JACC Cardiovasc Interv ; 14(4): 444-456, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33602441

RESUMO

OBJECTIVES: The aim of this study was to compare ticagrelor monotherapy with dual-antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) with drug-eluting stents. BACKGROUND: The role of abbreviated DAPT followed by an oral P2Y12 inhibitor after PCI remains uncertain. METHODS: Two randomized trials, including 14,628 patients undergoing PCI, comparing ticagrelor monotherapy with standard DAPT on centrally adjudicated endpoints were identified, and individual patient data were analyzed using 1-step fixed-effect models. The protocol was registered in PROSPERO (CRD42019143120). The primary outcomes were the composite of Bleeding Academic Research Consortium type 3 or 5 bleeding tested for superiority and, if met, the composite of all-cause death, myocardial infarction, or stroke at 1 year, tested for noninferiority against a margin of 1.25 on a hazard ratio (HR) scale. RESULTS: Bleeding Academic Research Consortium type 3 or 5 bleeding occurred in fewer patients with ticagrelor than DAPT (0.9% vs. 1.7%, respectively; HR: 0.56; 95% confidence interval [CI]: 0.41 to 0.75; p < 0.001). The composite of all-cause death, myocardial infarction, or stroke occurred in 231 patients (3.2%) with ticagrelor and in 254 patients (3.5%) with DAPT (HR: 0.92; 95% CI: 0.76 to 1.10; p < 0.001 for noninferiority). Ticagrelor was associated with lower risk for all-cause (HR: 0.71; 95% CI: 0.52 to 0.96; p = 0.027) and cardiovascular (HR: 0.68; 95% CI: 0.47 to 0.99; p = 0.044) mortality. Rates of myocardial infarction (2.01% vs. 2.05%; p = 0.88), stent thrombosis (0.29% vs. 0.38%; p = 0.32), and stroke (0.47% vs. 0.36%; p = 0.30) were similar. CONCLUSIONS: Ticagrelor monotherapy was associated with a lower risk for major bleeding compared with standard DAPT, without a concomitant increase in ischemic events.


Assuntos
Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Quimioterapia Combinada , Terapia Antiplaquetária Dupla , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Ticagrelor/efeitos adversos , Resultado do Tratamento
2.
Circ J ; 76(7): 1616-23, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22531596

RESUMO

BACKGROUND: Implantation of a metallic prosthesis creates local stiffness with a subsequent mismatch in the compliance of the vessel wall, disturbances in flow and heterogeneous distribution of wall shear stress. Polymeric bioresorbable ABSORB scaffolds have less stiffness than metallic platform stents. We sought to analyze the mismatch in vascular compliance after ABSORB implantation and its long-term resolution with bioresorption. METHODS AND RESULTS: A total of 83 patients from the ABSORB trials underwent palpography investigations (30 and 53 patients from ABSORB Cohorts A and B, respectively) to measure the compliance of the scaffolded and adjacent segments at various time points (from pre-implantation up to 24 months). The mean of the maximum strain values was calculated per segment by utilizing the Rotterdam Classification (ROC) score and expressed as ROC/mm. Scaffold implantation lead to a significant decrease in vascular compliance (median [IQR]) at the scaffolded segment (from 0.37 [0.24-0.45] to 0.14 [0.09-0.23], P<0.001) with mismatch in compliance in a paired analysis between the scaffolded and adjacent segments (proximal: 0.23 [0.12-0.34], scaffold: 0.12 [0.07-0.19], distal: 0.15 [0.05-0.26], P=0.042). This reported compliance mismatch disappears at short- and mid-term follow-up. CONCLUSIONS: The ABSORB scaffold decreases vascular compliance at the site of scaffold implantation. A compliance mismatch is evident immediately post-implantation and in contrast to metallic stents disappears in the mid-term, likely leading to a normalization of the rheological behavior of the scaffolded segment.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Circulação Coronária , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Hemodinâmica , Poliésteres/química , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fenômenos Biomecânicos , Fármacos Cardiovasculares/administração & dosagem , Complacência (Medida de Distensibilidade) , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção