Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiology ; 311(3): e231680, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38888480

RESUMO

BACKGROUND: Women with dense breasts benefit from supplemental cancer screening with US, but US has low specificity. PURPOSE: To evaluate the performance of breast US tomography (UST) combined with full-field digital mammography (FFDM) compared with FFDM alone for breast cancer screening in women with dense breasts. MATERIALS AND METHODS: This retrospective multireader multicase study included women with dense breasts who underwent FFDM and UST at 10 centers between August 2017 and October 2019 as part of a prospective case collection registry. All patients in the registry with cancer were included; patients with benign biopsy or negative follow-up imaging findings were randomly selected for inclusion. Thirty-two Mammography Quality Standards Act-qualified radiologists independently evaluated FFDM followed immediately by FFDM plus UST for suspicious findings and assigned a Breast Imaging Reporting and Data System (BI-RADS) category. The superiority of FFDM plus UST versus FFDM alone for cancer detection (assessed with area under the receiver operating characteristic curve [AUC]), BI-RADS 4 sensitivity, and BI-RADS 3 sensitivity and specificity were evaluated using the two-sided significance level of α = .05. Noninferiority of BI-RADS 4 specificity was evaluated at the one-sided significance level of α = .025 with a -10% margin. RESULTS: Among 140 women (mean age, 56 years ±10 [SD]; 36 with cancer, 104 without), FFDM plus UST achieved superior performance compared with FFDM alone (AUC, 0.60 [95% CI: 0.51, 0.69] vs 0.54 [95% CI: 0.45, 0.64]; P = .03). For FFDM plus UST versus FFDM alone, BI-RADS 4 mean sensitivity was superior (37% [428 of 1152] vs 30% [343 of 1152]; P = .03) and BI-RADS 4 mean specificity was noninferior (82% [2741 of 3328] vs 88% [2916 of 3328]; P = .004). For FFDM plus UST versus FFDM, no difference in BI-RADS 3 mean sensitivity was observed (40% [461 of 1152] vs 33% [385 of 1152]; P = .08), but BI-RADS 3 mean specificity was superior (75% [2491 of 3328] vs 69% [2299 of 3328]; P = .04). CONCLUSION: In women with dense breasts, FFDM plus UST improved cancer detection by radiologists versus FFDM alone. Clinical trial registration nos. NCT03257839 and NCT04260620 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Mann in this issue.


Assuntos
Densidade da Mama , Neoplasias da Mama , Mamografia , Sensibilidade e Especificidade , Ultrassonografia Mamária , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Ultrassonografia Mamária/métodos , Adulto , Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos
2.
Radiology ; 298(1): 38-46, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33078996

RESUMO

Background Recognition of salient MRI morphologic and kinetic features of various malignant tumor subtypes and benign diseases, either visually or with artificial intelligence (AI), allows radiologists to improve diagnoses that may improve patient treatment. Purpose To evaluate whether the diagnostic performance of radiologists in the differentiation of cancer from noncancer at dynamic contrast material-enhanced (DCE) breast MRI is improved when using an AI system compared with conventionally available software. Materials and Methods In a retrospective clinical reader study, images from breast DCE MRI examinations were interpreted by 19 breast imaging radiologists from eight academic and 11 private practices. Readers interpreted each examination twice. In the "first read," they were provided with conventionally available computer-aided evaluation software, including kinetic maps. In the "second read," they were also provided with AI analytics through computer-aided diagnosis software. Reader diagnostic performance was evaluated with receiver operating characteristic (ROC) analysis, with the area under the ROC curve (AUC) as a figure of merit in the task of distinguishing between malignant and benign lesions. The primary study end point was the difference in AUC between the first-read and the second-read conditions. Results One hundred eleven women (mean age, 52 years ± 13 [standard deviation]) were evaluated with a total of 111 breast DCE MRI examinations (54 malignant and 57 nonmalignant lesions). The average AUC of all readers improved from 0.71 to 0.76 (P = .04) when using the AI system. The average sensitivity improved when Breast Imaging Reporting and Data System (BI-RADS) category 3 was used as the cut point (from 90% to 94%; 95% confidence interval [CI] for the change: 0.8%, 7.4%) but not when using BI-RADS category 4a (from 80% to 85%; 95% CI: -0.9%, 11%). The average specificity showed no difference when using either BI-RADS category 4a or category 3 as the cut point (52% and 52% [95% CI: -7.3%, 6.0%], and from 29% to 28% [95% CI: -6.4%, 4.3%], respectively). Conclusion Use of an artificial intelligence system improves radiologists' performance in the task of differentiating benign and malignant MRI breast lesions. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Krupinski in this issue.


Assuntos
Inteligência Artificial , Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Cancer Imaging ; 19(1): 64, 2019 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-31533838

RESUMO

BACKGROUND: As artificial intelligence methods for the diagnosis of disease advance, we aimed to evaluate machine learning in the predictive task of distinguishing between malignant and benign breast lesions on an independent clinical magnetic resonance imaging (MRI) dataset within a single institution for subsequent use as a computer aid for radiologists. METHODS: Computer analysis was conducted on consecutive dynamic contrast-enhanced MRI (DCE-MRI) studies from 1483 breast cancer and 496 benign patients who underwent MRI examinations between February 2015 and October 2017; with the age ranges of the cancer and benign patients being 19 to 77 and 16 to 76 years old, respectively. Cases were separated into a training dataset (years 2015 & 2016; 1444 cases) and an independent testing dataset (year 2017; 535 cases) based solely on MRI examination date. After radiologist indication of the lesion, the computer automatically segmented and extracted radiomic features, which were subsequently merged with a support-vector machine (SVM) to yield a lesion signature. Area under the receiving operating characteristic (ROC) curve (AUC) with 95% confidence intervals (CI) served as the primary figure of merit in the statistical evaluation for this clinical classification task. RESULTS: In the task of distinguishing malignant and benign breast lesions DCE-MRI, the trained predictive model yielded an AUC value of 0.89 (95% CI: 0.858, 0.922) on the independent image set. AUC values of 0.88 (95% CI: 0.845, 0.926) and 0.90 (95% CI: 0.837, 0.940) were obtained for mass lesions only and non-mass lesions only, respectively. Compared with actual clinical management decisions, the predictive model achieved 99.5% sensitivity with 9.6% fewer recommended biopsies. CONCLUSION: On an independent, consecutive clinical dataset within a single institution, a trained machine learning system yielded promising performance in distinguishing between malignant and benign breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Imageamento por Ressonância Magnética/métodos , Adulto , Neoplasias da Mama/patologia , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/normas , Pessoa de Meia-Idade
4.
Acad Radiol ; 26(2): 202-209, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29754995

RESUMO

RATIONALE AND OBJECTIVES: The objective of this study was to demonstrate improvement in distinguishing between benign lesions and luminal A breast cancers in a large clinical breast magnetic resonance imaging database by using quantitative radiomics over maximum linear size alone. MATERIALS AND METHODS: In this retrospective study, 264 benign lesions and 390 luminal A breast cancers were automatically segmented from dynamic contrast-enhanced breast magnetic resonance images. Thirty-eight radiomic features were extracted. Tenfold cross validation was performed to assess the ability to distinguish between lesions and cancers using maximum linear size alone and lesion signatures obtained with stepwise feature selection and a linear discriminant analysis classifier including and excluding size features. Area under the receiver operating characteristic curve (AUC) was used as the figure of merit. RESULTS: For maximum linear size alone, AUC and 95% confidence interval was 0.684 (0.642, 0.724) compared to 0.728 (0.687, 0.766) (P = 0.005) and 0.729 (0.689, 0.767) (P = 0.005) for lesion signature feature selection protocols including and excluding size features, respectively. The features of irregularity and entropy were chosen in all folds when size features were included and excluded. AUC for the radiomic signature using feature selection from all features was statistically equivalent to using feature selection from all features excluding size features, within an equivalence margin of 2%. CONCLUSIONS: Inclusion of multiple radiomic features, automatically extracted from magnetic resonance images, in a lesion signature significantly improved the ability to distinguish between benign lesions and luminal A breast cancers, compared to using maximum linear size alone. The radiomic features of irregularity and entropy appear to play an important but not a solitary role within the context of feature selection and computer-aided diagnosis.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Radiografia/métodos , Mama/diagnóstico por imagem , Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
5.
AJR Am J Roentgenol ; 211(2): 452-461, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29792747

RESUMO

OBJECTIVE: The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. MATERIALS AND METHODS: In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS-screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. RESULTS: The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. CONCLUSION: Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Computador/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Competência Clínica , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
6.
AJR Am J Roentgenol ; 198(3): 708-16, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358014

RESUMO

OBJECTIVE: The purpose of this study was to determine the effectiveness with which radiologists can use computer-aided detection (CADe) to detect cancer missed at screening. MATERIALS AND METHODS: An observer study was performed to measure the ability of radiologists to detect breast cancer on mammograms with and without CADe. The images in the study were from 300 analog mammographic examinations. In 234 cases the mammograms were read clinically as normal and free of cancer for at least 2 subsequent years. In the other 66 cases, cancers were missed clinically. In 256 cases, current and previous mammograms were available. Eight radiologists read the dataset and recorded a BI-RADS assessment, the location of the lesion, and their level of confidence that the patient should be recalled for diagnostic workup for each suspicious lesion. Jackknife alternative free-response receiver operating characteristic analysis was used. RESULTS: The jackknife alternative free-response receiver operating characteristic figure of merit was 0.641 without aid and 0.659 with aid (p = 0.06; 95% CI, -0.001 to 0.036). The sensitivity increased 9.9% (95% CI, 3.4-19%) and the callback rate 12.1% (95% CI, 7.3-20%) with CADe. Both increases were statistically significant (p < 0.001). Radiologists on average ignored 71% of correct computer prompts. CONCLUSION: Use of CADe can increase radiologist sensitivity 10% with a comparable increase in recall rate. There is potential for CADe to have a bigger clinical impact because radiologists failed to recognize a correct computer prompt in 71% of missed cancer cases [corrected].


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Computador , Erros de Diagnóstico/prevenção & controle , Mamografia , Feminino , Humanos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...