Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
ACS Omega ; 9(3): 3262-3275, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38284094

RESUMO

The ability of the centrifugal Lab-on-a-Disc (LoaD) platform to closely mimic the "on bench" liquid handling steps (laboratory unit operations (LUOs)) such as metering, mixing, and aliquoting supports on-disc automation of bioassay without the need for extensive biological optimization. Thus, well-established bioassays, normally conducted manually using pipettes or using liquid handling robots, can be relatively easily automated in self-contained microfluidic chips suitable for use in point-of-care or point-of-use settings. The LoaD's ease of automation is largely dependent on valves that can control liquid movement on the rotating disc. The optimum valving strategy for a true low-cost and portable device is rotationally actuated valves, which are actuated by changes in the disc spin-speed. However, due to tolerances in disc manufacturing and variations in reagent properties, most of these valving technologies have inherent variation in their actuation spin-speed. Most valves are actuated through stepped increases in disc spin-speed until the motor reaches its maximum speed (rarely more than 6000 rpm). These manufacturing tolerances combined with this "analogue" mechanism of valve actuation limits the number of LUOs that can be placed on-disc. In this work, we present a novel valving mechanism called low-high-low serial dissolvable film (DF) valves. In these valves, a DF membrane is placed in a dead-end pneumatic chamber. Below an actuation spin-speed, the trapped air prevents liquid wetting and dissolving the membrane. Above this spin-speed, the liquid will enter and wet the DF and open the valve. However, as DFs take ∼40 s to dissolve, the membrane can be wetted, and the disc spin-speed reduced before the film opens. Thus, by placing valves in a series, we can govern on which "digital pulse" in spin-speeding a reagent is released; a reservoir with one serial valve will open on the first pulse, a reservoir with two serial valves on the second, and so on. This "digital" flow control mechanism allows the automation of complex assays with high reliability. In this work, we first describe the operation of the valves, outline the theoretical basis for their operation, and support this analysis with an experiment. Next, we demonstrate how these valves can be used to automate the solid-phase extraction of DNA on on-disc LAMP amplification for applications in plant pathogen detection. The disc was successfully used to extract and detect, from a sample lysed off-disc, DNA indicating the presence of thermally inactivated Clavibacter michiganensis ssp. michiganensis (Cmm), a bacterial pathogen on tomato leaf samples.

2.
Anal Chim Acta ; 1288: 342159, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220291

RESUMO

BACKGROUND: Biomedical diagnostic and lab automation solutions built on the Lab-on-a-Disc (LoaD) platform has great potential due to their independence from specialised micro-pumps and their ease of integration, through direct pipetting, with manual or automated workflows. However, a challenge for all microfluidic chips is their cost of manufacture when each microfluidic disc must be customized for a specific application. In this paper, we present centrifugal discs with programmable fluidic networks. RESULTS: Based on dissolvable film valves, we present two technologies. The first, based on recently introduced pulse-actuated dissolvable film valves, is a centrifugal disc which, depending on how it is loaded, is configured to perform either six sequential reagent releases through one reaction chamber or three sequential reagent releases through two reaction chambers. In the second approach, we use the previously introduced electronic Lab-on-a-Disc (eLoaD) wireless valve array, which can actuate up to 128 centrifugo-pneumatic dissolvable film valves in a pre-defined sequence. In this approach we present a disc which can deliver any one of 8 reagent washes to any one of four reaction chambers. We use identical discs to demonstrate the first four sequential washes through two reaction chambers and then two sequential washes through four reaction chambers. SIGNIFICANCE: These programmable fluidic networks have the potential to allow a single disc architecture to be applied to multiple different assay types and so can offer a lower-cost and more integrated alternative to the standard combination of micro-titre plate and liquid handling robot. Indeed, it may even be possible to conduct multiple different assays concurrently. This can have the effect of reducing manufacturing costs and streamlining supply-chains and so results in a more accessible diagnostic platform.

3.
Micromachines (Basel) ; 14(12)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38138426

RESUMO

Sample preparation for mass spectroscopy typically involves several liquid and solid phase clean-ups, extractions, and other unit operations, which are labour-intensive and error-prone. We demonstrate a centrifugal microfluidic platform that automates the whole blood sample's preparation and clean-up by combining traditional liquid-phase and multiple solid-phase extractions for applications in mass spectroscopy (MS)-based small molecule detection. Liquid phase extraction was performed using methanol to precipitate proteins in plasma separated from a blood sample under centrifugal force. The preloaded solid phase composed of C18 beads then removed lipids with a combination of silica particles, which further cleaned up any remaining proteins. We further integrated the application of this sample prep disc with matrix-assisted laser desorption/ionization (MALDI) MS by using glancing angle deposition films, which further cleaned up the processed sample by segregating the electrolyte background from the sample salts. Additionally, hydrophilic interaction liquid chromatography (HILIC) MS was employed for detecting targeted free amino acids. Therefore, several representative ionic metabolites, including several amino acids and organic acids from blood samples, were analysed by both MALDI-MS and HILIC-MS to demonstrate the performance of this sample preparation disc. The fully automated blood sample preparation procedure only took 35 mins, with a throughput of three parallel units.

4.
PLoS One ; 18(9): e0291165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37682949

RESUMO

Due to their capability for comprehensive sample-to-answer automation, the interest in centrifugal microfluidic systems has greatly increased in industry and academia over the last quarter century. The main applications of these "Lab-on-a-Disc" (LoaD) platforms are in decentralised bioanalytical point-of-use / point-of-care testing. Due to the unidirectional and omnipresent nature of the centrifugal force, advanced flow control is key to coordinate multi-step / multi-reagent assay formats on the LoaD. Formerly, flow control was often achieved by capillary burst valves which require gradual increments of the spin speed of the system-innate spindle motor. Recent advanced introduced a flow control scheme called 'rotational pulse actuated valves'. In these valves the sequence of valve actuation is determined by the architecture of the disc while actuation is triggered by freely programmable upward spike (i.e. Low-High-Low (LHL)) in the rotational frequency. This paradigm shift from conventional 'analogue' burst valves to 'digital' pulsing significantly increases the number of sequential while also improving the overall robustness of flow control. In this work, we expand on these LHL valves by introducing High-Low-High (HLH) pulse-actuated (PA) valving which are actuated by 'downward' spike in the disc spin-rate. These HLH valves are particularly useful for high spin-rate operations such as centrifugation of blood. We introduce two different HLH architectures and then combine the most promising with LHL valves to implement the time-dependent liquid handling protocol underlying a common liver function test panel.


Assuntos
Bradicardia , Taquicardia , Humanos , Frequência Cardíaca , Aceleração , Automação
5.
Anal Chim Acta ; 1258: 341070, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37087288

RESUMO

By virtue of its ruggedness, portability, rapid processing times, and ease-of-use, academic and commercial interest in centrifugal microfluidic systems has soared over the last decade. A key advantage of the LoaD platform is the ability to automate laboratory unit operations (LUOs) (mixing, metering, washing etc.) to support direct translation of 'on-bench' assays to 'on-chip'. Additionally, the LoaD requires just a low-cost spindle motor rather than specialized and expensive microfluidic pumps. Furthermore, when flow control (valves) is implemented through purely rotational changes in this same spindle motor (rather than using additional support instrumentation), the LoaD offers the potential to be a truly portable, low-cost and accessible platform. Current rotationally controlled valves are typically opened by sequentially increasing the disc spin-rate to a specific opening frequency. However, due lack of manufacturing fidelity these specific opening frequencies are better described as spin frequency 'bands'. With low-cost motors typically having a maximum spin-rate of 6000 rpm (100 Hz), using this 'analogue' approach places a limitation on the number of valves, which can be serially actuated thus limiting the number of LUOs that can be automated. In this work, a novel flow control scheme is presented where the sequence of valve actuation is determined by architecture of the disc while its timing is governed by freely programmable 'digital' pulses in its spin profile. This paradigm shift to 'digital' flow control enables automation of multi-step assays with high reliability, with full temporal control, and with the number of LUOs theoretically only limited by available space on the disc. We first describe the operational principle of these valves followed by a demonstration of the capability of these valves to automate complex assays by screening tomato leaf samples against plant pathogens. Reagents and lysed sample are loaded on-disc and then, in a fully autonomous fashion using only spindle-motor control, the complete assay is automated. Amplification and fluorescent acquisition take place on a custom spin-stand enabling the generation of real-time LAMP amplification curves using custom software. To prevent environmental contamination, the entire discs are sealed from atmosphere following loading with internal venting channels permitting easy movement of liquids about the disc. The disc was successfully used to detect the presence of thermally inactivated Clavibacter michiganensis. Michiganensis (CMM) bacterial pathogen on tomato leaf samples.


Assuntos
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , Técnicas de Amplificação de Ácido Nucleico , Reprodutibilidade dos Testes , Extração em Fase Sólida , Doenças das Plantas
6.
Biomicrofluidics ; 15(6): 064102, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34804316

RESUMO

In this paper, we present a centrifugal microfluidic concept employing event-triggered valving for automated extraction of metered plasma and peripheral blood mononuclear cells (PBMCs). This "lab-on-a-disk" system has been developed for retrieving different density layers from a liquid column by "overflowing" the layers sequentially using the pressure exerted by a density-gradient liquid. Defined volumes of plasma and PBMCs were efficiently forwarded into designated microfluidic chambers as a sample preparation step prior to further downstream processing. Furthermore, the extracted PBMCs were counted directly on-disk using an automated optical unit by object-based image analysis, thus eliminating the requirement for the post-processing of the extracted PBMCs. This study is a direct continuation of our previous work1 where we demonstrated combined on-disk detection of C-reactive protein and quantification of PBMCs following on-disk extraction of plasma and PBMCs from a single blood sample using a centrifugo-pneumatic valving mechanism. However, the former valving technique featured limited PBMC extraction efficiency. Here, integrating the novel concept along with event-triggered valving mechanism, we eliminated the occurrence of a specific microfluidic effect, which led us to increase PBMC extraction efficiency to 88%. This extraction method has the potential to be utilized for efficiently separating multiple density layers from a liquid sample in relevant biomedical applications.

7.
Micromachines (Basel) ; 12(6)2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34203926

RESUMO

Fluidic larger-scale integration (LSI) resides at the heart of comprehensive sample-to-answer automation and parallelization of assay panels for frequent and ubiquitous bioanalytical testing in decentralized point-of-use/point-of-care settings. This paper develops a novel "digital twin" strategy with an emphasis on rotational, centrifugo-pneumatic flow control. The underlying model systematically connects retention rates of rotationally actuated valves as a key element of LSI to experimental input parameters; for the first time, the concept of band widths in frequency space as the decisive quantity characterizing operational robustness is introduced, a set of quantitative performance metrics guiding algorithmic optimization of disc layouts is defined, and the engineering principles of advanced, logical flow control and timing are elucidated. Overall, the digital twin enables efficient design for automating multiplexed bioassay protocols on such "Lab-on-a-Disc" (LoaD) systems featuring high packing density, reliability, configurability, modularity, and manufacturability to eventually minimize cost, time, and risk of development and production.

8.
Biosensors (Basel) ; 11(3)2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33800811

RESUMO

Within microfluidic technologies, the centrifugal microfluidic "Lab-on-a-Disc" (LoaD) platform offers great potential for use at the PoC and in low-resource settings due to its robustness and the ability to port and miniaturize 'wet bench' laboratory protocols. We present the combination of 'event-triggered dissolvable film valves' with a centrifugo-pneumatic siphon structure to enable control and timing, through changes in disc spin-speed, of the release and incubations of eight samples/reagents/wash buffers. Based on these microfluidic techniques, we integrated and automated a chemiluminescent immunoassay for detection of the CVD risk factor marker C-reactive protein displaying a limit of detection (LOD) of 44.87 ng mL-1 and limit of quantitation (LoQ) of 135.87 ng mL-1.


Assuntos
Proteína C-Reativa/análise , Dispositivos Lab-On-A-Chip , Automação , Biomarcadores/análise , Doenças Cardiovasculares/metabolismo , Desenho de Equipamento , Humanos , Laboratórios , Limite de Detecção , Técnicas Analíticas Microfluídicas , Microfluídica
9.
Stem Cell Rev Rep ; 17(5): 1713-1740, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33730327

RESUMO

A hallmark of subclinical atherosclerosis is the accumulation of vascular smooth muscle cell (SMC)-like cells leading to intimal thickening and lesion formation. While medial SMCs contribute to vascular lesions, the involvement of resident vascular stem cells (vSCs) remains unclear. We evaluated single cell photonics as a discriminator of cell phenotype in vitro before the presence of vSC within vascular lesions was assessed ex vivo using supervised machine learning and further validated using lineage tracing analysis. Using a novel lab-on-a-Disk(Load) platform, label-free single cell photonic emissions from normal and injured vessels ex vivo were interrogated and compared to freshly isolated aortic SMCs, cultured Movas SMCs, macrophages, B-cells, S100ß+ mVSc, bone marrow derived mesenchymal stem cells (MSC) and their respective myogenic progeny across five broadband light wavelengths (λ465 - λ670 ± 20 nm). We found that profiles were of sufficient coverage, specificity, and quality to clearly distinguish medial SMCs from different vascular beds (carotid vs aorta), discriminate normal carotid medial SMCs from lesional SMC-like cells ex vivo following flow restriction, and identify SMC differentiation of a series of multipotent stem cells following treatment with transforming growth factor beta 1 (TGF- ß1), the Notch ligand Jagged1, and Sonic Hedgehog using multivariate analysis, in part, due to photonic emissions from enhanced collagen III and elastin expression. Supervised machine learning supported genetic lineage tracing analysis of S100ß+ vSCs and identified the presence of S100ß+vSC-derived myogenic progeny within vascular lesions. We conclude disease-relevant photonic signatures may have predictive value for vascular disease.


Assuntos
Músculo Liso Vascular , Óptica e Fotônica , Proteínas Hedgehog , Músculo Liso Vascular/citologia , Músculo Liso Vascular/metabolismo , Músculo Liso Vascular/patologia , Subunidade beta da Proteína Ligante de Cálcio S100/metabolismo , Células-Tronco/metabolismo
10.
Microsyst Nanoeng ; 7: 104, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34987859

RESUMO

Current, application-driven trends towards larger-scale integration (LSI) of microfluidic systems for comprehensive assay automation and multiplexing pose significant technological and economical challenges to developers. By virtue of their intrinsic capability for powerful sample preparation, centrifugal systems have attracted significant interest in academia and business since the early 1990s. This review models common, rotationally controlled valving schemes at the heart of such "Lab-on-a-Disc" (LoaD) platforms to predict critical spin rates and reliability of flow control which mainly depend on geometries, location and liquid volumes to be processed, and their experimental tolerances. In absence of larger-scale manufacturing facilities during product development, the method presented here facilitates efficient simulation tools for virtual prototyping and characterization and algorithmic design optimization according to key performance metrics. This virtual in silico approach thus significantly accelerates, de-risks and lowers costs along the critical advancement from idea, layout, fluidic testing, bioanalytical validation, and scale-up to commercial mass manufacture.

11.
Lab Chip ; 21(1): 9-21, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33289737

RESUMO

Worldwide, the microfluidics industry has grown steadily over the last 5 years, with the market for microfluidic medical devices experiencing a compound growth rate of 22%. The number of submissions of microfluidic-based devices to regulatory agencies such as the U.S. Food & Drug Administration (FDA) has also steadily increased, creating a strong demand for the development of consistent and accessible tools for evaluating microfluidics-based devices. The microfluidics community has been slow, or even reluctant, to adopt standards and guidelines, which are needed for harmonization and for assisting academia, researchers, designers, and industry across all stages of product development. Appropriate assessments of device performance also remain a bottleneck for microfluidic devices. Standards reside at the core of mature supply chains generating economies of scale and forging a consistent pathway to match stakeholder expectations, thus creating a foundation for successful commercialization. This article provides a unique perspective on the need for the development of standards specific to the emerging biomedical field of microfluidics. Our aim is to facilitate innovation by encouraging the microfluidics community to work together to help bridge knowledge gaps and improve efficiency in getting high-quality microfluidic medical devices to market faster. We start by acknowledging the progress that has been made in various areas over the past decade. We then describe the existing gaps in the standardization of flow control, interconnections, component integration, manufacturing, assembly, packaging, reliability, performance of microfluidic elements and safety testing of microfluidic devices throughout the entire product life cycle.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica , Padrões de Referência , Reprodutibilidade dos Testes
12.
Micromachines (Basel) ; 10(12)2019 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-31861126

RESUMO

The majority of commercially oriented microfluidic technologies provide novel point-of-use solutions for laboratory automation with important areas in the context of the life sciences such as health care, biopharma, veterinary medicine and agrifood as well as for monitoring of the environment, infrastructures and industrial processes. Such systems are often composed of a modular setup exhibiting an instrument accommodating rather conventional actuation, detection and control units which interfaces with a fluidically integrated "Lab-on-a-Chip" device handling (bio-)sample(s) and reagents. As the complex network of tiny channels, chambers and surface-functionalised zones can typically not be properly cleaned and regenerated, these microfluidic chips are mostly devised as single-use disposables. The availability of cost-efficient materials and associated structuring, functionalisation and assembly schemes thus represents a key ingredient along the commercialisation pipeline and will be a first focus of this work. Furthermore, and owing to their innate variability, investigations on biosamples mostly require the acquisition of statistically relevant datasets. Consequently, intermediate numbers of consistently performing chips are already needed during application development; to mitigate the potential pitfalls of technology migration and to facilitate regulatory compliance of the end products, manufacture of such pilot series should widely follow larger-scale production schemes. To expedite and de-risk the development of commercially relevant microfluidic systems towards high Technology Readiness Levels (TRLs), we illustrate a streamlined, manufacturing-centric platform approach employing the paradigms of tolerance-forgiving Design-for-Manufacture (DfM) and Readiness for Scale-up (RfS) from prototyping to intermediate pilot series and eventual mass fabrication. Learning from mature industries, we further propose pursuing a platform approach incorporating aspects of standardisation in terms of specification, design rules and testing methods for materials, components, interfaces, and operational procedures; this coherent strategy will foster the emergence of dedicated commercial supply chains and also improve the economic viability of Lab-on-a-Chip systems often targeting smaller niche markets by synergistically bundling technology development.

13.
Sci Rep ; 9(1): 4157, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30858536

RESUMO

Cellular activation and inflammation leading to endothelial dysfunction is associated with cardiovascular disease (CVD). We investigated whether a single cell label-free multi parameter optical interrogation system can detect endothelial cell and endothelial progenitor cell (EPC) activation in vitro and ex vivo, respectively. Cultured human endothelial cells were exposed to increasing concentrations of tumour necrosis factor alpha (TNF-α) or lipopolysaccharide (LPS) before endothelial activation was validated using fluorescence-activated cell sorting (FACS) analysis of inflammatory marker expression (PECAM-1, E-selectin and ICAM-1). A centrifugal microfluidic system and V-cup array was used to capture individual cells before optical measurement of light scattering, immunocytofluorescence, auto-fluorescence (AF) and cell morphology was determined. In vitro, TNF-α promoted specific changes to the refractive index and cell morphology of individual cells concomitant with enhanced photon activity of fluorescently labelled inflammatory markers and increased auto-fluorescence (AF) intensity at three different wavelengths, an effect blocked by inhibition of downstream signalling with Iκß. Ex vivo, there was a significant increase in EPC number and AF intensity of individual EPCs from CVD patients concomitant with enhanced PECAM-1 expression when compared to normal controls. This novel label-free 'lab on a disc' (LoaD) platform can successfully detect endothelial activation in response to inflammatory stimuli in vitro and ex vivo.


Assuntos
Citometria de Fluxo/métodos , Células Endoteliais da Veia Umbilical Humana/citologia , Forma Celular , Selectina E/genética , Selectina E/metabolismo , Citometria de Fluxo/instrumentação , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Molécula 1 de Adesão Intercelular/genética , Molécula 1 de Adesão Intercelular/metabolismo , Lipopolissacarídeos/farmacologia , Molécula-1 de Adesão Celular Endotelial a Plaquetas/genética , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Fator de Necrose Tumoral alfa/farmacologia
14.
Biotechnol J ; 14(3): e1800219, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29989353

RESUMO

With the ability to affect multiple genes and fundamental pathways simultaneously, miRNA engineering of Chinese Hamster Ovary (CHO) cells has significant advantages over single gene expression or repression. Tight control of these molecular triggers is desirable as it could in theory allow on/off or even tunable regulation of desirable cellular phenotypes. The present study investigated the potential of employing a tetracycline inducible (TET-On) system for conditional knockdown of specific miRNAs but encountered several challenges. The authors show a significant reduction in cell proliferation and culture viability when maintained in media supplemented with the TET-On induction agent Doxycycline at concentrations commonly reported. Calculation of a mature miRNA and miRNA sponge mRNA copy number demonstrates that leaky basal transgene expression in the un-induced state, is sufficient for significant miRNA knockdown. This work highlights challenges of the TET-On inducible expression system for controlled manipulation of endogenous miRNAs with two examples; miR-378 and miR-455. The authors suggest a solution involving isolation of highly inducible clones and use a single cell analysis platform to demonstrate the heterogeneity of basal expression and inducibility. Finally, the authors describe numerous strategies to minimize leaky transgene expression and alterations to current miRNA sponge design.


Assuntos
Expressão Gênica/genética , MicroRNAs/genética , Tetraciclina/farmacologia , Animais , Células CHO , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Proliferação de Células/genética , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/genética , Cricetulus , Doxiciclina/farmacologia , Expressão Gênica/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Regulação da Expressão Gênica/genética , Vetores Genéticos/genética , Transgenes/genética
15.
Biosens Bioelectron ; 119: 86-93, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30103158

RESUMO

As a direct, label-free method, Surface Plasmon Resonance (SPR) detection significantly reduces the needs for liquid handling and reagent storage compared to common enzyme-linked immunosorbent assays (ELISAs), thus enabling comprehensive multiplexing of bioassays on microfluidic sample-to-answer systems. This paper describes a highly integrated centrifugal Lab-on-a-Disc (LoaD) platform for automating the full process chain extending between plasma extraction and subsequent aliquoting to five parallelized reaction channels for quantitative SPR detection by an inexpensive smartphone camera. The entire, multi-step / multi-reagent operation completes within less than 1 h. While the emphasis of this work is on the fluidic automation and parallelization by previously introduced, very robust event-triggered valving and buoyancy-driven centripetal pumping schemes, we successfully implement an immunoglobulin G (IgG) assay; by specific functionalization of the detection surfaces, the same disc layout can readily be customised for immunoassays panels from whole blood.


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoglobulina G/biossíntese , Técnicas Analíticas Microfluídicas , Ressonância de Plasmônio de Superfície , Técnicas Biossensoriais , Humanos
16.
ACS Omega ; 3(6): 6624-6634, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-30023955

RESUMO

Globally, the need for "on-site" algal-toxin monitoring has become increasingly urgent due to the amplified demand for fresh-water and for safe, "toxin-free" shellfish and fish stocks. Herein, we describe the first reported, Lab-On-A-Disc (LOAD) based-platform developed to detect microcystin levels in situ, with initial detectability of saxitoxin and domoic acid also reported. Using recombinant antibody technology, the LOAD platform combines immunofluorescence with centrifugally driven microfluidic liquid handling to achieve a next-generation disposable device capable of multianalyte sampling. A low-complexity "LED-photodiode" based optical sensing system was tailor-made for the platform, which allows the fluorescence signal of the toxin-specific reaction to be quantified. This system can rapidly and accurately detect the presence of microcystin-LR, domoic acid, and saxitoxin in 30 min, with a minimum of less than 5 min end-user interaction for maximum reproducibility. This method provides a robust "point of need" diagnostic alternative to the current laborious and costly methods used for qualitative toxin monitoring.

17.
Biosens Bioelectron ; 109: 214-223, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29567566

RESUMO

In this paper we present a wirelessly powered array of 128 centrifugo-pneumatic valves that can be thermally actuated on demand during spinning. The valves can either be triggered by a predefined protocol, wireless signal transmission via Bluetooth, or in response to a sensor monitoring a parameter like the temperature, or homogeneity of the dispersion. Upon activation of a resistive heater, a low-melting membrane (Parafilm™) is removed to vent an entrapped gas pocket, thus letting the incoming liquid wet an intermediate dissolvable film and thereby open the valve. The proposed system allows up to 12 heaters to be activated in parallel, with a response time below 3 s, potentially resulting in 128 actuated valves in under 30 s. We demonstrate, with three examples of common and standard procedures, how the proposed technology could become a powerful tool for implementing diagnostic assays on Lab-on-a-Disc. First, we implement wireless actuation of 64 valves during rotation in a freely programmable sequence, or upon user input in real time. Then, we show a closed-loop centrifugal flow control sequence for which the state of mixing of reagents, evaluated from stroboscopically recorded images, triggers the opening of the valves. In our last experiment, valving and closed-loop control are used to facilitate centrifugal processing of whole blood.


Assuntos
Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas/métodos , Tecnologia sem Fio , Centrifugação , Membranas Artificiais , Pressão , Rotação
18.
PLoS One ; 12(12): e0189923, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29267367

RESUMO

Measurement of the height of a packed column of cells or beads, which can be direclty related to the number of cells or beads present in a chamber, is an important step in a number of diagnostic assays. For example, haematocrit measurements may rapidly identify anemia or polycthemia. Recently, user-friendly and cost-efficient Lab-on-a-Chip devices have been developed towards isolating and counting cell sub-populations for diagnostic purposes. In this work, we present a low-cost optical module for estimating the filling level of packed magnetic beads within a Lab-on-a-Chip device. The module is compatible with a previously introduced, disposable microfluidic chip for rapid determination of CD4+ cell counts. The device is a simple optical microscope module is manufactured by 3D printing. An objective lens directly interrogates the height of packed beads which are efficiently isolated on the finger-actuated chip. Optionally, an inexpensive, battery-powered Light Emitting Diode may project a shadow of the microfluidic chip at approximately 50-fold magnification onto a nearby surface. The reader is calibrated with the filling levels of known concentrations of paramagnetic beads within the finger actuated chip. Results in direct and projector mode are compared to measurements from a conventional, inverted white-light microscope. All three read-out methods indicate a maximum variation of 6.5% between methods.


Assuntos
Contagem de Linfócito CD4 , Dispositivos Lab-On-A-Chip , Humanos
19.
Colloids Surf B Biointerfaces ; 158: 167-174, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28689099

RESUMO

Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO)5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL-1 on commercial grade polystyrene (PS) and 230pgmL-1 on plain PMMA surfaces to 130pgmL-1 on (PEI/GO)5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively.


Assuntos
Grafite/química , Polietilenoimina/química , Ensaio de Imunoadsorção Enzimática , Imunoensaio/métodos , Cinética , Polimetil Metacrilato/química
20.
Lab Chip ; 16(20): 4002-4011, 2016 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-27713985

RESUMO

Typical Lab-on-a-Disc (LoaD) platforms cannot make a continuous measurement while the disc is spinning; this drawback means that the disc usually must be stopped and aligned with a sensor. This can result in measurement errors in time-dependent assays along with inaccuracies due to liquid displacement and bubble formation in the absence of a stabilising centrifugal field. This paper presents a novel concept for a wirelessly electrified-Lab-on-a-Disc (eLoaD) platform that allows continuous measurement of experimental parameters while the disc is spinning. This platform incorporates all the components needed for measurement within the rotating frame of reference, and bidirectional transmission of data outside this reference frame, thus allowing for online measurement independent of the rotation of the disc. The eLoaD platform is conceived in a modular manner whereby an interchangeable and non-disposable 'Application Disc' can be fitted to the eLoaD platform and so the system can be adapted for a range of optical, electrochemical and other measurement types. As an application example, optical readout, using the Application Disc fitted with a silicon photomultiplier, is demonstrated using a tagged chemiluminescent antibody, which is commonly used, for instance, in ELISA assays. The precision of the eLoaD platform is >94%, while its accuracy, when compared to a commercial benchtop luminometer, is higher than 96%. The modular design of this platform will permit extension of this technology to many other LoaD applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...