Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol Prot ; 41(4)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33975295

RESUMO

The International Commission on Radiation Units and Measurements (ICRU) Report Number 95 (2020 Operational quantities for external radiation exposureICRU Rep. 95 J. ICRU20) recommends new definitions ffor operational quantities as estimators of the International Commission on Radiological Protection radiation protection quantities. As part of this report, dose coefficients for neutron fluences are included for energies from 10-9-50 MeV. For lens of the eye dosimetry, several changes in the ICRU recommended quantities are of particular interest. First, an updated eye model is used that includes segmentation of the sensitive lens region. In addition, the use of absorbed dose instead of dose equivalent has been selected as the appropriate operational quantity since deterministic (i.e. non-stochastic) effects are of primary importance for the lens of the eye. The ICRU report also addresses computational parameters, such as absorbed dose tally volumes, depths, source areas and source rotational angles. In this work, neutron dose coefficients calculated for the lens of the eye in support of the ICRU report are presented. Dose coefficients for mono-energetic neutrons and reference neutron spectra are presented. The source is a parallel beam, and the mono-energetic dose coefficients are provided for rotational angles with respect to the front face of the head ranging from 0°-90°. In addition, monoenergetic dose coefficients for the parallel beam incident on the back of the head (180°) and for a rotational source geometry where the head is irradiated from all angles are reported. For all scenarios, absorbed doses to the complete lens and the sensitive volume of each eye were calculated. Eye lens absorbed dose coefficients,Dp,slab(3,0)/Φ, were also calculated in an ICRU tissue slab phantom at a depth of 3 mm for a parallel beam irradiating the slab perpendicular to the front face, and these results are compared to the values determined using the eye phantom.


Assuntos
Cristalino , Proteção Radiológica , Nêutrons , Doses de Radiação , Radiometria
3.
J Radiol Prot ; 40(2): 554-582, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32176871

RESUMO

A draft report by the International Commission on Radiation Units and Measurements (ICRU) Report Committee 26 (RC26) will recommend alternative definitions of the operational quantities that are better estimators of radiation protection quantities. Dose coefficients for use with physical field quantities-fluence and, for photons, air kerma-are given for various particle types over a broad energy range. For the skin dosimetry, several changes are of particular interest. Specifically, the use of absorbed dose instead of dose equivalent has been selected as the operational quantity since deterministic effects are of primary interest in the skin. In addition, newly recommended phantoms are specified for computing the operational dose coefficients. The report also addresses computational approaches such as tally volumes, depths, source areas, and rotational angles. In this work, dose coefficients calculated for local skin in support of the ICRU report are presented. Energy-dependent dose coefficients were calculated in phantoms specified for the trunk (slab), the ankle or wrist (pillar), and the finger (rod). The phantom specifications in this work were taken directly from the draft report. Full transport of secondary charged particles from neutron interactions was performed and an analysis of the depth-dose profiles in the slab phantom is presented, The last complete set of neutron dose coefficients for the extremities was published more than 25 years ago. Given the limited data available, it is difficult for many facilities to obtain clear guidance on how monitoring should be performed and how dosimeters should be calibrated so spectra from commonly encountered neutron sources were used to generate source-specific dose coefficients in each of the phantoms. Both energy-dependent and source-specific dose coefficients are provided for rotational angles up to 180 degrees for the rod and pillar phantoms and up to 75 degrees for the slab phantom.


Assuntos
Extremidades/efeitos da radiação , Nêutrons , Doses de Radiação , Radiometria/métodos , Pele/efeitos da radiação , Humanos , Modelos Anatômicos , Proteção Radiológica
6.
Radiat Environ Biophys ; 56(4): 453-462, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28840329

RESUMO

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Humanos , Imersão , Masculino , Exposição Ocupacional/normas , Imagens de Fantasmas , Padrões de Referência , Pele/efeitos da radiação
7.
Radiat Environ Biophys ; 56(3): 255-267, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28493137

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios.


Assuntos
Imagens de Fantasmas , Exposição à Radiação/análise , Radiometria/instrumentação , Poluentes Radioativos do Solo/análise , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido
8.
Radiat Prot Dosimetry ; 174(2): 275-286, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-27150517

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge (CRPK) has undertaken a number of calculations in support of a revision to the United States Environmental Protection Agency (US EPA) Federal Guidance Report on external exposure to radionuclides in air, water and soil (FGR 12). Age-specific mathematical phantom calculations were performed for the conditions of submersion in radioactive air and immersion in water. Dose rate coefficients were calculated for discrete photon and electron energies and folded with emissions from 1252 radionuclides using ICRP Publication 107 decay data to determine equivalent and effective dose rate coefficients. The coefficients calculated in this work compare favorably to those reported in FGR12 as well as by other authors that employed voxel phantoms for similar exposure scenarios.


Assuntos
Proteção Radiológica , Poluentes Radioativos , Ar , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação , Monitoramento de Radiação , Radioisótopos , Estados Unidos , Água
9.
Radiat Prot Dosimetry ; 175(1): 26-30, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27574318

RESUMO

Dose coefficients based on the recommendations of International Commission on Radiological Protection (ICRP) Publication 103 were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57 for the six reference irradiation geometries: anterior-posterior, posterior-anterior, right and left lateral, rotational and isotropic. In this work, dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and downward from above the head (cranial) using the ICRP 103 methodology were computed using the MCNP 6.1 radiation transport code. The dose coefficients were determined for neutrons ranging in energy from 10-9 MeV to 10 GeV. At energies below about 500 MeV, the cranial and caudal dose coefficients are less than those for the six reference geometries reported in ICRP Publication 116.


Assuntos
Nêutrons , Doses de Radiação , Proteção Radiológica , Simulação por Computador , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria
10.
Radiat Prot Dosimetry ; 174(4): 439-448, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27522048

RESUMO

In this article, methods are addressed to reduce the computational time to compute organ-dose rate coefficients using Monte Carlo techniques. Several variance reduction techniques are compared including the reciprocity method, importance sampling, weight windows and the use of the ADVANTG software package. For low-energy photons, the runtime was reduced by a factor of 105 when using the reciprocity method for kerma computation for immersion of a phantom in contaminated water. This is particularly significant since impractically long simulation times are required to achieve reasonable statistical uncertainties in organ dose for low-energy photons in this source medium and geometry. Although the MCNP Monte Carlo code is used in this paper, the reciprocity technique can be used equally well with other Monte Carlo codes.


Assuntos
Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Simulação por Computador , Fótons , Software , Água
11.
Ann ICRP ; 46(3-4): 1-486, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29380630

RESUMO

Abstract ­: The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988) and Publication 68 (ICRP, 1994). In addition, new data are now available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. OIR Part 1 has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. OIR Part 2 (ICRP, 2016), this current publication and upcoming publications in the OIR series (Parts 4 and 5) provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv Bq−1 intake) for inhalation and ingestion, tables of committed effective dose per content (Sv Bq−1 measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of publications contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. This third publication in the series provides the above data for the following elements: ruthenium (Ru), antimony (Sb), tellurium (Te), iodine (I), caesium (Cs), barium (Ba), iridium (Ir), lead (Pb), bismuth (Bi), polonium (Po), radon (Rn), radium (Ra), thorium (Th), and uranium (U).


Assuntos
Exposição Ocupacional/prevenção & controle , Saúde Ocupacional/normas , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radioisótopos/efeitos adversos , Relação Dose-Resposta à Radiação , Humanos , Exposição à Radiação/normas , Radiação Ionizante , Medição de Risco
12.
Radiat Prot Dosimetry ; 172(4): 367-374, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26838066

RESUMO

As part of a broader effort to calculate effective dose rate coefficients for external exposure to photons and electrons emitted by radionuclides distributed in air, soil or water, age-specific stylized phantoms have been employed to determine dose coefficients relating dose rate to organs and tissues in the body. In this article, dose rate coefficients computed using the International Commission on Radiological Protection reference adult male voxel phantom are compared with values computed using the Oak Ridge National Laboratory adult male stylized phantom in an air submersion exposure geometry. Monte Carlo calculations for both phantoms were performed for monoenergetic source photons in the range of 30 keV to 5 MeV. These calculations largely result in differences under 10 % for photon energies above 50 keV, and it can be expected that both models show comparable results for the environmental sources of radionuclides.


Assuntos
Modelos Teóricos , Neoplasias/radioterapia , Imagens de Fantasmas , Fótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Ar , Algoritmos , Carga Corporal (Radioterapia) , Elétrons , Humanos , Masculino , Método de Monte Carlo , Órgãos em Risco , Proteção Radiológica , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
13.
Ann ICRP ; 45(2): 5-73, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-29749258

RESUMO

Abstract ­: Dose coefficients for assessment of internal exposures to radionuclides are radiological protection quantities giving either the organ equivalent dose or effective dose per intake of radionuclide following ingestion or inhalation. In the International Commission on Radiological Protection's (ICRP) Occupational Intakes of Radionuclides (OIR) publication series, new biokinetic models for distribution of internalised radionuclides in the human body are presented as needed for establishing time-integrated activity within organs of deposition (source regions). This series of publications replaces Publications 30 and 68 (ICRP, 1979, 1980, 1981, 1988, 1994b). In addition, other fundamental data needed for computation of the dose coefficients are radionuclide decay data (energies and yields of emitted radiations), which are given in Publication 107 (ICRP, 2008), and specific absorbed fraction (SAF) values ­ defined as the fraction of the particle energy emitted in a source tissue region that is deposited in a target tissue region per mass of target tissue. This publication provides the technical basis for SAFs relevant to internalised radionuclide activity in the organs of Reference Adult Male and Reference Adult Female as defined in Publications 89 and 110 (ICRP, 2002, 2009). SAFs are given for uniform distributions of mono-energetic photons, electrons, alpha particles, and fission-spectrum neutrons over a range of relevant energies. Electron SAFs include both collision and radiative components of energy deposition. SAF data are matched to source and target organs of the biokinetic models of the OIR publication series, as well as the Publication 100 (ICRP, 2006) Human Alimentary Tract Model and the Publication 66 (ICRP, 1994a) Human Respiratory Tract Model, the latter as revised within Publication 130 (ICRP, 2015). This publication further outlines the computational methodology and nomenclature for assessment of internal dose in a manner consistent with that used for nuclear medicine applications. Numerical data for particle-specific and energy-dependent SAFs are given in electronic format for numerical coupling to the respiratory tract, alimentary tract, and systemic biokinetic models of the OIR publication series.

14.
Ann ICRP ; 45(3-4): 7-349, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28657340

RESUMO

Abstract ­: The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988b) and Publication 68 (ICRP, 1994b). In addition, new data are available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. Part 1 of the OIR series has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. The following publications in the OIR series (Parts 2­5) will provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv per Bq intake) for inhalation and ingestion, tables of committed effective dose per content (Sv per Bq measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of reports contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. The present publication provides the above data for the following elements: hydrogen (H), carbon (C), phosphorus (P), sulphur (S), calcium (Ca), iron (Fe), cobalt (Co), zinc (Zn), strontium (Sr), yttrium (Y), zirconium (Zr), niobium (Nb), molybdenum (Mo), and technetium (Tc).


Assuntos
Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radioisótopos , Relação Dose-Resposta à Radiação , Humanos , Saúde Ocupacional , Radiação Ionizante , Radiometria , Medição de Risco , Fatores de Risco
15.
Radiat Prot Dosimetry ; 168(2): 167-74, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25935016

RESUMO

With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above ∼30 MeV the cranial and caudal values are greater.


Assuntos
Núcleo Caudado/efeitos da radiação , Irradiação Craniana , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Fótons , Proteção Radiológica/normas , Adulto , Simulação por Computador , Feminino , Humanos , Masculino , Método de Monte Carlo , Doses de Radiação
16.
Ann ICRP ; 44(2): 5-188, 2015 09.
Artigo em Inglês | MEDLINE | ID: mdl-26494836

RESUMO

Abstract ­: This report is the first in a series of reports replacing Publications 30 and 68 to provide revised dose coefficients for occupational intakes of radionuclides by inhalation and ingestion. The revised dose coefficients have been calculated using the Human Alimentary Tract Model (Publication 100) and a revision of the Human Respiratory Tract Model (Publication 66) that takes account of more recent data. In addition, information is provided on absorption into blood following inhalation and ingestion of different chemical forms of elements and their radioisotopes. In selected cases, it is judged that the data are sufficient to make material-specific recommendations. Revisions have been made to many of the models that describe the systemic biokinetics of radionuclides absorbed into blood, making them more physiologically realistic representations of uptake and retention in organs and tissues, and excretion. The reports in this series provide data for the interpretation of bioassay measurements as well as dose coefficients, replacing Publications 54 and 78. In assessing bioassay data such as measurements of whole-body or organ content, or urinary excretion, assumptions have to be made about the exposure scenario, including the pattern and mode of radionuclide intake, physical and chemical characteristics of the material involved, and the elapsed time between the exposure(s) and measurement. This report provides some guidance on monitoring programmes and data interpretation.


Assuntos
Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação , Proteção Radiológica/normas , Relação Dose-Resposta à Radiação , Humanos , Saúde Ocupacional , Proteção Radiológica/métodos , Radiação Ionizante , Radiometria
17.
J Radiol Prot ; 35(2): 317-41, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25859888

RESUMO

This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit.


Assuntos
Materiais de Construção/análise , Habitação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Cinza Radioativa/análise , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Arquitetura de Instituições de Saúde , Humanos , Modelos Estatísticos , Doses de Radiação , Radiometria/métodos , Estados Unidos
18.
Radiat Prot Dosimetry ; 148(4): 507-13, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21531748

RESUMO

Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 × 10(-9) to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.


Assuntos
Catarata/prevenção & controle , Cristalino/efeitos da radiação , Nêutrons , Radiometria/métodos , Absorção , Algoritmos , Catarata/etiologia , Humanos , Modelos Estatísticos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos
19.
Radiat Prot Dosimetry ; 144(1-4): 314-20, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21036807

RESUMO

This paper describes new biokinetic and dosimetric models, especially those being developed by ICRP which will be used in the forthcoming documents on Occupational Intakes of Radionuclides. It also presents the results of a working group within the European project CONRAD which is being continued within EURADOS. This group is implementing the new models, performing quality assurance of the model implementation (including their description) and giving guidance to the scientific community on the application of the models for individual dose assessment.


Assuntos
Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radioisótopos/análise , Radiometria/instrumentação , Calibragem , Feminino , Raios gama , Trato Gastrointestinal/efeitos da radiação , Humanos , Cinética , Masculino , Modelos Biológicos , Modelos Teóricos , Controle de Qualidade , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/métodos
20.
Health Phys ; 99(4): 503-10, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20838091

RESUMO

The current dose coefficients for internal dose assessment of occupationally exposed persons and the general public were derived using the methodology of the International Commission on Radiological Protection (ICRP), which is similar to the Medical Internal Radiation Dose (MIRD)-type methodology. One component of this methodology is the mathematical representation of the human body (so-called MIRD-type phantoms) developed at the Oak Ridge National Laboratory for calculations of photon specific absorbed fractions (SAFs). Concerning the beta emissions, it is assumed in general that they irradiate only the organ where the radionuclide resides, whereas for walled organs, a fixed fraction of the emitted energy is absorbed within the wall. For the active marrow and bone surface targets, absorbed fractions were explicitly provided in ICRP Publication 30. The ICRP Publications 66 and 100 contain further detailed energy-dependent absorbed fraction data for the airways and the segments of the alimentary tract. In the present work, the voxel phantoms representing the reference male and female adults, recently developed at the Helmholtz Zentrum München-German Research Center for Environmental Health (HMGU) in collaboration with the Task Group DOCAL of ICRP Committee 2, were used for the Monte Carlo computation of photon as well as electron SAFs. These voxel phantoms, being constructed from computed tomography (CT) scans of individuals, are more realistic in shape and location of organs in the body than the mathematical phantoms; therefore, they provide photon SAFs that are more precise than those stemming from mathematical phantoms. In addition, electron SAFs for solid and walled organs as well as tissues in the alimentary tract, the respiratory tract, and the skeleton were calculated with Monte Carlo methods using these phantoms to complement the data of ICRP Publications 66 and 100 that are confined to self-irradiation. The SAFs derived for photons and electrons are then used to calculate the dose coefficients of the beta emitters 141Ce, 144Ce, 95Zr, and 90Sr. It is found that the differences of the dose coefficients due to the revised SAFs are much larger for injection and ingestion than for inhalation. The equivalent doses for colon and ingestion with the new voxel-based SAFs are significantly smaller than the values with the MIRD-type photon SAFs and simplifying assumptions for electrons. For lungs and inhalation, no significant difference was observed for the equivalent doses, whereas for injection and ingestion, an increase of the new values is observed.


Assuntos
Radioisótopos de Cério , Simulação por Computador , Elétrons , Imagens de Fantasmas , Fótons , Radiometria , Radioisótopos de Estrôncio , Zircônio , Idoso , Algoritmos , Partículas beta , Radioisótopos de Cério/análise , Radioisótopos de Cério/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas/normas , Doses de Radiação , Esqueleto , Radioisótopos de Estrôncio/análise , Radioisótopos de Estrôncio/química , Distribuição Tecidual , Tomografia Computadorizada por Raios X/normas , Contagem Corporal Total/normas , Zircônio/análise , Zircônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...