Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Laryngol Otol ; 132(9): 764-770, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30289104

RESUMO

OBJECTIVE: To summarise the available literature related to wound healing post tonsillectomy, including the stages of healing, experimental models for assessing healing (in animals and humans) and the various factors that affect wound healing. METHODS: A search of the English literature was conducted using the Ovid Medline database, with the search terms 'tonsillectomy' or 'tonsil' and 'wound healing'. Thirty-one articles that objectively assessed tonsillectomy wound healing were included for analysis. RESULTS: The majority of assessments in humans investigating tonsillectomy wound healing involve serial direct clinical examinations of the oral cavity. Many patient and surgical factors have been shown to affect wound healing after tonsillectomy. There is some research to suggest that the administration of adjunctive treatment in the post-operative period may be beneficial to tonsillectomy wound healing. CONCLUSION: Wound healing post tonsillectomy has been poorly researched. Having a better understanding of the process of wound healing would allow surgeons to potentially prevent, anticipate and manage complications from the surgery that arise as part of the healing process.


Assuntos
Tonsila Palatina/cirurgia , Tonsilectomia/efeitos adversos , Cicatrização/efeitos dos fármacos , Animais , Quimioterapia Adjuvante/efeitos adversos , Quimioterapia Adjuvante/métodos , Humanos , Modelos Teóricos , Boca/cirurgia , Período Pós-Operatório , Instrumentos Cirúrgicos/efeitos adversos , Tonsilectomia/instrumentação
2.
Clin Otolaryngol ; 43(4): 1036-1042, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29495111

RESUMO

OBJECTIVES: To examine the relationship between early life episodes of otitis media and later behavioural development with adjustment for confounders. DESIGN: Longitudinal cohort study. SETTING: The Western Australian Pregnancy Cohort (Raine) Study recruited 2900 pregnant women from King Edward Memorial Hospital (KEMH) in Perth, Western Australia, between 1989 and 1991. PARTICIPANTS: Data from the children born were collected at both the Year 3 and Year 5 follow-up. At Year 3, n = 611 were diagnosed with recurrent otitis media through parent-report and clinical examination. At Year 5, n = 299 were considered exposed to otitis media based upon tympanometry results. MAIN OUTCOME MEASURES: Performance in the Child Behaviour Checklist (CBCL), a questionnaire completed by the primary caregiver at Year 10. RESULTS: Significant associations were found between recurrent otitis media at Year 3 and internalising behaviours (P = .011), and the somatic (P = .011), withdrawn (P = .014), attention (P = .003) and thought problems domains (P = .021), and the total CBCL score (P = .010). A significant association was also found between exposure to otitis media at Year 5 and externalising behaviours (P = .026). CONCLUSIONS: A modest association was seen between recurrent otitis media at Year 3 and exposure to otitis media at Year 5 and a number of behaviour domains at Year 10.

3.
Clin Otolaryngol ; 43(1): 172-181, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28703883

RESUMO

OBJECTIVES: To investigate the relationship between hearing loss and cardiovascular disease risk factors. DESIGN: Cross-sectional study. METHODS: Participants were recruited between May 2010 and December 2015 and answered a health and risk factor questionnaire. Physical and biochemical assessments were performed. SETTING: A community-based population. PARTICIPANTS: A total of 5107 participants born within the years 1946-1964 enrolled in the Busselton Healthy Ageing Study. MAIN OUTCOME MEASURES: Hearing was assessed behaviourally through the best ear pure-tone average (500, 1000, 2000, 4000 Hz), low-frequency average (250, 500, 1000 Hz) and high-frequency average (4000, 8000 Hz). Self-reported hearing loss, tinnitus and hyperacusis were assessed via questionnaire. Cardiovascular risk factors were assessed via a patient-completed questionnaire and objective measurements including blood pressure, body mass index, waist circumference, lipid profile and glycated haemoglobin. RESULTS: Of the participants, 54% were female, with the mean age of 58 years (range 45-69 years). Age, sex and family history of hearing loss were consistently strong determinants of hearing loss outcomes. After adjusting for these, obesity, current smoking, peripheral arterial disease and history of cardiovascular disease were significantly associated with pure-tone, low-frequency and high-frequency hearing loss. In addition, high blood pressure, triglyceride and glycated haemoglobin were significantly associated with low-frequency hearing loss. There was a graded association between hearing loss and Framingham Risk Score for cardiovascular risk (P<0.001). CONCLUSIONS: Established cardiovascular disease and individual and combined cardiovascular disease risk factors were found to be associated with hearing loss. Future research should prospectively investigate whether targeting cardiovascular disease can prevent hearing loss.


Assuntos
Doenças Cardiovasculares/complicações , Perda Auditiva/etiologia , Medição de Risco , Autorrelato , Idoso , Audiometria de Tons Puros , Austrália/epidemiologia , Doenças Cardiovasculares/epidemiologia , Estudos Transversais , Feminino , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco
4.
Clin Otolaryngol ; 43(1): 182-191, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28710824

RESUMO

BACKGROUND: Age-related hearing loss (ARHL) is highly prevalent in older adults, and more than two-thirds above age of 70 years suffer from ARHL. Recent studies have established a link between ARHL and cognitive impairment; however, most of the studies have used verbally loaded cognitive measures to investigate the association between ARHL and cognition. It is possible that due to hearing impairment, the elderly may experience difficulty in following verbal instructions or completing tasks that heavily rely on hearing during cognitive assessments. This may result in overestimation of cognitive impairment in such individuals. This baseline cross-sectional study investigated the associations between untreated hearing loss and a number of cognitive functions using a battery of non-verbal cognitive tests. Further, association between hearing loss and psychological status of older adults was examined. STUDY DESIGN: Prospective case-controlled study. METHODS: A total of 119 participants (54 males, M=66.33±10.50 years; 65 females M=61.51±11.46 years) were recruited. All participants completed a hearing assessment, a computerised test battery of non-verbal cognitive functions and the depression, anxiety and stress scale. RESULTS: Hierarchical multiple regression analysis results revealed that hearing thresholds significantly associated with the working memory (P<0.05), paired associative learning scores (P<0.05), depression (P<0.001), and anxiety (P<0.001) and stress (P<0.001) scores. Analysis of covariance results revealed that participants with moderately-severe hearing loss performed significantly poorer in paired associative learning and working memory tasks and psychological function tests compared to those with normal hearing. CONCLUSION: Results of the current study suggest a significant relationship between ARHL and both cognition and psychological status. Our results also have some implications for using non-verbal cognitive tests to evaluate cognitive functions in post-lingually hearing impaired ageing adults, at least for those with more than moderately-severe levels of hearing loss.


Assuntos
Envelhecimento/fisiologia , Transtornos Cognitivos/etiologia , Cognição/fisiologia , Perda Auditiva/complicações , Percepção da Fala/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Transtornos Cognitivos/epidemiologia , Transtornos Cognitivos/fisiopatologia , Estudos Transversais , Feminino , Perda Auditiva/epidemiologia , Perda Auditiva/psicologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Austrália Ocidental/epidemiologia
5.
Diabet Med ; 34(5): 683-690, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28135010

RESUMO

AIMS: To investigate the independent associations between hearing loss and dysglycaemia in a sample of middle-aged adults, including separate analysis of those aged < 60 years. METHODS: The first 2023 participants in the cross-sectional Busselton Health Ageing Survey were assessed for hearing loss ≥ 26 dB (better ear) for four-frequency average (4FA) of pure-tone thresholds at 500, 1000, 2000 and 4000 Hz, and high-frequency average (HFA) of pure-tone thresholds at 4000 and 8000 Hz. RESULTS: Valid data from 1864 participants in the Busselton Health Ageing Survey [92.1%; mean ± sd age 56.2 ± 5.5 years, 46.0% men, 120 (7.0%) with diabetes, 274 (14.7%) with prediabetes] were analysed, of whom 103 (5.5%) had four-frequency average hearing loss and 561 (30.1%) had high-frequency average hearing loss. In multivariable analyses, glycaemic status was not independently associated with four-frequency or high-frequency average hearing loss. In the 1286 participants aged < 60 years, there was no relationship between dysglycaemia and high-frequency average hearing loss, but the prevalence of four-frequency average hearing loss increased from 2.3% (95% CI 1.5-3.4) in participants with normoglycaemia to 5.7% (95% CI 3.0-10.6) in those with prediabetes and 10.2% (4.2-21.5) in those with diabetes (trend P = 0.003). In multivariable analysis with normoglycaemia as reference, the odds ratios for four-frequency average hearing loss were 2.84 (95% CI 1.29-6.27) for prediabetes and 5.93 (95% CI 1.67-21.05) for diabetes (P ≤ 0.01) in the < 60 year age group. CONCLUSIONS: There was progressively increasing mid-range hearing loss with worsening glucose tolerance in younger individuals, suggesting dysglycaemia-associated early-onset presbycusis.


Assuntos
Diabetes Mellitus Tipo 2/epidemiologia , Perda Auditiva/epidemiologia , Estado Pré-Diabético/epidemiologia , Idade de Início , Envelhecimento/sangue , Envelhecimento/fisiologia , Glicemia/metabolismo , Estudos Transversais , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/complicações , Feminino , Transtornos do Metabolismo de Glucose/sangue , Transtornos do Metabolismo de Glucose/complicações , Transtornos do Metabolismo de Glucose/epidemiologia , Perda Auditiva/sangue , Perda Auditiva/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/complicações , Presbiacusia/sangue , Presbiacusia/epidemiologia , Prevalência
6.
Clin Otolaryngol ; 42(1): 164-171, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27455457

RESUMO

OBJECTIVE: A self-administered device management survey was developed and validated to investigate the ability of cochlear implant recipients to self-report physical handling and care for their hearing implant device(s) and to identify factors that may influence self-reported management skills. DESIGN: Survey development and validation. A prospective convenience cohort design study. SETTING: Specialist hearing implant clinic. PARTICIPANTS: Forty-nine post-lingually hearing impaired, adult cochlear implant recipients, at least 12 months postoperative. MAIN OUTCOME MEASURES: Survey test-retest reliability, responsiveness, criterion validity and sensitivity and specificity compared to clinician evaluation of device management skills. Correlations between self-reported management skills and participant demographic, audiometric, cognitive function, clinical outcomes and device factors. RESULTS: The self-administered Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (ICC = 0.884, P < 0.001; CI 95%: 0.721-0.952), responsiveness to intervention (management skills training) [t(20) = -3.245, P = 0.004], criterion validity (ICC = 0.765, P < 0.001; CI 95%: 0.584-0.868) and sensitivity (0.89). No associations were found between self-reported management skills and participant factors. CONCLUSIONS: This study demonstrated that a self-report survey is an effective method for the evaluation of skills required for cochlear implant device management.


Assuntos
Implantes Cocleares , Perda Auditiva/psicologia , Perda Auditiva/terapia , Autocuidado , Autorrelato , Análise e Desempenho de Tarefas , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante Coclear , Cognição , Feminino , Perda Auditiva/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Clin Otolaryngol ; 42(1): 29-37, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27037737

RESUMO

OBJECTIVES: To examine the long-term effects of predominant breastfeeding on incidence of otitis media. DESIGN: Prospective birth cohort study. SETTING: The West Australian Pregnancy Cohort (Raine) Study recruited 2900 mothers through antenatal clinics at the major tertiary obstetric hospital in Perth, Western Australia, between 1989 and 1992. PARTICIPANTS: In total, 2237 children participated in a 6-year cohort follow-up, and a subset of 1344 were given ear and hearing assessments. MAIN OUTCOME MEASURES: OM diagnosis at 6 years of age (diagnosed by low-compliance tympanograms, 0-0.1 mmho). This was compared to OM diagnosed at the 3-year cohort follow-up using parent-report measures. Main exposure measures were duration of predominant breastfeeding (defined as the age other milk was introduced) and duration of partial (any) breastfeeding (defined as the age breastfeeding was stopped). RESULTS: There was a significant, independent association between predominant breastfeeding (OR = 1.33 [1.04, 1.69]; P = 0.02) and OM, and breastfeeding duration (OR = 1.35 [1.08, 1.68]; P = 0.01) with OM at 3 years of age. However, at 6 years of age, this relationship was no longer statistically significant (predominant breastfeeding OR = 0.78 [0.48, 1.06]; P = 0.09; duration of breastfeeding, OR = 1.34 [0.81, 2.23]; P = 0.25). CONCLUSIONS: Our findings are in line with a number of epidemiological studies which show a positive association between breastfeeding and OM in early childhood. However, the long-term follow-up of these children revealed that by 6 years of age, there was no significant influence of breastfeeding on presence of OM. These results suggest that the protective effect of predominant breastfeeding for at least 6 months does not extend to school-age children, where other social and environmental factors may be stronger predictors of OM.


Assuntos
Aleitamento Materno , Otite Média/epidemiologia , Fatores Etários , Austrália , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Otite Média/prevenção & controle , Fatores Socioeconômicos , Fatores de Tempo
8.
Clin Otolaryngol ; 41(1): 51-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26039905

RESUMO

OBJECTIVE: To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. DESIGN: Survey development and validation. A prospective convenience cohort design study. SETTING: Specialist hearing implant clinic. PARTICIPANTS: Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. MAIN OUTCOME MEASURES: Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. RESULTS: The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. CONCLUSIONS: This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills.


Assuntos
Implantes Cocleares , Autocuidado , Adulto , Idoso , Audiometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Inquéritos e Questionários
9.
Clin Otolaryngol ; 41(6): 718-729, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26670203

RESUMO

OBJECTIVE: Hearing loss affects over 1.23 billion people globally. It has been proposed that hearing impairment negatively impacts on cognition. Some studies have demonstrated a faster rate of decline in cognition, and increased risk of incident all-cause dementia. This finding is not ubiquitous. This study used meta-analysis to examine the evidence-base regarding the relationship between hearing and cognition. DESIGN: A systematic review of the literature and meta-analyses of study findings were conducted. Published and grey literature was reviewed. Papers were included if they studied the relationship between hearing and cognition in adults with and without hearing impairment. MAIN OUTCOME MEASURES: Meta-analyses examined evidence for and against seven questions. Is cognition poorer in individuals with normal hearing compared to (i) untreated or (ii) treated hearing impairment, is cognition associated with degree of hearing impairment in (iii) untreated and/or (iv) treated hearing, is cognition (v) different in untreated compared to treated hearing impairment, (vii) does cognition improve after intervention, and (vii) how is hearing impairment differentially associated with cognitive ability across six domains of cognition? RESULTS: The 33 included studies contributed 40 samples, with a total of 602 participants with untreated hearing impairment, 672 participants with treated hearing impairment, 176 healthy controls, and 4260 individuals with a range of hearing impairment with/without treatment. The results demonstrated that cognition is significantly poorer in (i) individuals with untreated hearing and remains poorer in (ii) treated hearing impairment compared to normal hearers. The degree of cognitive deficit is significantly associated with the degree of hearing impairment in both (iii) untreated and (iv) treated hearing impairment. Furthermore, (v) hearing intervention significantly improves cognition. Finally, (vii) hearing impairment impacted on all domains of cognition. CONCLUSIONS: This meta-analysis suggests that hearing impairment is associated with cognitive problems. However, due to diversity within studies, small sample sizes, the failure to control for premorbid and other health factors, this conclusion may be premature.


Assuntos
Transtornos Cognitivos/epidemiologia , Perda Auditiva/psicologia , Adulto , Feminino , Humanos , Masculino
11.
J Laryngol Otol ; 127 Suppl 1: S13-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22892109

RESUMO

BACKGROUND: Chronic tympanic membrane perforations can cause significant morbidity. The term myringoplasty describes the operation used to close such perforations. A variety of graft materials are available for use in myringoplasty, but all have limitations and few studies report post-operative hearing outcomes. Recently, the biomedical applications of silk fibroin protein have been studied. This material's biocompatibility, biodegradability and ability to act as a scaffold to support cell growth prompted an investigation of its interaction with human tympanic membrane keratinocytes. METHODS AND MATERIALS: Silk fibroin membranes were prepared and human tympanic membrane keratinocytes cultured. Keratinocytes were seeded onto the membranes and immunostained for a number of relevant protein markers relating to cell proliferation, adhesion and specific epithelial differentiation. RESULTS: The silk fibroin scaffolds successfully supported the growth and adhesion of keratinocytes, whilst also maintaining their cell lineage. CONCLUSION: The properties of silk fibroin make it an attractive option for further research, as a potential alternative graft in myringoplasty.


Assuntos
Fibroínas , Queratinócitos/fisiologia , Miringoplastia/métodos , Alicerces Teciduais , Perfuração da Membrana Timpânica/cirurgia , Membrana Timpânica/citologia , Adulto , Materiais Biocompatíveis , Técnicas de Cultura de Células , Proliferação de Células , Criança , Doença Crônica , Imunofluorescência , Humanos , Queratinócitos/metabolismo , Queratinócitos/ultraestrutura , Teste de Materiais/métodos , Proteínas de Membrana/metabolismo , Otite Média Supurativa/complicações , Proteína Proto-Oncogênica c-ets-1/metabolismo , Engenharia Tecidual/métodos , Membrana Timpânica/fisiologia , Perfuração da Membrana Timpânica/complicações
12.
Clin Otolaryngol ; 31(4): 273-9, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16911642

RESUMO

OBJECTIVES: To determine the quality of life (QOL) after stapes surgery and whether audiological parameters for hearing correlate with specific QOL factors. DESIGN: A retrospective cross-sectional study. SETTING: A tertiary referral centre. PARTICIPANTS: A series of 35 patients who underwent stapes surgery of which three were excluded because they were <18 years of age, chronically or mentally ill, or in a dependant relationship. Response rate was 93% (30/32). Nine were further excluded because they had revision or bilateral surgery, or missing data. Twenty-one patients were included in this study. MAIN OUTCOME MEASURES: The Glasgow Benefit Inventory (GBI) was used to evaluate general QOL and the Hearing Disability and Handicap Scale (HDHS) was used as a disease-specific measure. The Belfast Rule of Thumb and Glasgow Benefit Plot assessed hearing outcomes. RESULTS: Operative success was 86% using the Belfast Rule of Thumb and 95% had closure of the air-bone gap to within 20 dB. 81.8% of patients reported a better overall QOL as surgery. Glasgow Benefit Inventory Social and GBI Physical scores correlated positively with the HDHS speech component (P < 0.05). The duration of hearing loss correlated inversely with the average HDHS score (P < 0.05). CONCLUSION: The majority of patients report a better QOL as undergoing stapes surgery. Speech impacts on people's physical and social QOL of patients. Quality of life tools, in addition to objective audiologic measurements can provide clinicians with patients' subjective perspective that helps guide clinical decision-making and counselling.


Assuntos
Perda Auditiva Condutiva/cirurgia , Otosclerose/cirurgia , Qualidade de Vida , Cirurgia do Estribo , Atividades Cotidianas , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Perda Auditiva Condutiva/psicologia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Otosclerose/psicologia , Estudos Retrospectivos , Cirurgia do Estribo/psicologia , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
13.
Acta Otolaryngol ; 126(2): 149-53, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16428191

RESUMO

CONCLUSIONS: The results of this study have demonstrated for the first time that tympanic membrane (TM) structure is preserved following removal of fresh, normal tissue from patients undergoing surgery. Greater clarity has been demonstrated using resin sections than in previous studies on paraffin sections. Of particular note, cytokeratin (CK) immunocytochemistry was successfully performed on resin sections, which has not been previously reported. This may have potential applications for future work involving tissues that express CKs. OBJECTIVES: To analyse the structure of normal, fresh human TM specimens after surgical removal and to evaluate their CK immunocytochemistry using resin techniques, neither of which have been demonstrated previously. MATERIAL AND METHODS: Seven TM specimens were removed during surgery and then preserved in a modified Karnovsky's fixative. Semi-thin and thin sections were examined by means of light and electron microscopy, respectively. For comparison purposes, paraffin block-embedded specimens were also sectioned. CK immunocytochemistry was performed on semi-thin sections using standard immunoperoxidase techniques, with expression being demonstrated using light microscopy. RESULTS: The three-layer architecture of the TM was preserved. The morphology of the TM was vastly superior in the semi-thin resin sections than in the thicker paraffin sections. The outer, middle and inner layers were clearly demonstrated. The integrity of the outer epithelial layer was maintained, with an outer keratinizing stratum corneum and underlying stratum granulosum, stratum spinosum and stratum basale layers resting on the basal lamina. The thin inner mucosal layer was also viable, consisting of simple squamous or cuboidal cells. Preservation of the middle lamina propria was achieved, with demonstration of the outer radial and inner circular fibres. CK immunocytochemistry utilizing resin techniques provided excellent staining of CK 7 and 8 in the inner layer, with positive staining of CK 5 and 10 in the outer layer.


Assuntos
Queratinas/análise , Membrana Timpânica/anatomia & histologia , Membrana Timpânica/química , Adolescente , Adulto , Idoso , Criança , Humanos , Imuno-Histoquímica , Microscopia Eletrônica , Pessoa de Meia-Idade , Membrana Timpânica/ultraestrutura
14.
Lasers Med Sci ; 16(1): 52-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11486339

RESUMO

The objective of this study was to examine the properties of two laser lines 514 nm and 532 nm when used to image the retina with a scanning laser ophthalmoscope (SLO), and to compare the images taken with a simultaneous multiple wavelength SLO, to those taken with a fundus camera. From this we concluded that the 514 nm line is the preferred line for visualising the nerve fibre layer whereas the 532 nm line is preferred for visualising retinal vessels. Based on these results the 532 nm laser light source was selected as the green line for imaging with the simultaneous colour SLO. Cases are presented where the colour SLO images contain more information than traditional digitised fundus photographs.


Assuntos
Fundo de Olho , Lasers , Oftalmoscopia , Humanos
15.
Arch Ophthalmol ; 119(4): 533-7, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11296018

RESUMO

OBJECTIVE: To determine absorption coefficients for sodium chloride solution (saline) and balanced salt solution at the 193- and 213-nm laser wavelengths. METHODS: Absorption coefficients were obtained for each of the component species found in balanced salt solution. This was achieved by measuring laser pulse transmission through solutions of varying concentration. The experiments were repeated using the 193-nm excimer and 213-nm solid-state laser wavelengths. Results for each species were then used to obtain an overall absorption coefficient and penetration depth for balanced salt solution and 0.9% sodium chloride solution. RESULTS: Absorption coefficients in balanced salt solution for the 193- and 213-nm wavelengths were found to be 140 and 6.9 cm(-1), respectively. In 0.9% sodium chloride solution, the absorption coefficient was 81 cm(-1) at 193 nm and 0.05 cm(-1) at 213 nm. At 193 nm, absorption in balanced salt solution was dominated by sodium chloride. Sodium citrate emerged as the dominant species of absorption at 213 nm. CONCLUSIONS: For the species investigated, we found reduced absorption for the longer wavelength of 213 nm. While the difference in wavelength between 193 and 213 nm is within about 10%, the respective molar absorption coefficients varied by 1 to 4 orders of magnitude. This indicates that predictions for the wavelength-dependent changes of absorption coefficients of other solutions are unreliable. CLINICAL RELEVANCE: Fluid placed on the surface of the cornea during keratorefractive surgery has proved to be a barrier to ablation for the 193-nm wavelength. The increased penetration depth through sodium chloride solution and balanced salt solution for the longer 213-nm laser wavelength may mean that these solutions cannot be used as a masking agent for keratorefractive procedures performed with this wavelength.


Assuntos
Acetatos/efeitos da radiação , Lasers , Minerais/efeitos da radiação , Cloreto de Sódio/efeitos da radiação , Absorção , Combinação de Medicamentos , Lasers de Excimer , Ceratectomia Fotorrefrativa
16.
Waste Manag ; 21(3): 295-302, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11280522

RESUMO

Some 20 years ago Dutch society became very aware of the problem of the increasing production of waste materials and of the need to find solutions. Technical solutions had to be developed and introduced into society. Due to the discovery of many soil pollution problems and other environmental calamities, people asked for clear criteria on which proper and safe solutions could be based. Therefore a large number of environmental aspects had to be taken into account in the developing field of environmental policy. The Dutch building materials decree is one of the steps on the road towards a sustainable society. The decree is based on the soil protection act and the surface water protection act. The decree gives quality criteria for the application and re-use of stony materials and earth used as building materials. No difference is made between primary materials, secondary materials and waste materials. The decree is applicable in case these materials are used in constructions where they are in contact with rain, surface water and ground water (e.g. in embankments, road building, outside walls of buildings, foundations and roofs). For implementation of the decree in the construction industry it was necessary to develop standards, methods for testing and certification schemes. In order to guarantee independent testing and judgement, laboratories had to meet quality standards put forward in an accreditation scheme. Although this legislation does not cover all environmental aspects, it has proved to be an important element in judging the environmental quality of construction materials in a direct or indirect way, and a contribution to the management of waste materials. The question of clear and fair criteria was easily put forward. Answering this question, however, turned out to be a complex task in which a great number of aspects had to be considered and a great many tools had to be developed, checked and thoroughly discussed. In some cases practical choices had to be made in order to prevent an unclear situation continuing too long. After an introduction period of three years, the decree came into full operation on 1 July 1999.


Assuntos
Materiais de Construção/normas , Poluição Ambiental/prevenção & controle , Política Pública , Países Baixos , Formulação de Políticas , Controle de Qualidade
17.
Int Ophthalmol ; 23(4-6): 343-6, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11944860

RESUMO

Oximetry may be useful for understanding pathologies of the eye. We use a prototype scanning laser ophthalmoscope capable of simultaneous multiple wavelength imaging to record fundus images. The system is run under non-confocal conditions in using slit apertures with a width of up to 600 microm. The laser lines launched into the SLO were the 633 nm line of a HeNe-laser, and the 815 nm line from a tunable (700 to 900 nm) cw Ti:Sapphire-laser. These wavelengths were selected because of their availability and absorption characteristics. The difference in absorption at these two wavelengths is used to assess blood oxygen content. Images were averaged to improve the signal to noise ratio. This simultaneous method of measuring oxygen content may be preferred to other techniques such as sequential SLO imaging at different wavelengths, or spot analysis using a modified fundus camera. The advantages of this technique are that image registration is not required, and a large area of the retina can be assessed concurrently.


Assuntos
Oximetria/métodos , Oxigênio/sangue , Vasos Retinianos/metabolismo , Humanos , Lasers , Oftalmoscópios , Fluxo Sanguíneo Regional
18.
Int Ophthalmol ; 23(4-6): 405-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11944868

RESUMO

Differential imaging may be useful for understanding pathologies of the choroid. We use a prototype scanning laser ophthalmoscope capable of simultaneous multiple wavelength imaging to record fundus images. The advantages of simultaneous acquisition compared to serial acquisition are, reduced image capture times, and image registration is not required. The system is run under non-confocal conditions in using slit apertures with a width of up to 600 microm. The laser lines launched into the SLO were the 633 nm line of a HeNe- laser, and the 815 nm line from a tunable (740 nm to 840 nm) cw Ti:Sapphire-laser. The difference in absorption at these two wavelengths is used to produce a differential image. We compare conventional imaging with differential spectral imaging for viewing the choroidal vessels. Qualitative results show the contrast of choroidal vessels in differential imaging is improved compared with normal imaging in the region of the optic disk and for the level of pigmentation in the subjects examined.


Assuntos
Corioide/irrigação sanguínea , Diagnóstico por Imagem/métodos , Oftalmoscopia/métodos , Vasos Sanguíneos/anatomia & histologia , Humanos , Lasers , Microcirculação
19.
J Refract Surg ; 16(5): S643-6, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11019890

RESUMO

PURPOSE: Patient eye and head movements during laser refractive surgery may result in errors between the surgical beam position and the desired location for optimum correction. This, in turn, may lead to reduced postoperative vision, including increased higher order aberrations of the eye. Active eye tracking systems are often incorporated into laser delivery systems, which aim to reduce the effect of patient eye movement. METHODS: In this study, the accuracy of an eye tracking system designed for laser refractive surgery was determined. An enucleated porcine eye was attached to a scanning device and the movement measured using the eye tracking system. The recorded position is compared to the preprogrammed position of the scanning device. RESULTS: The system demonstrated an accuracy of 0.06 m for an intact cornea and 0.1 mm for a cornea with a thin flap removed. This compares to an average decentration of ablation of 0.4 mm for patients relying on passive fixation, as measured by previous clinical trials. CONCLUSION: implementation of this eye tracker would lead to improved alignment between the laser and eye during laser refractive surgery.


Assuntos
Técnicas de Diagnóstico Oftalmológico/normas , Movimentos Oculares , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Procedimentos Cirúrgicos Refrativos , Animais , Técnicas de Diagnóstico Oftalmológico/instrumentação , Lasers de Excimer , Pupila , Reprodutibilidade dos Testes , Suínos , Gravação em Vídeo
20.
Clin Exp Ophthalmol ; 28(3): 129-32, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10981779

RESUMO

The purpose of this study was to explore progress, in the adaptation to community screening for blinding eye disease, of digital imaging devices and technology for storage and transmission. Available imaging systems were compared to gold standard clinical photography in terms of sensitivity and specificity for diagnosis of common blinding eye conditions. Since the use of expensive non-portable imaging devices is likely to be limited for widespread community screening purposes, a portable fundus camera (Nidek, Chiyoda-ku, Japan) and a prototype monocular digital indirect ophthalmoscope constructed at the Lions Eye Institute (LEI) were selected for comparative trials for the screening of optic disc cupping, glaucoma and clinical signs of diabetic retinopathy. Fifty-one eyes of 27 consecutive patients being assessed at the LEI clinic for glaucoma were dilated and photographed with a Zeiss retinal camera, and digital images were taken with the portable Nidek NM100 fundus camera (Carl Zeiss, Oberkochen, Germany) or with a prototype digital monocular indirect ophthalmoscope. Vertical cup: disc ratios (VCDR) were measured on the disc photographs by one ophthalmologist while three other clinicians were presented with compressed digital images in random order to estimate VCDR. Field trials were also carried out to demonstrate the practicality of compression, local storage and then transmission by mobile telephone ISDN lines and satellite, of optic discs and fundus images of patients with diabetes in either rural Western Australia or Surabaya, Indonesia. Kappa values of correlations of measurement of agreement between measured and estimated VCDR were 0.87, 0.45 and 0.84, respectively, for the three observers, corresponding to a specificity of 79-97% and a sensitivity of 70-95%. The portable Nidek fundus camera was also assessed for specificity and sensitivity in the diagnosis of diabetic retinopathy in comparison to standard Zeiss fundus camera photographs. Of 49 eyes in 25 consecutive patients attending the LEI clinic for assessment of diabetic retinopathy, three ophthalmologists assessed photographs and images in random order. When used for screening diabetic retinopathy, the digital images of the Nidek camera were graded as adequate quality in only 56% of eyes compared to 93% of the photographs. The kappa value of agreement in analysis of diabetic retinopathy was only 0.30. The prototype digital monocular indirect ophthalmoscope compared favourably with the Nidek camera. At 1:5 compression, images of size 36 kB transmitted from Surabaya to Perth took 29 s on the mobile telephone, while uncompressed images took 170 s. Images compressed 1:5 were transmitted in 60 s using the satellite telephone, while the uncompressed images took 240 s. Satellite transmission was more expensive but the lines were more stable than telephone connections from Indonesia. Digital imaging is becoming a powerful tool for ophthalmology in clinical records, teaching and research, and interoffice diagnostic opinions. It also has enormous potential for community screening for blinding eye diseases, such as glaucoma and diabetic retinopathy. Inexpensive portable imaging devices that are easy to use, and on which local health workers might be trained, must be developed and validated in terms of sensitivity and specificity of performance. The technology of image capture, image compression, transmission, data base storage and analysis is rapidly evolving and becoming less expensive.


Assuntos
Retinopatia Diabética/diagnóstico , Glaucoma/diagnóstico , Processamento de Sinais Assistido por Computador , Seleção Visual/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Oftalmoscopia , Disco Óptico/patologia , Fotografação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Telemedicina/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA