Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Sci Eng C Mater Biol Appl ; 71: 322-334, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27987714

RESUMO

The novel Ti-20Zr-5Ta-2Ag alloy was characterised concerning its microstructure, morphology, mechanical properties, its passive film composition and thickness, its long-term electrochemical stability, corrosion resistance, ion release rate in Ringer solution of acid, neutral and alkaline pH values and antibacterial activity. The new alloy has a crystalline α microstructure (by XRD). Long-term XPS and SEM analyses show the thickening of the passive film and the deposition of hydroxyapatite in neutral and alkaline Ringer solution. The values of the electrochemical parameters confirm the over time stability of the new alloy passive film. All corrosion parameters have very favourable values in time which attest a high resistance to corrosion. Impedance spectra evinced a bi-layered passive film formed by the barrier, insulating layer and the porous layer. The monitoring of the open circuit potentials indicated the stability of the protective layers and their thickening in time. The new alloy releases (by ICP-MS measurements) very low quantities of Ti, Zr, Ag ions and no Ta ions. The new alloy exhibits a low antibacterial activity.


Assuntos
Ligas/química , Antibacterianos/química , Implantes Experimentais , Prata/química , Titânio/química , Zircônio/química , Fatores de Tempo
2.
Mater Sci Eng C Mater Biol Appl ; 59: 346-355, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26652383

RESUMO

A new CoCrNbMoZr alloy, with Nb and Zr content is characterized from the point of view of surface features, corrosion resistance and biological performance in order to be proposed as dental restorative material. Its properties are discussed in comparison with commercial Heraenium CE alloy based on Co, Cr and Mo as well. The microstructure of both alloys was revealed by scanning electron microscopy (SEM). The composition and thickness of the alloy native passive films were identified by X-ray photoelectron spectroscopy (XPS). The surface characteristics were analyzed by atomic force microscopy (AFM) and contact angle techniques. The quantity of ions released from alloys in artificial saliva was evaluated with inductively coupled plasma-mass spectroscopy (ICP-MS) measurements. The electrochemical stability was studied in artificial Carter-Brugirard saliva, performing open circuit potentials, polarization resistances and corrosion currents and rates. The biological performance of the new alloy was tested in vitro in terms of human adipose stem cells (hASCs) morphology, viability and proliferation status. The new alloy is very resistant to the attack of the aggressive ions from the artificial saliva. The surface properties, the roughness and wettabiliy sustain the cell behavior. The comparison of the new alloy behavior with that of existing commercial CoCrMo alloy showed the superior properties of the new metallic biomaterial.


Assuntos
Tecido Adiposo/metabolismo , Ligas , Técnicas Eletroquímicas , Teste de Materiais , Metais Pesados , Células-Tronco/metabolismo , Tecido Adiposo/citologia , Ligas/química , Ligas/farmacologia , Humanos , Metais Pesados/química , Metais Pesados/farmacologia , Células-Tronco/citologia
3.
Mater Sci Eng C Mater Biol Appl ; 44: 362-70, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25280716

RESUMO

In this study, the "Gum Metal" titanium-based alloy (Ti-23Nb-0.7Ta-2Zr-1.2O) was synthesized by melting and then characterized in order to evaluate its potential for biomedical applications. Thus, the mechanical properties, the corrosion resistance in simulated body fluid and the in vitro cell response were investigated. It was shown that this alloy presents a very high strength, a low Young's modulus and a high recoverable strain by comparison with the titanium alloys currently used in medicine. On the other hand, all electrochemical and corrosion parameters exhibited more favorable values showing a nobler behavior and negligible toxicity in comparison with the commercially pure Ti taken as reference. Furthermore, the biocompatibility tests showed that this alloy induced an excellent response of MC3T3-E1 pre-osteoblasts in terms of attachment, spreading, viability, proliferation and differentiation. Consequently, the "Gum Metal" titanium-based alloy processes useful characteristics for the manufacturing of highly biocompatible medical devices.


Assuntos
Materiais Biocompatíveis/química , Titânio/química , Células 3T3-L1 , Ligas/química , Animais , Líquidos Corporais/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Módulo de Elasticidade/efeitos dos fármacos , Técnicas Eletroquímicas , Teste de Materiais/métodos , Camundongos , Osteoblastos/efeitos dos fármacos , Titânio/farmacologia
4.
Mater Sci Eng C Mater Biol Appl ; 33(7): 4173-82, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23910330

RESUMO

In this study, a superelastic Ni-free Ti-based biomedical alloy was treated in surface by the implantation of nitrogen ions for the first time. The N-implanted surface was characterized by X-ray diffraction, X-ray photoelectron spectroscopy, and secondary ion mass spectroscopy, and the superficial mechanical properties were evaluated by nano-indentation and by ball-on-disk tribological tests. To investigate the biocompatibility, the corrosion resistance of the N-implanted Ti alloy was evaluated in simulated body fluids (SBF) complemented by in-vitro cytocompatibility tests on human fetal osteoblasts. After implantation, surface analysis methods revealed the formation of a titanium-based nitride on the substrate surface. Consequently, an increase in superficial hardness and a significant reduction of friction coefficient were observed compared to the non-implanted sample. Also, a better corrosion resistance and a significant decrease in ion release rates have been obtained. Cell culture experiments indicated that the cytocompatibility of the N-implanted Ti alloy was superior to that of the corresponding non-treated sample. Thus, this new functional N-implanted titanium-based superelastic alloy presents the optimized properties that are required for various medical devices: superelasticity, high superficial mechanical properties, high corrosion resistance and excellent cytocompatibility.


Assuntos
Ligas/farmacologia , Tecnologia Biomédica/métodos , Elasticidade , Nitrogênio/química , Titânio/farmacologia , Líquidos Corporais/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Corrosão , Feto/citologia , Fibronectinas/biossíntese , Fricção , Dureza , Humanos , L-Lactato Desidrogenase/metabolismo , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/enzimologia , Espectroscopia Fotoeletrônica , Potenciometria , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração/efeitos dos fármacos , Difração de Raios X
5.
J Mater Sci Mater Med ; 23(12): 2953-66, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22918550

RESUMO

In this study, the new Hardion+ micro-implanter technology was used to modify surface properties of biomedical pure titanium (CP-Ti) and Ti-6Al-4V ELI alloy by implantation of nitrogen ions. This process is based on the use of an electron cyclotron resonance ion source to produce a multienergetic ion beam from multicharged ions. After implantation, surface analysis methods revealed the formation of titanium nitride (TiN) on the substrate surfaces. An increase in superficial hardness and a significant reduction of friction coefficient were observed for both materials when compared to non-implanted samples. Better corrosion resistance and a significant decrease in ion release rates were observed for N-implanted biomaterials due to the formation of the protective TiN layer on their surfaces. In vitro tests performed on human fetal osteoblasts indicated that the cytocompatibility of N-implanted CP-Ti and Ti-6Al-4V alloy was enhanced in comparison to that of the corresponding non treated samples. Consequently, Hardion+ implantation technique can provide titanium alloys with better qualities in terms of corrosion resistance, cell proliferation, adhesion and viability.


Assuntos
Ligas/química , Nitrogênio/química , Titânio/química , Materiais Biocompatíveis/química , Adesão Celular , Proliferação de Células , Sobrevivência Celular , Corrosão , Matriz Extracelular/metabolismo , Fibronectinas/química , Humanos , Íons , Espectrometria de Massas/métodos , Teste de Materiais , Nitrogênio/metabolismo , Osteoblastos/citologia , Próteses e Implantes , Propriedades de Superfície , Temperatura
6.
J Mech Behav Biomed Mater ; 4(7): 1421-30, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21783152

RESUMO

In this work, a multi-elementary Ti-10Zr-5Nb-5Ta alloy, with non-toxic alloying elements, was used to develop an accumulative roll bonding, ARB-type procedure in order to improve its structural and mechanical properties. The alloy was obtained by cold crucible semi-levitation melting technique and then was ARB deformed following a special route. After three ARB cycles, the total deformation degree per layer is about 86%; the calculated medium layer thickness is about 13 µm. The ARB processed alloy has a low Young's modulus of 46 GPa, a value very close to the value of the natural cortical bone (about 20 GPa). Data concerning ultimate tensile strength obtained for ARB processed alloy is rather high, suitable to be used as a material for bone substitute. Hardness of the ARB processed alloy is higher than that of the as-cast alloy, ensuring a better behaviour as a implant material. The tensile curve for the as-cast alloy shows an elastoplastic behaviour with a quite linear elastic behaviour and the tensile curve for the ARB processed alloy is quite similar with a strain-hardening elastoplastic body. Corrosion behaviour of the studied alloy revealed the improvement of the main electrochemical parameters, as a result of the positive influence of ARB processing. Lower corrosion and ion release rates for the ARB processed alloy than for the as-cast alloy, due to the favourable effect of ARB thermo-mechanical processing were obtained.


Assuntos
Ligas/química , Materiais Revestidos Biocompatíveis/química , Fenômenos Mecânicos , Nanoestruturas/química , Corrosão , Nióbio/química , Tantálio/química , Titânio/química , Zircônio/química
7.
J Mech Behav Biomed Mater ; 3(8): 559-64, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20826361

RESUMO

In this study, a new Ti-25Ta-25Nb (mass%) beta alloy was synthesised by cold crucible semi-levitation melting. This technique made it possible to obtain homogeneous ingots although the elements used have very different melting points. After melting, a thermo-mechanical treatment was applied in order to obtain a perfectly recrystallised beta microstructure. For this alloy composition, the tensile tests showed a very low Young's modulus associated with an important super-elastic behaviour, which contributes to decrease the elastic modulus under stress and to increase the recoverable strain. On the other hand, the corrosion tests, which were carried out in a neutral Ringer solution, indicated a corrosion resistance higher than that of the commercially pure CP Ti alloy. These results show that this new alloy possesses all the characteristics necessary for its long-term use in medical implants.


Assuntos
Ligas/síntese química , Materiais Revestidos Biocompatíveis/síntese química , Elasticidade , Corrosão , Soluções Isotônicas/química , Nióbio/química , Solução de Ringer , Estresse Mecânico , Tantálio/química , Temperatura , Resistência à Tração , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...