Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Thorac Cardiovasc Surg ; 167(3): 861-868, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37541572

RESUMO

OBJECTIVES: To determine the impact of older donor age (70+ years) on long-term survival and freedom from chronic lung allograft dysfunction in lung transplant (LTx) recipients. METHODS: A retrospective single-center study was performed on all LTx recipients from 2002 to 2017 and a modern subgroup from 2013 to 2017. Recipients were stratified into 4 groups based on donor lung age (<18, 18-55, 56-69, ≥70 years). Donor and recipient characteristics were compared using χ2 tests for differences in proportions and analysis of variance for differences in means. Univariable and multivariable Cox regression was used to describe differences in long-term survival and freedom from chronic lung allograft dysfunction. RESULTS: Between 2002 and 2017, 1600 LTx were performed, 98 of which were performed from donors aged 70 years or older. Recipients of 70+ years donor lungs were significantly older with a mean age of 55.5 ± 12.9 years old (P = .001) and had more Status 3 (urgent) recipients (37.4%, P = .002). After multivariable regression, there were no significant differences in survival or freedom from chronic lung allograft dysfunction between the 4 strata of recipients. CONCLUSIONS: Lung transplantation using donors 70 years old or older can be considered when all other parameters suggest excellent donor lung function without compromising short- or long-term outcomes.


Assuntos
Transplante de Pulmão , Doadores de Tecidos , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Fatores Etários , Transplante de Pulmão/efeitos adversos , Pulmão
3.
ANZ J Surg ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37985608

RESUMO

Climate change is projected to become the leading cause of adverse health outcomes globally, and the healthcare system is a key contributor. Surgical theatres are three to six times more pollutant than other hospital areas, and produce anywhere from a fifth to a third of total hospital waste. Hospitals are increasingly expected to make operating theatres more sustainable, however guidelines to improve environmental sustainability are lacking, and previous research takes a narrow approach to operative sustainability. This paper presents a narrative review that, following a 'review of reviews' approach, aims to summarize the key recommendations to improve the environmental sustainability of surgical theatres. Key domains of discussion identified across the literature included minimisation of volatile anaesthetics, reduction of operating theatre power consumption, optimisation of surgical approach, re-use and re-processing of surgical instruments, waste management, and research, education and leadership. Implementation of individual items in these domains has seen significant reductions in the environmental impact of operative practice. This comprehensive summary of recommendations lays the framework from which providers can assess the sustainability of their practice and for the development of encompassing guidelines to build an environmentally sustainable surgical service.

5.
J Thorac Cardiovasc Surg ; 165(2): 526-531.e1, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35469599

RESUMO

OBJECTIVE: The decision to perform a single-lung transplant (SLT) when the contralateral donor lung is rejected is a challenging scenario. The introduction of ex vivo lung perfusion (EVLP) has improved donor lung assessment, and we hypothesize that it has improved SLT outcomes in this setting. METHODS: A retrospective single-center review of all SLTs performed between 2000 and 2017 was performed in which the years 2000 to 2008 were considered the "pre-EVLP era" and 2009 to 2017 the "EVLP era." Recipients of SLT lungs when the contralateral lung was declined were classified into 3 groups: (1) Pre-EVLP era, (2a) EVLP era but EVLP not used, and (2b) EVLP era and EVLP used. The outcomes of interest were survival, time-to-extubation, and intensive care unit and hospital stay. RESULTS: Among 1692 transplants between 2000 and 2017, 244 (14%) were SLT. SLT rate was similar between eras (pre-EVLP 16% vs EVLP 15%), but more SLTs were performed where the contralateral lung was declined in the EVLP era (pre-EVLP 32% vs EVLP 45%, P = .04). Lungs evaluated on EVLP had lower procurement partial pressure of oxygen and were more often from donation after cardiac death donors. Recipients were generally also sicker, with a greater proportion of rapidly deteriorating recipients. Despite this, outcomes were similar between eras with a trend towards lower 30-day mortality in the EVLP era. CONCLUSIONS: The availability of EVLP allowed for better evaluation of marginal single lungs when the contralateral was declined. This has led to increased use rates with preserved outcomes despite use of more extended criteria organs.


Assuntos
Transplante de Pulmão , Pulmão , Humanos , Estudos Retrospectivos , Perfusão/efeitos adversos , Pulmão/cirurgia , Transplante de Pulmão/efeitos adversos , Doadores de Tecidos
6.
J Heart Lung Transplant ; 40(11): 1422-1430, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34301464

RESUMO

BACKGROUND: Donor-recipient size-matching has been repeatedly reported to improve outcomes following lung transplantation (LTx). However, there is significant variability in practice and the optimal strategy for size-matching is yet to be defined. For recipients with ILD, size-matching decisions are complicated by concerns regarding the potential impact of pre-LTx pulmonary restriction. We evaluate whether a specific donor-to-recipient size-matching strategy, based on predicted total lung capacity, benefits this patient group. METHODS: This retrospective, single-centre, cohort study describes the post-LTx outcomes of adults who underwent LTx for ILD between 1983 and 2020. Only patients with restrictive physiology, based on pre-LTx pulmonary function testing were included. Post-LTx outcomes were compared based on donor-recipient predicted TLC (D-R pTLC) ratio. A D-R pTLC ratio of ≥0.8 or <1.2 for DLTx, and a D-R pTLC ratio of ≥0.8 or <1.0 for SLTx were classified as 'size-matched'. RESULTS: Five-hundred and fifty LTx recipients met inclusion criteria. Of these, 404 underwent DLTx and 146 underwent SLTx. Size-matching was achieved in 78% of DLTx and 47% of SLTx. Overall survival (p = 0.007) and CLAD-free survival (p < 0.001) was significantly improved following a size-matched DLTx, compared to those with D-R pTLC ratios <0.8 or ≥1.2. Size-matching based on a D-R pTLC ratio 0.8≥ <1.0 for SLTX did not significantly improve survival. CONCLUSIONS: D-R pTLC size-matching, based on a ratio of 0.8≥ <1.2 improved post-DLTx outcomes for patients with restrictive lung disease. This is simple to do, and if applied clinically, could improve overall outcomes in lung transplantation.


Assuntos
Doenças Pulmonares Intersticiais/cirurgia , Transplante de Pulmão/estatística & dados numéricos , Pulmão/fisiologia , Guias de Prática Clínica como Assunto , Doadores de Tecidos , Capacidade Pulmonar Total/fisiologia , Transplantados , Feminino , Seguimentos , Humanos , Doenças Pulmonares Intersticiais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Retrospectivos
7.
J Thorac Cardiovasc Surg ; 161(5): 1674-1685, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32723591

RESUMO

OBJECTIVES: Lobar lung transplantation (LLTx) from deceased donors is a potential solution for donor-recipient size mismatch for small sized recipients. We reviewed our institutional experience to compare outcomes after LLTx to standard lung transplantation (LTx). METHODS: We retrospectively reviewed transplants in our institution from January 2000 to December 2017. LLTx early- and long-term outcomes were compared with LTx. Additional analysis of outcomes was performed after dividing the cohort into 2 eras (era 1, 2000-2012; era 2, 2013-2017). RESULTS: Among the entire cohort (1665), 75 were LLTx (4.5%). Compared with LTx, LLTx were more frequently bridged to transplant with extracorporeal life support or mechanical ventilation and were transplanted in a rapidly deteriorating status (respectively, 20% vs 4.4%, P = .001; 22.7% vs 7.9, P < .001; and 41.3% vs 26.5%, P = .013). LLTx had longer intensive care unit and hospital lengths of stay (respectively, median 17 vs 4 days, and 45 vs 23, both P < .001), and greater 30-day mortality (13.3% vs 4.3%, P = .001) and 90-day mortality (17.3% vs 7.2%, P = .003). In era 2, despite a significantly greater 30-day mortality (10.8% vs 2.8%, P = .026), there was no significant difference in 90-day mortality between LLTx and LTx (13.5% vs 5.1%, P = .070). Overall survival at 1, 3, and 5 years was not significantly different between LLTx and LTx (73.2% vs 84.4%, 56.9% vs 68.4% and 50.4% vs 55.8, P = .088). CONCLUSIONS: Although LLTx is a high-risk procedure, both mid- and long-term survival are comparable with LTx in all cohorts in the modern era. LLTx therefore represents a valuable surgical option for small-sized recipients.


Assuntos
Transplante de Pulmão , Doadores de Tecidos , Adulto , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Pulmão/cirurgia , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Transplante de Pulmão/mortalidade , Transplante de Pulmão/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Ann Thorac Surg ; 110(3): e231-e232, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31589861

RESUMO

Pulmonary endarterectomy is the treatment of choice for chronic thromboembolic pulmonary hypertension. This case report outlines the importance of venoarterial extracorporeal membrane oxygenation and plasmapheresis as two important options in the management of heparin-induced thrombocytopenia-positive patients requiring urgent pulmonary endarterectomy.


Assuntos
Endarterectomia , Oxigenação por Membrana Extracorpórea , Heparina/efeitos adversos , Plasmaferese , Embolia Pulmonar/cirurgia , Trombocitopenia/induzido quimicamente , Idoso , Anticoagulantes/efeitos adversos , Feminino , Humanos , Trombocitopenia/complicações
10.
Perfusion ; 33(5): 363-366, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29272987

RESUMO

BACKGROUND: The isolated heart apparatus is over 100 years old, but remains a useful research tool today. While designs of many large animal systems have been described in the literature, trouble-shooting and refining such a model to yield a stable, workable system has not been previously described. This paper outlines the issues, in tabular form, that our group encountered in developing our own porcine isolated heart rig with the aim of assisting other workers in the field planning similar work. The paper also highlights some of the modern applications of the isolated heart apparatus. Methods Landrace pigs (50-80 kg) were used in a pilot project to develop the model. The model was then used in a study examining the effects of various cardioplegic solutions on function after reanimation of porcine hearts. During the two projects, non-protocol issues were documented as well as their solutions. These were aggregated in this paper. RESULTS: Issues faced by the group without explicit literature solutions included pig size selection, animal acclimatisation, porcine transoesophageal echocardiography, cannulation and phlebotomy for cross-clamping, cardioplegia delivery, heart suspension and rig tuning. CONCLUSION: Prior recognition of issues and possible solutions faced by workers establishing a porcine isolated heart system will speed progress towards a useable system for research. The isolated heart apparatus remains applicable in transplant, ischaemia reperfusion, heart failure and organ preservation research.


Assuntos
Coração/fisiologia , Preparação de Coração Isolado/instrumentação , Perfusão/instrumentação , Suínos/fisiologia , Animais , Soluções Cardioplégicas/administração & dosagem , Desenho de Equipamento , Parada Cardíaca Induzida/instrumentação , Parada Cardíaca Induzida/métodos , Preparação de Coração Isolado/métodos , Preservação de Órgãos/instrumentação , Preservação de Órgãos/métodos , Perfusão/métodos , Projetos Piloto
11.
Ann Thorac Surg ; 102(2): e131-3, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27449448

RESUMO

There is minimal reported experience with long-range retrieval of pediatric patients receiving extracorporeal membrane oxygenation (ECMO) support. We report the case of a 10-month old boy with necrotizing staphylococcal pneumonia complicated by a bronchopleural fistula, who was successfully retrieved and transported while receiving ECMO to our unit in Sydney, Australia, from a referring hospital 2,000 kilometers away in the Pacific Islands. He was successfully weaned from ECMO to receive single-lung ventilation after 13 days, and he underwent surgical repair of his bronchopleural fistula through a thoracotomy 3 days after decannulation. He has made a full recovery.


Assuntos
Fístula Brônquica/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Internacionalidade , Insuficiência Respiratória/terapia , Transporte de Pacientes/métodos , Fístula Brônquica/complicações , Seguimentos , Humanos , Lactente , Masculino , New South Wales , Ilhas do Pacífico , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/etiologia , Índice de Gravidade de Doença , Toracotomia/métodos , Resultado do Tratamento
12.
Artigo em Inglês | MEDLINE | ID: mdl-27143717

RESUMO

We describe a case of fatal acute appendicitis in a neonate associated with congenital cardiac disease requiring staged surgery. Neonatal appendicitis is extremely rare and usually associated with prematurity and congenital abdominal conditions. This report serves to highlight the risk of this disease due to vascular insufficiency and ischemia in neonates with congenital cardiac disease and highlight the importance of considering this diagnosis in such a neonate with unexplained sepsis even in the absence of clear abdominal signs.

13.
Ann Thorac Surg ; 102(1): 192-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27112655

RESUMO

BACKGROUND: Anomalous aortic origin of the right coronary artery (AAORCA) has been reported to cause myocardial ischemia, leading to angina, dyspnea, and decreased exercise tolerance. Reimplantation is a repair technique devised to exclude the abnormal intramural portion of the anomalous artery and avoid the known late attrition of saphenous vein grafts. Our study aims to evaluate the medium-term clinical outcomes with this technique. METHODS: A retrospective review was made of patients who underwent repair of AAORCA by reimplantation between 2002 and 2014 in two institutions in Western Australia. Follow-up computed tomography coronary angiography was used to assess the status of the reimplanted right coronary artery (RCA). Data on survival, freedom from symptoms, cardiac events, and cardiac interventions were also analyzed. RESULTS: Of the 16 patients (aged 17 to 70 years old), 14 (88%) were symptomatic before surgery, with angina (50%) and exertional dyspnea (56%) being the most common symptoms. Surgical reimplantation was successful in 15 patients (94%) without operative mortality. One patient required saphenous vein bypass grafting of the RCA intraoperatively after presumed failed repair and difficulty weaning from cardiopulmonary bypass. All patients who had successful reimplantation of AAORCA were symptom-free after surgery, and none had subsequent cardiac events attributable to the RCA or required further interventions. Ten patients (67%) had computed tomography coronary angiography after surgery; none had stenosis, kinking, or compression of the RCA by the pulmonary artery. Two further patients (including the patient who underwent saphenous vein grafting for presumed failed reimplantation) underwent conventional angiography, which demonstrated patent reimplantations. CONCLUSIONS: To the best of our knowledge, this is the largest reported series of anomalous RCA managed by surgical reimplantation. Our results suggest that this technique is safe and has excellent medium to long-term results regarding symptom-free survival.


Assuntos
Aorta Torácica/anormalidades , Anomalias dos Vasos Coronários/cirurgia , Vasos Coronários/transplante , Gerenciamento Clínico , Reimplante , Procedimentos Cirúrgicos Vasculares/métodos , Adolescente , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
14.
Eur J Cardiothorac Surg ; 49(5): e105-11, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26905179

RESUMO

OBJECTIVES: The Freestyle valve may be used for pulmonary valve replacement (PVR). Whether its stentless design and anticalcification treatment improve durability relative to alternative bioprostheses, however, is unknown and long-term data are lacking. METHODS: We performed a retrospective review of all Freestyle PVRs performed by a single surgeon in two institutions. All patients were contacted for follow-up to establish survival, New York Heart Association class and reintervention. Up to date, echocardiography was obtained to assess valve function. Perioperative factors associated with structural valve dysfunction (SVD) were assessed using Cox regression. RESULTS: Between 2000 and 2014, PVR with a Freestyle valve was performed in 114 patients with congenital heart disease. There were 70 males and 44 females. The median age was 21 years (interquartile range 11-35 years). The median clinical and echocardiographic follow-up was 62 months (interquartile range 35-115 months, n = 110) and 58 months (interquartile range 30-93 months, n = 107), respectively. Follow-up was complete for 107 of 114 patients (94%). The survival rate was 95% at 5 years and 91% at 10 years. The rate of freedom from SVD at 5 years was 82%, and at 10 years was 61%. The reintervention-free survival rate was 85% at 5 years, and 71% at 10 years. CONCLUSION: The Freestyle valve in the pulmonary position in a congenital population is associated with low medium-term incidences of SVD and reintervention. It performs equally well to the homograft when a conduit is required and can be considered a valid alternative to stented bioprostheses when PVR alone is required.


Assuntos
Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Adolescente , Adulto , Criança , Feminino , Cardiopatias Congênitas/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
15.
Interact Cardiovasc Thorac Surg ; 22(5): 594-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26912576

RESUMO

OBJECTIVES: Deep sternal wound infection is a devastating complication of cardiac surgery. In the current era of increasing patient comorbidity, newer techniques must be evaluated in attempts to reduce the rates of deep sternal wound infection. METHODS: A randomized controlled trial comparing sternal closure with traditional sternal wires in figure-8 formation with the Pioneer cabling system® from Medigroup after adult cardiac surgery was performed. RESULTS: A total of 273 patients were enrolled with 137 and 135 patients randomized to sternal wires and cables group, respectively. Baseline characteristics between the two groups were well balanced. Deep sternal wound infection occurred in 0.7% of patients in the wires group and 3.7% of patients in the cables group (absolute risk difference = -3.0%, 95% confidence interval: -7.7 to 0.9%; P = 0.12). Patients in the cables group were extubated slightly earlier than those in the sternal wires group postoperatively (9.7 vs 12.8 h; P = 0.03). There was, however, no significant difference in hospital and follow-up pain scores or analgesia requirements. CONCLUSIONS: The Pioneer sternal cabling system appears to facilitate early extubation after adult cardiac surgery, but it does not reduce the rate of deep sternal infectionAustralian New Zealand Clinical Trials Registry: ANZCTR-ACTRN12615000973516.


Assuntos
Fios Ortopédicos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Esterno/cirurgia , Infecção da Ferida Cirúrgica/prevenção & controle , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Método Simples-Cego , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento
16.
Heart Lung Circ ; 24(12): e210-3, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26304799

RESUMO

A 36-year-old woman presented to hospital after a penetrating chest injury. She was haemodynamically stable. Echocardiography revealed left ventricular thrombus, with minimal pericardial effusion and no associated cardiac injuries. Intravenous anticoagulation was commenced for her intracardiac thrombus and her pericardial effusion was monitored with serial echocardiography. She remained well, was converted to warfarin and discharged home day 12 post admission, with cautious follow-up given her risk of late effusion and tamponade. Follow-up imaging revealed resolution of her intracardiac thrombus. She remains well to date.


Assuntos
Traumatismos Cardíacos/tratamento farmacológico , Heparina/administração & dosagem , Derrame Pericárdico/tratamento farmacológico , Trombose/tratamento farmacológico , Ferimentos Penetrantes/tratamento farmacológico , Adulto , Feminino , Humanos
17.
Ann Thorac Surg ; 100(1): 354-61, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26002442

RESUMO

Two alternative approaches for transcatheter aortic valve implantation (TAVI) exist for patients unsuitable for the transfemoral approach; the transapical and the transaortic approaches. It is unclear as to which approach has superior short-term outcomes. A systematic review and meta-analysis was performed to answer this question. Mortality was equivalent in the 2 groups. There was a trend toward a lower rate of stroke in the transaortic group (0.9% vs 2.1%) but this was not statistically significant. Conversion to surgical aortic valve replacement, paravalvular leak, pacemaker requirement, and major bleeding occurred at equivalent rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Substituição da Valva Aórtica Transcateter
18.
Ann Thorac Surg ; 99(5): 1841-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25795296

RESUMO

It remains unclear as to whether mechanical valves have a role in pulmonary valve replacement. A systematic review and meta-analysis was performed to answer this question. Nineteen observational studies, including 299 pediatric and adult patients with a mean follow-up of 73 months, were analyzed. Nonstructural valve deterioration and valve thrombosis occurred in 1.5% and 2.2% of patients, respectively. Surgical reintervention was required in 0.9% of cases and thrombolysis was required in 0.5%. Mechanical valves in the pulmonary position are associated with a low incidence of valve deterioration and thrombosis, as well as freedom from reoperation and thrombolysis.


Assuntos
Próteses Valvulares Cardíacas , Ventrículos do Coração/cirurgia , Valva Pulmonar/cirurgia , Procedimentos Cirúrgicos Cardíacos , Humanos , Desenho de Prótese
20.
Heart Lung Vessel ; 7(4): 304-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26811836

RESUMO

INTRODUCTION: Reconstruction of the right ventricular outflow tract is the most commonly performed valve repair/replacement procedure in congenital cardiac surgery. There is an ongoing shortage of homografts, and existing bioprosthetic options suffer from substantial rates of structural valve deterioration over time. The Medtronic Freestyle valve is used extensively in the aortic position, but little data is available on its performance in the pulmonary position. METHODS: A systematic review and meta-analysis of primary studies reporting echocardiographic and clinical outcomes, including reintervention and functional status, associated with the Freestyle valve in the pulmonary position for both Ross and congenital surgery. RESULTS: 13 observational studies including 334 patients with a mean follow-up of 34 months (range 10-98 months) fulfilled the eligibility criteria and were included in the review. Structural valve deterioration occurred in 4.8% (95% confidence interval 0.8-10.6%) of patients. Reintervention was required in 1.1% (95% confidence interval 0.0-3.3%). Freedom from symptoms of heart failure occurred in 97.7% (94.6-99.7%). The results did not change substantially when analysed according to Ross or congenital surgery. CONCLUSIONS: The Freestyle valve performs well at short-term follow-up and provides a viable alternative when homografts are unavailable. Further long-term studies are required to better assess its role in right ventricular outflow tract reconstruction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...