Opt Express ; 24(23): 25911-25921, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27857330

RESUMO

The absolute responsivity of a planar cryogenic radiometer fabricated from micromachined silicon and having carbon nanotubes, as the absorber and thermistor were measured in the visible and far infrared (free-field terahertz) wavelength range by means of detector-based radiometry. The temperature coefficient of the thermistor near 4.8 K and noise equivalent power were evaluated along with independent characterization of the window transmittance and specular reflectance of the nanotube absorber. Measurements of absolute power by means of electrical substitution are compared to the German national standard and the uncertainty of the radiometer responsivity as a function of wavelength is summarized.

2.
Med Phys ; 40(8): 081501, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927297

RESUMO

This report is primarily concerned with methods for optical calibration of laser power for continuous wave (CW) light sources, predominantly used in photodynamic therapy (PDT). Light power calibration is very important for PDT, however, no clear standard has been established for the calibration procedure nor the requirements of power meters suitable for optical power calibration. The purposes of the report are to provide guidance for establishing calibration procedures for thermopile type power meters and establish calibration uncertainties for most commercially available detectors and readout assemblies. The authors have also provided a review of the use of various power meters for CW and pulsed optical sources, and provided recommended temporal frequencies for optical power meter calibrations and guidance for routine quality assurance procedure.


Assuntos
Fenômenos Ópticos , Fotoquimioterapia/métodos , Relatório de Pesquisa , Calibragem , Guias como Assunto , Humanos , Lasers , Luz , Fotoquimioterapia/normas , Controle de Qualidade , Padrões de Referência , Incerteza
3.
J Res Natl Inst Stand Technol ; 114(5): 287-91, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-27504228

RESUMO

This paper discusses a procedure for measuring the absolute spectral responsivity of optical-fiber power meters and computation of the calibration uncertainty. The procedure reconciles measurement results associated with a monochromator-based measurement system with those obtained with laser sources coupled with optical fiber. Relative expanded uncertainties based on the methods from the Guide to the Expression of Uncertainty in Measurement and from Supplement 1 to the "Guide to the Expression of Uncertainty in Measurement"-Propagation of Distributions using a Monte Carlo Method are derived and compared. An example is used to illustrate the procedures and calculation of uncertainties.

4.
Appl Opt ; 47(18): 3360-3, 2008 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-18566634

RESUMO

A high-energy laser attenuator in the range of 250 mJ (20 ns pulse width, 10 Hz repetition rate, 1064 nm wavelength) is described. The optical elements that constitute the attenuator are mirrors with relatively low reflectance, oriented at a 45 degrees angle of incidence. By combining three pairs of mirrors, the incoming radiation is collinear and has the same polarization orientation as the exit. We present damage testing and polarization-dependent reflectance measurements for 1064 nm laser light at 45 degrees angle of incidence for molybdenum, silicon carbide, and copper mirrors. A six element, 74 times (18 dB) attenuator is presented as an example.

5.
Appl Opt ; 44(6): 841-8, 2005 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-15751672

RESUMO

We have developed a measurement system based on a correlation method to characterize the nonlinearity of a detector's response over a large range of laser pulse energy. The system consists of an excimer-laser source, beam-shaping optics, a beam splitter, a monitor detector, a set of optical filters, and the detector under test. Detector nonlinearities as large as 10% or greater over an entire measurement range at an excimer-laser wavelength of 193 nm are observed. The measurement range of the current system is approximately 300 nJ to 50 mJ of laser pulse energy at the detector under test. The typical expanded measurement uncertainty of nonlinearity is 0.6% (k = 2).

6.
J Res Natl Inst Stand Technol ; 109(4): 429-34, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-27366622

RESUMO

We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST nonlinearity measurement system, in which detector responsivity can be measured at wavelengths of 1.06 µm and 10.6 µm, over a power range from 1 W to 1000 W. We present the data processing method used and show measurement results depicting both positive and negative nonlinear behavior. The expanded uncertainty of a typical NIST high-power laser detector calibration including nonlinearity characterization is about 1.3 %.