Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Mol Genet Genomics ; 269(2): 173-9, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12756529

RESUMO

An improved cDNA-AFLP method for genome-wide expression analysis has been developed. We demonstrate that this method is an efficient tool for quantitative transcript profiling and a valid alternative to microarrays. Unique transcript tags, generated from reverse-transcribed messenger RNA by restriction enzymes, were screened through a series of selective PCR amplifications. Based on in silico analysis, an enzyme combination was chosen that ensures that at least 60% of all the mRNAs were represented by an informative sequence tag. The sensitivity and specificity of the method allows one to detect poorly expressed genes and distinguish between homologous sequences. Accurate gene expression profiles were determined by quantitative analysis of band intensities, and subtle differences in transcriptional activity were revealed. A detailed screen for cell cycle-modulated genes in tobacco demonstrates the usefulness of the technology for genome-wide expression analysis.


Assuntos
Técnicas Genéticas , Genoma , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Polimorfismo Genético , Sequência de Bases , Primers do DNA/farmacologia , DNA Complementar/metabolismo , Modelos Genéticos , Dados de Sequência Molecular , Reação em Cadeia da Polimerase , RNA/metabolismo , RNA Mensageiro/metabolismo , Nicotiana/genética
3.
J Vasc Interv Radiol ; 12(9): 1075-85, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11535771

RESUMO

PURPOSE: To test the effect of temporary caval filtration on pulmonary emboli when a mechanical thrombolytic device is used to treat venous thrombosis and to test the effects of a modified device on caval patency at 30-day follow-up. MATERIALS AND METHODS: In a canine model of iliocaval subacute thrombosis, mechanical thrombolysis was performed with use of an 8-F over-the-wire Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with a 9-mm (iliac) or 15-mm (inferior vena cava [IVC]) basket. In six procedures, the device was made of nitinol monofilament, and in another six, it was made of braided stainless steel. All procedures were performed with a nitinol expandable sheath (temporary filter) in the suprarenal IVC. Low-molecular-weight heparin was given daily after the procedure. Venography, pulmonary arteriography, measurement of blood gases, and pulmonary artery (PA) pressure measurement were performed before and after the procedure and at 30-day follow-up. Pulmonary arteriograms from the group treated with stainless-steel devices were compared to those from an earlier group of animals in which the identical procedure was performed without caval filtration. The IVC was examined histologically. RESULTS: Thrombolysis was successful in all animals. Rare segmental and subsegmental pulmonary emboli (PE) were seen arteriographically; compared to procedures without filters, there was a significant reduction in PE (P <.002). However, a mild increase in pulmonary artery pressure, decrease in pH, and increase in pCO(2) were observed postprocedurally. At 30-day follow-up (n = 11), IVC patency was preserved in 45% (n = 5) of animals overall. Caval patency was significantly better in animals in which the combination of stainless-steel devices was used (five of six = 83% vs zero with nitinol device; P =.015). Histologically, the stainless-steel device caused little intimal injury and fibrosis-less than that seen with the nitinol device. CONCLUSIONS: Temporary filtration reduces, but does not completely eliminate, PE during mechanical thrombolysis. The stainless-steel device results in less intimal injury and better caval patency than the nitinol device.


Assuntos
Filtros de Veia Cava , Trombose Venosa/terapia , Animais , Gasometria , Modelos Animais de Doenças , Cães , Desenho de Equipamento , Seguimentos , Embolia Pulmonar/prevenção & controle , Radiografia , Veia Cava Inferior/patologia , Trombose Venosa/diagnóstico por imagem
4.
J Vasc Interv Radiol ; 12(8): 969-77, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11487678

RESUMO

PURPOSE: To create a porcine hemodialysis access model that reliably reproduces intimal hyperplasia (IH) of the outflow vein similar to that which causes access failure in human patients undergoing dialysis treatments. MATERIALS AND METHODS: Surgical technique for creation of side-to-side iliac-artery-to-ipsilateral-iliac-vein (IAV) native fistulas and IAV conduits was optimized in three standard-bred pigs. Persistent patency of fistulas and conduits was demonstrated in two additional pigs allowed to survive for 1 week. IAV fistulas and contralateral 2-cm polytetrafluoroethylene IAV conduits were created in five additional pigs. Venous outflow from these fistulas and conduits was evaluated with venography and intravascular ultrasound (IVUS) immediately after creation (day 0) and at 2-week intervals for as long as 64 days. Animals were killed at 30 days (n = 1), 42 days (n = 2), or 64 days (n = 2), and the arteries, veins, and conduits were evaluated histologically. RESULTS: IAV native fistulas remained patent until the animals' death and conduits remained patent for at least 14 days in four of five pigs; both the fistula and conduit likely occluded before 16-day follow-up in the fifth pig. At 42-64 days, venography demonstrated maximum fistula outflow vein diameter stenoses of 53%-76% and maximum conduit outflow vein stenoses of 44%-84%, and IVUS demonstrated maximum area stenoses of 64%-86% and 43%-82%, respectively. Three of five conduits occluded, one before 16-day follow-up, one between 14 and 28 days, and the other after 42 days. Histologic sections demonstrated IH predominantly affecting the veins at the anastomoses and central (cephalad) to the anastomoses in all pigs. CONCLUSION: This porcine model reproduces IH in the fistula or conduit outflow vein with measurable stenosis. Such a model might allow relevant preclinical evaluation of interventional devices and techniques intended to reduce the effects of IH in human patients undergoing dialysis treatments.


Assuntos
Derivação Arteriovenosa Cirúrgica , Modelos Animais de Doenças , Diálise Renal/efeitos adversos , Suínos , Túnica Íntima/patologia , Animais , Feminino , Hiperplasia/etiologia , Hiperplasia/patologia , Artéria Ilíaca/cirurgia , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/cirurgia , Radiografia , Diálise Renal/instrumentação , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção
5.
Acad Radiol ; 8(6): 473-7, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11394539

RESUMO

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate the mortality and morbidity associated with a simple technique for inducing diabetes in dogs--suprarenal intraarterial infusion of alloxan and streptozotocin during balloon occlusion of the juxtarenal abdominal aorta. MATERIALS AND METHODS: The authors attempted to induce diabetes in six purpose-bred dogs. After the dogs were fasted for 12 hours, the abdominal aorta at the level of the origin of the renal arteries was occluded with an angioplasty balloon introduced by means of a femoral approach. A 3-F microcatheter (n = 1) or infusion wire (n = 5) was introduced via the percutaneous transluminal angioplasty catheter and positioned at the level of the celiac axis, and a mixture of streptozotocin (20-25 mg/kg) and alloxan (20-25 mg/kg) was infused. Diabetes was considered to have been induced if the dogs experienced sustained hyperglycemia. RESULTS: There were no deaths during the follow-up period (range, 7 months to 2 1/2 years). A diabetes-like state was induced in five of the six dogs, and no nephrotoxicity was seen. Diabetes was not induced in one dog owing to caudal migration of an undersized balloon during the infusion; this also resulted in reversible renal damage. CONCLUSION: This simple technique is effective for inducing diabetes in dogs, and morbidity and mortality rates are lower than those reported in the literature with other described techniques.


Assuntos
Aloxano/administração & dosagem , Aorta Abdominal/fisiologia , Oclusão com Balão , Diabetes Mellitus Experimental/induzido quimicamente , Infusões Intra-Arteriais/métodos , Estreptozocina/administração & dosagem , Animais , Diabetes Mellitus Experimental/mortalidade , Cães , Feminino
6.
J Vasc Interv Radiol ; 12(2): 227-34, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11265888

RESUMO

PURPOSE: To determine the safety and short-term patency of a polytetrafluoroethylene (PTFE)-encapsulated carbon-lined endoluminal device (ED) deployed across the venous anastomosis of arteriovenous conduits. MATERIALS AND METHODS: Arteriovenous grafts (n = 16) were created between femoral arteries and veins in eight female canines and allowed to mature 30 days +/- 5 (SD). Five were excluded before implantation because of thrombosis or intragraft stenosis. Deployment was conducted in the remaining 11 anastomoses. Fistulography and intravascular ultrasound (IVUS) were performed before and after the procedure and 1 month postimplantation. Stent migration, apposition, and stenosis were evaluated. The angle of the anastomosis was compared before and after deployment and at follow-up. Mural thrombus thickness, percentage of surface covering, and percentage of endothelialization within the device were measured histologically. RESULTS: There was no significant migration. By explant, all devices were completely apposed. Stenosis occurred in three of nine grafts. The angle of the venous anastomosis decreased by 29.5 degrees (posteroanterior) and 32.4 degrees (oblique) after ED deployment. There was a further decrease of 6.1 degrees (posteroanterior) and 3.2 degrees (oblique) during the 4-week follow-up period. Hemostasis was difficult to achieve in this animal model. Five required more than 1 hour to achieve hemostasis manually. Six in three animals were closed with a Perclose device, achieving immediate hemostasis; however, three (one in each animal) re-bled intermittently 2 weeks after implantation for an average of 9.3 days. The puncture site of each graft that bled was radiographically shown abnormal. CONCLUSION: The ED can be deployed without stent migration and is completely apposed and patent after 4 weeks. Although bleeding was a problem with this animal model, delayed bleeding complications associated with puncture site abnormalities were seen only in grafts closed with a percutaneous suturing device.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Oclusão de Enxerto Vascular , Politetrafluoretileno , Stents , Animais , Cães , Feminino , Artéria Femoral/cirurgia , Veia Femoral/cirurgia , Hemostasia , Fatores de Tempo , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
7.
J Bacteriol ; 182(20): 5832-40, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11004184

RESUMO

Rhodococcus fascians can interact with many plant species and induce the formation of either leafy galls or fasciations. To provoke symptoms, R. fascians strain D188 requires pathogenicity genes that are located on a linear plasmid, pFiD188. The fas genes are essential for virulence and constitute an operon that encodes, among other functions, a cytokinin synthase gene. Expression of the fas genes is induced by extracts of infected plant tissue only. We have isolated an AraC-type regulatory gene, fasR, located on pFiD188, which is indispensable for pathogenesis and for fas gene expression. The combined results of our experiments show that in vitro expression of the fas genes in a defined medium is strictly regulated and that several environmental factors (pH, carbon and nitrogen sources, phosphate and oxygen content, and cell density) and regulatory proteins are involved. We further show that expression of the fas genes is controlled at both the transcriptional and the translational levels. The complex expression pattern probably reflects the necessity of integrating a multitude of signals and underlines the importance of the fas operon in the pathogenicity of R. fascians.


Assuntos
Proteínas de Bactérias , Plantas/microbiologia , Rhodococcus/genética , Rhodococcus/patogenicidade , Fatores de Transcrição/genética , Virulência/genética , Sequência de Aminoácidos , Escherichia coli/genética , Deleção de Genes , Genes Reguladores , Dados de Sequência Molecular , Mutagênese , Fases de Leitura Aberta , Doenças das Plantas/microbiologia , Folhas de Planta/microbiologia , Plasmídeos , Mapeamento por Restrição , Alinhamento de Sequência , Homologia de Sequência de Aminoácidos , Fatores de Transcrição/química , Fatores de Transcrição/metabolismo
8.
J Vasc Interv Radiol ; 11(3): 382-90, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10735436

RESUMO

PURPOSE: To test the technical feasibility of creating a left ventricle to coronary sinus shunt using endovascular techniques. MATERIALS AND METHODS: By means of a right jugular vein approach, a needle puncture was made from the coronary sinus to the left ventricle in 10 dogs. The tracts were balloon dilated and lined with 6-mm Wallstents. Shunt patencies, immediate and 4-hours later, were fluoroscopically assessed by contrast material injection into the left ventricle. Blood pressure, pulse, oxygen saturation, and cardiac rhythm were monitored. The dogs were then euthanized. Thoracic cavities and hearts were dissected and inspected. RESULTS: Technical success and immediate shunt patency were 100%. No cardiac dysrhythmias, electrocardiographic changes, or reduction in voltage potential were seen. Eight (80%) of the shunts were patent at 4 hours, one (10%) had thrombosed, and one dog died. Nine (90%) dogs had no pericardial hematoma and one (10%) had minimal pericardial blood from needle passes into the pericardial sac. The coronary sinuses were intact and no injuries to the valve leaflets or chordae tendineae were seen. The puncture sites were from the coronary sinus, 1-2 mm (mean, 1.3) from its auricular orifice, into the left ventricle, just below the inferior margin of the posterior leaflet of the mitral valve. One dog died at 3 hours with no preceding electrocardiographic evidence of impending demise. Autopsy showed no pericardial hematoma and the heart findings were no different from the other nine dogs. CONCLUSIONS: Creation of a left ventricle to coronary sinus shunt with use of endovascular techniques is technically feasible. Study of a transmyocardial intracardiac coronary retroperfusion shunt to deliver oxygenated blood to the ischemic myocardium is warranted.


Assuntos
Vasos Coronários/cirurgia , Ventrículos do Coração/cirurgia , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica/métodos , Anastomose Cirúrgica , Animais , Angiografia Coronária , Modelos Animais de Doenças , Cães , Estudos de Viabilidade , Feminino , Isquemia Miocárdica/diagnóstico por imagem , Resultado do Tratamento
9.
J Vasc Interv Radiol ; 11(1): 115-22, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10693723

RESUMO

PURPOSE: To assess the feasibility of intravascular delivery of nadroparin, a low-molecular-weight heparin, via hydrogel-coated angioplasty balloons, and the effects of nadroparin delivered in this manner on platelet deposition and smooth muscle cell (SMC) proliferation. MATERIALS AND METHODS: Tritiated nadroparin was used to determine the nadroparin-carrying capacity of the hydrogel-coating, kinetics of release from the balloons, and, in four pigs, delivery of the nadroparin to the iliac arterial wall. Platelet deposition in nadroparin-treated iliac arteries versus contralateral iliac arteries dilated with saline-loaded, hydrogel-coated balloons was quantified in seven pigs using 111Indium-labeled platelets. Smooth muscle cell proliferation in nadroparin and saline-treated iliac arteries in 10 pigs was evaluated 7 days after angioplasty with use of proliferating cell nuclear antigen. RESULTS: Approximately 98 international units of nadroparin were delivered by the hydrogel-coated balloon, the majority to the angioplasty site and distal vessel. There was a trend toward decreased platelet deposition in nadroparin-treated arteries, but statistical significance was not achieved (P = .1563). Medial SMC proliferation was decreased in the nadroparin-treated arteries in nine of 10 pigs (P = .0137). CONCLUSIONS: Hydrogel-coated balloons may be used to deliver nadroparin to the arterial wall, with measurable levels of the drug delivered to the site of angioplasty, and with resultant decrease in SMC proliferation.


Assuntos
Angioplastia com Balão , Anticoagulantes/administração & dosagem , Hidrogel de Polietilenoglicol-Dimetacrilato , Músculo Liso Vascular/efeitos dos fármacos , Nadroparina/administração & dosagem , Adesividade Plaquetária/efeitos dos fármacos , Angioplastia com Balão/instrumentação , Animais , Divisão Celular/efeitos dos fármacos , Estudos de Viabilidade , Artéria Ilíaca/citologia , Artéria Ilíaca/efeitos dos fármacos , Músculo Liso Vascular/citologia , Suínos
10.
Radiology ; 212(3): 748-54, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10478242

RESUMO

PURPOSE: To determine whether gamma brachytherapy can prevent in-stent stenosis in hemodialysis grafts. MATERIALS AND METHODS: Six-millimeter polytetrafluoroethylene arteriovenous grafts were created bilaterally in six dogs. After 1 month, Wallstents spanning the venous anastomosis were placed to accelerate restenosis. Gamma irradiation (12 Gy) was delivered endoluminally to one of the two grafts by using an iridium 192 source; thus, each animal served as its own control. Fistulography was performed monthly for 10 months or until graft thrombosis, with measurement of stenosis at each time point. At the conclusion of the study period, the treated area was examined histologically, and a computer model was used to calculate the volume of intimal hyperplasia. RESULTS: Delayed stent migration resulted in exclusion of one dog. In the remaining five dogs; maximum stenosis across all time intervals was less for the treated side (P < .04), and the volume of intimal hyperplasia was less for the treated side (P < .045). In one animal studied at 1 year, this trend reversed in terms of percentage stenosis but not total neointimal volume. CONCLUSION: Brachytherapy with 192Ir (gamma) delivered at the time of stent placement reduces restenosis in this hemodialysis graft model, but, depending on the parameter evaluated (stenosis vs total volume of neointima), the benefit may wane or even reverse with time.


Assuntos
Derivação Arteriovenosa Cirúrgica , Braquiterapia , Oclusão de Enxerto Vascular/radioterapia , Diálise Renal , Angiografia , Animais , Prótese Vascular , Cães , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Veia Femoral/diagnóstico por imagem , Veia Femoral/cirurgia , Raios gama , Oclusão de Enxerto Vascular/diagnóstico por imagem , Politetrafluoretileno , Stents
11.
Invest Radiol ; 34(5): 336-40, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10226845

RESUMO

RATIONALE AND OBJECTIVES: Existing methods used to simulate pulmonary metastases are unsatisfactory. The aim of this study was to create a simple in vivo model of pulmonary metastases by endobronchial deployment of small high-density beads in anesthetized dogs. METHODS: Commercially available decorative beads measuring 2 and 4 mm in diameter and of high density (600 to 1200 Hounsfield units) were deployed in the peripheral airways of anesthetized dogs using catheter and guide wire manipulations through an endotracheal tube. RESULTS: A total of 65 beads were placed in five dogs. Computed tomography demonstrated that 41 (63%) were satisfactorily located in the lung periphery, 9 (14%) were unsatisfactorily located in large airways, and 15 (23%) were not visible. CONCLUSIONS: The endobronchial deployment of small high-density beads in the peripheral airways of anesthetized dogs is a novel and effective technique for creation of an in vivo model of pulmonary metastases.


Assuntos
Modelos Animais de Doenças , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Tomografia Computadorizada por Raios X , Animais , Cães , Feminino , Neoplasias Experimentais/diagnóstico por imagem , Neoplasias Experimentais/secundário , Projetos Piloto
12.
J Vasc Interv Radiol ; 7(5): 717-23, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8897341

RESUMO

PURPOSE: To establish the safety and efficacy of the Arrow Trerotola mechanical percutaneous thrombolytic device (PTD) for restoring patency of thrombosed hemodialysis grafts. MATERIALS AND METHODS: The hindlimb model of dialysis grafts was created in six dogs. Animals had either unilateral (n = 4) or bilateral (n = 2) polytetrafluoroethylene grafts, totaling eight grafts. Grafts were deliberately clotted 48 hours before thrombolysis. Thrombolysis was performed with five different versions of the PTD constructed of stainless steel (n = 12) or nitinol (n = 26) and rotated with use of a hand-held motor drive. After thrombolysis, fistulography was performed. RESULTS: Thirty-eight procedures were performed with the PTD, with 100% success. Thirty-day patency, evaluated in a subset of 15 procedures, was 100%. Complications included a single arterial embolus (2.6%) and eight device breakages (21%, all but two with the stainless steel version); none had any clinical consequences. A final modification of the nitinol device yielded 11 consecutive procedures without further breakage. No residual thrombus occurred in any procedure. Pathologic examination showed no significant injury to the vessels or neointima. CONCLUSION: The PTD is highly effective for mechanical thrombolysis in an animal model of clotted dialysis grafts. Based on this animal model, the device appears safe in its final modified form.


Assuntos
Trombectomia/instrumentação , Ligas , Animais , Derivação Arteriovenosa Cirúrgica/instrumentação , Prótese Vascular , Modelos Animais de Doenças , Cães , Embolia/etiologia , Desenho de Equipamento , Falha de Equipamento , Artéria Femoral/lesões , Artéria Femoral/patologia , Artéria Femoral/cirurgia , Veia Femoral/lesões , Veia Femoral/patologia , Veia Femoral/cirurgia , Teste de Materiais , Politetrafluoretileno , Diálise Renal/instrumentação , Rotação , Segurança , Aço Inoxidável , Trombectomia/efeitos adversos , Trombose/cirurgia , Resultado do Tratamento , Túnica Íntima/lesões , Túnica Íntima/patologia , Grau de Desobstrução Vascular
13.
Radiology ; 200(1): 169-76, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8657906

RESUMO

PURPOSE: To compare pulmonary emboli resulting from pulse-spray pharmacomechanical thrombolysis (PSPMT) and mechanical thrombolysis performed to declot dialysis-access grafts. MATERIALS AND METHODS: Polytetrafluoroethylene arteriovenous shunts were created in eight dogs and were deliberately clotted at monthly intervals. Animals were randomly assigned to treatment with pulse-spray urokinase thrombolysis or a low-speed rotational percutaneous thrombolytic device. Perfusion imaging, pulmonary-artery pressure measurements, and pulmonary arteriography were performed before and after each procedure. RESULTS: A total of 22 procedures were performed (11 PSPMT and 11 mechanical thrombolysis). Declotting was successful in all procedures, with 100% 30-day patency. Segmental defects were seen on perfusion images after 10 (91%) of 11 PSPMT procedures and two (18%) of 11 mechanical thrombolysis procedures (P < .002). Transient increases in pulmonary-artery pressure occurred in the PSPMT group. Complete resolution of emboli and return to baseline pressures were seen in all cases, even after multiple (up to four) procedures in the same animal. There was no histologic evidence of pulmonary infarction in either group. CONCLUSION: The percutaneous thrombolytic device is effective for declotting dialysis grafts in dogs and results in statistically significantly fewer pulmonary emboli compared with PSPMT.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Prótese Vascular/efeitos adversos , Embolia Pulmonar/etiologia , Diálise Renal , Trombectomia/efeitos adversos , Trombectomia/instrumentação , Terapia Trombolítica/efeitos adversos , Trombose/terapia , Animais , Pressão Sanguínea , Cães , Feminino , Politetrafluoretileno , Artéria Pulmonar , Embolia Pulmonar/induzido quimicamente , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/fisiopatologia , Troca Gasosa Pulmonar , Ativador de Plasminogênio Tipo Uroquinase/efeitos adversos
14.
J Vasc Interv Radiol ; 6(5): 675-81, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8541666

RESUMO

PURPOSE: To develop a technique of percutaneous creation and/or revision of arteriovenous hemodialysis access grafts, and to study the feasibility of the technique in the acute setting. MATERIALS AND METHODS: Arteriovenous shunts, consisting of silicone-covered Wallstents 6 (n = 10) or 8 (n = 1) mm in diameter and 11-17 cm in length, were created in 10 mongrel dogs. All shunts were created percutaneously except one, in which the carotid artery was exposed surgically and the jugular vein accessed percutaneously to create a straight external graft. All other grafts were femoral loops (femoral artery to femoral vein). Eight were tunneled subcutaneously and three were left external. All shunts were delivered through 10-F peel-away sheaths. RESULTS: The 11 shunts were allowed to flow for a mean of 4 hours (range, 1.0-6.5 hours) before the animals were killed. Leakage around the "anastomoses" was not observed. Leaks in the silicone covering were observed, resulting in one early shunt failure. Two attempted survival experiments were aborted due to early shunt dislodgment at 1.5 and 3.5 hours. CONCLUSIONS: Percutaneous arteriovenous shunt creation is feasible through acceptably small sheaths. Peel-away sheath placement of the stent circumvents the technical problem of placing a closed device into both artery and vein. This technique may allow percutaneous revision of existing hemodialysis access grafts and possibly de novo creation of grafts in humans, but modification of the grafts will be needed to prevent dislodgment.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Cateteres de Demora , Diálise Renal , Animais , Derivação Arteriovenosa Cirúrgica/instrumentação , Artérias Carótidas/cirurgia , Cães , Estudos de Viabilidade , Artéria Femoral/cirurgia , Veia Femoral/cirurgia , Veias Jugulares/cirurgia , Punções , Stents
15.
Radiology ; 194(3): 727-30, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7862970

RESUMO

PURPOSE: To quantitatively compare computed radiography (CR) and screen-film radiography (SFR) in the detection of pneumothorax in an animal model that simulates the neonate. MATERIALS AND METHODS: Three rabbits underwent placement of 5-F catheters in the right pleural space. Eight CR and eight SFR images were obtained. Volume-controlled pneumothorax was induced by incrementally injecting 4 cm3 of air (24 cm3 total) and four CR and four SFR images were obtained after each injection. Four radiologists blindly viewed the images twice (eight readings per image, 1,600 total observations). A dichotomous yes-no score for the presence of pneumothorax was used to calculate the volume detection threshold (VDT), defined as the air volume at which 50% of the pneumothoraces can be detected. The authors plotted the likelihood of a pneumothorax against the air volume by using the confidence indicator. RESULTS: Intraobserver VDT values for CR and SFR were not significantly different. CONCLUSION: CR is as accurate as SFR in the detection of pneumothorax in this quantitative animal model.


Assuntos
Pneumotórax/diagnóstico por imagem , Animais , Humanos , Recém-Nascido , Pneumotórax Artificial/métodos , Curva ROC , Coelhos , Intensificação de Imagem Radiográfica , Sensibilidade e Especificidade , Ecrans Intensificadores para Raios X
16.
Invest Radiol ; 29(5): 558-63, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8077096

RESUMO

RATIONALE AND OBJECTIVES: The feasibility of developing an animal model to simulate radiographic features of neonatal pneumothorax was investigated, and supine computed radiography (CR) and film-screen radiography (FS) images were compared. METHODS: 5-Fr pigtail catheters were inserted into the right pleural space of three New Zealand white rabbits. Two CR and two FS supine images were obtained using identical technique. After serial 4-mL injections of air, one CR and one FS supine image were obtained. The images were masked and randomized, and four radiologists reviewed the images for typical signs of pneumothorax. Chest computed tomography (CT) was performed before the injection of any air and after completion of the study. RESULTS: At zero-mL air volume, radiologists did not perceive a pneumothorax. As the air volume increased, the number of signs of a pneumothorax increased; there was no significant difference between CR and FS in the number of signs of pneumothorax detected at any volume. Chest CT confirmed that there was no unexplained air leak. The volume of air injected correlated with the calculated volume from the CT. CONCLUSIONS: This induced, volume-controlled, animal model simulated the supine radiographic features of neonatal pneumothorax.


Assuntos
Pneumotórax Artificial/métodos , Pneumotórax/diagnóstico por imagem , Animais , Estudos de Viabilidade , Humanos , Recém-Nascido , Coelhos , Intensificação de Imagem Radiográfica , Ecrans Intensificadores para Raios X
17.
Invest Radiol ; 28(3): 228-30, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8486489

RESUMO

RATIONALE AND OBJECTIVES: Bleeding is the most common complication of needle biopsy of the liver. This study was designed to assess the feasibility of using unipolar electrocautery to decrease bleeding. METHODS: Under general anesthesia, the livers of eight dogs were surgically exposed. A mean of 15 biopsies was obtained with 18-gauge needles from each liver by alternating biopsies without and with electrocautery. Cautery was performed by applying radiofrequency energy at 25 watts (6 animals) or 125 watts (2 animals) to the needle as the needle was withdrawn from the liver. Blood loss was measured by applying preweighed sponges to the biopsy site, then reweighing them after use. Biopsy specimens were examined by light microscopy. RESULTS: The mean (+/- SD) blood loss was 0.44 g (+/- 1.36 g) with electrocautery and 1.47 g (+/- 2.23 g) without electrocautery (P < .01). No thermal injury was noted in the biopsy specimens when cautery was applied at 25 watts. CONCLUSIONS: The application of radiofrequency current to the biopsy needle after liver biopsy is a feasible and effective method to reduce blood loss in our canine model.


Assuntos
Biópsia por Agulha/métodos , Eletrocoagulação , Hemorragia/prevenção & controle , Fígado/patologia , Animais , Biópsia por Agulha/efeitos adversos , Cães , Hemorragia/etiologia
18.
Clin Radiol ; 47(1): 39-45, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8428416

RESUMO

Computed digital radiography offers a number of potential advantages over conventional film-screen imaging. To determine the applicability of these to portable neonatal examinations we performed a controlled prospective study comparing conventional 200 speed film-screen with a computed radiography unit in an animal model. Images acceptable for diagnostic purposes were obtained on the digital system over an exposure range many orders of magnitude greater than was possible on the film-screen system. Digital imaging offers potential for elimination of repeat examinations due to suboptimal exposure factors, and for reduction in radiation dose to the patient. We believe that computed digital radiography should be particularly suited to portable neonatal imaging.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Animais , Estudos de Avaliação como Assunto , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Coelhos , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação
19.
Pediatr Radiol ; 22(5): 346-9, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1408442

RESUMO

A controlled prospective study, in an animal model chosen to simulate portable neonatal radiography, was performed to compare the response of the Philips Computed Radiography (CR) system and conventional 200 speed film-screen (FS) to variation in imaging kVp. Acceptable images were obtained on the CR system over a very wide kVp range. In contrast the FS system produced acceptable images over a narrow kVp range. This ability suggests that the CR system should eliminate the need for repeat examinations in cases where a suboptimal kVp setting would have resulted in an unacceptable FS image. CR technology should therefore be ideally suited to portable radiography especially in situations where selection of correct exposure factors is difficult as in the neonatal nursery.


Assuntos
Intensificação de Imagem Radiográfica , Ecrans Intensificadores para Raios X , Animais , Estudos Prospectivos , Coelhos , Doses de Radiação , Radiografia Abdominal , Radiografia Torácica
20.
Radiol Technol ; 62(3): 228-30, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1998063

RESUMO

Evaluating new developments in surgical methods and materials of aortic bypass prosthetics requires the use of an appropriate animal model, a well established surgical protocol and post surgical aortography. This article describes the surgical technique, post operative care and the angiographic technique used for an apicoaortic conduit placement in a canine model.


Assuntos
Aorta/cirurgia , Aortografia , Prótese Vascular , Ventrículos do Coração/cirurgia , Animais , Aorta/transplante , Cães , Feminino , Ventrículos do Coração/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA