Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Infect Control ; 44(7): 815-9, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-26952038

RESUMO

BACKGROUND: Experts have recommended microbiologic surveillance by external reference laboratories for certain flexible endoscopes. There is currently insufficient evidence on the feasibility and utility of cultures. Researchers evaluated a preassembled toolkit for collecting and processing samples from endoscopes. METHODS: A pilot study was performed in a large academic medical center. A toolkit was used to aseptically sample biopsy ports and suction/biopsy channels of 5 gastroscopes, 5 colonoscopes, and 5 bronchoscopes after full reprocessing. Blinded specimens were packaged and transported on icepacks to a reference laboratory that used standard methodologies for microbial cultures. RESULTS: The laboratory detected bacteria in samples from 60% of patient-ready endoscopes, including gram-positive and gram-negative species. Viable microbes (<10 CFU) were recovered from 2 gastroscopes, 3 colonoscopes, and 4 bronchoscopes. Stenotrophomonas maltophilia and Delftia acidovorans were recovered from all 3 endoscope types. Subsequent environmental testing detected S maltophilia in the reprocessing rinse water. CONCLUSIONS: A preassembled toolkit facilitated the aseptic collection of samples for culturing by a reference laboratory that detected viable microbes on fully reprocessed endoscopes. Speciation allowed identification of potential pathogens and a possible common contamination source, demonstrating that microbial cultures may have value even when colony counts are low.


Assuntos
Bactérias/isolamento & purificação , Broncoscópios/microbiologia , Colonoscópios/microbiologia , Reutilização de Equipamento , Gastroscópios/microbiologia , Esterilização/métodos , Centros Médicos Acadêmicos , Técnicas Bacteriológicas , Projetos Piloto
2.
Am J Infect Control ; 43(8): 794-801, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26234219

RESUMO

BACKGROUND: Pathogens have been transmitted via flexible endoscopes that were reportedly reprocessed in accordance with guidelines. METHODS: Researchers observed reprocessing activities to ensure guideline compliance in a large gastrointestinal endoscopy unit. Contamination was assessed immediately after bedside cleaning, manual cleaning, high-level disinfection, and overnight storage via visual inspection, aerobic cultures, and tests for adenosine triphosphate (ATP), protein, carbohydrate, and hemoglobin. RESULTS: All colonoscopes and gastroscopes were reprocessed in accordance with guidelines during the study. Researchers collected and tested samples during 60 encounters with 15 endoscopes. Viable microbes were recovered from bedside-cleaned (92%), manually cleaned (46%), high-level disinfected (64%), and stored (9%) endoscopes. Rapid indicator tests detected contamination (protein, carbohydrate, hemoglobin, or ATP) above benchmarks on bedside-cleaned (100%), manually cleaned (92%), high-level disinfected (73%), and stored (82%) endoscopes. Visible residue was never observed on endoscopes, but it was often seen on materials used to sample endoscopes. Seven endoscopes underwent additional reprocessing in response to positive rapid indicators. Control endoscope channels were free of biologic residue and viable microbes. CONCLUSION: Despite reprocessing in accordance with US guidelines, viable microbes and biologic debris persisted on clinically used gastrointestinal endoscopes, suggesting current reprocessing guidelines are not sufficient to ensure successful decontamination.


Assuntos
Colonoscópios/microbiologia , Descontaminação , Desinfecção/métodos , Gastroscópios/microbiologia , Fidelidade a Diretrizes , Controle de Infecções/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...