Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Appl Clin Med Phys ; 25(5): e14340, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605540

RESUMO

BACKGROUND: Global shortages of iodinated contrast media (ICM) during COVID-19 pandemic forced the imaging community to use ICM more strategically in CT exams. PURPOSE: The purpose of this work is to provide a quantitative framework for preserving iodine CNR while reducing ICM dosage by either lowering kV in single-energy CT (SECT) or using lower energy virtual monochromatic images (VMI) from dual-energy CT (DECT) in a phantom study. MATERIALS AND METHODS: In SECT study, phantoms with effective diameters of 9.7, 15.9, 21.1, and 28.5 cm were scanned on SECT scanners of two different manufacturers at a range of tube voltages. Statistical based iterative reconstruction and deep learning reconstruction were used. In DECT study, phantoms with effective diameters of 20, 29.5, 34.6, and 39.7 cm were scanned on DECT scanners from three different manufacturers. VMIs were created from 40 to 140 keV. ICM reduction by lowering kV levels for SECT or switching from SECT to DECT was calculated based on the linear relationship between iodine CNR and its concentration under different scanning conditions. RESULTS: On SECT scanner A, while matching CNR at 120 kV, ICM reductions of 21%, 58%, and 72% were achieved at 100, 80, and 70 kV, respectively. On SECT scanner B, 27% and 80% ICM reduction was obtained at 80 and 100 kV. On the Fast-kV switch DECT, with CNR matched at 120 kV, ICM reductions were 35%, 30%, 23%, and 15% with VMIs at 40, 50, 60, and 68 keV, respectively. On the dual-source DECT, ICM reductions were 52%, 48%, 42%, 33%, and 22% with VMIs at 40, 50, 60, 70, and 80 keV. On the dual-layer DECT, ICM reductions were 74%, 62%, 45%, and 22% with VMIs at 40, 50, 60, and 70 keV. CONCLUSIONS: Our work provided a quantitative baseline for other institutions to further optimize their scanning protocols to reduce the use of ICM.


Assuntos
COVID-19 , Meios de Contraste , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Meios de Contraste/química , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/instrumentação , SARS-CoV-2 , Adulto , Criança , Razão Sinal-Ruído , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
2.
Water Sci Technol ; 88(8): 1927-1943, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37906450

RESUMO

In this paper, molybdenum disulfide was grown on the surface of iron-containing tailings by hydrothermal method, and a series of highly efficient activated persulfate (PMS) iron-based catalysts were successfully prepared. The results show that in the CTM 1-200/PMS system, the additional ratio of tailings and the hydrothermal temperature have important effects on the catalyst. The catalyst prepared under the conditions of CT:MoS2 (molar ratio 1:1) and hydrothermal temperature of 200 °C (CTM 1-200) had the best degradation effect on BPA, and the degradation effect was increased by four times. The reason for the improvement of degradation efficiency is that the introduction of MoS2 accelerates the REDOX cycle between Fe(II)/Fe(III), and the reduction of Fe(III) is mainly related to Mo(IV), while the reduction capacity of S is relatively weak. Molybdenum disulfide/iron tailing composite material provides a way for tailings to solve the problem of water pollution.


Assuntos
Ferro , Molibdênio , Compostos Férricos , Peróxidos
3.
Med Phys ; 50(10): 6071-6078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37475459

RESUMO

BACKGROUND: Computed tomography (CT) number accuracy is important for quality assurance in CT imaging. However, in dual-energy CT imaging, there are no widely used action limits for CT number accuracy in spectral images, information that is urgently needed. PURPOSE: To establish action limits for spectral CT images using longitudinal spectral data and an American College of Radiology (ACR) phantom. METHODS: An ACR accreditation phantom was scanned routinely as part of a quality control program in our institution. We selected and analyzed 57 continuous weekly scans. The CT numbers or the density values of conventional and spectral images, including virtual monoenergetic images (40, 50, 70, 120, and 200 keV), iodine maps, calcium suppressed, and virtual non-contrast images, were measured in the four inserts (solid water, bone, polyethylene, and acrylic) of the phantom. Longitudinal data were analyzed for correlation using Pearson's correlation coefficient (r) and standard deviation (SD). The SD ratios between spectral images and conventional images were calculated and the action limits for spectral images were established based on the action limits from the ACR. RESULTS: Strong to very strong correlations (r > 0.70 or r < -0.70) were found among most spectral image types except the 200 keV images using solid water, polyethylene, and acrylic inserts (r = [-0.45, 0.64]). The SD ratio was highest for the 40 keV images, ranging from 2.8 to 6.5. The action limits of the bone insert were baseline ± 5.3 mg/mL for the iodine map and ranged from baseline ± 23.0 HU to baseline ± 391.9 HU for the other image types. The action limits for solid water ranged from baseline ± 4.1 HU to baseline ± 25.3 HU. The results for the polyethylene and the acrylic insert were close to those for solid water. Baselines can be established using the average of the initial 5∼10 measurements. CONCLUSIONS: Using longitudinal data, we estimated the action limits for CT number accuracy in the spectral images. This paves the way for establishing a comprehensive quality control program for spectral CT imaging.

4.
Anim Biosci ; 36(12): 1842-1852, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37402452

RESUMO

OBJECTIVE: Hairy vetch is considered to improve the nutritional value of corn because of its high protein and mineral levels. To better understand the mechanism underlying hairy vetch regulated whole-plant corn silage fermentation, this experiment investigated the fermentation quality and bacterial community of whole-plant corn and hairy vetch mixture. METHODS: Whole-plant corn and hairy vetch were mixed at ratios of 10:0 (Mix 10:0), 8:2 (Mix 8:2), 6:4 (Mix 6:4), 4:6 (Mix 4:6), 2:8 (Mix 2:8), and 0:10 (Mix 0:10) on a fresh weight basis. After ensiling 60 days, samples were collected to examine the fermentation dynamics, ensiling characteristics, and bacterial communities. RESULTS: Mix 0:10, Mix 2:8, and Mix 4:6 showed poor fermentation characteristics. Mix 8:2 and Mix 6:4 silages showed high quality, based on the low pH, acetic acid, and ammonia nitrogen levels and the high lactic acid, crude protein, and crude fat contents. The bacterial diversity was affected by the mixing ratio of the two forage species. The genus Lactobacillus dominated the bacterial community in Mix 10:0 silage, whereas with the addition of hairy vetch, the relative abundance of unclassified-Enterobacter increased from 7.67% to 41.84%, and the abundance of Lactobacillus decreased from 50.66% to 13.76%. CONCLUSION: The silage quality of whole-plant corn can be improved with inclusion levels of hairy vetch from 20% to 40%.

5.
Phys Imaging Radiat Oncol ; 26: 100438, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37342208

RESUMO

Background and Purpose: A recently developed biology-guided radiotherapy platform, equipped with positron emission tomography (PET) and computed tomography (CT), provides both anatomical and functional image guidance for radiotherapy. This study aimed to characterize performance of the kilovoltage CT (kVCT) system on this platform using standard quality metrics measured on phantom and patient images, using CT simulator images as reference. Materials and Methods: Image quality metrics, including spatial resolution/modular transfer function (MTF), slice sensitivity profile (SSP), noise performance and image uniformity, contrast-noise ratio (CNR) and low-contrast resolution, geometric accuracy, and CT number (HU) accuracy, were evaluated on phantom images. Patient images were evaluated mainly qualitatively. Results: On phantom images the MTF10% is about 0.68 lp/mm for kVCT in PET/CT Linac. The SSP agreed with nominal slice thickness within 0.7 mm. The diameter of the smallest visible target (1% contrast) is about 5 mm using medium dose mode. The image uniformity is within 2.0 HU. The geometric accuracy tests passed within 0.5 mm. Relative to CT simulator images, the noise is generally higher and the CNR is lower in PET/CT Linac kVCT images. The CT number accuracy is comparable between the two systems with maximum deviation from the phantom manufacturer range within 25 HU. On patient images, higher spatial resolution and image noise are observed on PET/CT Linac kVCT images. Conclusions: Major image quality metrics of the PET/CT Linac kVCT were within vendor-recommended tolerances. Better spatial resolution but higher noise and better/comparable low contrast visibility were observed as compared to a CT simulator when images were acquired with clinical protocols.

6.
J Vasc Interv Radiol ; 34(4): 544-555.e11, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36379286

RESUMO

PURPOSE: To update normative data on fluoroscopy dose indices in the United States for the first time since the Radiation Doses in Interventional Radiology study in the late 1990s. MATERIALS AND METHODS: The Dose Index Registry-Fluoroscopy pilot study collected data from March 2018 through December 2019, with 50 fluoroscopes from 10 sites submitting data. Primary radiation dose indices including fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA) were collected for interventional radiology fluoroscopically guided interventional (FGI) procedures. Clinical facility procedure names were mapped to the American College of Radiology (ACR) common procedure lexicon. Distribution parameters including the 10th, 25th, 50th, 75th, 95th, and 99th percentiles were computed. RESULTS: Dose indices were collected for 70,377 FGI procedures, with 50,501 ultimately eligible for analysis. Distribution parameters are reported for 100 ACR Common IDs. FT in minutes, Ka,r in mGy, and PKA in Gy-cm2 are reported in this study as (n; median) for select ACR Common IDs: inferior vena cava filter insertion (1,726; FT: 2.9; Ka,r: 55.8; PKA: 14.19); inferior vena cava filter removal (464; FT: 5.7; Ka,r: 178.6; PKA: 34.73); nephrostomy placement (2,037; FT: 4.1; Ka,r: 39.2; PKA: 6.61); percutaneous biliary drainage (952; FT: 12.4; Ka,r: 160.5; PKA: 21.32); gastrostomy placement (1,643; FT: 3.2; Ka,r: 29.1; PKA: 7.29); and transjugular intrahepatic portosystemic shunt placement (327; FT: 34.8; Ka,r: 813.0; PKA: 181.47). CONCLUSIONS: The ACR DIR-Fluoro pilot has provided state-of-the-practice statistics for radiation dose indices from IR FGI procedures. These data can be used to prioritize procedures for radiation optimization, as demonstrated in this work.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Doses de Radiação , Projetos Piloto , Fluoroscopia , Radiologia Intervencionista/métodos , Sistema de Registros , Radiografia Intervencionista/efeitos adversos
7.
J Vasc Interv Radiol ; 34(4): 556-562.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36031041

RESUMO

PURPOSE: To compare radiation dose index distributions for fluoroscopically guided interventions in interventional radiology from the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR-Fluoro) pilot to those from the Radiation Doses in Interventional Radiology (RAD-IR) study. MATERIALS AND METHODS: Individual and grouped ACR Common identification numbers (procedure types) from the DIR-Fluoro pilot were matched to procedure types in the RAD-IR study. Fifteen comparisons were made. Distribution parameters, including the 10th, 25th, 50th, 75th, and 95th percentiles, were compared for fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA). Two derived indices were computed using median dose indices. The procedure-averaged reference air kerma rate (Ka,r¯) was computed as Ka,r / FT. The procedure-averaged x-ray field size at the reference point (Ar) was computed as PKA / (Ka,r × 1,000). RESULTS: The median FT was equally likely to be higher or lower in the DIR-Fluoro pilot as it was in the RAD-IR study, whereas the maximum FT was almost twice as likely to be higher in the DIR-Fluoro pilot than it was in the RAD-IR study. The median Ka,r was lower in the DIR-Fluoro pilot for all procedures, as was median PKA. The maximum Ka,r and PKA were more often higher in the DIR-Fluoro pilot than in the RAD-IR study. Ka,r¯ followed the same pattern as Ka,r, whereas Ar was often greater in DIR-Fluoro. CONCLUSIONS: The median dose indices have decreased since the RAD-IR study. The typical Ka,r rates are lower, a result of the use of lower default dose rates. However, opportunities for quality improvement exist, including renewed focus on tight collimation of the imaging field of view.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Radiologia Intervencionista/métodos , Doses de Radiação , Fluoroscopia , Radiografia Intervencionista/efeitos adversos , Sistema de Registros
8.
Materials (Basel) ; 15(12)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35744293

RESUMO

In this study, ball mill pretreated iron ore tailings were modified with tetraethoxysilane (TEOS) and hexadecyltrimethoxysilane (HDTMS) to obtain iron ore tailings/polysiloxane (IOT/POS) superhydrophobic powders, which were subsequently mixed with chloroprene rubber solution (CRS) to prepare durable superhydrophobic composite coatings. The effect of HDTMS amount and reaction time on the wettability of the superhydrophobic powder was investigated. The influence of the superhydrophobic powders concentration on the wettability of the composite coatings as well as the degree of damage of the superhydrophobicity of the composite coating was analyzed by using the sandpaper abrasion and tape peeling tests. Further, SEM and FTIR were used to analyze the formation mechanism of the IOT/POS superhydrophobic powders and coatings. The results showed for an HDTMS amount of 2.5 mmol and reaction time of 4 h, the contact angle of the IOT/POS powder was 157.3 ± 0.6°, whereas the slide angle was determined to be 5.9 ± 0.8°. For an IOT/POS powder content of 0.06 g/mL in CRS, the contact angle value of the superhydrophobic composite coating was 159.2 ± 0.5°, whereas the slide angle value was 5.5 ± 0.8°. The superhydrophobic composite coating still maintained the superhydrophobicity after the sandpaper abrasion and tape peeling tests, which indicated the iron ore tailings solid waste has the potential to prepare superhydrophobic coatings.

9.
Water Sci Technol ; 85(8): 2332-2349, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35486458

RESUMO

In this work, iron was recovered from a kind of iron-rich pickling sludge by an acid leaching process, and the recycled iron was used as a catalyst to activate peroxydisulfate (PS) for the degradation of phenol. Different kinds of sludge catalysts were prepared by different drying methods such as ordinary drying (Ods), freeze drying (Fds) and vacuum drying (Vds). The degradation performance of the different catalysts/PS system under different conditions was explored, the vacuum drying sludge catalyst (Vds) has the best activity in a wide pH range (pH = 3-10) and a wide temperature range (0-40 °C). At the same time, the effect of a series of chelating agents (Oxalic acid (OA), Citric acid (CA), Tartaric acid (TA), Malic acid (DL-MA) and Ethylenediaminetetraacetic acid (EDTA)) on Vds/PS system was verified, and TA was selected as the best chelating agent to promote the degradation of the second stage where the degradation rate is limited. The quenching experiment and electron paramagnetic resonance (EPR) analysis indicated that hydroxyl radical (·OH) and sulfate radical (SO4̇-) were responsible for the abatement of the organic contaminant with ·OH playing a more important role. In summary, this study proposed an environmentally-friendly approach for the application of iron-rich pickling sludge in the remediation of phenol-contaminated water.


Assuntos
Fenol , Esgotos , Catálise , Quelantes , Radical Hidroxila , Ferro
10.
Materials (Basel) ; 15(5)2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35268987

RESUMO

In order to realize the high value-added resource utilization of solid waste and reduce the cost of rubber manufacturing, iron ore tailings (IOTs) were used as raw material to prepare a reinforcing filler of rubber through ultrafine grinding and surface organic modification techniques. We studied the effects of ball mill grinding conditions on the particle size and distribution of grinded iron ore tailings (G-IOTs). The effects of bis-(triethoxy-silyl-propyl)-tetrasulfide (Si69)-modified G-IOT (Si69-G-IOT) loading levels on the cure characteristics, static mechanical and dynamic mechanical properties of the styrene butadiene rubber (SBR) composites were also explored in this paper. The grinding and modification mechanism of IOTs and the combination of filler and SBR matrix were explored by grinding simulation of population balance model, X-ray diffraction analysis, Fourier transform infrared spectroscopy and scanning electron microscopy. The results showed that when grinding IOTs at 2000 r/min for 150 min, the particle size distribution of the resulting G-IOTs was the narrowest, with a D90 value of 4.42 µm. The tensile strength and elongation at break of SBR filled with 120 phr Si69-G-IOT were 14.97 MPa and 596.36%, respectively.

11.
Med Phys ; 48(8): 4375-4386, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34105167

RESUMO

PURPOSE: Chemical shift-encoded magnetic resonance imaging enables accurate quantification of liver fat content though estimation of proton density fat-fraction (PDFF). Computed tomography (CT) is capable of quantifying fat, based on decreased attenuation with increased fat concentration. Current quantitative fat phantoms do not accurately mimic the CT number of human liver. The purpose of this work was to develop and validate an optimized phantom that simultaneously mimics the MRI and CT signals of fatty liver. METHODS: An agar-based phantom containing 12 vials doped with iodinated contrast, and with a granular range of fat fractions was designed and constructed within a novel CT and MR compatible spherical housing design. A four-site, three-vendor validation study was performed. MRI (1.5T and 3T) and CT images were obtained using each vendor's PDFF and CT reconstruction, respectively. An ROI centered in each vial was placed to measure MRI-PDFF (%) and CT number (HU). Mixed-effects model, linear regression, and Bland-Altman analysis were used for statistical analysis. RESULTS: MRI-PDFF agreed closely with nominal PDFF values across both field strengths and all MRI vendors. A linear relationship (slope = -0.54 ± 0.01%/HU, intercept = 37.15 ± 0.03%) with an R2 of 0.999 was observed between MRI-PDFF and CT number, replicating established in vivo signal behavior. Excellent test-retest repeatability across vendors (MRI: mean = -0.04%, 95% limits of agreement = [-0.24%, 0.16%]; CT: mean = 0.16 HU, 95% limits of agreement = [-0.15HU, 0.47HU]) and good reproducibility using GE scanners (MRI: mean = -0.21%, 95% limits of agreement = [-1.47%, 1.06%]; CT: mean = -0.18HU, 95% limits of agreement = [-1.96HU, 1.6HU]) were demonstrated. CONCLUSIONS: The proposed fat phantom successfully mimicked quantitative liver signal for both MRI and CT. The proposed fat phantom in this study may facilitate broader application and harmonization of liver fat quantification techniques using MRI and CT across institutions, vendors and imaging platforms.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Fígado , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
Clin Nucl Med ; 46(1): 8-15, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33234926

RESUMO

PURPOSE: We assessed the prevalence of low bone mineral density (BMD) in oncologic patients undergoing F-FDG PET/CT. PATIENTS AND METHODS: This is a retrospective analysis of 100 patients who underwent F-FDG PET/CT at a single center from October 2015 till May 2016. Quantitative CT (QCT) was used to assess BMD at the lumbar spine (BMDQCT) and femoral necks (BMDCTXA). SUVmax was used to evaluate metabolic activity of the bone marrow. Risk of osteoporosis-related fractures was calculated with femoral neck BMDCTXA and the FRAX algorithm, which was compared against measurements of CT attenuation of the trabecular bone at L1 (L1HU). RESULTS: Osteoporosis and osteopenia were respectively present in 16% and 46% of patients 50 years and older. Bone marrow SUVmax was correlated with BMD at the lumbar spine (ρ = 0.36, P < 0.001). Increased age and low marrow SUVmax were associated with low BMDQCT at the lumbar spine (both P < 0.001), whereas increased age, female sex, and low marrow SUVmax were associated with low BMDCTXA at the femoral necks (P < 0.001, P < 0.001, P = 0.01, respectively). L1HU had an area under the curve of 0.95 (95% confidence interval [CI], 0.90-0.99) for detecting increased risk for osteoporosis-related fracture, with best threshold of 125.8 HU (95% CI, 115.7-144.9) yielding sensitivity of 100% (95% CI, 0.92-1.00), specificity of 0.90 (95% CI, 0.76-0.97), and accuracy of 0.91 (95% CI, 0.79-0.97). CONCLUSIONS: Low BMD is frequent in oncologic patients undergoing F-FDG PET/CT. Decreased F-FDG avidity of the bone marrow correlates with decreased BMD, validating the link between osteoporosis and bone marrow fat. L1HU could be a simple and accurate approach for detecting patients at risk for osteoporosis-related fractures using PET/CTdata.


Assuntos
Densidade Óssea , Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Neoplasias/fisiopatologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Feminino , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Med Phys ; 48(2): 902-911, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33202055

RESUMO

PURPOSE: To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. ACQUISITION AND VALIDATION METHODS: The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low-dose noncontrast chest scans acquired to screen high-risk patients for pulmonary nodules, and contrast-enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise-insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. DATA FORMAT AND USAGE NOTES: Projection datasets were converted into the previously developed DICOM-CT-PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM-CT-PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive (https://doi.org/10.7937/9npb-2637). POTENTIAL APPLICATIONS: This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task-based diagnostic performance.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Tórax , Tomógrafos Computadorizados
15.
Opt Express ; 28(21): 31316-31329, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33115107

RESUMO

A full-color see-through near-eye holographic display is proposed with 80° field of view (FOV) and an expanded eye-box. The system is based on a holographic optical element (HOE) to achieve a large FOV while the image light is focused at the entrance to human pupil and the image of entire field enters human eye. As we know, one of the major limitations of the large FOV holographic display system is the small eye-box that needs to be expanded. We design a double layer diffraction structure for HOE to realize eye-box expansion. The HOE consists of two non-uniform volume holographic gratings and a transparent substrate. Two fabricated holographic gratings are attached to front and back surfaces of the substrate to multiplex image light and achieve eye-box expansion. Simultaneously, the HOE is also manufactured for RGB colors to realize full-color display. The experiment results show that our proposed display system develops 80° round FOV and an enlarged eye-box of 7.5 mm (H) ×5 mm (V) at the same time. The dynamic display ability is also tested in the experiments. The proposed system provides a new solution for the practical application of augmented reality display.

16.
Opt Express ; 28(22): 32709-32720, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114950

RESUMO

The narrow field of view (FOV) has always been one of the most with limitations that drag the development of holographic three-dimensional (3D) near-eye display (NED). The complex amplitude modulation (CAM) technique is one way to realize holographic 3D display in real time with the advantage of high image quality. Previously, we applied the CAM technique on the design and integration of a compact colorful 3D-NED system. In this paper, a viewing angle enlarged CAM based 3D-NED system using a Abbe-Porter scheme and curved reflective structure is proposed. The viewing angle is increased in two steps. An Abbe-Porter filter system, composed of a lens and a grating, is used to enlarge the FOV for the first step and, meanwhile, realize complex amplitude modulation. A curved reflective structure is used to realize the FOV enlargement for the second step. Besides, the system retains the ability of colorful 3D display with high image quality. Optical experiments are performed, and the results show the system could present a 45.2° diagonal viewing angle. The system is able to present dynamic display as well. A compact prototype is fabricated and integrated for wearable and lightweight design.

17.
J Vasc Interv Radiol ; 31(10): 1545-1550.e1, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32861568

RESUMO

PURPOSE: To characterize the accuracy and consistency of fluoroscope dose index reporting and report rates of occupational radiation safety hardware availability and use, trainee participation in procedures, and optional hardware availability at pilot sites for the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR). MATERIALS AND METHODS: Nine institutions participated in the registry pilot, providing fluoroscopic technical and clinical practice data from 38 angiographic C-arm-type fluoroscopes. These data included measurements of the procedure table and mattress transmission factors and accuracy measurements of the reference-point air kerma (Ka,r) and air kerma-area product (PKA). The accuracy of the radiation dose indices were analyzed for variation over time by 1-way analysis of variance (ANOVA). Sites also self-reported information on availability and use of radiation safety hardware, hardware configuration of fluoroscopes, and trainee participation in procedures. RESULTS: All Ka,r and PKA measurements were within the ±35% regulatory limit on accuracy. The mean absolute difference between correction factors for a given system in fluoroscopic and acquisition mode was 0.03 (95% confidence interval, 0.03-0.03). For the 28 fluoroscopic imaging planes that provided data for 3 time points, ANOVA yielded an F value of 0.134 with an F-critical value of 3.109 (P = .875). CONCLUSIONS: This publication provides the technical and clinical framework pertaining to the ACR Fluoroscopy DIR pilot and offers necessary context for future analysis of the clinical procedure radiation-dose data collected.


Assuntos
Exposição Ocupacional , Doses de Radiação , Exposição à Radiação , Monitoramento de Radiação , Radiografia Intervencionista , Fluoroscopia , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Projetos Piloto , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Espalhamento de Radiação , Estados Unidos
18.
Opt Express ; 28(8): 11290-11300, 2020 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-32403643

RESUMO

A curved hologram can increase the view angle in a holographic display. The huge data processing and curved computer-generated hologram (CCGH) computation time is still a challenge for real-time display. Here, we propose two fast methods to accelerate the computation. The first one is a diffraction compensation (DC) method where the diffraction calculation is from the wave-front recording plane (WRP) to a CCGH. The other is an approximate compensation (AC) method that adds a phase difference distribution to the WRP to obtain the CCGH. Numerical simulations and optical experiments are performed, which demonstrate that the two methods are feasible and the computation time is dramatically reduced. The AC method can further reduce time significantly compared with the DC method. And the image quality for proposed methods is similar. It is expected that these fast methods can be combined with curved display screen and flexible display materials in the future.

19.
Med Phys ; 47(7): e881-e912, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32215937

RESUMO

In x-ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x-ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual-energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low- and high-tube potential scans, fast tube-potential switching, beam filtration combined with spiral scanning, dual-source, or dual-layer detector approaches. The use of energy-resolving, photon-counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual-energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast-enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual non-contrast-enhanced images from contrast-enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric acid and non-uric acid urinary stones or uric acid (gout) or non-uric acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagens de Fantasmas , Fótons , Raios X
20.
J Ethnopharmacol ; 254: 112713, 2020 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-32109545

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Zoujin pill (ZJP), a medication used to treat gastrointestinal disorders since the 15th Century in China, have been reported to exert anti-depressant effects in various models. STUDY AIM: To assess the effects of ZJP on gastrointestinal function and depressive behavior in rats under chronic unpredictable mild stress (CUMS), and to examine the underlying mechanisms related to brain-gut axis. METHODS: The rats suffered the stressor once daily for 5 weeks. ZJP (0.6 and 1.2 g/kg) and fluoxetine (15 mg/kg) as positive control were administered to the rats through gastric intubation once daily for 5 consecutive weeks. The anti-depression effects were compared by performing sucrose preference tests and open field tests. Gastrointestinal motility was investigated by determining the gastrointestinal transit rate and by electrogastrogram. The serum levels of the gastrointestinal hormone (GAS, MOT, VIP, SP), inflammatory cytokine (IL-1ß, IL-6; , TNFα) and glucagon-like peptide-1 (GLP-1) were assayed by enzyme-linked immunosorbent assay. For monoamine neurotransmitters (NE, 5-HT, DA), the levels were determined by high-performance liquid chromatography and electrochemical detection in conjunction, which was applied on the samples taken from the hypothalamus, hippocampus, and striatum. RESULTS: The depression-like symptoms among rats under CUMS were significantly relieved by ZJP administration (0.6 and 1.2 g/kg). Gastrointestinal motility was also improved by restoring gastric electrical rhythm and promoting gastrointestinal propulsion. The ZJP at 0.6 g/kg dosage obviously up-regulated 5-HT and DA levels in hippocampus. The ZJP at 1.2 g/kg dosage could increase 5-HT and DA levels in hypothalamus, striatum, and hippocampus, while down-regulated the NE level in hypothalamus and hippocampus. ZJP also reversed the alterations in serum gastrointestinal hormones. Furthermore, treatment with ZJP significantly reduced levels of IL-1ß, IL-6 and TNF-α and increased serum GLP-1 compared with the CUMS group. Fluoxetine also exerted similar anti-depressant effects in the absence of effects on gastrointestinal motility and the levels of serum hormone, inflammatory cytokine and GLP-1. CONCLUSION: ZJP imposed anti-depressant and gastrointestinal regulating functions in rats under CUMS, suggesting potential clinical application. .


Assuntos
Antidepressivos/uso terapêutico , Depressão/tratamento farmacológico , Medicamentos de Ervas Chinesas/uso terapêutico , Intestino Delgado/efeitos dos fármacos , Estresse Psicológico/tratamento farmacológico , Animais , Antidepressivos/farmacologia , Comportamento Animal/efeitos dos fármacos , Monoaminas Biogênicas/metabolismo , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Doença Crônica , Citocinas/sangue , Depressão/sangue , Depressão/fisiopatologia , Medicamentos de Ervas Chinesas/farmacologia , Gastrinas/sangue , Trânsito Gastrointestinal/efeitos dos fármacos , Peptídeo 1 Semelhante ao Glucagon/sangue , Intestino Delgado/fisiologia , Masculino , Motilina/sangue , Ratos Sprague-Dawley , Estresse Psicológico/sangue , Estresse Psicológico/fisiopatologia , Substância P/sangue , Peptídeo Intestinal Vasoativo/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...