Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Digit Health ; 10: 20552076241254026, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38746874

RESUMO

Introduction: Fitness trackers can provide continuous monitoring of vital signs and thus have the potential to become a complementary, mobile and effective tool for early detection of patient deterioration and post-operative complications. Methods: To evaluate potential implementations in acute care setting, we included 36 patients after moderate to major surgery in a recent randomised pilot trial to compare the performance of vital sign monitoring by three different fitness trackers (Apple Watch 7, Garmin Fenix 6pro and Withings ScanWatch) with established standard clinical monitors in post-anaesthesia care units and monitoring wards. Results: During a cumulative period of 56 days, a total of 53,197 heart rate (HR) measurements, as well as 12,219 measurements of the peripheral blood oxygen saturation (SpO2) and 28,954 respiratory rate (RR) measurements were collected by fitness trackers. Under real-world conditions, HR monitoring was accurate and reliable across all benchmarked devices (r = [0.95;0.98], p < 0.001; Bias = [-0.74 bpm;-0.01 bpm]; MAPE∼2%). However, the performance of SpO2 (r = [0.21;0.68]; p < 0.001; Bias = [-0.46%;-2.29%]; root-mean-square error = [2.82%;4.1%]) monitoring was substantially inferior. RR measurements could not be obtained for two of the devices, therefore exclusively the accuracy of the Garmin tracker could be evaluated (r = 0.28, p < 0.001; Bias = -1.46/min). Moreover, the time resolution of the vital sign measurements highly depends on the tracking device, ranging from 0.7 to 117.94 data points per hour. Conclusion: According to the results of the present study, tracker devices are generally reliable and accurate for HR monitoring, whereas SpO2 and RR measurements should be interpreted carefully, considering the clinical context of the respective patients.

2.
Ann Thorac Cardiovasc Surg ; 28(2): 146-153, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-34690218

RESUMO

PURPOSE: Blood loss along with inadequate evacuation after cardiac surgery leads to retained blood syndrome (RBS) in the pleural and/or pericardial cavity. Re-sternotomy is often needed for clot evacuation. Video-assisted thoracoscopic surgery (VATS) evacuation is a less-invasive procedure. However, sufficient evidence on safety and outcomes is lacking. METHODS: Thirty patients who developed hemothorax and/or hemopericardium after cardiac surgery and underwent VATS evacuation between April 2015 and September 2020 were included in this retrospective single-center analysis. RESULTS: The median patient age was 70 (interquartile range: IQR 62-75) years, body mass index (BMI) was 24.7 (IQR 22.8-29) kg/m2, time between initial cardiac surgery and VATS was 17 (IQR 11-21) days, 30% of the patients were female, 60% resided in the ICU, and 17% were nicotine users. Coronary artery bypass graft was the most frequent initial cardiac procedure. Median operation time was 120 (IQR 90-143) min, 23% of the patients needed an additional VATS, and the median length of hospital stay after VATS was 8 (IQR 5-14) days. All patients survived VATS, and we experienced no mortality related to the VATS procedure. CONCLUSION: In our study, VATS for evacuation of RBS after cardiac surgery was a feasible, safe, and efficient alternative approach to re-sternotomy in selected patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgia Torácica Vídeoassistida , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Resultado do Tratamento
3.
Artif Organs ; 43(3): 242-253, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30040134

RESUMO

Noninvasive measurements of blood pressure (BP) and cardiac output (CO) are crucial in the follow-up of continuous-flow left ventricular assist device (CF-LVAD) patients. For our pilot study, we sought to compare BP measurements between a tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Ltd., Gyeonggi-do, South Korea) and Doppler ultrasound in CF-LVAD patients, as well as to compare the BPPA estimated CO to LVAD calculated blood flow and to the patient's intrinsic CO estimated with transthoracic echocardiography (TTE). Ambulatory CF-LVAD patients (6 HeartMate, 26 HeartMate II), were included. According to TTE findings, patients were then subdivided in two groups: patients with an opening aortic valve (OAV) [n = 21] and those with an intermittent opening aortic valve (IOAV) [n = 11]. We found a very good correlation of systolic BP (SBP) measurements between the two methods, BPPA and Doppler ultrasound (r = 0.87, P < 0.0001). Bland-Altman plots for SBP revealed a low bias of -4.6 mm Hg and SD of ±4.7 mm Hg. In CF-LVAD patients with IOAV, the BPPA-CO had a good correlation with the LVAD-flow (r = 0.78, P < 0.0001), but in OAV patients, there was no correlation. After adding the patient's intrinsic CO, estimated from TTE in patients with OAV to the LVAD-flow, we found a very good correlation between the BPPA-CO and LVAD-flow + TTE-CO (r = 0.81, P = 0.002). Our study demonstrated that compared with the standard clinical method, Doppler ultrasound, the BPPA measured BP noninvasively with good accuracy and precision of agreement. In addition, tonometry BPPA provided further valuable information regarding the CF-LVAD patient's intrinsic CO.


Assuntos
Determinação da Pressão Arterial/métodos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Assistência ao Convalescente/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Débito Cardíaco/fisiologia , Ecocardiografia/métodos , Ecocardiografia Doppler/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Manometria/instrumentação , Manometria/métodos , Pessoa de Meia-Idade , Projetos Piloto , Artéria Radial , Volume Sistólico/fisiologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...