Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Trends Biotechnol ; 42(5): 612-630, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38238246

RESUMO

3D printing technologies have the potential to revolutionize the manufacture of heart valves through the ability to create bespoke, complex constructs. In light of recent technological advances, we review the progress made towards 3D printing of heart valves, focusing on studies that have utilised these technologies beyond manufacturing patient-specific moulds. We first overview the key requirements of a heart valve to assess functionality. We then present the 3D printing technologies used to engineer heart valves. By referencing International Organisation for Standardisation (ISO) Standard 5840 (Cardiovascular implants - Cardiac valve prostheses), we provide insight into the achieved functionality of these valves. Overall, 3D printing promises to have a significant positive impact on the creation of artificial heart valves and potentially unlock full complex functionality.


Assuntos
Próteses Valvulares Cardíacas , Impressão Tridimensional , Humanos , Valvas Cardíacas , Desenho de Prótese/métodos , Engenharia Tecidual/métodos
2.
NPJ Microgravity ; 10(1): 7, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218868

RESUMO

We investigated variations in haemodynamics in response to simulated microgravity across a semi-subject-specific three-dimensional (3D) continuous arterial network connecting the heart to the eye using computational fluid dynamics (CFD) simulations. Using this model we simulated pulsatile blood flow in an upright Earth gravity case and a simulated microgravity case. Under simulated microgravity, regional time-averaged wall shear stress (TAWSS) increased and oscillatory shear index (OSI) decreased in upper body arteries, whilst the opposite was observed in the lower body. Between cases, uniform changes in TAWSS and OSI were found in the retina across diameters. This work demonstrates that 3D CFD simulations can be performed across continuously connected networks of small and large arteries. Simulated results exhibited similarities to low dimensional spaceflight simulations and measured data-specifically that blood flow and shear stress decrease towards the lower limbs and increase towards the cerebrovasculature and eyes in response to simulated microgravity, relative to an upright position in Earth gravity.

3.
Biomech Model Mechanobiol ; 23(1): 255-269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37805938

RESUMO

Cerebrovascular haemodynamics are sensitive to multiple physiological stimuli that require synergistic response to maintain adequate perfusion. Understanding haemodynamic changes within cerebral arteries is important to inform how the brain regulates perfusion; however, methods for direct measurement of cerebral haemodynamics in these environments are challenging. The aim of this study was to assess velocity waveform metrics obtained using transcranial Doppler (TCD) with flow-conserving subject-specific three-dimensional (3D) simulations using computational fluid dynamics (CFD). Twelve healthy participants underwent head and neck imaging with 3 T magnetic resonance angiography. Velocity waveforms in the middle cerebral artery were measured with TCD ultrasound, while diameter and velocity were measured using duplex ultrasound in the internal carotid and vertebral arteries to calculate incoming cerebral flow at rest, during hypercapnia and exercise. CFD simulations were developed for each condition, with velocity waveform metrics extracted in the same insonation region as TCD. Exposure to stimuli induced significant changes in cardiorespiratory measures across all participants. Measured absolute TCD velocities were significantly higher than those calculated from CFD (P range < 0.001-0.004), and these data were not correlated across conditions (r range 0.030-0.377, P range 0.227-0.925). However, relative changes in systolic and time-averaged velocity from resting levels exhibited significant positive correlations when the distinct techniques were compared (r range 0.577-0.770, P range 0.003-0.049). Our data indicate that while absolute measures of cerebral velocity differ between TCD and 3D CFD simulation, physiological changes from resting levels in systolic and time-averaged velocity are significantly correlated between techniques.


Assuntos
Artérias Cerebrais , Hidrodinâmica , Humanos , Artérias Cerebrais/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia
4.
Ann Vasc Surg ; 98: 155-163, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37805169

RESUMO

BACKGROUND: The stent-assisted balloon-induced intimal disruption and relamination (STABILISE) technique for treatment of type B dissection has shown promising clinical results at mid-term. Computational modeling is a way of noninvasively obtaining hemodynamic effects, such as pressure and wall shear stress, leading to a better understanding of potential benefits. Particular areas of interest are (1) the effect of intimal disruption and re-lamination and (2) the effect of the bare metal stent in the visceral aortic segment. METHODS: Single-center prospective case series. Data from 5 consecutive locally performed cases of STABILISE technique were analyzed. Included cases were type B aortic dissection with or without prior de-branching. The STABILISE procedure had to be performed without 30-day major complications. Preoperative and postoperative imaging data for each patient were transferred to the biomedical engineering team. Each case was reconstructed, meshed, and simulated with computational fluid dynamics using patient-specific data (heart rate, blood pressure, height, and weight). Hemodynamic parameters were then extracted from the simulations. RESULTS: In all cases, computational analysis showed for postoperative patients: (1) a drop in pressure difference between lumina and (2) lower wall shear stress effects, compared to their preoperative status. These observations were most pronounced in the visceral aortic segment. CONCLUSIONS: Computational modeling shows favourable changes in the flow dynamics of type B dissection treated using the STABILISE technique. This may suggest protective effects of this technique for long-term aortic healing and cicatrization.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Resultado do Tratamento , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Stents , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Hemodinâmica , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia
5.
Mater Today Bio ; 22: 100778, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37664796

RESUMO

The interface tissue between bone and soft tissues, such as tendon and ligament (TL), is highly prone to injury. Although different biomaterials have been developed for TL regeneration, few address the challenges of the TL-bone interface. Here, we aim to develop novel hybrid nanocomposites based on poly(p-dioxanone) (PDO), poly(lactide-co-caprolactone) (LCL), and hydroxyapatite (HA) nanoparticles suitable for TL-bone interface repair. Nanocomposites, containing 3-10% of both unmodified and chemically modified hydroxyapatite (mHA) with a silane coupling agent. We then explored biocompatibility through in vitro and in vivo studies using a subcutaneous mouse model. Through different characterisation tests, we found that mHA increases tensile properties, creates rougher surfaces, and reduces crystallinity and hydrophilicity. Morphological observations indicate that mHA nanoparticles are attracted by PDO rather than LCL phase, resulting in a higher degradation rate for mHA group. We found that adding the 5% of nanoparticles gives a balance between the properties. In vitro experiments show that osteoblasts' activities are more affected by increasing the nanoparticle content compared with fibroblasts. Animal studies indicate that both HA and mHA nanoparticles (10%) can reduce the expression of pro-inflammatory cytokines after six weeks of implantation. In summary, this work highlights the potential of PDO/LCL/HA nanocomposites as an excellent biomaterial for TL-bone interface tissue engineering applications.

6.
Transfusion ; 63 Suppl 3: S105-S111, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37057621

RESUMO

BACKGROUND: New blood products are considered for treatment of patients with major hemorrhage. The aim of this report is to describe the current transfusion practices in Europe for patients with major hemorrhage and explore the need for new or modified blood products to ensure prehospital and in-hospital blood supply. STUDY DESIGN AND METHOD: The European Blood Alliance (EBA) Working Group on Innovation and New Blood Products' subgroup on major hemorrhage performed a survey among the EBA member states. RESULTS: The response rate was 58% (17 responses from 15 of the 26 EBA member states). Of these, sixteen (94%) provide massive transfusion packages (MTPs) with balanced ratio of red blood cells and plasma. Seven of the respondents included platelets from the start of treatment. Eleven (65%) provide prehospital blood products, mainly red cell concentrates or dried and/or thawed plasma with 5 days of extended storage. Two countries provide prehospital whole blood. Twelve respondents (71%) saw a need for implementation of new or modified blood components in their institution. The top three priorities were whole blood (12 of 12, 100%), dried plasma (8 of 12, 67%), and cold-stored platelets (7 of 12, 58%). DISCUSSION: Current national guidelines for use of blood products in patients with major hemorrhage in Europe agree on the use of balanced transfusion, however the timing and source of platelets differ. Blood products for prehospital transfusion are available in several European countries. An interest in new or modified blood products for patients with major hemorrhage was observed, especially for whole blood.


Assuntos
Transfusão de Sangue , Hemorragia , Humanos , Hemorragia/terapia , Transfusão de Componentes Sanguíneos , Plaquetas , Europa (Continente)
7.
Bioact Mater ; 25: 291-306, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36844365

RESUMO

Biopolymers play a critical role as scaffolds used in tendon and ligament (TL) regeneration. Although advanced biopolymer materials have been proposed with optimised mechanical properties, biocompatibility, degradation, and processability, it is still challenging to find the right balance between these properties. Here, we aim to develop novel hybrid biocomposites based on poly(p-dioxanone) (PDO), poly(lactide-co-caprolactone) (LCL) and silk to produce high-performance grafts suitable for TL tissue repair. Biocomposites containing 1-15% of silk were studied through a range of characterisation techniques. We then explored biocompatibility through in vitro and in vivo studies using a mouse model. We found that adding up to 5% silk increases the tensile properties, degradation rate and miscibility between PDO and LCL phases without agglomeration of silk inside the composites. Furthermore, addition of silk increases surface roughness and hydrophilicity. In vitro experiments show that the silk improved attachment of tendon-derived stem cells and proliferation over 72 h, while in vivo studies indicate that the silk can reduce the expression of pro-inflammatory cytokines after six weeks of implantation. Finally, we selected a promising biocomposite and created a prototype TL graft based on extruded fibres. We found that the tensile properties of both individual fibres and braided grafts could be suitable for anterior cruciate ligament (ACL) repair applications.

8.
Bioact Mater ; 19: 179-197, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35510172

RESUMO

Tendon and ligament (TL) injuries affect millions of people annually. Biopolymers play a significant role in TL tissue repair, whether the treatment relies on tissue engineering strategies or using artificial tendon grafts. The biopolymer governs the mechanical properties, biocompatibility, degradation, and fabrication method of the TL scaffold. Many natural, synthetic and hybrid biopolymers have been studied in TL regeneration, often combined with therapeutic agents and minerals to engineer novel scaffold systems. However, most of the advanced biopolymers have not advanced to clinical use yet. Here, we aim to review recent biopolymers and discuss their features for TL tissue engineering. After introducing the properties of the native tissue, we discuss different types of natural, synthetic and hybrid biopolymers used in TL tissue engineering. Then, we review biopolymers used in commercial absorbable and non-absorbable TL grafts. Finally, we explain the challenges and future directions for the development of novel biopolymers in TL regenerative treatment.

10.
J Vasc Access ; : 11297298221127760, 2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36281219

RESUMO

BACKGROUND: Peripheral intravenous catheters (PIVCs) are the most commonly used invasive medical device, yet despite best efforts by end-users, PIVCs experience unacceptably high early failure rates. We aimed to design a new PIVC that reduces the early failure rate of in-dwelling PIVCs and we conducted preliminary tests to assess its efficacy and safety in a porcine model of intravenous access. METHODS: We used computer-aided design and simulation to create a PIVC with a ramped tip geometry, which directs the infused fluid away from the vein wall; we called the design the FloRamp™. We created FloRamp prototypes (test device) and tested them against a market-leading device (BD Insyte™; control device) in a highly-controlled setting with five insertion sites per device in four pigs. We measured resistance to infusion and visual infusion phlebitis (VIP) every 6 h and terminated the experiment at 48 h. Veins were harvested for histology and seven pathological markers were assessed. RESULTS: Computer simulations showed that the optimum FloRamp tip reduced maximum endothelial shear stress by 60%, from 12.7 Pa to 5.1 Pa, compared to a typical PIVC tip and improved the infusion dynamics of saline in the blood stream. In the animal study, we found that 2/5 of the control devices were occluded after 24 h, whereas all test devices remained patent and functional. The FloRamp created less resistance to infusion (0.73 ± 0.81 vs 0.47 ± 0.50, p = 0.06) and lower VIP scores (0.60 ± 0.93 vs 0.31 ± 0.70, p = 0.09) than the control device, although neither findings were significantly different. Histopathology revealed that 5/7 of the assessed markers were lower in veins with the FloRamp. CONCLUSIONS: Herein we report preliminary assessment of a novel PIVC design, which could be advantageous in clinical settings through decreased device occlusion and reduced early failure rates.

11.
Adv Healthc Mater ; 11(24): e2201028, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36300603

RESUMO

Interfaces within biological tissues not only connect different regions but also contribute to the overall functionality of the tissue. This is especially true in the case of the aortic heart valve. Here, melt electrowriting (MEW) is used to engineer complex, user-defined, interfaces for heart valve scaffolds. First, a multi-modal imaging investigation into the interfacial regions of the valve reveals differences in collagen orientation, density, and recruitment in previously unexplored regions including the commissure and inter-leaflet triangle. Overlapping, suturing, and continuous printing methods for interfacing MEW scaffolds are then investigated for their morphological, tensile, and flexural properties, demonstrating the superior performance of continuous interfaces. G-codes for MEW scaffolds with complex interfaces are designed and generated using a novel software and graphical user interface. Finally, a singular MEW scaffold for the interfacial region of the aortic heart valve is presented incorporating continuous interfaces, gradient porosities, variable layer numbers across regions, and tailored fiber orientations inspired by the collagen distribution and orientation from the multi-modal imaging study. The scaffold exhibits similar yield strain, hysteresis, and relaxation behavior to porcine heart valves. This work demonstrates the ability of a bioinspired approach for MEW scaffold design to address the functional complexity of biological tissues.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Animais , Suínos , Engenharia Tecidual/métodos , Biomimética/métodos , Valvas Cardíacas , Colágeno , Imagem Multimodal
13.
Adv Healthc Mater ; 11(13): e2200271, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35481675

RESUMO

Endovascular treatment of aortic disorders has gained wide acceptance due to reduced physiological burden to the patient compared to open surgery, and ongoing stent-graft evolution has made aortic repair an option for patients with more complex anatomies. To date, commercial stent-grafts are typically developed from established production techniques with simple design structures and limited material ranges. Despite the numerous updated versions of stent-grafts by manufacturers, the reoccurrence of device-related complications raises questions about whether the current manfacturing methods are technically able to eliminate these problems. The technology trend to produce efficient medical devices, including stent-grafts and all similar implants, should eventually change direction to advanced manufacturing techniques. It is expected that through recent advancements, especially the emergence of 4D-printing and smart materials, unprecedented features can be defined for cardiovascular medical implants, like shape change and remote battery-free self-monitoring. 4D-printing technology promises adaptive functionality, a highly desirable feature enabling printed cardiovascular implants to physically transform with time to perform a programmed task. This review provides a thorough assessment of the established technologies for existing stent-grafts and provides technical commentaries on known failure modes. They then discuss the future of advanced technologies and the efforts needed to produce next-generation endovascular implants.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Prótese Vascular , Humanos , Desenho de Prótese , Stents , Resultado do Tratamento
14.
Cardiovasc Eng Technol ; 13(6): 816-828, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35419664

RESUMO

PURPOSE: Arterial shear forces may promote the embolization of clotted blood from the surface of thrombi, displacing particles that may occlude vasculature, with increased risk of physiological complications and mortality. Thromboemboli may also collide in vivo to form metastable aggregates that increase vessel occlusion likelihood. METHODS: A micromechanical force (MMF) apparatus was modified for aqueous applications to study clot-liquid interfacial phenomena between clotted porcine blood particles suspended in modified continuous phases. The MMF measurement is based on visual observation of particle-particle separation, where Hooke's Law is applied to calculate separation force. This technique has previously been deployed to study solid-fluid interfacial phenomena in oil and gas pipelines, providing fundamental insight to cohesive and adhesive properties between solids in multiphase flow systems. RESULTS: This manuscript introduces distributed inter-particle separation force properties as a function of governing physio-chemical parameters; pre-load (contact) force, contact time, and bulk phase chemical modification. In each experimental campaign, the hysteresis and distributed force properties were analysed, to derive insight as to the governing mechanism of cohesion between particles. Porcine serum, porcine albumin and pharmaceutical agents (alteplase, tranexamic acid and hydrolysed aspirin) reduced the measurement by an order of magnitude from the baseline measurement-the apparatus provides a platform to study how surface-active chemistries impact the solid-fluid interface. CONCLUSION: These results provide new insight to potential mechanisms of macroscopic thromboembolic aggregation via particles cohering in the vascular system-data that can be directly applied to computational simulations to predict particle fate, better informing the mechanistic developments of embolic occlusion.


Assuntos
Água , Suínos , Animais , Tamanho da Partícula , Água/química
15.
Vox Sang ; 117(6): 796-802, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35157317

RESUMO

BACKGROUND AND OBJECTIVES: Di(2-ethylhexyl) phthalate (DEHP) must be removed from blood bag sets in Europe by 27 May 2025. DEHP is known to interact with the red blood cell (RBC) membrane, resulting in reduced haemolysis and thus prolonging shelf-life. Current non-DEHP alternatives result in increased haemolysis requiring reconsideration of the RBC shelf-life. Although the immediate impact of eliminating DEHP is to the European community, the non-DEHP movement could affect blood bag set availability globally. The purpose of this survey is to understand blood centre readiness regarding the transition to non-DEHP blood collection and storage systems. MATERIALS AND METHODS: A 24-question on-line survey was completed by members of the Biomedical Excellence for Safer Transfusion Collaborative research network. RESULTS: Responses were obtained from 16 blood collection or processing institutions. A majority of respondents (12/16) indicated that both shelf-life and haemolysis were equally important in selecting non-DEHP blood bag sets. Six respondents would accept a lower RBC product shelf-life compared to current practice. Respondents were not clear on the best non-DEHP vinyl material or RBC storage solution. Three European blood centres indicated they have developed non-DEHP transition plans. One challenge identified regarding the transition to non-DEHP is the extensive validation testing that will be required. CONCLUSION: Blood centres in Europe are concerned with meeting the sunset date for DEHP, considering that limited non-DEHP blood bag and RBC storage solutions are currently available. Banning DEHP in Europe, which may have global ramifications, represents a major challenge not yet fully understood by the transfusion medicine community.


Assuntos
Dietilexilftalato , Preservação de Sangue/métodos , Hemólise , Humanos , Plastificantes , Inquéritos e Questionários
16.
J Vasc Surg ; 75(4): 1181-1190.e5, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34742883

RESUMO

BACKGROUND: Improved risk stratification is a key priority for type B aortic dissection (TBAD). Partial false lumen thrombus morphology is an emerging predictor of complications. However, partial thrombosis is poorly defined, and its evaluation in clinical studies has been inconsistent. Thus, we aimed to characterize the hemodynamic pressure in TBAD and determine how the pressure relates to the false lumen thrombus morphology and clinical events. METHODS: The retrospective admission computed tomography angiograms of 69 patients with acute TBAD were used to construct three-dimensional computational models for simulation of cyclical blood flow and calculation of pressure. The patients were categorized by the false lumen thrombus morphology as minimal, extensive, proximal or distal thrombosis. Linear regression analysis was used to compare the luminal pressure difference between the true and false lumen for each morphology group. The effect of morphology classification on the incidence of acute complications within 14 days was studied using logistic regression adjusted for clinical parameters. A survival analysis for adverse aortic events at 1 year was also performed using Cox regression. RESULTS: Of the 69 patients, 44 had experienced acute complications and 45 had had an adverse aortic event at 1 year. The mean ± standard deviation age was 62.6 ± 12.6 years, and 75.4% were men. Compared with the patients with minimal thrombosis, those with proximal thrombosis had a reduced false lumen pressure by 10.1 mm Hg (95% confidence interval [CI], 4.3-15.9 mm Hg; P = .001). The patients who had not experienced an acute complication had had a reduced relative false lumen pressure (-6.35 mm Hg vs -0.62 mm Hg; P = .03). Proximal thrombosis was associated with fewer acute complications (odds ratio, 0.17; 95% CI, 0.04-0.60; P = .01) and 1-year adverse aortic events (hazard ratio, 0.36; 95% CI, 0.16-0.80; P = .01). CONCLUSIONS: We found that proximal false lumen thrombosis was a marker of reduced false lumen pressure. This might explain how proximal false lumen thrombosis appears to be protective of acute complications (eg, refractory hypertension or pain, aortic rupture, visceral or limb malperfusion, acute expansion) and adverse aortic events within the first year.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose , Idoso , Aorta , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/complicações , Trombose/etiologia , Resultado do Tratamento
17.
Circ Cardiovasc Imaging ; 14(12): 1112-1121, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34875845

RESUMO

BACKGROUND: Low shear stress has been implicated in abdominal aortic aneurysm (AAA) expansion and clinical events. We tested the hypothesis that low shear stress in AAA at baseline is a marker of expansion rate and future aneurysm-related events. METHODS: Patients were imaged with computed tomography angiography at baseline and followed up every 6 months >24 months with ultrasound measurements of maximum diameter. From baseline computed tomography angiography, we reconstructed 3-dimensional models for automated computational fluid dynamics simulations and computed luminal shear stress. The primary composite end point was aneurysm repair and/or rupture, and the secondary end point was aneurysm expansion rate. RESULTS: We included 295 patients with median AAA diameter of 49 mm (interquartile range, 43-54 mm) and median follow-up of 914 (interquartile range, 670-1112) days. There were 114 (39%) aneurysm-related events, with 13 AAA ruptures and 98 repairs (one rupture was repaired). Patients with low shear stress (<0.4 Pa) experienced a higher number of aneurysm-related events (44%) compared with medium (0.4-0.6 Pa; 27%) and high (>0.6 Pa; 29%) shear stress groups (P=0.010). This association was independent of known risk factors (adjusted hazard ratio, 1.72 [95% CI, 1.08-2.73]; P=0.023). Low shear stress was also independently associated with AAA expansion rate (ß=+0.28 mm/y [95% CI, 0.02-0.53]; P=0.037). CONCLUSIONS: We show for the first time that low shear stress (<0.4 Pa) at baseline is associated with both AAA expansion and future aneurysm-related events. Aneurysms within the lowest tertile of shear stress, versus those with higher shear stress, were more likely to rupture or reach thresholds for elective repair. Larger prospective validation trials are needed to confirm these findings and translate them into clinical management.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/etiologia , Ruptura Aórtica/fisiopatologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Estresse Mecânico
20.
J Endovasc Ther ; 28(4): 623-635, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34076554

RESUMO

PURPOSE: To compare the flow patterns and hemodynamics of the AFX stent-graft and the covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser particle image velocimetry (PIV) experiments. MATERIALS AND METHODS: Two anatomically realistic aortoiliac phantoms were constructed using polydimethylsiloxane polymer. An AFX stent-graft with a transparent cover made with a new method was inserted into one phantom. A CERAB configuration using Atrium's Avanta V12 with transparent covers made with a previously established method was inserted into the other phantom, both modified stent-grafts were suitable for laser PIV, enabling visualization of the flow fields and quantification of time average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). RESULTS: Disturbed flow was observed at the bifurcation region of the AFX, especially at the end systolic velocity (ESV) time-point where recirculation was noticeable due to vortical flow. In contrast, predominantly unidirectional flow was observed at the CERAB bifurcation. These observations were confirmed by the quantified hemodynamic results from PIV analysis where mean TAWSS of 0.078 Pa (range: 0.009-0.242 Pa) was significantly lower in AFX as compared with 0.229 Pa (range: 0.013-0.906 Pa) for CERAB (p<0.001). Mean OSI of 0.318 (range: 0.123-0.496) in AFX was significantly higher than 0.252 (range: 0.055-0.472) in CERAB (p<0.001). Likewise, mean RRT of 180 Pa-1 (range: 9-3603 Pa-1) in AFX was also significantly higher than 88 Pa-1 (range: 2-840 Pa-1) in CERAB (p=0.0086). CONCLUSION: In this in vitro study, the flow pattern of a modified AFX stent-graft was found to be more disturbed especially at the end systolic phase, its hemodynamic outcomes less desirable than CERAB configuration. CLINICAL RELEVANCE: While the AFX stent-graft has an advantage over the CERAB configuration in eliminating radial mismatch, and maintaining the anatomical bifurcation for future endovascular intervention, this in vitro study revealed that the associated lower TAWSS, higher OSI and RRT may predispose to thrombosis and are, thus, less desirable as compared to a CERAB configuration. Further investigation is warranted to confirm whether these findings translate into the clinical setting.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Desenho de Prótese , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS