Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 11(10)2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34685431

RESUMO

The establishment of steady-state continuous crop production during long-term deep space missions is critical for providing consistent nutritional and psychological benefits for the crew, potentially improving their health and performance. Three technology demonstrations were completed achieving simultaneous multi-species plant growth and the concurrent use of two Veggie units on the International Space Station (ISS). Microbiological characterization using molecular and culture-based methods was performed on leaves and roots from two harvests of three leafy greens, red romaine lettuce (Lactuca sativa cv. 'Outredgeous'); mizuna mustard, (Brassica rapa var japonica); and green leaf lettuce, (Lactuca sativa cv. Waldmann's) and associated rooting pillow components and Veggie chamber surfaces. Culture based enumeration and pathogen screening indicated the leafy greens were safe for consumption. Surface samples of the Veggie facility and plant pillows revealed low counts of bacteria and fungi and are commonly isolated on ISS. Community analysis was completed with 16S rRNA amplicon sequencing. Comparisons between pillow components, and plant tissue types from VEG-03D, E, and F revealed higher diversity in roots and rooting substrate than the leaves and wick. This work provides valuable information for food production-related research on the ISS and the impact of the plant microbiome on this unique closed environment.

2.
Front Plant Sci ; 11: 673, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32625217

RESUMO

The Advanced Plant Habitat (APH) is the largest research plant growth facility deployed on the International Space Station (ISS). APH is a fully enclosed, closed-loop plant life support system with an environmentally controlled growth chamber designed for conducting both fundamental and applied plant research during experiments extending as long as 135 days. APH was delivered to the ISS in parts aboard two commercial resupply missions: OA-7 in April 2017 and SpaceX-11 in June 2017, and was assembled and installed in the Japanese Experiment Module Kibo in November 2018. We report here on a 7-week-long hardware validation test that utilized a root module planted with both Arabidopsis (cv. Col 0) and wheat (cv. Apogee) plants. The validation test examined the APH's ability to control light intensity, spectral quality, humidity, CO2 concentration, photoperiod, temperature, and root zone moisture using commanding from ground facilities at the Kennedy Space Center (KSC). The test also demonstrated the execution of programmed experiment profiles that scheduled: (1) changes in environmental combinations (e.g., a daily photoperiod at constant relative humidity), (2) predetermined photographic events using the three APH cameras [overhead, sideview, and sideview near-infrared (NIR)], and (3) execution of experimental sequences during the life cycle of a crop (e.g., measure photosynthetic CO2 drawdown experiments). Arabidopsis and wheat were grown in microgravity to demonstrate crew procedures, planting protocols and watering schemes within APH. The ability of APH to contain plant debris was assessed during the harvest of mature Arabidopsis plants. Wheat provided a large evaporative load that tested root zone moisture control and the recovery of transpired water by condensation. The wheat canopy was also used to validate the ability of APH to measure gas exchange of plants from non-invasive gas exchange measurements (i.e., canopy photosynthesis and respiration). These features were evaluated by executing experiment profiles that utilized the CO2 drawdown technique to measure daily rates of canopy photosynthesis and dark-period CO2 increase for respiration. This hardware validation test confirmed that APH can measure fundamental plant responses to spaceflight conditions.

3.
Can J Surg ; 61(2): 105-113, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29582746

RESUMO

BACKGROUND: Liver resection may be associated with substantial blood loss, and cell saver use has been recommended for patients at high risk. We performed a study to compare the allogenic erythrocyte transfusion rate after liver resection between patients who had intraoperative cell salvage with a cell saver device versus patients who did not. Our hypothesis was that cell salvage with autologous transfusion would reduce the allogenic blood transfusion rate. METHODS: Cell salvage was used selectively in patients at high risk for intraoperative blood loss based on preoperatively known predictors: right and repeat hepatectomy. Patients who underwent elective right or repeat hepatectomy between Nov. 9, 2007, and Jan. 27, 2016 were considered for the study. Data were retrieved from a liver resection database and were analyzed retrospectively. Patients with cell saver use (since January 2013) constituted the experimental group, and those without cell salvage (2007-2012), the control group. To reduce selection bias, we matched propensity scores. The primary outcome was the allogenic blood transfusion rate within 90 days postoperatively. Secondary outcomes were the number of transfused erythrocyte units, and rates of overall and infectious complications. RESULTS: Ninety-six patients were included in the study, 41 in the cell saver group and 55 in the control group. Of the 96, 64 (67%) could be matched, 32 in either group. The 2 groups were balanced for demographic and clinical variables. The allogenic blood transfusion rate was 28% (95% confidence interval [CI] 12.5%-43.7%) in the cell saver group versus 72% (95% CI 56.3%-87.5%) in the control group (p < 0.001). The overall and infectious complication rates were not significantly different between the 2 groups. CONCLUSION: Intraoperative cell salvage with autologous transfusion in elective right or repeat hepatectomy reduced the allogenic blood transfusion rate.


CONTEXTE: La résection hépatique peut s'accompagner de pertes sanguines importantes et l'utilisation d'un système de récupération de sang autologue est recommandée chez les patients à risque élevé. Nous avons procédé à une étude pour comparer le taux de transfusion de sang allogénique après la résection hépatique selon que les patients avaient ou non été soumis à une intervention de récupération de sang autologue. Notre hypothèse est que la récupération de sang autologue peropératoire pourrait réduire le taux de transfusion de sang allogénique. MÉTHODES: La récupération de sang autologue a été utilisée sélectivement chez des patients exposés à un risque élevé à l'égard de pertes sanguines peropératoires, en fonction de facteurs prédictifs préopératoires connus : hépatectomie droite et reprise de l'hépatectomie. Les patients ayant subi une intervention chirurgicale non urgente pour hépatectomie droite ou reprise d'hépatectomie entre le 9 novembre 2007 et le 27 janvier 2016 ont été considérés comme admissibles à l'étude. Les données ont été récupérées à partir d'une base de données sur la résection hépatique et analysées de manière rétrospective. Les patients soumis à la récupération de sang autologue (à partir de janvier 2013) ont constitué le groupe expérimental, et les autres (2007-2012) ont constitué le groupe témoin. Pour réduire le risque de biais de sélection, nous avons apparié les scores de propension. Le paramètre principal était le taux de transfusion de sang allogénique dans les 90 jours suivant l'opération. Les paramètres secondaires étaient le nombre d'unités transfusées, le taux de complications infectieuses et le taux global de complications. RÉSULTATS: Quatre-vingt-seize patients ont pris part à l'étude, 41 dans le groupe soumis à la récupération de sang autologue et 55 dans le groupe témoin. Parmi les 96 patients de l'étude, 64 (67 %) ont pu être assortis, 32 dans chaque groupe. Les 2 groupes étaient équilibrés aux plans des variables démographiques et cliniques. Le taux d'allotransfusions a été de 28 % (intervalle de confiance [IC] de 95 % 12,5 %-43,7 %) dans le groupe soumis à la récupération de sang autologue, contre 72 % (IC de 95 % 56,3 %-87,5 %) dans le groupe témoin (p < 0,001). Le taux de complications infectieuses et le taux global de complications n'ont pas été significativement différents entre les 2 groupes. CONCLUSION: La récupération de sang autologue peropératoire dans les cas d'hépatectomie droite ou d'hépatectomie répétée a réduit le taux de transfusion de sang allogénique.


Assuntos
Perda Sanguínea Cirúrgica/estatística & dados numéricos , Transfusão de Sangue Autóloga/estatística & dados numéricos , Transfusão de Eritrócitos/estatística & dados numéricos , Hepatectomia/estatística & dados numéricos , Hepatopatias/cirurgia , Recuperação de Sangue Operatório/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Feminino , Hepatectomia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Sangue Operatório/instrumentação , Pontuação de Propensão , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...