Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386539

RESUMO

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

2.
Rev Sci Instrum ; 89(10): 10E102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399949

RESUMO

Two graphite divertor elements called scrapers have been installed on the Wendelstein 7-X stellarator in the throat of the magnetic island divertor. To diagnose one, we have designed, built, calibrated, and installed a new infrared/visible imaging endoscope system to enable detailed observations of the plasma interactions and heat loads at one of the scrapers and the nearby divertor surfaces. The new system uses a shuttered pinhole-protected pair of 90° off-axis 228 mm focal length aluminum parabolic mirrors, and two flat turning metal mirrors, to send light to a sapphire vacuum window 1.6 meters away, beyond which we have co-located telephoto lens-based infrared and visible cameras. The back-to-back off-axis parabolas serve to cancel out most aberrations, enabling the use of off-the-shelf commercial optics outside of the vessel. For the infrared, we use a 3-5 µm 1-megapixel FLIR SC8303HD camera and for the visible, a 5-megapixel CMOS PCO 5.5 edge camera. A short 1-m quartz pickoff fiber is used to send 200-1100 nm light to a compact spectrometer, also located in the same iron shield box as the cameras. The camera field of view covers the 700 mm length of the scraper, and includes locations monitored by thermocouples and Langmuir probes embedded in some of the scraper tiles. Predicted and actual optical test performances of the overall system are compared.

3.
Rev Sci Instrum ; 87(11): 11D430, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910322

RESUMO

The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

4.
Rev Sci Instrum ; 87(11): 11D419, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910440

RESUMO

Recent improvements in software tools and methodology have allowed us to perform a more comprehensive in-vessel calibration for all mid-infrared camera systems at JET. A comparison of experimental methods to calculate the non-uniformity correction is described as well as the linearity for the different camera systems. Measurements of the temperature are assessed for the different diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...