1.
Phys Med Biol ; 67(3)2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-35026745

RESUMO

With the integration of treatments with MRI-linacs to the clinical workflow, the understanding and characterization of detector response in reference dosimetry in magnetic fields are required. The external magnetic field perturbs the electron fluence. The degree of perturbation depends on the irradiation conditions and on the detector type. The purpose of this study is to evaluate the magnetic field impact on the electron fluence spectra in several detectors to provide a deeper understanding of detector response in these conditions. Monte Carlo calculations of the electron fluence are performed in six detectors (solid-state: PTW60012 and PTW60019, ionization chambers: PTW30013, PTW31010, PTW31021, and PTW31022) in water and irradiated by a 7 MV FFF photon beam with a small and a reference field, at 0 and 1.5 T. Three chamber axis orientations are investigated: parallel or perpendicular (either the Lorentz force pointing towards the stem or the tip) to the magnetic field and always perpendicular to the photon beam. One orientation for the solid-state detector is studied: parallel to the photon beam and perpendicular to the magnetic field. Additionally, electron fluence spectra are calculated in modified detector geometries to identify the underlying physical mechanisms behind the fluence perturbations. The total electron fluence in the Farmer chamber varies up to 1.24% and 5.12% at 1.5 T, in the parallel and perpendicular orientation, respectively. The interplay between the gyration radius and the Farmer chamber cavity length significantly affects the electron fluence in the perpendicular orientation. For the small-cavity chambers, the maximal variation in total electron fluence is 0.19% in the parallel orientation for the reference field. Significant small-field effects occur in these chambers; the magnetic field reduces the total electron fluence (with respect to the no field case) between 9.86% and 14.50%, depending on the orientation. The magnetic field strongly impacted the solid-state detectors in both field sizes, probably due to the high-Z components and cavity density. The maximal reductions of total electron fluence are 15.06 ± 0.09% (silicon) and 16.00 ± 0.07% (microDiamond). This work provides insights into detector response in magnetic fields by illustrating the interplay between several factors causing dosimetric perturbation effects: (1) chamber and magnetic field orientation, (2) cavity size and shape, (3) extracameral components, (4) air gaps and their asymmetry, (5) electron energy. Low-energy electron trajectories are more susceptible to change in magnetic fields, and are associated with detector response perturbation. Detectors with higher density and high-Z extracameral components exhibit more significant perturbations in the presence of a magnetic field, regardless of field size.


Assuntos
Elétrons , Fótons , Imageamento por Ressonância Magnética , Método de Monte Carlo , Fótons/uso terapêutico , Radiometria/métodos
2.
Phys Med Biol ; 66(22)2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34700311

RESUMO

Objective.With future advances in magnetic resonance imaging-guided radiation therapy, small photon beams are expected to be included regularly in clinical treatments. This study provides physical insights on detector dose-response to multiple megavoltage photon beam sizes coupled to magnetic fields and determines optimal orientations for measurements.Approach.Monte Carlo simulations determine small-cavity detector (solid-state: PTW60012 and PTW60019, ionization chambers: PTW31010, PTW31021, and PTW31022) dose-responses in water to an Elekta Unity 7 MV FFF photon beam. Investigations are performed for field widths between 0.25 and 10 cm in four detector axis orientations with respect to the 1.5 T magnetic field and the photon beam. The magnetic field effect on the overall perturbation factor (PMC) accounting for the extracameral components, atomic composition, and density is quantified in each orientation. The density (Pρ) and volume averaging (Pvol) perturbation factors and quality correction factors (kQB,QfB,f) accounting for the magnetic field are also calculated in each orientation.Main results.Results show thatPvolremains the most significant perturbation both with and without magnetic fields. In most cases, the magnetic field effect onPvolis 1% or less. The magnetic field effect onPρis more significant on ionization chambers than on solid-state detectors. This effect increases up to 1.564 ± 0.001 with decreasing field size for chambers. On the contrary, the magnetic field effect on the extracameral perturbation factor is higher on solid-state detectors than on ionization chambers. For chambers, the magnetic field effect onPMCis only significant for field widths <1 cm, while, for solid-state detectors, this effect exhibits different trends with orientation, indicating that the beam incident angle and geometry play a crucial role.Significance.Solid-state detectors' dose-response is strongly affected by the magnetic field in all orientations. The magnetic field impact on ionization chamber response increases with decreasing field size. In general, ionization chambers yieldkQB,QfB,fcloser to unity, especially in orientations where the chamber axis is parallel to the magnetic field.


Assuntos
Fótons , Radiometria , Campos Magnéticos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Método de Monte Carlo , Fótons/uso terapêutico , Radiometria/métodos
3.
Phys Med Biol ; 66(16)2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-34049290

RESUMO

Magnetic resonance imaging (MRI)-guided radiotherapy (RT) (MRIgRT) falls outside the scope of existing high energy photon therapy dosimetry protocols, because those protocols do not consider the effects of the magnetic field on detector response and on absorbed dose to water. The aim of this study is to evaluate and demonstrate the traceable measurement of absorbed dose in MRIgRT systems using alanine, made possible by the characterisation of alanine sensitivity to magnetic fields reported previously by Billaset al(2020Phys. Med. Biol.65115001), in a way which is compatible with existing standards and calibrations available for conventional RT. In this study, alanine is used to transfer absorbed dose to water to MRIgRT systems from a conventional linac. This offers an alternative route for the traceable measurement of absorbed dose to water, one which is independent of the transfer using ionisation chambers. The alanine dosimetry is analysed in combination with measurements with several Farmer-type chambers, PTW 30013 and IBA FC65-G, at six different centres and two different MRIgRT systems (Elekta Unity™ and ViewRay MRIdian™). The results are analysed in terms of the magnetic field correction factors, and in terms of the absorbed dose calibration coefficients for the chambers, determined at each centre. This approach to reference dosimetry in MRIgRT produces good consistency in the results, across the centres visited, at the level of 0.4% (standard deviation). Farmer-type ionisation chamber magnetic field correction factors were determined directly, by comparing calibrations in some MRIgRT systems with and without the magnetic field ramped up, and indirectly, by comparing calibrations in all the MRIgRT systems with calibrations in a conventional linac. Calibration coefficients in the MRIgRT systems were obtained with a standard uncertainty of 1.1% (Elekta Unity™) and 0.9% (ViewRay MRIdian™), for three different chamber orientations with respect to the magnetic field. The values obtained for the magnetic field correction factor in this investigation are consistent with those presented in the summary by de Pooteret al(2021Phys. Med. Biol.6605TR02), and would tend to support the adoption of a magnetic field correction factor which depends on the chamber type, PTW 30013 or IBA FC65-G.


Assuntos
Alanina , Radiometria , Calibragem , Campos Magnéticos , Imageamento por Ressonância Magnética , Água
4.
Med Phys ; 48(5): 2592-2603, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33525060

RESUMO

PURPOSE: The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS: The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thickness disturbances. The method is applied to EBT3 GafchromicTM film irradiated with cobalt-60 and 6 MV photon beams and digitized with an Epson 10000XL photo scanner. Dose profiles and output factors of different field sizes are measured and analyzed. Variance analysis of the previous method of Bouchard et al. ["On the characterization and uncertainty analysis of radiochromic film dosimetry" Med Phys. 2009;36:1931-1946] is adapted to the new approach. Uncertainties are predicted for relevant applications. RESULTS: Results show that systematic disturbances attributed to thickness variations are efficiently corrected. The method is shown efficient to identify and correct for dark spots which cause systematic errors in single-channel distributions. Applications of the method in the context of relative dosimetry yields standard uncertainties ranging between 0.8% and 1.9%, depending on the region of interest (ROI) size and the film irradiation. Variance analysis predicts that uncertainty levels between 0.3% and 0.6% are achievable with repeated measurements. Uncertainties are found to vary with absorbed dose and ROI size. CONCLUSIONS: The proposed multichannel method is efficient for accurate dosimetry, reaching uncertainty levels comparable to previous publications with EBT film. The method is also promising for applications beyond clinical QA, such as machine characterization and other advanced dosimetry applications.


Assuntos
Dosimetria Fotográfica , Calibragem , Doses de Radiação , Incerteza
5.
Phys Med Biol ; 66(5): 05TR02, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32570225

RESUMO

With the rapid increase in clinical treatments with MRI-linacs, a consistent, harmonized and sustainable ground for reference dosimetry in MRI-linacs is needed. Specific for reference dosimetry in MRI-linacs is the presence of a strong magnetic field. Therefore, existing Code of Practices (CoPs) are inadequate. In recent years, a vast amount of papers have been published in relation to this topic. The purpose of this review paper is twofold: to give an overview and evaluate the existing literature for reference dosimetry in MRI-linacs and to discuss whether the literature and datasets are adequate and complete to serve as a basis for the development of a new or to extend existing CoPs. This review is prefaced with an overview of existing MRI-linac facilities. Then an introduction on the physics of radiation transport in magnetic fields is given. The main part of the review is devoted to the evaluation of the literature with respect to the following subjects: • beam characteristics of MRI-linac facilities; • formalisms for reference dosimetry in MRI-linacs; • characteristics of ionization chambers in the presence of magnetic fields; • ionization chamber beam quality correction factors; and • ionization chamber magnetic field correction factors. The review is completed with a discussion as to whether the existing literature is adequate to serve as basis for a CoP. In addition, it highlights subjects for future research on this topic.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Aceleradores de Partículas , Radiometria/normas , Humanos , Campos Magnéticos , Padrões de Referência
6.
Phys Med Biol ; 65(24): 245008, 2020 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-32674077

RESUMO

In MRgRT, dosimetry measurements are performed in the presence of magnetic fields. For high-resolution measurements, small-cavity ionization chambers are required. While Monte Carlo simulations are essential to determine dosimetry correction factors, models of small-chambers require careful validation with experimental measurements. The aim of this study is to characterize small-cavity chamber response coupled to magnetic fields. Small-cavity chambers (PTW31010, PTW31016, PTW31021 and PTW3022) are irradiated by a 6 MV photon beam for 9 magnetic field strengths between -1.5 T and +1.5 T. The chamber axis is orientated either parallel or perpendicular to the irradiation beam, with the magnetic field always perpendicular to the beam. MC simulations are performed in EGSnrc. The sensitive volume of the chambers is reduced to account for the inefficiency adjacent to the guard electrode (dead volume) based on COMSOL calculations of electric potentials. The magnetic field affects the chamber response by up to 4.1% and 4.5% in the parallel and perpendicular orientations, respectively, compared to no magnetic field. The maximal difference in dose response between experiments and simulations is up to 6.1% and 4.5% for parallel and perpendicular orientation, respectively. When the dead volume is removed, which accounts for the 15%-23% of the nominal volume, the difference, in most cases, is within the stated uncertainties. Nevertheless, for a particular chamber, the reduced nominal volume barely improved the agreement between the experimental and calculated relative response (4.53% to 4.13%). This disagreement may be due to the imperfect chamber geometry model, as was found from microCT images. A detailed uncertainty analysis is presented. The characterization of small-cavity ion chamber response coupled to magnetic fields is complex. Small differences between real and model chamber geometry that normally would be insignificant become an issue in the presence of magnetic fields. Accurate characterization of the nominal volume is essential for small-cavity ion chamber modelling.


Assuntos
Campos Magnéticos , Fótons , Radiometria/instrumentação , Eletricidade , Humanos , Método de Monte Carlo , Incerteza
7.
Phys Med Biol ; 65(19): 195006, 2020 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-32503026

RESUMO

The 1990 code of practice (COP), produced by the IPSM (now the Institute of Physics and Engineering in Medicine, IPEM) and the UK National Physical Laboratory (NPL), gave instructions for determining absorbed dose to water for megavoltage photon (MV) radiotherapy beams (Lillicrap et al 1990). The simplicity and clarity of the 1990 COP led to widespread uptake and high levels of consistency in external dosimetry audits. An addendum was published in 2014 to include the non-conventional conditions in Tomotherapy units. However, the 1990 COP lacked detailed recommendations for calibration conditions, and the corresponding nomenclature, to account for modern treatment units with different reference fields, including small fields as described in IAEA TRS483 (International Atomic Energy Agency (IAEA) 2017, Vienna). This updated COP recommends the irradiation geometries, the choice of ionisation chambers, appropriate correction factors and the derivation of absorbed dose to water calibration coefficients, for carrying out reference dosimetry measurements on MV external beam radiotherapy machines. It also includes worked examples of application to different conditions. The strengths of the 1990 COP are retained: recommending the NPL2611 chamber type as secondary standard; the use of tissue phantom ratio (TPR) as the beam quality specifier; and NPL-provided direct calibration coefficients for the user's chamber in a range of beam qualities similar to those in clinical use. In addition, the formalism is now extended to units that cannot achieve the standard reference field size of 10 cm × 10 cm, and recommendations are given for measuring dose in non-reference conditions. This COP is designed around the service that NPL provides and thus it does not require the range of different options presented in TRS483, such as generic correction factors for beam quality. This approach results in a significantly simpler, more concise and easier to follow protocol.


Assuntos
Calibragem/normas , Imagens de Fantasmas , Fótons/uso terapêutico , Radiometria/métodos , Radiometria/normas , Radioterapia de Alta Energia/normas , Humanos , Agências Internacionais , Dosagem Radioterapêutica , Água
8.
Phys Med Biol ; 65(11): 115001, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32191920

RESUMO

Reference dosimetry in the presence of a strong magnetic field is challenging. Ionisation chambers have shown to be strongly affected by magnetic fields. There is a need for robust and stable detectors in MRI-guided radiotherapy (MRIgRT). This study investigates the behaviour of the alanine dosimeter in magnetic fields and assesses its suitability to act as a reference detector in MRIgRT. Alanine pellets were loaded in a waterproof holder, placed in an electromagnet and irradiated by 60Co and 6 MV and 8 MV linac beams over a range of magnetic flux densities. Monte Carlo simulations were performed to calculate the absorbed dose, to water and to alanine, with and without magnetic fields. Combining measurements with simulations, the effect of magnetic fields on alanine response was quantified and a correction factor for the presence of magnetic fields on alanine was determined. This study finds that the response of alanine to ionising radiation is modified when the irradiation is in the presence of a magnetic field. The effect is energy independent and may increase the alanine/electron paramagnetic resonance (EPR) signal by 0.2% at 0.35 T and 0.7% at 1.5 T. In alanine dosimetry for MRIgRT, this effect, if left uncorrected, would lead to an overestimate of dose. Accordingly, a correction factor, [Formula: see text], is defined. Values are obtained for this correction as a function of magnetic flux density, with a standard uncertainty which depends on the magnetic field and is 0.6% or less. The strong magnetic field has a measurable effect on alanine dosimetry. For alanine which is used to measure absorbed dose to water in a strong magnetic field, but which has been calibrated in the absence of a magnetic field, a small correction to the reported dose is required. With the inclusion of this correction, alanine/EPR is a suitable reference dosimeter for measurements in MRIgRT.


Assuntos
Alanina , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Dosímetros de Radiação/normas , Radioterapia/métodos , Calibragem , Radioisótopos de Cobalto , Método de Monte Carlo , Aceleradores de Partículas , Radiometria/métodos , Radioterapia/instrumentação
10.
Phys Med Biol ; 64(6): 06NT03, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30731443

RESUMO

With the advent of MRI-guided radiotherapy, the suitability of commercially available radiation dose detectors needs to be assessed. The aim of this study was to investigate the effect of the magnetic field (B-field) on the response of the Gafchromic EBT-3 films. Moreover, as an independent study, we contribute to clarifying the inconsistency of the results of recent published studies, on the effect of B-field on the sensitivity of Gafchromic films. A 60Co beam was used to irradiate film samples in an electromagnet. An in-house PMMA phantom was designed to fit in the 5 cm gap between the two poles of the magnet. The phantom consists of two symmetrical plates where a film can be inserted. The absorbed dose rate of the 60Co beam for zero B-field was measured using alanine pellets in a Farmer-type holder. A 12-point response curve was created, representing [Formula: see text] as a function of dose, for each of five different B-field strengths (0 T to 2 T). This study finds that there is at most a small effect of the magnetic field on the response of EBT-3 film. In terms of netOD (red channel) the change in response varied from ‒0.0011 at 0.5 T to 0.0045 at 2.0 T, with a standard uncertainty of 0.0030. If uncorrected, this would lead to an error in film-measured dose, for the red channel, of 2.4% at 2 T, with a standard uncertainty on dose of 1.4%. Results are also presented for B-field strengths of 0.5 T, 1 T and 1.5 T, which are all zero within the measurement uncertainty. Comparison between other studies is also presented. Considering the small change on dose determined with EBT-3 when irradiated under the presence of B-field and taking into account the overall uncertainty in dosimetry using EBT-3 film achieved in this work, EBT-3 is assessed to be a suitable detector for relative and absolute dosimetry, with appropriate corrections, in MRI-guided radiotherapy. The results of the current work also elucidate the inconsistency on the reports from previous studies and demonstrate the necessity of similar investigations by independent teams, especially if the existing results may be in conflict.


Assuntos
Radioisótopos de Cobalto , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Campos Magnéticos , Imagens de Fantasmas , Humanos , Doses de Radiação , Incerteza
11.
Phys Med Biol ; 63(5): 05NT01, 2018 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-29393066

RESUMO

Dosimetric quality assurance (QA) of the new Elekta Unity (MR-linac) will differ from the QA performed of a conventional linac due to the constant magnetic field, which creates an electron return effect (ERE). In this work we aim to validate PRESAGE® dosimetry in a transverse magnetic field, and assess its use to validate the research version of the Monaco TPS of the MR-linac. Cylindrical samples of PRESAGE® 3D dosimeter separated by an air gap were irradiated with a cobalt-60 unit, while placed between the poles of an electromagnet at 0.5 T and 1.5 T. This set-up was simulated in EGSnrc/Cavity Monte Carlo (MC) code and relative dose distributions were compared with measurements using 1D and 2D gamma criteria of 3% and 1.5 mm. The irradiation conditions were adapted for the MR-linac and compared with Monaco TPS simulations. Measured and EGSnrc/Cavity simulated profiles showed good agreement with a gamma passing rate of 99.9% for 0.5 T and 99.8% for 1.5 T. Measurements on the MR-linac also compared well with Monaco TPS simulations, with a gamma passing rate of 98.4% at 1.5 T. Results demonstrated that PRESAGE® can accurately measure dose and detect the ERE, encouraging its use as a QA tool to validate the Monaco TPS of the MR-linac for clinically relevant dose distributions at tissue-air boundaries.


Assuntos
Campos Magnéticos , Método de Monte Carlo , Imagens de Fantasmas , Dosímetros de Radiação/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Raios gama , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica
12.
Phys Med Biol ; 61(23): 8360-8394, 2016 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-27819253

RESUMO

Flattening filter free (FFF) beams are now commonly available with new standard linear accelerators. These beams have recognised clinical advantages in certain circumstances, most notably the reduced beam-on times for high dose per fraction stereotactic treatments. Therefore FFF techniques are quickly being introduced into clinical use. The purpose of this report is to provide practical implementation advice and references for centres implementing FFF beams clinically. In particular UK-specific guidance is given for reference dosimetry and radiation protection.


Assuntos
Filtração/normas , Aceleradores de Partículas/normas , Guias de Prática Clínica como Assunto/normas , Proteção Radiológica/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/normas , Filtração/instrumentação , Humanos , Aceleradores de Partículas/instrumentação , Proteção Radiológica/instrumentação , Radiometria/métodos , Radioterapia de Intensidade Modulada/instrumentação , Reino Unido
13.
Med Phys ; 42(10): 6033-47, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26429279

RESUMO

PURPOSE: To explain the reasons for significant quality correction factors in megavoltage small photon fields and clarify the underlying concepts relevant to dosimetry under such conditions. METHODS: The validity of cavity theory and the requirement of charged particle equilibrium (CPE) are addressed from a theoretical point of view in the context of nonstandard beams. Perturbation effects are described into four main subeffects, explaining their nature and pointing out their relative importance in small photon fields. RESULTS: It is demonstrated that the failure to meet classical cavity theory requirements, such as CPE, is not the reason for significant quality correction factors. On the contrary, it is shown that the lack of CPE alone cannot explain these corrections and that what matters most, apart from volume averaging effects, is the relationship between the lack of CPE in the small field itself and the density of the detector cavity. The density perturbation effect is explained based on Fano's theorem, describing the compensating effect of two main contributions to cavity absorbed dose. Using the same approach, perturbation effects arising from the difference in atomic properties of the cavity medium and the presence of extracameral components are explained. Volume averaging effects are also discussed in detail. CONCLUSIONS: Quality correction factors of small megavoltage photon fields are mainly due to differences in electron density between water and the detector medium and to volume averaging over the detector cavity. Other effects, such as the presence of extracameral components and differences in atomic properties of the detection medium with respect to water, can also play an accentuated role in small photon fields compared to standard beams.


Assuntos
Fótons , Radiometria/métodos , Método de Monte Carlo
14.
Med Phys ; 42(10): 6048-61, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26429280

RESUMO

PURPOSE: To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS: In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano's theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. RESULTS: Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. CONCLUSIONS: Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.


Assuntos
Fótons , Radiometria/métodos , Método de Monte Carlo
15.
Phys Med Biol ; 60(17): 6639-54, 2015 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-26271015

RESUMO

With the advent of MRI-guided radiotherapy, reference dosimetry must be thoroughly addressed to account for the effects of the magnetic field on absorbed dose to water and on detector dose response. While Monte Carlo plays an essential role in reference dosimetry, it is also crucial for determining quality correction factors in these new conditions. The Fano cavity test is recognized as fundamental to validate Monte Carlo transport algorithms. In the presence of magnetic fields, it is necessary to define special conditions under which such a test can be performed. The present theoretical study proposes two conditions in which the validity of Fano's theorem is demonstrated in the presence of a magnetic field and the analytic expression of energy deposition is verified. It is concluded that the proposed conditions form a valid basis for two types of Fano cavity tests in the presence of a magnetic field.


Assuntos
Algoritmos , Campos Magnéticos , Radiometria/normas , Imageamento por Ressonância Magnética , Método de Monte Carlo , Radioterapia Guiada por Imagem , Valores de Referência
16.
Appl Radiat Isot ; 70(7): 1154-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22365112

RESUMO

EPID dosimetry has known drawbacks. The main issue is that a measurable residual signal is observed after the end of irradiation for prolonged periods of time, thus making measurement difficult. We present a detailed analysis of EPID response and suggest a simple, yet accurate approach for calibration that avoids the complexity of incorporating ghosting and image-lag using the maximum integrated signal instead of the total integrated signal. This approach is linear with dose and independent of dose rate.

17.
Phys Med Biol ; 49(16): 3737-49, 2004 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-15446802

RESUMO

Calorimetry has been recommended and performed in proton beams for some time, but never has graphite calorimetry been used as a reference dosimeter in clinical proton beams. Furthermore, only a few calorimetry measurements have been reported in ocular proton beams. In this paper we describe the construction and performance of a small-body portable graphite calorimeter for clinical low-energy proton beams. Perturbation correction factors for the gap effect, volume averaging effect, heat transfer phenomena and impurity effect are calculated and applied in a comparison with ionization chamber dosimetry following IAEA TRS-398. The ratio of absorbed dose to water obtained from the calorimeter measurements and from the ionization measurements varied between 0.983 and 1.019, depending on the beam type and the ionization chamber calibration modality. Standard uncertainties on these values varied between 1.9% and 2.5% including a substantial contribution from the kQ values in IAEA TRS-398. The (Wair/e)p values inferred from these measurements varied between 33.6 J C(-1) and 34.9 J C(-1) with similar standard uncertainties. A number of improvements for the small-body portable graphite calorimeter and the experimental set-up are suggested for potential reduction of the uncertainties.


Assuntos
Calorimetria/instrumentação , Calorimetria/métodos , Grafite/uso terapêutico , Prótons , Radiometria/métodos , Calibragem , Humanos , Íons , Modelos Estatísticos , Método de Monte Carlo , Aceleradores de Partículas , Fótons , Radiação Ionizante , Dosagem Radioterapêutica , Água