Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
1.
Arch Cardiovasc Dis ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38670869

RESUMO

BACKGROUND: Transcatheter (TAVR) has supplanted surgical (SAVR) aortic valve replacement (AVR). AIM: To evaluate whether adoption of this technology has varied according to centre volume at the nationwide level. METHODS: From an administrative hospital-discharge database, we collected data on all AVRs performed in France between 2007 and 2019. Centres were divided into terciles based on the annual number of SAVRs performed in 2007-2009 ("before TAVR era"). RESULTS: A total of 192,773 AVRs (134,662 SAVRs and 58,111 TAVRs) were performed in 47 centres. The annual number of AVRs and TAVRs increased significantly and linearly in low-volume (<152 SAVRs/year; median 106, interquartile range [IQR] 75-129), middle-volume (152-219 SAVRs/year; median 197, IQR 172-212) and high-volume (>219 SAVRs/year; median 303, IQR 268-513) terciles, but to a greater degree in the latter (+14, +16 and +24 AVRs/centre/year and +16, +19 and +31 TAVRs/centre/year, respectively; PANCOVA<0.001). Charlson Comorbidity Index and in-hospital death rates declined from 2010 to 2019 in all terciles (all Ptrend<0.05). In 2017-2019, after adjusting for age, sex and Charlson Comorbidity Index, there was a trend toward lower death rates in the high-volume tercile (P=0.06) for SAVR, whereas death rates were similar for TAVR irrespective of tercile (P=0.27). Similar results were obtained when terciles were defined based on number of interventions performed in the last instead of the first 3years. Importantly, even centres in the lowest-volume tercile performed a relatively high number of interventions (150 TAVRs/year/centre). CONCLUSIONS: In a centralized public healthcare system, the total number of AVRs increased linearly between 2007 and 2019, mostly due to an increase in TAVR, irrespective of centre volume. Progressive declines in patient risk profiles and death rates were observed in all terciles; in 2017-2019 death rates were similar in all terciles, although lower in high-volume centres for SAVR.

2.
Eur Heart J ; 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.

4.
Eur Heart J ; 45(11): 952-962, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38437633

RESUMO

BACKGROUND AND AIMS: The length of stay (LOS) after transcatheter aortic valve implantation (TAVI) remains extremely variable whereas early discharge has been shown to be feasible and safe. The study objective was to evaluate the efficacy and safety of an intervention aimed at reducing LOS after transfemoral TAVI. METHODS: FAST-TAVI II is a prospective, multicentre, cluster, randomized, controlled study including patients with severe symptomatic aortic stenosis, who had transfemoral TAVI. The intervention consisted in a dedicated training programme to implement 10 quality of care measures to reduce LOS with an implementation phase of eight weeks. The primary endpoint was the proportion of patients discharged early within 3 days. Secondary endpoints included: LOS, 30-day mortality and 30-day incidence of readmission for cardiovascular events. RESULTS: During the study period, 969 patients were enrolled in the intervention group and 860 patients in the control group. Mean age was 81.9 ± 6.6 years and mean EuroSCORE II was 4.4 ± 4.5%. Early discharge was achieved in 563 (58.1%) patients in the intervention group vs. 364 (42.3%) patients in the control group (P < .0001). Median LOS was significantly reduced in the intervention group compared to the control group [3 (IQR: 3) vs. 4 days (IQR: 3), P < .0001]. Thirty-day mortality was low and similar in the two groups (0.5% vs. 0.9%, P = .30), as were 30-day readmissions (4.6% vs. 2.8%, P = .28). CONCLUSIONS: The intervention was simple and fast to implement, and was effective and safe to reduce LOS and increase the proportion of patients discharged early after TAVI (NCT04503655).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Tempo de Internação , Estudos Prospectivos , Alta do Paciente , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
5.
Front Bioinform ; 4: 1321508, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343649

RESUMO

The current richness of sequence data needs efficient methodologies to display and analyze the complexity of the information in a compact and readable manner. Traditionally, phylogenetic trees and sequence similarity networks have been used to display and analyze sequences of protein families. These methods aim to shed light on key computational biology problems such as sequence classification and functional inference. Here, we present a new methodology, AlignScape, based on self-organizing maps. AlignScape is applied to three large families of proteins: the kinases and GPCRs from human, and bacterial T6SS proteins. AlignScape provides a map of the similarity landscape and a tree representation of multiple sequence alignments These representations are useful to display, cluster, and classify sequences as well as identify functional trends. The efficient GPU implementation of AlignScape allows the analysis of large MSAs in a few minutes. Furthermore, we show how the AlignScape analysis of proteins belonging to the T6SS complex can be used to predict coevolving partners.

7.
Nat Commun ; 15(1): 429, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200008

RESUMO

The type VI secretion system (T6SS) of Gram-negative bacteria inhibits competitor cells through contact-dependent translocation of toxic effector proteins. In Proteobacteria, the T6SS is anchored to the cell envelope through a megadalton-sized membrane complex (MC). However, the genomes of Bacteroidota with T6SSs appear to lack genes encoding homologs of canonical MC components. Here, we identify five genes in Bacteroides fragilis (tssNQOPR) that are essential for T6SS function and encode a Bacteroidota-specific MC. We purify this complex, reveal its dimensions using electron microscopy, and identify a protein-protein interaction network underlying the assembly of the MC including the stoichiometry of the five TssNQOPR components. Protein TssN mediates the connection between the Bacteroidota MC and the conserved baseplate. Although MC gene content and organization varies across the phylum Bacteroidota, no MC homologs are detected outside of T6SS loci, suggesting ancient co-option and functional convergence with the non-homologous MC of Pseudomonadota.


Assuntos
Sistemas de Secreção Tipo VI , Sistemas de Secreção Tipo VI/genética , Membranas , Bacteroidetes , Membrana Celular , Parede Celular
8.
Arch Cardiovasc Dis ; 117(2): 143-152, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38267317

RESUMO

BACKGROUND: The coronavirus disease of 2019 (COVID-19) pandemic lockdowns limited access to medical care. The impact on surgical (SAVR) and transcatheter (TAVR) aortic valve replacement (AVR) has been poorly described. AIM: We sought to evaluate the impact of the COVID-19 pandemic on the number and modalities of AVR, patient demographics and in-hospital outcomes at the nationwide level. METHODS: Using the French nationwide administrative hospital discharge database, we compared projected numbers and proportions of AVR and hospital outcomes, obtained using linear regressions derived from 2015-2019 trends, with those observed in 2020. RESULTS: In 2020, 21,382 AVRs were performed (13,051 TAVRs, 5706 isolated SAVRs and 2625 SAVRs combined with other cardiac surgery). Compared with the 2020 projected number of AVRs (24,586, 95% confidence interval [CI] 23,525-25,646), TAVRs (14,866, 95% CI 14,164-15,568), isolated SAVRs (6652, 95% CI 6203-7100) and SAVRs combined with other cardiac surgery (3069, 95% CI 2822-3315), there were reductions of 13.0%, 12.2%, 14.2% and 14.5%, respectively. These trends were similar regardless of sex or age. In 2020, the mean age, Charlson Comorbidity Index and hospital admission duration continued to decline, and the proportion of females remained constant, following 2015-2019 trends. Overall, 2020 in-hospital mortality was higher than projected (2.0% observed vs. 1.7% projected; 95% CI 1.5-1.9%), with no increased pacemaker implantation, but more acute kidney injury and cerebrovascular accidents in some surgical subsets. CONCLUSIONS: During the COVID-19 pandemic, fewer TAVR and SAVR procedures were performed, with increased in-hospital mortality and periprocedural complications. Extended follow-up will be important to establish the long-term effect of the COVID-19 pandemic on patient management and outcomes.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Complicações Pós-Operatórias , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Mortalidade Hospitalar , França/epidemiologia
9.
Eur J Cardiovasc Nurs ; 23(3): 296-304, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37610363

RESUMO

AIMS: Early mobilization is associated with improved outcomes in hospitalized older patients. We sought to determine the effect of a nurse-led protocol on mobilization 4 h after transfemoral transcatheter aortic valve implantation (TAVI) across different units of care. METHODS AND RESULTS: We conducted a prospective observational cohort single-centre study of consecutive patients. We implemented a standardized protocol for safe early recovery and progressive mobilization in the critical care and cardiac telemetry units. We measured the time to first mobilization and conducted descriptive statistics to identify patient and system barriers to timely ambulation. We recruited 139 patients (82.5 years, SD = 6.7; 46% women). At baseline, patients who were mobilized early (≤4 h) and late (>4 h) did not differ, except for higher rates of diabetes (25.5% vs. 43.9%, P = 0.032) and peripheral arterial disease (8.2% vs. 26.8%, P = 0.003) in the late mobilization group. The median time to mobilization was 4 h [inter-quartile range (IQR) 3.25, 4]; 98 patients (70.5%) were mobilized successfully after 4 h of bedrest; 118 (84.9%) were walking by the evening of the procedure (<8 h bedrest); and 21 (15.1%) were on bedrest overnight and mobilized the following day. Primary reasons for overnight bedrest were arrhythmia monitoring (n = 10, 7.2%) and haemodynamic and/or neurological instability (n = 6, 4.3%); six patients (4.3%) experienced delayed ambulation due to system issues. Procedure location in the hybrid operating room and transfer to critical care were associated with longer bedrest times. CONCLUSION: Standardized nurse-led mobilization 4 h after TF TAVI is feasible in the absence of clinical complications and system barriers.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Deambulação Precoce , Resultado do Tratamento , Fatores de Tempo , Estudos de Coortes
10.
Can J Cardiol ; 40(1): 113-122, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37726077

RESUMO

BACKGROUND: Data on the long-term impact of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement (TAVR) remain sparse. We therefore aimed to investigate the incidence, predictive factors, and long-term prognostic impact of PPM on bioprosthesis durability and mortality. METHODS: This was a single-centre retrospective study including 2117 patients who underwent TAVR for aortic stenosis from 2002 to 2022. Moderate PPM was defined by indexed effective orifice area (iEOA) > 0.65 and ≤ 0.85 cm2/m2 (> 0.55 and ≤ 0.70 cm2/m2 if BMI ≥ 30 kg/m2) and severe PPM by an iEOA ≤ 0.65 cm2/m2 (≤ 0.55 cm2/m2 If BMI ≥ 30 kg/m2). RESULTS: There were 351 patients (16.6%) with PPM, including 39 patients (1.8%) with severe PPM and 312 patients (14.7%) with moderate PPM. The mean follow-up duration was 31.2 ± 26.5 months. Factors independently associated with the occurrence of PPM were body surface area (odds ratio [OR] 3.32, 95% confidence interval [CI] 1.32-8.35; P = 0.01), valve-in-valve TAVR (OR 6.12, 95% CI 2.29-16.08; P < 0.001), small annulus (OR 2.42, 95% CI 1.41-4.07; P = 0.001), and the use of a balloon-expandable valve (OR 4.17, 95% CI 2.17-8.33; P < 0.001). PPM was associated with increased risk of mortality (hazard ratio [HR] 1.3, 95% CI 1.1-1.5, P = 0.004) and valve thrombosis (HR 4.2, 95% CI 1.4-12.6, P = 0.01), and a trend towards increased risk of structural valve deterioration (HR 1.7, 95% CI 0.9-2.9; P = 0.08). CONCLUSIONS: The results of this study suggest that PPM has a negative long-term impact on outcomes after TAVR. These findings emphasise the importance of preventing PPM.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/cirurgia , Fatores de Risco
11.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-37552784

RESUMO

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco
12.
J Am Coll Cardiol ; 82(20): 1889-1902, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37877906

RESUMO

BACKGROUND: Current guidelines recommend selecting surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) based on age, comorbidities, and surgical risk. Nevertheless, reports from the United States suggest a rapid expansion of TAVR in young patients. OBJECTIVES: The authors sought to evaluate the trends in TAVR uptake at a nationwide level in France according to age and sex. METHODS: Using a nationwide administrative database, we evaluated age- and sex-related trends in TAVR uptake, patient demographics, and in-hospital outcomes between 2015 and 2020. RESULTS: A total of 107,397 patients (44.0% female) underwent an isolated aortic valve replacement (AVR) (59.1% TAVR, 40.9% SAVR). In patients <65 years of age, the proportion of TAVR increased by 63.2% (P < 0.001) from 2015 to 2020 but remained uncommon at 11.1% of all AVR by 2020 (12.4% in females, 10.6% in males) while TAVR was the dominant modality in patients ≥65 years of age. In patients undergoing TAVR, the Charlson comorbidity index (CCI) (P = 0.119 for trend) and in-hospital mortality (P = 0.740 for trend) remained unchanged in patients <65 years of age but declined in those ≥65 years of age irrespective of sex (all P < 0.001 for trends). Females were older (P < 0.001), had lower CCI (P < 0.001), were more likely to undergo TAVR (P < 0.001), and experienced higher in-hospital mortality (TAVR, P = 0.015; SAVR, P < 0.001) that persisted despite adjustment for age and CCI. CONCLUSIONS: In France, the use of TAVR remained uncommon in young patients, predominantly restricted to those at high risk. Important sex differences were observed in patent demographics, selection of AVR modality, and patient outcomes. Additional research evaluating the long-term impact of TAVR use in young patients and prospective data evaluating sex differences in AVR modality selection and outcomes are needed.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estados Unidos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , França/epidemiologia
13.
PLoS Pathog ; 19(9): e1011687, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37769028

RESUMO

A. baumannii can rapidly acquire new resistance mechanisms and persist on abiotic surface, enabling the colonization of asymptomatic human host. In Acinetobacter the type VI secretion system (T6SS) is involved in twitching, surface motility and is used for interbacterial competition allowing the bacteria to uptake DNA. A. baumannii possesses a T6SS that has been well studied for its regulation and specific activity, but little is known concerning its assembly and architecture. The T6SS nanomachine is built from three architectural sub-complexes. Unlike the baseplate (BP) and the tail-tube complex (TTC), which are inherited from bacteriophages, the membrane complex (MC) originates from bacteria. The MC is the most external part of the T6SS and, as such, is subjected to evolution and adaptation. One unanswered question on the MC is how such a gigantesque molecular edifice is inserted and crosses the bacterial cell envelope. The A. baumannii MC lacks an essential component, the TssJ lipoprotein, which anchors the MC to the outer membrane. In this work, we studied how A. baumannii compensates the absence of a TssJ. We have characterized for the first time the A. baumannii's specific T6SS MC, its unique characteristic, its membrane localization, and assembly dynamics. We also defined its composition, demonstrating that its biogenesis employs three Acinetobacter-specific envelope-associated proteins that define an intricate network leading to the assembly of a five-proteins membrane super-complex. Our data suggest that A. baumannii has divided the function of TssJ by (1) co-opting a new protein TsmK that stabilizes the MC and by (2) evolving a new domain in TssM for homo-oligomerization, a prerequisite to build the T6SS channel. We believe that the atypical species-specific features we report in this study will have profound implication in our understanding of the assembly and evolutionary diversity of different T6SSs, that warrants future investigation.

14.
Nat Commun ; 14(1): 4461, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491334

RESUMO

Epigenetic regulation of histone H3K27 methylation has recently emerged as a key step during alternative immunoregulatory M2-like macrophage polarization; known to impact cardiac repair after Myocardial Infarction (MI). We hypothesized that EZH2, responsible for H3K27 methylation, could act as an epigenetic checkpoint regulator during this process. We demonstrate for the first time an ectopic EZH2, and putative, cytoplasmic inactive localization of the epigenetic enzyme, during monocyte differentiation into M2 macrophages in vitro as well as in immunomodulatory cardiac macrophages in vivo in the post-MI acute inflammatory phase. Moreover, we show that pharmacological EZH2 inhibition, with GSK-343, resolves H3K27 methylation of bivalent gene promoters, thus enhancing their expression to promote human monocyte repair functions. In line with this protective effect, GSK-343 treatment accelerated cardiac inflammatory resolution preventing infarct expansion and subsequent cardiac dysfunction in female mice post-MI in vivo. In conclusion, our study reveals that pharmacological epigenetic modulation of cardiac-infiltrating immune cells may hold promise to limit adverse cardiac remodeling after MI.


Assuntos
Monócitos , Infarto do Miocárdio , Animais , Feminino , Humanos , Camundongos , Diferenciação Celular , Epigênese Genética , Macrófagos/metabolismo , Camundongos Endogâmicos C57BL , Monócitos/metabolismo , Infarto do Miocárdio/metabolismo , Miocárdio/metabolismo
15.
Eur Radiol ; 33(12): 8521-8527, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37470824

RESUMO

OBJECTIVES: To assess feasibility and accuracy of aortic annulus measurements using cardiac computed tomography angiography (CTA) performed during free-breathing prior to transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Sixty consecutive TAVR candidates underwent free-breathing wide-detector cardiac CTA, followed by a percutaneous valve replacement. For each, a theoretical valve size was suggested through CT measurements of the annulus, then compared to the size of the actual implanted transcatheter heart valve (THV). The procedural success and the 30-day outcomes were collected. Image quality of the annulus was also studied according to subjective and objective criteria. Data of a control group of 60 patients previously evaluated on breath-holding were also evaluated. RESULTS: A total of 120 patients (mean age, 83 years ± 7, 60 men) were evaluated. All CT acquisitions provided sufficient image quality allowing precise annulus measurements. Mean attenuation (p < 0.001) and image noise (p = 0.01) were higher in the free-breathing group, while image quality was comparable (p = 0.36). The agreement rate between CT-suggested valve size and THV implanted size was comparable, estimated at 87% (κ = 0.79, 95%CI 0.566, 0.908) on free-breathing vs. 82% (κ = 0.78, 95%CI 0.634, 0.904) on breath-holding. The procedure was successful for all patients without increase in 30-day mortality or adverse events. CONCLUSIONS: Free-breathing cardiac CTA allows accurate aortic annulus measurements without compromising image quality or patients' outcome after TAVR. Elderly patients experiencing dyspnea, discomfort, or hearing loss that could prevent proper breath-holding should not be excluded from CT prior to TAVR. CLINICAL RELEVANCE STATEMENT: To decrease elderly patients' discomfort, MDCT evaluation prior to transcatheter aortic valve replacement (TAVR) may be performed on quiet breathing with no significant impact on the outcome. KEY POINTS: • Adhering to CT breathing commands can be challenging for patients with dyspnea, hearing impairment, agitation, or pulmonary diseases. • Free-breathing cardiac CT may be an alternative to breath-holding for patients unable to follow the breathing commands. • Wide-detector CT acquisition on free-breathing does not impair annulus measurements and prosthesis sizing in patients scheduled for TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Dispneia , Tomografia Computadorizada Multidetectores/métodos , Resultado do Tratamento , Desenho de Prótese , Valor Preditivo dos Testes
16.
J Clin Med ; 12(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36836075

RESUMO

Introduction. This study addressed the hypothesis that subtotal nephrectomy associated with a high-phosphorus diet (5/6Nx + P) in rats represents a suitable animal model to mimic the cardiovascular consequences of chronic kidney disease (CKD) including calcified aortic valve disease (CAVD). Indeed, the latter contributes to the high morbidity and mortality of CKD patients and sorely lacks preclinical models for pathophysiological and pharmacological studies. Methods. Renal and cardiovascular function and structure were compared between sham-operated and 5/6 Nx rats + P 10 to 12 weeks after surgery. Results. As expected, 11 weeks after surgery, 5/6Nx + P rats developed CKD as demonstrated by their increase in plasma creatinine and urea nitrogen and decrease in glomerular filtration rate, estimated by using fluorescein-isothiocyanate-labelled sinistrin, anemia, polyuria, and polydipsia compared to sham-operated animals on a normal-phosphorus diet. At the vascular level, 5/6Nx + P rats had an increase in the calcium content of the aorta; a decrease in mesenteric artery dilatation in response to a stepwise increase in flow, illustrating the vascular dysfunction; and an increase in blood pressure. Moreover, immunohistology showed a marked deposition of hydroxyapatite crystals in the aortic valve of 5/6Nx + P rats. Echocardiography demonstrated that this was associated with a decrease in aortic valve cusp separation and an increase in aortic valve mean pressure gradient and in peak aortic valve velocity. Left-ventricular diastolic and systolic dysfunction as well as fibrosis were also present in 5/6Nx + P rats. Conclusion. This study demonstrates that 5/6Nx + P recapitulates the cardiovascular consequences observed in humans with CKD. In particular, the initiation of CAVD was shown, highlighting the interest of this animal model to study the mechanisms involved in the development of aortic stenosis and test new therapeutic strategies at an early stage of the disease.

17.
Sci Adv ; 9(8): eabq0619, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36812310

RESUMO

The predatory deltaproteobacterium Myxococcus xanthus uses a helically-trafficked motor at bacterial focal-adhesion (bFA) sites to power gliding motility. Using total internal reflection fluorescence and force microscopies, we identify the von Willebrand A domain-containing outer-membrane (OM) lipoprotein CglB as an essential substratum-coupling adhesin of the gliding transducer (Glt) machinery at bFAs. Biochemical and genetic analyses reveal that CglB localizes to the cell surface independently of the Glt apparatus; once there, it is recruited by the OM module of the gliding machinery, a heteroligomeric complex containing the integral OM ß barrels GltA, GltB, and GltH, as well as the OM protein GltC and OM lipoprotein GltK. This Glt OM platform mediates the cell-surface accessibility and retention of CglB by the Glt apparatus. Together, these data suggest that the gliding complex promotes regulated surface exposure of CglB at bFAs, thus explaining the manner by which contractile forces exerted by inner-membrane motors are transduced across the cell envelope to the substratum.


Assuntos
Myxococcales , Myxococcales/metabolismo , Adesões Focais/metabolismo , Adesinas Bacterianas , Aderência Bacteriana , Lipoproteínas , Proteínas de Bactérias/metabolismo
18.
EuroIntervention ; 18(16): e1339-e1347, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36602883

RESUMO

BACKGROUND: R-One is a robotic percutaneous coronary intervention (PCI) system (CE mark 2019) designed to reduce operator radiation exposure, improve ergonomics, and accurately navigate, position, and deliver guidewires/devices during PCI. AIMS: We aimed to evaluate the safety and efficacy of the R-One system for PCI. METHODS: The European multicentre prospective R-EVOLUTION study included patients with a de novo coronary artery stenosis (length <38 mm, reference diameter 2.5-4.0 mm) undergoing stent implantation. Patients with recent ST-segment elevation myocardial infarction, ostial or left main lesion, bifurcation, severe tortuosity, or calcification were excluded. Clinical success was defined as the absence of major intraprocedural complications. Technical success was defined as the successful advancement and retraction of all PCI devices (guidewires/balloon/stents) without total manual conversion. Radiation exposure to patients, to a simulated manual operator, and to robotic PCI operators was measured. RESULTS: Sixty-two consecutive patients (B2/C lesions: 25.0% [16/64]) underwent robotic PCI. Radial access was used in 96.8% (60/62) of procedures. The mean robotic procedure duration was 19.9±9.6 min and the mean fluoroscopy time was 10.3±5.4 min. Clinical success was 100% with no complications at 30 days. Technical success was 95.2% (59/62). Total manual conversion was required in 4.8% (3/62) cases, with 1 case directly related to the robotic system. Operator radiation exposure was reduced by 84.5% under and 77.1% on top of the lead apron, compared to doses received on the patient table. CONCLUSIONS: This study suggests that robotic PCI using R-One is safe and effective with markedly lower radiation exposure to the operator. Further studies are needed to evaluate R-One in larger patient populations with more complex lesions. (ClinicalTrials.gov: NCT04163393).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
19.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36331961

RESUMO

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Incidência , Fatores de Risco , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Ecocardiografia
20.
Front Cardiovasc Med ; 10: 1320001, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38292452

RESUMO

Introduction: Dual antithrombotic therapy (DAT) combining oral anticoagulation (OAC), preferentially Non-vitamin K antagonist OAC (NOAC) and single antiplatelet therapy (SAPT) for a period of 6-12 months is recommended after percutaneous coronary intervention (PCI) in patients with an indication for OAC. Objective: To compare outcomes between vitamin K antagonist (VKA) and NOAC-treated patients in the nation-wide France PCI registry. Methods: All consecutive patients from the France PCI registry treated by PCI and discharged with OAC between 2014 and 2020 were included and followed one-year. Major bleeding was defined as Bleeding Academic Research Consortium (BARC) classification ≥3 and major adverse cardiac events (MACE) as the composite of all-cause mortality, myocardial infarction (MI), and ischemic stroke. A propensity-score analysis was used. Results: Of the 7,277 eligible participants, 2,432 (33.4%) were discharged on VKA and 4,845 (66.6%) on NOAC. After propensity-score adjustment, one-year major bleeding was less frequent in NOAC vs. VKA-treated participants [3.1% vs. 5.2%, -2.1% (-3.6% to -0.6%), p = 0.005 as well as the rate of MACE [9.2% vs. 11.9%, -2.7% (-5.0% to -0.4%), p = 0.02]. One-year mortality was also significantly decreased in NOAC vs. VKA-treated participants [7.4% vs. 9.9%, -2.6% (-4.7% to -0.5%), p = 0.02]. The area under ROC curves of the anticoagulant treatment propensity score was estimated at 0.93, suggesting potential indication bias. Conclusions: NOAC seems to have a better efficacy and safety profile than VKA. However, potential indication bias were found.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...