Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Otolaryngol ; 30(4): 328-32, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16209674

RESUMO

AIM: The aim of this study was to determine the effects of alcohol on the psychophysical responses in patients with cochlear implants. This has not been previously studied. It was also hoped to provide information that could suggest possible sites of action of the known effects of alcohol on the auditory pathway. DESIGN: A prospective randomized placebo-controlled trial, with full ethical approval. PARTICIPANTS: Eight successful cochlear implant users were selected, of whom two had bilateral implants which were tested separately. In total 10 cochlear implants were tested. INTERVENTION: Alcohol was given in the form of vodka (50% alcohol, 1 mL/kg body weight) with 500 mL of orange and cranberry juice. The placebo control was given in the form of 500 mL of orange and cranberry juice alone. OUTCOME MEASUREMENT: The 'comfort level' (C level) was recorded before, and 1 h after alcohol or placebo ingestion for each patient's cochlear implant. Blood alcohol concentration was determined prior to alcohol or placebo consumption and then repeated after 45, 60, 90 and 180 min. RESULTS: The mean blood alcohol concentration 1 h after ingestion was 50 mg/dL. In the 'alcohol' arm the mean electrical unit increase in the C level was 19.9 with a standard deviation of 2.2. In the control arm the mean change in C level was 0.10 with a standard deviation of 0.3. CONCLUSIONS: In this first prospective randomized control study of the effect of alcohol on sound perception in cochlear implant users, alcohol significantly increased the upper end of the dynamic range (C levels) in comparison with placebo (P = <0.0001 using paired t-test analysis). This effect is likely to be the result of change in the auditory pathways proximal to the cochlea.


Assuntos
Bebidas Alcoólicas/efeitos adversos , Vias Auditivas/efeitos dos fármacos , Implantes Cocleares , Etanol/efeitos adversos , Percepção Sonora/efeitos dos fármacos , Adulto , Audiometria da Fala , Limiar Auditivo/efeitos dos fármacos , Surdez/reabilitação , Etanol/sangue , Humanos , Estudos Prospectivos , Análise de Regressão , Método Simples-Cego
2.
Int J Pediatr Otorhinolaryngol ; 43(2): 129-40, 1998 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-9578122

RESUMO

In this case report a near-term infant with Glucose 6-Phosphate Dehydrogenase (G6-PD) deficiency had an unconjugated bilirubin level of 703 on the 11th day of life but maintained his haemoglobin levels above 11 gm/dl. At 4 months of age he demonstrated the clinical picture of Kernicterus: profound sensorineural deafness and evidence of encephalopathy. However, by 15 months of age his abnormal cerebral and motor signs had regressed to a near-normal level in parallel with a gradual improvement in hearing, which also reached normal levels, first in the right ear, then in the left. At this age residual mental retardation has not been excluded but his communication skills, though delayed by 4-6 months, were moving towards the level when they would be appropriate for his age.


Assuntos
Glucose Desidrogenase/deficiência , Perda Auditiva Neurossensorial/complicações , Kernicterus/complicações , Audiometria de Resposta Evocada , Glucose 1-Desidrogenase , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Lactente , Kernicterus/terapia , Masculino , Remissão Espontânea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA