idoso , Dor nas Costas/etiologia , Dor nas Costas/terapia , Dor Crônica/etiologia , Feminino , Humanos , Degeneração do Disco Intervertebral/complicações , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Manejo da Dor/métodos , Medição da Dor , Parestesia/etiologia , Radiculopatia/etiologia , Escala Visual Analógica
6.
J Clin Invest ; 126(5): 1734-44, 2016 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-27018593

RESUMO

BACKGROUND: Clinical laboratory tests are now being prescribed and made directly available to consumers through retail outlets in the USA. Concerns with these test have been raised regarding the uncertainty of testing methods used in these venues and a lack of open, scientific validation of the technical accuracy and clinical equivalency of results obtained through these services. METHODS: We conducted a cohort study of 60 healthy adults to compare the uncertainty and accuracy in 22 common clinical lab tests between one company offering blood tests obtained from finger prick (Theranos) and 2 major clinical testing services that require standard venipuncture draws (Quest and LabCorp). Samples were collected in Phoenix, Arizona, at an ambulatory clinic and at retail outlets with point-of-care services. RESULTS: Theranos flagged tests outside their normal range 1.6× more often than other testing services (P < 0.0001). Of the 22 lab measurements evaluated, 15 (68%) showed significant interservice variability (P < 0.002). We found nonequivalent lipid panel test results between Theranos and other clinical services. Variability in testing services, sample collection times, and subjects markedly influenced lab results. CONCLUSION: While laboratory practice standards exist to control this variability, the disparities between testing services we observed could potentially alter clinical interpretation and health care utilization. Greater transparency and evaluation of testing technologies would increase their utility in personalized health management. FUNDING: This work was supported by the Icahn Institute for Genomics and Multiscale Biology, a gift from the Harris Family Charitable Foundation (to J.T. Dudley), and grants from the NIH (R01 DK098242 and U54 CA189201, to J.T. Dudley, and R01 AG046170 and U01 AI111598, to E.E. Schadt).


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Adulto , Idoso , Arizona , Análise Química do Sangue/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
7.
Anesthesiology ; 123(4): 851-60, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26218762

RESUMO

BACKGROUND: Current treatments for chronic pain have limited effectiveness and commonly known side effects. Given the prevalence and burden of intractable pain, additional therapeutic approaches are desired. Spinal cord stimulation (SCS) delivered at 10 kHz (as in HF10 therapy) may provide pain relief without the paresthesias typical of traditional low-frequency SCS. The objective of this randomized, parallel-arm, noninferiority study was to compare long-term safety and efficacy of SCS therapies in patients with back and leg pain. METHODS: A total of 198 subjects with both back and leg pain were randomized in a 1:1 ratio to a treatment group across 10 comprehensive pain treatment centers. Of these, 171 passed a temporary trial and were implanted with an SCS system. Responders (the primary outcome) were defined as having 50% or greater back pain reduction with no stimulation-related neurological deficit. RESULTS: At 3 months, 84.5% of implanted HF10 therapy subjects were responders for back pain and 83.1% for leg pain, and 43.8% of traditional SCS subjects were responders for back pain and 55.5% for leg pain (P < 0.001 for both back and leg pain comparisons). The relative ratio for responders was 1.9 (95% CI, 1.4 to 2.5) for back pain and 1.5 (95% CI, 1.2 to 1.9) for leg pain. The superiority of HF10 therapy over traditional SCS for leg and back pain was sustained through 12 months (P < 0.001). HF10 therapy subjects did not experience paresthesias. CONCLUSION: HF10 therapy promises to substantially impact the management of back and leg pain with broad applicability to patients, physicians, and payers.


Assuntos
Dor nas Costas/terapia , Dor Crônica/terapia , Perna (Membro) , Estimulação da Medula Espinal/métodos , Estimulação da Medula Espinal/normas , Adulto , Idoso , Dor nas Costas/diagnóstico , Dor Crônica/diagnóstico , Feminino , Seguimentos , Humanos , Perna (Membro)/patologia , Masculino , Pessoa de Meia-Idade , Manejo da Dor/métodos , Manejo da Dor/normas , Estudos Prospectivos , Resultado do Tratamento
8.
Neuromodulation ; 15(2): 100-6; discussion 106-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21854499

RESUMO

OBJECTIVES: While pain in the extremities often responds to treatment using spinal cord stimulation (SCS), axial pain is notoriously refractory to SCS. Interest in subcutaneous peripheral nerve stimulation (SQ PNS) as an alternative to SCS has emerged, but the most appropriate electrode locations and neurostimulator programming techniques are not yet clear. METHODS: A retrospective review was conducted of consecutive patients evaluated from August 2009 to December 2010 who had undergone trial of SQ PNS with inter-lead stimulation for axial spine pain. Patients proceeding to implant were followed postoperatively with routine clinical visits and a survey form at last follow-up. Ultrasound was used intraoperatively to ensure placement of electrodes at the appropriate depth in patients with larger body mass index. Primary outcome was patient-reported pain relief at last follow-up. Literature review was conducted by searching MEDLINE (1948-present) and through an unstructured review by the authors. RESULTS: Ten patients underwent trial of SQ PNS and six proceeded to permanent implantation. Fifty percent (3/6) of implanted patients preferred neurostimulation programming that included inter-lead stimulation ("cross-talk"). Average duration of postoperative follow-up was 4.5 months (range 2-9 months). Average patient-reported pain relief at last follow-up was 45% (range 20-80%). One patient required re-operation for migration. Patients not proceeding to implant had paresthesia coverage but no analgesia. CONCLUSION: SQ PNS is a promising therapy for axial neck and back pain based on a small cohort of patients. Ultrasound was useful to assist with electrode placement at the most appropriate depth beneath the skin. While inter-lead stimulation has been preferred by patients in published reports, we did not find it clearly influenced pain relief. Future investigations should include a randomized, controlled study design, as well as defined implantation technique and neurostimulator programming algorithms.


Assuntos
Dor Lombar/terapia , Cervicalgia/terapia , Nervos Periféricos/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Idoso , Eletrodos Implantados , Feminino , Seguimentos , Humanos , Dor Lombar/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Cervicalgia/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...