Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vitreoretin Dis ; 6(5): 412-413, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37006906

RESUMO

Purpose: This work reports retinal findings in an adult patient with vitamin B6 deficiency. Methods: A case review of a single patient is presented. Results: A patient with a Roth-type retinal lesion and a history of nonepileptic seizures was found to have lymphocytic colitis. She was treated with pyridoxine, which resolved her seizures and the white-centered hemorrhage. Conclusions: Vitamin B6 deficiency should be considered in the differential diagnosis of patients presenting with white-centered hemorrhages and a history of nonepileptic seizures.

2.
Phys Med Biol ; 48(19): 3239-60, 2003 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-14579863

RESUMO

The Born approximation deconvolved inverse scattering imaging technique is an alternative to the conventional pulse-echo method. This novel technique deconvolves the incident pulse from the reflected pulse, and uses the resulting impulse response to produce an image of the acoustic impedance distribution. It is applicable mainly to structures that resemble a layered medium. The images captured by this method prove to have improved resolution and are free of speckle. With this method one can use ultrasound of lower frequencies than would be required by the pulse-echo method to achieve the same resolution. To provide further improvement of images the second harmonic signals can be employed. Here we describe the deconvolved inverse scattering imaging technique with account of the second harmonic signal. For this purpose the hybrid transducer by Krautkramer Branson Co., which consists of a cylindrical 5 MHz transducer wrapped in an annulus-shaped 2.5 MHz transducer, has been used. The phantom and soft tissue were imaged and in both cases the account of the second harmonic reflection data provides an improvement of the image quality.


Assuntos
Algoritmos , Tecido Conjuntivo/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Animais , Esôfago/diagnóstico por imagem , Análise de Fourier , Controle de Qualidade , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Estômago/diagnóstico por imagem , Suínos
3.
Ultrasonics ; 40(9): 983-96, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12385955

RESUMO

By using the Born approximation deconvolved inverse scattering method instead of the traditional pulse-echo method for analyzing ultrasound pulse reflections from plastic phantoms and soft tissue specimens, improvement in image resolution is shown to be possible provided these targets are fair approximations to layered media. These images are free of speckle and are more vivid than the usual pulse-echo images.


Assuntos
Ultrassom , Acústica , Animais , Colo/diagnóstico por imagem , Humanos , Modelos Teóricos , Imagens de Fantasmas , Reto/diagnóstico por imagem , Estômago/diagnóstico por imagem , Suínos , Transdutores , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...