Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Acta Biomater ; 180: 115-127, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38642786

RESUMO

Bone has the capacity to regenerate itself for relatively small defects; however, this regenerative capacity is diminished in critical-size bone defects. The development of synthetic materials has risen as a distinct strategy to address this challenge. Effective synthetic materials to have emerged in recent years are bioceramic implants, which are biocompatible and highly bioactive. Yet nothing suitable for the repair of large bone defects has made the transition from laboratory to clinic. The clinical success of bioceramics has been shown to depend not only on the scaffold's intrinsic material properties but also on its internal porous geometry. This study aimed to systematically explore the implications of varying channel size, shape, and curvature in tissue scaffolds on in vivo bone regeneration outcomes. 3D printed bioceramic scaffolds with varying channel sizes (0.3 mm to 1.5 mm), shapes (circular vs rectangular), and curvatures (concave vs convex) were implanted in rabbit femoral defects for 8 weeks, followed by histological evaluation. We demonstrated that circular channel sizes of around 0.9 mm diameter significantly enhanced bone formation, compared to channel with diameters of 0.3 mm and 1.5 mm. Interestingly, varying channel shapes (rectangular vs circular) had no significant effect on the volume of newly formed bone. Furthermore, the present study systematically demonstrated the beneficial effect of concave surfaces on bone tissue growth in vivo, reinforcing previous in silico and in vitro findings. This study demonstrates that optimizing architectural configurations within ceramic scaffolds is crucial in enhancing bone regeneration outcomes. STATEMENT OF SIGNIFICANCE: Despite the explosion of work on developing synthetic scaffolds to repair bone defects, the amount of new bone formed by scaffolds in vivo remains suboptimal. Recent studies have illuminated the pivotal role of scaffolds' internal architecture in osteogenesis. However, these investigations have mostly remained confined to in silico and in vitro experiments. Among the in vivo studies conducted, there has been a lack of systematic analysis of individual architectural features. Herein, we utilized bioceramic 3D printing to conduct a systematic exploration of the effects of channel size, shape, and curvature on bone formation in vivo. Our results demonstrate the significant influence of channel size and curvature on in vivo outcomes. These findings provide invaluable insights into the design of more effective bone scaffolds.


Assuntos
Cerâmica , Osteogênese , Alicerces Teciduais , Impressão Tridimensional , Cerâmica/química , Alicerces Teciduais/química , Alicerces Teciduais/normas , Osteogênese/fisiologia , Animais , Coelhos , Masculino , Propriedades de Superfície
2.
Acta Biomater ; 162: 199-210, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36893955

RESUMO

Here we report the first atom probe study to reveal the atomic-scale composition of in vivo bone formed in a bioceramic scaffold (strontium-hardystonite-gahnite) after 12-month implantation in a large bone defect in sheep tibia. The composition of the newly formed bone tissue differs to that of mature cortical bone tissue, and elements from the degrading bioceramic implant, particularly aluminium (Al), are present in both the newly formed bone and in the original mature cortical bone tissue at the perimeter of the bioceramic implant. Atom probe tomography confirmed that the trace elements are released from the bioceramic and are actively transported into the newly formed bone. NanoSIMS mapping, as a complementary technique, confirmed the distribution of the released ions from the bioceramic into the newly formed bone tissue within the scaffold. This study demonstrated the combined benefits of atom probe and nanoSIMS in assessing nanoscopic chemical composition changes at precise locations within the tissue/biomaterial interface. Such information can assist in understanding the interaction of scaffolds with surrounding tissue, hence permitting further iterative improvements to the design and performance of biomedical implants, and ultimately reducing the risk of complications or failure while increasing the rate of tissue formation. STATEMENT OF SIGNIFICANCE: The repair of critical-sized load-bearing bone defects is a challenge, and precisely engineered bioceramic scaffold implants is an emerging potential treatment strategy. However, we still do not understand the effect of the bioceramic scaffold implants on the composition of newly formed bone in vivo and surrounding existing mature bone. This article reports an innovative route to solve this problem, the combined power of atom probe tomography and nanoSIMS is used to spatially define elemental distributions across bioceramic implant sites. We determine the nanoscopic chemical composition changes at the Sr-HT Gahnite bioceramic/bone tissue interface, and importantly, provide the first report of in vivo bone tissue chemical composition formed in a bioceramic scaffold.


Assuntos
Materiais Biocompatíveis , Alicerces Teciduais , Animais , Ovinos , Alicerces Teciduais/química , Materiais Biocompatíveis/química , Osteogênese , Osso e Ossos/diagnóstico por imagem , Tomografia
3.
Eur J Pharmacol ; 939: 175470, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36543287

RESUMO

Mitochondria in tumor cells are functionally different from those in normal cells and could be targeted to develop new anticancer agents. We showed recently that the aryl-ureido fatty acid CTU is the prototype of a new class of mitochondrion-targeted agents that kill cancer cells by increasing the production of reactive oxygen species (ROS), activating endoplasmic reticulum (ER)-stress and promoting apoptosis. However, prolonged treatment with high doses of CTU were required for in vivo anti-tumor activity. Thus, new strategies are now required to produce agents that have enhanced anticancer activity over CTU. In the present study we prepared a novel aryl-urea termed 3-thiaCTU, that contained an in-chain sulfur heteroatom, for evaluation in tumor cell lines and in mice carrying tumor xenografts. The principal finding to emerge was that 3-thiaCTU was several-fold more active than CTU in the activation of aryl-urea mechanisms that promoted cancer cell killing. Thus, in in vitro studies 3-thiaCTU disrupted the mitochondrial membrane potential, increased ROS production, activated ER-stress and promoted tumor cell apoptosis more effectively than CTU. 3-ThiaCTU was also significantly more active than CTUin vivo in mice that carried MDA-MB-231 cell xenografts. Compared to CTU, 3-thiaCTU prevented tumor growth more effectively and at much lower doses. These findings indicate that, in comparison to CTU, 3-thiaCTU is an aryl-urea with markedly enhanced activity that could now be suitable for development as a novel anticancer agent.


Assuntos
Antineoplásicos , Ácidos Graxos , Humanos , Animais , Camundongos , Ácidos Graxos/farmacologia , Ácidos Graxos/metabolismo , Ureia/farmacologia , Ureia/uso terapêutico , Espécies Reativas de Oxigênio/metabolismo , Mitocôndrias , Apoptose , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Antineoplásicos/metabolismo , Linhagem Celular Tumoral , Estresse do Retículo Endoplasmático , Potencial da Membrana Mitocondrial
4.
J Gerontol A Biol Sci Med Sci ; 78(2): 186-194, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36037105

RESUMO

Combating the accumulated senescent cells and the healing of osteoporotic bone fractures in the older remains a significant challenge. Nicotinamide mononucleotide (NMN), a precursor of NAD+, is an excellent candidate for mitigating aging-related disorders. However, it is unknown if NMN can alleviate senescent cell induction and enhance osteoporotic bone fracture healing. Here we show that NMN treatment partially reverses the effects of tumor necrosis factor-alpha (TNF-α) on human primary osteoblasts (HOBs): senescent cell induction, diminished osteogenic differentiation ability, and intracellular NAD+ and NADH levels. Mechanistically, NMN restores the mitochondrial dysfunction in HOBs induced by TNF-α evidenced by increased mitochondrial membrane potential and reduced reactive oxidative species and mitochondrial mass. NMN also increases mitophagy activity by down-regulating P62 expression and up-regulating light chain 3B-II protein expression. In addition, the cell senescence protective effects of NMN on HOBs are mitigated by a mitophagy inhibitor (Bafilomycin A1). In vivo, NMN supplementation attenuates senescent cell induction in growth plates, partially prevents osteoporosis in an ovariectomized mouse model, and accelerates bone healing in osteoporotic mice. We conclude that NMN can be a novel and promising therapeutic candidate to enhance bone fracture healing capacity in the older.


Assuntos
Mononucleotídeo de Nicotinamida , Osteoporose , Camundongos , Humanos , Animais , Mononucleotídeo de Nicotinamida/farmacologia , NAD/metabolismo , Osteogênese , Fator de Necrose Tumoral alfa , Osteoblastos/metabolismo
5.
Acta Biomater ; 156: 214-221, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-35063706

RESUMO

There is an unmet clinical need for a spinal fusion implant material that recapitulates the biological and mechanical performance of natural bone. We have developed a bioceramic, Sr-HT-Gahnite, which has been identified as a potential fusion device material. This material has the capacity to transform the future of the global interbody devices market, with follow on social, economic, and environmental benefits, rooted in its remarkable combination of mechanical properties and bioactivity. In this study, and in line with FDA requirements, the in vivo preclinical systemic biological safety of a Sr-HT-Gahnite interbody fusion device is assessed over 26 weeks in sheep under good laboratory practice (GLP). Following the in-life phase, animals are assessed for systemic biological effects via blood haematology and clinical biochemistry, strontium dosage analysis in the blood and wool, and histopathology examination of the distant organs including adrenals, brain, heart, kidneys, liver, lungs and bronchi, skeletal muscle, spinal nerves close to the implanted sites, ovaries, and draining lymph nodes. Our results show that no major changes in blood haematology or biochemistry parameters are observed, no systemic distribution of strontium to the blood and wool, and no macroscopic or histopathological abnormalities in the distant organs when Sr-HT-Gahnite was implanted, compared to baseline and control values. Together, these results indicate the systemic safety of the Sr-HT-Gahnite interbody fusion device. The results of this study extend to the systemic safety of other Sr-HT-Gahnite implanted medical devices in contact with bone or tissue, of similar size and manufactured using the described processes. STATEMENT OF SIGNIFICANCE: This paper is considered original and innovative as it is the first that thoroughly reports the systemic biological safety of previously undescribed bioceramic material, Sr-HT-Gahnite. The study has been performed under good laboratory practice, in line with FDA requirements for assessment of a new interbody fusion device, making the results broadly applicable to the translation of sheep models to the human cervical spine; and also the translation of Sr-HT-Gahnite as a biomaterial for use in additional applications. We expect this study to be of broad interest to the readership of Acta Biomaterilia. Its findings are directly applicable to researchers and clinicians working in bone repair and the development of synthetic biomaterials.


Assuntos
Materiais Biocompatíveis , Fusão Vertebral , Humanos , Animais , Ovinos , Materiais Biocompatíveis/química , Próteses e Implantes , Osso e Ossos , Estrôncio/farmacologia , Estrôncio/química , Impressão Tridimensional , Fusão Vertebral/métodos
6.
Polymers (Basel) ; 14(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35683861

RESUMO

The selection of biomaterials as biomedical implants is a significant challenge. Ultra-high molecular weight polyethylene (UHMWPE) and composites of such kind have been extensively used in medical implants, notably in the bearings of the hip, knee, and other joint prostheses, owing to its biocompatibility and high wear resistance. For the Anterior Cruciate Ligament (ACL) graft, synthetic UHMWPE is an ideal candidate due to its biocompatibility and extremely high tensile strength. However, significant problems are observed in UHMWPE based implants, such as wear debris and oxidative degradation. To resolve the issue of wear and to enhance the life of UHMWPE as an implant, in recent years, this field has witnessed numerous innovative methodologies such as biofunctionalization or high temperature melting of UHMWPE to enhance its toughness and strength. The surface functionalization/modification/treatment of UHMWPE is very challenging as it requires optimizing many variables, such as surface tension and wettability, active functional groups on the surface, irradiation, and protein immobilization to successfully improve the mechanical properties of UHMWPE and reduce or eliminate the wear or osteolysis of the UHMWPE implant. Despite these difficulties, several surface roughening, functionalization, and irradiation processing technologies have been developed and applied in the recent past. The basic research and direct industrial applications of such material improvement technology are very significant, as evidenced by the significant number of published papers and patents. However, the available literature on research methodology and techniques related to material property enhancement and protection from wear of UHMWPE is disseminated, and there is a lack of a comprehensive source for the research community to access information on the subject matter. Here we provide an overview of recent developments and core challenges in the surface modification/functionalization/irradiation of UHMWPE and apply these findings to the case study of UHMWPE for ACL repair.

7.
Biochem Pharmacol ; 192: 114726, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34389322

RESUMO

Migration and invasion promote tumor cell metastasis, which is the leading cause of cancer death. At present there are no effective treatments. Epidemiological studies have suggested that ω-3 polyunsaturated fatty acids (PUFA) may decrease cancer aggressiveness. In recent studies epoxide metabolites of ω-3 PUFA exhibited anti-cancer activity, although increased in vivo stability is required to develop useful drugs. Here we synthesized novel stabilized ureido-fatty acid ω-3 epoxide isosteres and found that one analogue - p-tolyl-ureidopalmitic acid (PTU) - inhibited migration and invasion by MDA-MB-231 breast cancer cells in vitro and in vivo in xenografted nu/nu mice. From proteomics analysis of PTU-treated cells major regulated pathways were linked to the actin cytoskeleton and actin-based motility. The principal finding was that PTU impaired the formation of actin protrusions by decreasing the secretion of Wnt5a, which dysregulated the Wnt/planar cell polarity (PCP) pathway and actin cytoskeletal dynamics. Exogenous Wnt5a restored invasion and Wnt/PCP signalling in PTU-treated cells. PTU is the prototype of a novel class of agents that selectively dysregulate the Wnt/PCP pathway by inhibiting Wnt5a secretion and actin dynamics to impair MDA-MB-231 cell migration and invasion.


Assuntos
Citoesqueleto/metabolismo , Ácidos Graxos Ômega-3/farmacologia , Transdução de Sinais/fisiologia , Proteína Wnt-5a/antagonistas & inibidores , Proteína Wnt-5a/metabolismo , Animais , Linhagem Celular Tumoral , Citoesqueleto/efeitos dos fármacos , Ácidos Graxos Ômega-3/química , Feminino , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Invasividade Neoplásica/patologia , Transdução de Sinais/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto/métodos
8.
Acta Biomater ; 132: 217-226, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-33711527

RESUMO

An ongoing challenge in the field of orthopedics is to produce a clinically relevant synthetic ceramic scaffold for the treatment of 'critical-sized' bone defects, which cannot heal without intervention. We had developed a bioactive ceramic (baghdadite, Ca3ZrSi2O9) and demonstrated its outstanding bioactivity using traditional manufacturing techniques. Here, we report on the development of a versatile stereolithography printing technology that enabled fabrication of anatomically-shaped and -sized Baghdadite scaffolds. We assessed the in vivo bioactivity of these scaffolds in co-delivering of bone morphogenetic protein-2 (BMP2) and zoledronic acid (ZA) through bioresorbable coatings to induce bone formation and increase retention in a rat model of heterotopic ossification. Micro-computed tomography, histology, mechanical tests pre- and post-implantation, and mechanical modelling were used to assess bone ingrowth and its effects on the mechanics of the scaffolds. Bone ingrowth and the consequent mechanical properties of the scaffolds improved with increasing BMP2 dose. Co-delivery of ZA with BMP2 further improved this outcome. The significant bone formation within the scaffolds functionalized with 10 µg BMP2 and 2 µg ZA made them 2.3 × stiffer and 2.7 × stronger post-implantation and turned these inherently brittle scaffolds into a tough and deformable material. The effects of bone ingrowth on the mechanical properties of scaffolds were captured in a mechanical model that can be used in future clinical studies for non-destructive evaluation of scaffold's stiffness and strength as new bone forms. These results support the practical utilization of our versatile stereolithographic printing methods and BMP2/ZA functionalization to create fit-for-purpose personalized implants for clinical trials. STATEMENT OF SIGNIFICANCE: In this study, we addressed a long-standing challenge of developing a ceramic printing technology that enables fabrication of customizable anatomically-shaped and -sized bioceramic scaffolds with precise internal architectures using an inexpensive desktop printer. We also addressed another challenge related to delivery of pharmaceuticals. BMP2, currently available as a bone-inducing bioactive protein, is clinically administered in a collagen scaffold that has limited moldability and poor mechanical properties. The comparably stiffer and stronger 3D printed personalized Baghdadite scaffolds developed here can be readily functionalized with bioresorbable coatings containing BMP2 ± ZA. These innovations considerably improve on the prior art and are scalable for use in human surgery.


Assuntos
Regeneração Óssea , Alicerces Teciduais , Animais , Cerâmica/farmacologia , Osteogênese , Impressão Tridimensional , Ratos , Silicatos , Estereolitografia , Microtomografia por Raio-X
9.
ACS Biomater Sci Eng ; 6(12): 6874-6885, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33320606

RESUMO

Bone fractures and critical-sized bone defects present significant health threats for the elderly who have limited capacity for regeneration due to the presence of functionally compromised senescent cells. A wide range of synthetic materials has been developed to promote the regeneration of critical-sized bone defects, but it is largely unknown if a synthetic biomaterial (scaffold) can modulate cellular senescence and improve bone regeneration in aged scenarios. The current study investigates the interaction of Baghdadite (Ca3ZrSi2O9) ceramic scaffolds with senescent human primary osteoblast-like cells (HOBs) and its bone regeneration capacity in aged rats. A senescent HOB model was established by repeatedly passaging HOBs till passage 7 (P7). Compared to the clinically used hydroxyapatite/tricalcium phosphate (HA/TCP), Baghdadite prevented senescence induction in P7 HOBs and markedly negated the paracrine effect of P7 HOB secretomes that mediated the up-regulations of cellular senescence-associated gene expression levels in P2 HOBs. We further demonstrated that conditioned media extracted from Baghdadite corrected the dysfunctional mitochondria in P7 HOBs. In vivo, the bone regeneration capacity was enhanced when 3D printed Baghdadite scaffolds were implanted in a calvaria critical-sized bone defect model in both young and aged rats compared to HA/TCP scaffolds, but a better effect was observed in aged rats than in young rats. This study suggests that Baghdadite ceramic represents a novel and promising biomaterial approach to promote bone regeneration capacity in the elderly by providing an anti-senescent microenvironment.


Assuntos
Regeneração Óssea , Alicerces Teciduais , Idoso , Animais , Cerâmica , Humanos , Osteoblastos , Ratos , Silicatos
10.
Stem Cells Transl Med ; 9(3): 403-415, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31904196

RESUMO

The induced pluripotent stem cell (iPSC) is a promising cell source for tissue regeneration. However, the therapeutic value of iPSC technology is limited due to the complexity of induction protocols and potential risks of teratoma formation. A trans-differentiation approach employing natural factors may allow better control over reprogramming and improved safety. We report here a novel approach to drive trans-differentiation of human fibroblasts into functional osteoblasts using insulin-like growth factor binding protein 7 (IGFBP7). We initially determined that media conditioned by human osteoblasts can induce reprogramming of human fibroblasts to functional osteoblasts. Proteomic analysis identified IGFBP7 as being significantly elevated in media conditioned with osteoblasts compared with those with fibroblasts. Recombinant IGFBP7 induced a phenotypic switch from fibroblasts to osteoblasts. The switch was associated with senescence and dependent on autocrine IL-6 signaling. Our study supports a novel strategy for regenerating bone by using IGFBP7 to trans-differentiate fibroblasts to osteoblasts.


Assuntos
Fibroblastos/metabolismo , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/genética , Osteoblastos/metabolismo , Animais , Humanos , Camundongos , Camundongos Nus , Ensaios Antitumorais Modelo de Xenoenxerto
12.
Adv Healthc Mater ; 8(8): e1801298, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30773833

RESUMO

Achieving adequate healing in large or load-bearing bone defects is highly challenging even with surgical intervention. The clinical standard of repairing bone defects using autografts or allografts has many drawbacks. A bioactive ceramic scaffold, strontium-hardystonite-gahnite or "Sr-HT-Gahnite" (a multi-component, calcium silicate-based ceramic) is developed, which when 3D-printed combines high strength with outstanding bone regeneration ability. In this study, the performance of purely synthetic, 3D-printed Sr-HT-Gahnite scaffolds is assessed in repairing large and load-bearing bone defects. The scaffolds are implanted into critical-sized segmental defects in sheep tibia for 3 and 12 months, with bone autografts used for comparison. The scaffolds induce substantial bone formation and defect bridging after 12 months, as indicated by X-ray, micro-computed tomography, and histological and biomechanical analyses. Detailed analysis of the bone-scaffold interface using focused ion beam scanning electron microscopy and multiphoton microscopy shows scaffold degradation and maturation of the newly formed bone. In silico modeling of strain energy distribution in the scaffolds reveal the importance of surgical fixation and mechanical loading on long-term bone regeneration. The clinical application of 3D-printed Sr-HT-Gahnite scaffolds as a synthetic bone substitute can potentially improve the repair of challenging bone defects and overcome the limitations of bone graft transplantation.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos , Alicerces Teciduais/química , Animais , Fenômenos Biomecânicos , Substitutos Ósseos/química , Substitutos Ósseos/farmacologia , Porosidade , Impressão Tridimensional , Ovinos , Tíbia/diagnóstico por imagem , Tíbia/efeitos dos fármacos , Tíbia/fisiologia , Microtomografia por Raio-X
13.
Adv Healthc Mater ; 8(1): e1801353, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30536610

RESUMO

The successful regeneration of functional bone tissue in critical-size defects remains a significant clinical challenge. To address this challenge, synthetic bone scaffolds are widely developed, but remarkably few are translated to the clinic due to poor performance in vivo. Here, it is demonstrated how architectural design of 3D printed scaffolds can improve in vivo outcomes. Ceramic scaffolds with different pore sizes and permeabilities, but with similar porosity and interconnectivity, are implanted in rabbit calvaria for 12 weeks, and then the explants are harvested for microcomputed tomography evaluation of the volume and functionality of newly formed bone. The results indicate that scaffold pores should be larger than 390 µm with an upper limit of 590 µm to enhance bone formation. It is also demonstrated that a bimodal pore topology-alternating large and small pores-enhances the volume and functionality of new bone substantially. Moreover, bone formation results indicate that stiffness of new bone is highly influenced by the scaffold's permeability in the direction concerned. This study demonstrates that manipulating pore size and permeability in a 3D printed scaffold architecture provides a useful strategy for enhancing bone regeneration outcomes.


Assuntos
Osteogênese , Impressão Tridimensional , Alicerces Teciduais/química , Animais , Teste de Materiais , Permeabilidade , Porosidade , Implantação de Prótese , Coelhos , Reologia , Microtomografia por Raio-X
14.
Nanomaterials (Basel) ; 8(10)2018 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-30322115

RESUMO

Lipid-based drugs are emerging as an interesting class of novel anticancer drugs with the potential to target specific cancer cell metabolic pathways linked to their proliferation and invasiveness. In particular, ω-3 polyunsaturated fatty acids (PUFA) derivatives such as epoxides and their bioisosteres have demonstrated the potential to suppress growth and promote apoptosis in triple-negative human breast cancer cells MDA-MB-231. In this study, 16-(4'-chloro-3'-trifluorophenyl)carbamoylamino]hexadecanoic acid (ClFPh-CHA), an anticancer lipid derived from ω-3,17,18-epoxyeicosanoic acid, was formulated as a stable nanoemulsion with size around 150 nm and narrow droplet size distribution (PDI < 0.200) through phase-inversion emulsification process followed by high pressure homogenization in view of an oral administration. The ClFPh-CHA-loaded nanoemulsions were able to significantly decrease the relative tumor volume in mice bearing an intramammary tumor xenograft at all doses tested (2.5, 10 and 40 mg/kg) after 32 days of daily oral administration. Furthermore, absolute tumor weight was decreased to 50% of untreated control at 10 and 40 mg/kg, while intraperitoneal administration could achieve a significant reduction only at the highest dose of 40 mg/kg. Results suggest that oral administration of ClFPh-CHA formulated as a nanoemulsion has a sufficient bioavailability to provide an anticancer effect in mice and that the activity is at least equal if not superior to that obtained by a conventional parenteral administration of equivalent doses of the same drug.

15.
Adv Healthc Mater ; 7(15): e1800218, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29877058

RESUMO

Extensive bone loss due to trauma or disease leads to impaired healing. Current bone grafts and substitutes have major drawbacks that limit their effectiveness for treating large bone defects. A number of bone substitutes in development are undergoing preclinical testing, but few studies specifically investigate the in vivo material-tissue interactions that provide an important indicator to long-term implant safety and efficacy. This study is the first of its kind to specifically investigate in vivo material-tissue interactions at the bone-implant interface. Baghdadite scaffolds implanted in critical-sized segmental defects in sheep tibia for 26 weeks are analyzed by focused ion beam scanning electron microscopy, multiphoton microscopy, and histology. The scaffolds are seen to induce extensive bone formation that directly abut the implant surfaces with no evidence of chronic inflammation or fibrous capsule formation. Bone remodeling is influenced by slow in vivo degradation around and within the implant, causing portions of the implant to be incorporated into the newly formed bone. These findings have important implications for predicting the long-term effects of baghdadite ceramics in promoting defect healing, and support the translation of baghdadite scaffolds as a new generation of bone graft substitutes with improved properties for the repair of large bone defects.


Assuntos
Regeneração Óssea/fisiologia , Animais , Remodelação Óssea , Substitutos Ósseos , Microscopia Eletroquímica de Varredura , Ovinos , Alicerces Teciduais/química
16.
J Med Chem ; 60(20): 8661-8666, 2017 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-28921987

RESUMO

Cancer cell mitochondria are promising anticancer drug targets because they control cell death and are structurally and functionally different from normal cell mitochondria. We synthesized arylurea fatty acids and found that the analogue 16-({[4-chloro-3-(trifluoromethyl)phenyl]carbamoyl}amino)hexadecanoic acid (13b) decreased proliferation and activated apoptosis in MDA-MB-231 breast cancer cells in vitro and in vivo. In mechanistic studies 13b emerged as the prototype of a novel class of mitochondrion-targeted agents that deplete cardiolipin and promote cancer cell death.


Assuntos
Neoplasias da Mama/patologia , Ácidos Graxos/farmacologia , Mitocôndrias/efeitos dos fármacos , Ureia/química , Animais , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Ácidos Graxos/química , Feminino , Humanos , Camundongos , Membranas Mitocondriais/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Oncotarget ; 8(16): 26687-26701, 2017 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-28460457

RESUMO

Vitamin D has pleiotropic effects on multiple tissues, including malignant tumors. Vitamin D inhibits breast cancer growth through activation of the vitamin D receptor (VDR) and via classical nuclear signaling pathways. Here, we demonstrate that the VDR can also function in the absence of its ligand to control behaviour of human breast cancer cells both outside and within the bone microenvironment. Stable shRNA expression was used to knock down VDR expression in MCF-7 cells, generating two VDR knockdown clonal lines. In ligand-free culture, knockdown of VDR in MCF-7 cells significantly reduced proliferation and increased apoptosis, suggesting that the VDR plays a ligand-independent role in cancer cell growth. Implantation of these VDR knockdown cells into the mammary fat pad of nude mice resulted in reduced tumor growth in vivo compared with controls. In the intra-tibial xenograft model, VDR knockdown greatly reduced the ability of the cells to form tumors in the bone microenvironment. The in vitro growth of VDR knockdown cells was rescued by the expression of a mutant form of VDR which is unable to translocate to the nucleus and hence accumulates in the cytoplasm. Thus, our data indicate that in the absence of ligand, the VDR promotes breast cancer growth both in vitro and in vivo and that cytoplasmic accumulation of VDR is sufficient to produce this effect in vitro. This new mechanism of VDR action in breast cancer cells contrasts the known anti-proliferative nuclear actions of the VDR-vitamin D ligand complex.


Assuntos
Neoplasias da Mama/metabolismo , Receptores de Calcitriol/metabolismo , Animais , Apoptose/genética , Neoplasias Ósseas/genética , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/patologia , Neoplasias da Mama/genética , Linhagem Celular Tumoral , Proliferação de Células , Citoplasma/metabolismo , Modelos Animais de Doenças , Feminino , Expressão Gênica , Técnicas de Silenciamento de Genes , Xenoenxertos , Humanos , Ligantes , Camundongos , Mutação , Osteosclerose/genética , Osteosclerose/metabolismo , Transporte Proteico , Receptores de Calcitriol/genética , Vitamina D/metabolismo
18.
Int J Biochem Cell Biol ; 80: 173-178, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27720933

RESUMO

Secondary metastases are the leading cause of mortality in patients with breast cancer. Cytochrome P450 (CYP) 2J2 (CYP2J2) is upregulated in many human tumors and generates epoxyeicosanoids from arachidonic acid that promote tumorigenesis and metastasis, but at present there is little information on the genes that mediate these actions. In this study MDA-MB-468 breast cancer cells were stably transfected with CYP2J2 (MDA-2J2 cells) and Affymetrix microarray profiling was undertaken. We identified 182 genes that were differentially expressed in MDA-2J2 cells relative to control (MDA-CTL) cells (log[fold of control] ≥2). From gene ontology pathway analysis bone morphogenetic protein (BMP) receptor 1B (BMPR1B) emerged as an important upregulated gene in MDA-2J2 cells. Addition of the BMPR1B ligand BMP2 stimulated the migration of MDA-2J2 cells, but not MDA-CTL cells, from 3D-matrigel droplets. Migration of MDA-2J2 cells was prevented by the BMPR antagonist dorsomorphin. These findings indicate that over-expression of CYP2J2 in MDA-MB-468-derived breast cancer cells activates BMPR1B expression that may contribute to increased migration. Targeting BMPR1B may be a novel approach to inhibit the metastatic activity of breast cancers that contain high levels of CYP2J2.


Assuntos
Receptores de Proteínas Morfogenéticas Ósseas Tipo I/genética , Movimento Celular/genética , Sistema Enzimático do Citocromo P-450/genética , Ativação Transcricional , Neoplasias de Mama Triplo Negativas/patologia , Carcinogênese/genética , Linhagem Celular Tumoral , Citocromo P-450 CYP2J2 , Expressão Gênica , Ontologia Genética , Humanos , Metástase Neoplásica , Regulação para Cima/genética
19.
Sci Rep ; 6: 28816, 2016 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-27403936

RESUMO

Healing large bone defects, especially in weight-bearing locations, remains a challenge using available synthetic ceramic scaffolds. Manufactured as a scaffold using 3D printing technology, Sr-HT-Gahnite at high porosity (66%) had demonstrated significantly improved compressive strength (53 ± 9 MPa) and toughness. Nevertheless, the main concern of ceramic scaffolds in general remains to be their inherent brittleness and low fracture strength in load bearing applications. Therefore, it is crucial to establish a robust numerical framework for predicting fracture strengths of such scaffolds. Since crack initiation and propagation plays a critical role on the fracture strength of ceramic structures, we employed extended finite element method (XFEM) to predict fracture behaviors of Sr-HT-Gahnite scaffolds. The correlation between experimental and numerical results proved the superiority of XFEM for quantifying fracture strength of scaffolds over conventional FEM. In addition to computer aided design (CAD) based modeling analyses, XFEM was conducted on micro-computed tomography (µCT) based models for fabricated scaffolds, which took into account the geometric variations induced by the fabrication process. Fracture strengths and crack paths predicted by the µCT-based XFEM analyses correlated well with relevant experimental results. The study provided an effective means for the prediction of fracture strength of porous ceramic structures, thereby facilitating design optimization of scaffolds.


Assuntos
Cerâmica/química , Alicerces Teciduais/química , Suporte de Carga , Regeneração Óssea , Substitutos Ósseos , Força Compressiva , Desenho Assistido por Computador , Análise de Elementos Finitos , Fraturas Ósseas/terapia , Humanos , Teste de Materiais , Porosidade , Pressão , Impressão Tridimensional , Estresse Mecânico , Engenharia Tecidual/métodos , Microtomografia por Raio-X
20.
J Mech Behav Biomed Mater ; 62: 433-445, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27281161

RESUMO

The most common methods for attaching a device to the internal tissues of the human body are via sutures, clips or staples. These attachment techniques require penetration and manipulation of the tissue. Tears and leaks can often be a complication post-attachment, and scarring usually occurs around the attachment sites. To resolve these issues, it is proposed to develop a soft tissue scaffold impregnated with Rose Bengal/Chitosan solution (RBC-scaffold, 0.01% w/v Rose Bengal, 1.7% w/v Medium Molecular Weight Chitosan). This scaffold will initially attach to the tissue via a light activation method. The light activates the dye in the scaffold which causes cross-links to form between the scaffold and tissue, thus adhering them together. This is done without mechanically manipulating the surrounding tissue, thus avoiding the issues associated with current techniques. Eventually, the scaffold will be resorbed and tissue will integrate for long-term attachment. A variety of tests were performed to characterise the RBC-scaffold. Porosity, interconnectivity, and mechanical strength were measured. Light activation was performed with a broad spectrum (380-780nm) 10W LED lamp exposed to various time lengths (2-15min, Fluence range 0.4-3J/cm(2) ). Adhesive strength of the light-activated bond was measured with lap-shear tests performed on porcine stomach tissue. Cell culture viability was also assessed to confirm tissue integration potential. These properties were compared to Variotis™, an aliphatic polyester soft tissue scaffold which has proven to be viable for soft tissue regeneration. The RBC-scaffolds were found to have high porosity (86.46±2.95%) and connectivity, showing rapid fluid movement. The elastic modulus of the RBC-scaffolds (3.55±1.28MPa) was found to be significantly higher than the controls (0.15±0.058MPa, p<0.01) and approached reported values for human gastrointestinal tissue (2.3MPa). The maximum adhesion strength achieved of the RBC-scaffolds was 8.61±2.81kPa after 15min of light activation, this is comparable to the adhesion strength of fibrin glue on scaffolds. Cell attachment was seen to be similar to the controls, but cells appeared to have better cell survivability. In conclusion, the RBC-scaffolds show promise for use as a novel light activated attachment device with potential applications in attaching an anti-reflux valve in the lower oesophagus and also in wound healing applications for stomach ulcers.


Assuntos
Adesivos , Luz , Alicerces Teciduais , Animais , Quitosana/química , Humanos , Teste de Materiais , Poliésteres , Porosidade , Rosa Bengala/química , Estômago/fisiologia , Suínos , Engenharia Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...